• Title/Summary/Keyword: Ground modification

Search Result 166, Processing Time 0.024 seconds

Seismic Design of Structures in Low Seismicity Regions

  • Lee, Dong-Guen;Cho, So-Hoon;Ko, Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.4
    • /
    • pp.53-63
    • /
    • 2007
  • Seismic design codes are developed mainly based on the observation of the behavior of structures in the high seismicity regions where structures may experience significant amount of inelastic deformations and major earthquakes may result in structural damages in a vast area. Therefore, seismic loads are reduced in current design codes for building structures using response modification factors which depend on the ductility capacity and overstrength of a structural system. However, structures in low seismicity regions, subjected to a minor earthquake, will behave almost elastically because of the larger overstrength of structures in low seismicity regions such as Korea. Structures in low seismicity regions may have longer periods since they are designed to smaller seismic loads and main target of design will be minor or moderate earthquakes occurring nearby. Ground accelerations recorded at stations near the epicenter may have somewhat different response spectra from those of distant station records. Therefore, it is necessary to verify if the seismic design methods based on high seismicity would he applicable to low seismicity regions. In this study, the adequacy of design spectra, period estimation and response modification factors are discussed for the seismic design in low seismicity regions. The response modification factors are verified based on the ductility and overstrength of building structures estimated from the farce-displacement relationship. For the same response modification factor, the ductility demand in low seismicity regions may be smaller than that of high seismicity regions because the overstrength of structures may be larger in low seismicity regions. The ductility demands in example structures designed to UBC97 for high, moderate and low seismicity regions were compared. Demands of plastic rotation in connections were much lower in low seismicity regions compared to those of high seismicity regions when the structures are designed with the same response modification factor. Therefore, in low seismicity regions, it would be not required to use connection details with large ductility capacity even for structures designed with a large response modification factor.

Statistical Study of Ductility Factors for Elastic Perfectly Plastic SDOF Systems (탄소성 단자유도 구조물에 대한 연성계수의 통계적 분석)

  • Kang, Cheol-Kyu;Choi, Byong-Jeong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.39-48
    • /
    • 2003
  • This paper present a summary of the results of statistical study of the ductility factor which is key component of response modification factor(R). To compute the ductility factor, a group of 1,860 ground motions recorded from various earthquake was considered. Based on the local site conditions at the recording station, ground motions were classified into four groups according to average shear wave velocity. Inleastic spectrum were computed for elastic perfectly plastic SDOF systems undergoing different level of inelastic deformation and period. Ductility factors were calculated by deviding elastic response spectrum by inelastic response spectrum. The influence f displacement ductility ratio, site condition, magnitude and epicentral distance on ductility factors were studied. The coefficient of variation was computed to evaluated the dispersion of ductility factors as the defined ratio of the standard deviation to the mean.

A Case Study on the Unmanned Modification Process of 500MD Helicopter (500MD 헬리콥터의 무인화 개발과정 사례 연구)

  • Kim, Won-Jin;Son, Taek-Joon;Kim, Hong-Dae;Gong, Byung-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.4
    • /
    • pp.329-334
    • /
    • 2021
  • Korean Air has set the goal of the first stage of the development of unmanned helicopters to perform in hovering flight by remote control. In order to achieve the development goal, Korean Air carried out system integration, ground test, and safety wire test in sequence after carrying out programmed depot maintenance and aircraft modification of manned aircraft, and verified the controllability and flight safety of the unmanned helicopter system step by step. In particular, it was confirmed that the safety wire test technique used in the final stage of verification was an effective method to verify flight safety and controllability for a fully unmanned helicopter system.

A Study on the Development of Envi-Cone Penetrometer System (지반환경조사용 환경콘 관입시스템 개발을 위한 기초연구)

  • 정하익;홍승서;김영진;홍성완;곽무영
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.247-254
    • /
    • 1999
  • In recent years there has been a steady increase in geoenvironmental engineering projects where geotechnical engineering has been combined with environmental concerns. Many of these projects involve some investigation of contaminant in the ground. There are many techniques such as geophysical, drilling, sampling, and pushing techniques for investigation of contaminated ground. The most rapidly developing site characterization techniques for geoenvironmental purposes Involve direct push technology, that is, penetration tests. In this study, the envi-cone penetrometer system is developed by modification of traditional cone penetration test. The electrical resistivity sensor, pH sensor, thermometer are installed in envi-cone penetrometer system. This envi-cone penetrometer system provides a continuous profile of measurements, and it is rapid, repeatable, reliable and cost effective.

  • PDF

A Modified Selective Ground Relay for Ungrounded Distribution Systems

  • Nam Soon-Ryul;Kang Sang-Hee;Park Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.16-22
    • /
    • 2006
  • Selective ground relays (SGRs) are useful fur distinguishing a faulted feeder from the sound feeders in ungrounded systems. However, they sometimes mis-operate due to human or device errors. Particularly, the reversed polarity of zero-sequence current transducers (ZCTs) is the most frequent cause of mis-operation. This paper presents a modified SGR for reducing the probability of mis-operations caused by the reversed polarity of ZCTs. The modification is achieved by introducing an adaptive time delay, which depends on the magnitude of the zero-sequence current and the phase angle deviation from the reference. The modified SGR was successfully demonstrated on a sample ungrounded system without mis-operation.

Lowpass Filter Design For Eliminate The Harmonic Signals Using Photonic Bandgap Structure

  • Kim Jang Kwon;Kim Dong Sik;Kang Chang Soo
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.19-22
    • /
    • 2004
  • The goal of this study is to realize the PBG lowpass filter using novel PBG structure modification both upper layer and ground layer. It has been designed three aperture slots of ground layer for PBG structure which the center slot shape of ground is two type, rectangular and dumbbell. This PBG LPF has the character of the broader stopband and smaller size than typical LPF. The measurement results have matched the simulated ones. It has the cutoff frequency of each 4.465GHz and 3.52GHz and at least -20dB of the signal suppression at the stopband

  • PDF

On the improvement of inelastic displacement demands for near-fault ground motions considering various faulting mechanisms

  • Esfahanian, A.;Aghakouchak, A.A.
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.673-698
    • /
    • 2015
  • This paper investigates inelastic seismic demands of the normal component of near-fault pulse-like ground motions, which differ considerably from those of far-fault ground motions and also parallel component of near-fault ones. The results are utilized to improve the nonlinear static procedure (NSP) called Displacement Coefficient Method (DCM). 96 near-fault and 20 far-fault ground motions and the responses of various single degree of freedom (SDOF) systems constitute the dataset. Nonlinear Dynamic Analysis (NDA) is utilized as the benchmark for comparison with nonlinear static analysis results. Considerable influences of different faulting mechanisms are observed on inelastic seismic demands. The demands are functions of the strength ratio and also the pulse period to structural period ratio. Simple mathematical expressions are developed to consider the effects of near-fault motion and fault type on nonlinear responses. Modifications are presented for the DCM by introducing a near-fault modification factor, $C_N$. In locations, where the fault type is known, the modifications proposed in this paper help to obtain a more precise estimate of seismic demands in structures.

CONSTRUCTION MANAGEMENT OF TUNNELLING IN SEVERE GROUNDWATER CONDITION

  • Young Nam Lee;Dae Young Kim
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.655-661
    • /
    • 2005
  • For a hydro power plant project, the headrace tunnel having a finished diameter of 3.3m was constructed in volcanic rocks with well-developed vertical joint and high groundwater table. The intake facility was located 20.3 km upstream of the powerhouse and headrace tunnel of 20 km in length and penstock of 440 m in height connected the intake and the powerhouse. The typical caldera lake, Lake Toba set the geology at the site; the caving of the ground caused tension cracks in the vertical direction to be developed and initial stresses at the ground to be released. High groundwater table(the maximum head of 20 bar) in the area of well-connected vertical joints delayed the progress of tunnel excavation severely due to the excessive inflow of groundwater. The excavation of tunnel was made using open-shield type TBM and mucking cars on the rail. High volume of water inflow raised the water level inside tunnel to 70 cm, 17% of tunnel diameter (3.9 m) and hindered the mucking of spoil under water. To improve the productivity, several adjustments such as modification of TBM and mucking cars and increase in the number of submersible pumps were made for the excavation of severe water inflow zone. Since the ground condition encountered during excavation turned out to be much worse, it was decided to adopt PC segment lining instead of RC lining. Besides, depending on the conditions of the water inflow, rock mass condition and internal water pressure, one of the invert PC segment lining with in-situ RC lining, RC lining and steel lining was applied to meet the site specific condition. With the adoption of PC segment lining, modification of TBM and other improvement, the excavation of the tunnel under severe groundwater condition was successfully completed.

  • PDF

A Study on the Selection and Modification of Ground Motion Based on Site Response Analysis (부지응답해석에 기반한 지반운동 선정 및 보정에 관한 고찰)

  • Hwang, Jung-Hyun;Mauk, Ji-Wook;Son, Hyeon-Sil;Ock, Jong-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.103-110
    • /
    • 2020
  • In the recent seismic design code KDS 41 17 00, selection and modification procedures of ground motions which are used for nonlinear dynamic analyses were adopted. However, its practical applications are still limited due to the lack of literatures. This paper introduces case studies which used site-response analyses to select and modify ground motions for nonlinear dynamic analyses. Based on the case studies, design criterion for site-response analyses were reviewed thoroughly in the viewpoint of practical applications. It was found that design requirements related with bedrock motions are too conservative that ground motions are selected and modified in the excessive manner. It is especially true for low-rise building structures with period ranges including acceleration-sensitive regions. Even though surface motions have shown appropriate responses, such building structures have to re-select and re-modify ground motions based on pre-analysis procedures rather than post-ones according to the current seismic design code. Also, it was observed that building structures with soft soils under strong ground motions need more comprehensive investigations on soil properties and efficient analysis methods in order to perform site-response analyses. This is due to the fact that lack of reliabilities on soil properties and analysis methods could result in unstable site-responses.

Evaluation of Ductility Factors for MDOF Systems in Special Steel Moment Resisting Frames (철골 연성 모멘트 골조에 대한 다자유도 시스템의 연성계수 평가)

  • Kang, Cheol-Kyu;Han, Young-Cheol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.6 s.40
    • /
    • pp.13-22
    • /
    • 2004
  • Ductiluty factor has played an important role in seismic design as it is key component of response modification factor(R). In this stuty, ductility factors() are calculated by multiplying ductility factor for SDOF systems() and MDOF modification factors(). Ductility factors() for SDOF systems are computed from nonlinear dynamic analysis undergoing different level of displacement ductiluty demands and period when subjected to a large number of recorded earthquake ground motions. The MDOF modification factors() are proposed to account for the MDOF systems, based on previous studies. A total of 108 prototype steel frames are designed to investigate the ductility factors considering the number of stories(4, 8 and 16-stories), framing system(Perimeter Frames, PF and Distributed Frames, DF), failure mechanism(Strong-Column Weak-Beam, SCWB and Weak-Column Strong-Beam, WCSB), soil profiles(SA, SC and SE in UBC 1997) and seismic zone factors(Z=0.075, 0.2 and 0.4 in UBC 1997). It is shown that the number of stories, failure mechanisms (SCWB, WCSB), and soil profiles have great influence on the ductility factors, however, the structural system(Perimeter frames, Distributed frames), and seismic zones have no influence on the ductility factors.