• 제목/요약/키워드: Ground faults

검색결과 224건 처리시간 0.026초

저항형과 유도형 한류기의 전류제한특성에 대한 EMTDC 해석 (EMTDC simulation for current limiting characteristics of the resistive and inductive SFCL)

  • 최효상;황시돌;현옥배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.255-258
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with 100 $\Omega$ of quench impedance for a single line-to-ground fault. which accounts for about 70% of the total power line faults, in the 154 kV transmission system. The fault simulation at the phase angles 0$^{\circ}$, 45$^{\circ}$, and 90$^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 12 KA, but with 3 kA of DC component which decreased to zero in 5 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

상호결합효과와 리액턴스효과를 제거한 765kV 비연가 송전선로 보호용 거리계전 알고리즘 (A New Distance Relaying Algorithm Immune to Mutual Coupling Effect and Reactance Effect for 765kV Untransposed Parallel Transmission Lines)

  • 안용진;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권1호
    • /
    • pp.25-30
    • /
    • 2005
  • An accurate digital distance relaying algorithm which is immune to mutual coupling effect and reactance effect of the fault resistance and the load current for the line faults in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for phase-to-ground fault and phase-to-phase short fault use a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kV untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

A Simulator for Potential Distribution Analysis

  • Kil, Gyung-Suk;Gil, Hyong-Jun;Park, Dae-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.225-229
    • /
    • 2012
  • This paper proposes a reduced-scale simulator that can replace numerical analytic methods for the estimation of potential distribution caused by ground faults in various grounding systems. The simulator consists of a hemispherical electrolytic tank, a three-dimensional potential probe, a grounding electrode, and a data acquisition module. The potential distribution is measured using a potentiometer with a position-tracing function when a test current flows to the grounding electrode. Using the simulator, we could clearly analyze the potential distribution for a reduced- scale model by one-eightieth of the buried depth and length of the grounding rod and grounding grid. Once both the shape of the grounding electrode and the fault current are known, the actual potential distribution can be estimated.

건물의 직격뢰시 본딩 방식에 따른 서지 진압 분포 (Surge Voltage Distribution at the Different Bonding Practice During a Direct Lightning Stroke to Building)

  • 이재복;장석훈;명성호;조연규
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.444-450
    • /
    • 2008
  • There are several ways to bond to building grounding systems for reducing GPR(ground potential rise) and EMI resulting from power system faults or lightning stroke to building. In order to verify effective bonding practice, the GPR and voltage of equipment due to the direct stroke to building are calculated with ATP-EMTP model for transformer, transmission line and MOV(Metal oxide varistor). The simulated model shows a satisfactory accuracy compared with experimental result for the $8/20{\mu}s$ simulated current pulse. It is observed that separate grounding can cause dangerous voltage to the building equipment and the performance of surge protective device can improve when it is installed to the protected equipment in distance as short as possible.

From the Isolation into the Community: The Dammed in Faulkner's Light in August

  • Han, SangJoon
    • 영미문화
    • /
    • 제14권1호
    • /
    • pp.311-335
    • /
    • 2014
  • Those who are damned in Light in August (1932) include Lena Grove, Joe Christmas as well as Gail Hightower. Through these characters, William Faulkner criticizes the confrontation between the North and the South after Civil War, religious fundamentalism, and racial discrimination which were great social issues in the twentieth century American society. The main characters are commonly isolated from the community through their grandfather's influence instead of father, which lets Americans understand that their faults originated from the beginning of America. Although they tend to approach to the community from their isolation, the damned are refused from the community. However, Faulkner would not lose his hope even on the ground of Christmas's death. By evoking from Hightower and Bunch their responses for good, Lena can draw Hightower into the community, and create her home with Bunch as a final victor. Even in the community being rampant with racial hatred, which most of Americans can not but face with, Faulkner can provide us with a ray of hope through these three characters.

플라이휠 에너지저장 장치를 이용한 전력보상 (Power Compensation by Flywheel Energy Storage System)

  • 김윤호;이경훈;박경수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.326-332
    • /
    • 1999
  • The flywheel generator in use as a power source for experimental device can be large enough to generate the electric power to make it suitable for application in wide rage of industries. The proposed system pruduces the good performance for power control. In this paper, the validity of the flywheel for power storage is described and the new control method which applies the space vector control scheme are proposed. This system is superior to conventional power compensator in the aspect of stability improvement and it is possible to make the converter capacity small. Continuous operation by flywheel can be realized even during power network faults such as 1-line ground.

  • PDF

IoT 기반의 결상사고 원격알람 시스템에 관한 연구 (A Study on Remote Alarm System of Open-phase Faults based on IoT)

  • 정회중;곽동걸;최신형;김춘삼;양기철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.4-6
    • /
    • 2018
  • This paper proposes an open-phase fault control system using 3-phase neutral voltage. The proposed control system is designed as a new topology which uses the potential difference between neutral point and ground(G) of three phase. And the open-phase detection system is configured to Y-wiring of three capacitance devices of the same capacity to each line of three phase power source R-S-T. This paper also designs a mobile phone application for remote alarm of open-phase fault.

  • PDF

Important Parameters Related With Fault for Site Investigation of HLW Geological Disposal

  • Jin, Kwangmin;Kihm, You Hong;Seo, Dong-Ik;Kim, Young-Seog
    • 방사성폐기물학회지
    • /
    • 제19권4호
    • /
    • pp.533-546
    • /
    • 2021
  • Large earthquakes with (MW > ~ 6) result in ground shaking, surface ruptures, and permanent deformation with displacement. The earthquakes would damage important facilities and infrastructure such as large industrial establishments, nuclear power plants, and waste disposal sites. In particular, earthquake ruptures associated with large earthquakes can affect geological and engineered barriers such as deep geological repositories that are used for storing hazardous radioactive wastes. Earthquake-driven faults and surface ruptures exhibit various fault zone structural characteristics such as direction of earthquake propagation and rupture and asymmetric displacement patterns. Therefore, estimating the respect distances and hazardous areas has been challenging. We propose that considering multiple parameters, such as fault types, distribution, scale, activity, linkage patterns, damage zones, and respect distances, enable accurate identification of the sites for deep geological repositories and important facilities. This information would enable earthquake hazard assessment and lower earthquake-resulted hazards in potential earthquake-prone areas.

Application of the Robust Control Theory to the Dynamic Voltage Restorer

  • Y. Chun;Kim, J.;J. Jeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.38.2-38
    • /
    • 2001
  • Recent trend of increasing automated factories needs supply of high quality power from the utilities. Among the items of the power quality, voltage sag can be compensated by Dynamic Voltage Restorer(DVR). The key feature of the DVR is high response with less transient period to recover from the voltage sag due to the lightning or line-to-ground faults. In this paper we report that H controller is very premising for the practical application to the controller of DVR. Experiment al results shown in this paper was obtained by applying the control algorithm to 20 kVA DVR system. The experimental set consist s of IGBT - based three phase inverter and the TMS320C32- 60 DSP used for main processor of the control board. T$\infty$ simulate the 50% voltage ...

  • PDF

파쇄대가 과대분포한 암반지역에서 터널의 거동특성에 관한 연구 (Analysis on the tunnel behavior characteristic in the excessive fractured zone distribution of rock area)

  • 박재원;이승호
    • 한국터널지하공간학회 논문집
    • /
    • 제18권4호
    • /
    • pp.341-354
    • /
    • 2016
  • 본 논문은 설계단계에서 지반조사와 수치해석을 통해 예측된 터널의 거동특성과 실제 시공단계에서 어떠한 변형특성을 보이고 있는지 RMR 및 계측데이터의 비교분석을 통해 선정된 터널지보시스템의 선택적 적용을 보여준다. 이는 파쇄대가 과대분포한 암반지역에 터널을 설치할 경우, 터널굴착지반의 거동은 지반의 특성과 보강공법 등의 영향에 따라 상이한 거동특성 때문이다. 그러므로, 본 연구에서는 지반설계자가 단층대 및 파쇄대가 과대 분포한 암반지역의 터널 설계시, RMR-계측 데이터 분석과 지반물성치 저감에 따른 매개변수 분석을 비교하여, 지반 설계자가 향후 유사한 파쇄대가 과대분포한 지역의 터널거동특성을 예측할 수 있도록 하고자 한다.