• 제목/요약/키워드: Ground current

검색결과 1,725건 처리시간 0.03초

축소모델을 이용한 구조체 접지 분석 (The Analysis of Structure Grounding Using Reduced Scale Model)

  • 길형준;김향곤;한운기;이기연;최충석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2046-2048
    • /
    • 2005
  • This paper deals with ground potential rise of structure grounding electrode when a test current flows through grounding electrode. In order to analyze the potential gradient of ground surface on structure grounding electrode, the reduced scale model has been used. The structures were designed through reducing real buildings and fabricated with four types on a scale of one-one hundred sixty. The supporter was made to put up with weight of structure and could move into vertical, horizontal, rotary direction. When a test current flowed through structure grounding electrodes, ground potential rise was the lowest value at electric cage type(type B). According to resistivity and absorption percentage in concrete attached to structure, the potential distribution of ground surface appeared differently.

  • PDF

탄소접지극 접지임피던스의 주파수의존성과 과도응답특성의 해석 (Analysis of Transient Response Behavior and Frequency-Dependent Ground Impedances of the Carbon Ground Electrodes)

  • 이복희;이강수;김유하;엄상현
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.54-61
    • /
    • 2013
  • This paper presents transient response behavior and frequency-dependent ground impedance of a single carbon ground electrode. The ground impedance of the carbon ground electrode was measured as a function of frequency of injected currents and simulated by using the distributed parameter circuit model with due regard to the frequency-dependent soil parameters, and the transient response behavior of the carbon ground electrode against impulse currents were investigated. As a consequence, the frequency-dependent ground impedance of the carbon ground electrode showed the capacitive behavior, that is, the ground impedance decreases with increasing the frequency of injected currents and lowers at the fast front time of impulse current. It was found that the carbon ground electrode is effective in grounding system for lightning protection. The ground impedance simulated with due regard to the frequency-dependent soil parameters was in good agreement with the measured data. The adequacy of the simulation technique and the distributed parameter circuit model for the carbon ground electrode was verified. It is expected that the simulation methodology, which analyzes the frequency-dependent ground impedance of the carbon ground electrode proposed in this work, can be used in the design of a grounding system for protection against lightning.

고성능 필터를 이용한 접지저항 측정시스템의 설계 (Design of the Ground Resistance Measuring System using high Performance Filter System)

  • 이기홍;정재기;주형준
    • 조명전기설비학회논문지
    • /
    • 제15권6호
    • /
    • pp.43-48
    • /
    • 2001
  • 본 논문에서는 지중의 노이즈들로부터 영향을 받지않는 접지저항 측정시스템을 설계하였다. 일반적으로 기존 의 접지저항 측정기는 지중에 노이즈가 잠재되어 있을 경우, 접지저항 측정신호가 영향을 받아 정확한 접지저항을 측정하기 어렵다. 따라서 본 논문에서는 L-C공진필터와 마이크로프로세서를 이용하여 지중의 잡음환경에서도 정확히 접지저항을 측정할 수 있는 접지저항 측정기를 설계하였다. 또한 현장시험을 통해 설계된 접지저항측정기가 지중의 노이즈로부터 영향을 받지않음을 입증하였다.

  • PDF

수치해석을 이용한 도로함몰 예측기법 (Prediction Method for Ground Collapse Using Numerical Simulations)

  • 김희수;반호기
    • 한국지반환경공학회 논문집
    • /
    • 제20권9호
    • /
    • pp.5-11
    • /
    • 2019
  • 최근 국내 도심지 지반침하 및 함몰이 빈번히 발생함에 따라 지반침하에 대한 불안감 또한 증가하고 있다. 그로 인해 GPR를 통한 지하 공동 탐지 지반함몰 모사실험 지반의 거동을 확인하기 위한 수치해석 등의 연구가 진행되고 있다. 국내의 경우 공동위험도 평가를 최근에 마련하였으나 현재의 지반상태 파악에 초점을 두었기 때문에 향후 발생할 수 있는 지반침하 및 함몰에 대한 예측을 정량적으로 하기 힘들다. 따라서 본 연구에서는 지반침하/함몰의 기하학적 변수인 공동크기와 토피두께를 변화시키며 총 30개의 case에 대한 수치해석을 수행하였다. 이 결과를 바탕으로 현재의 상태 뿐 아니라 향후 발생할 시기를 정량적으로 예측할 수 있는 방법을 제시하였다.

토양의 주파수의존성을 고려한 정보통신설비용 수평접지전극의 과도전위상승 분석 (Analysis of Transient Potential Rises of Horizontal Ground Electrodes Considering the Frequency-Dependent of Soil)

  • 안창환
    • 전자공학회논문지
    • /
    • 제53권2호
    • /
    • pp.147-153
    • /
    • 2016
  • 정보통신설비의 피뢰설계는 정보통신기기 동작의 신뢰성을 향상시키기 위해서 매우 중요한 요소이다. 특히, 뇌격전류에 의한 접지전극의 과도전위상승은 전원설비 및 정보통신기기의 절연내력의 기초 자료가 되기 때문에 정확한 해석이 요구된다. 접지전극의 과도전위상승은 접지임피던스로부터 계산되어지며, 접지임피던스는 접지전극의 형상과 토양의 주파수의존성에 크게 의존적이다. 토양의 주파수의존성은 인가된 전계에 의한 토양의 유전체 특성을 해석할 수 있는 디바이식을 적용하였다. 또한 접지임피던스로부터 과도전위상승을 계산하는 방법을 제시하였다. 디바이식을 적용한 과도전위상승 결과를 분석하기 위해서 전송선로 모델과 대지저항률이 일정한 경우에 대해서 각각 시뮬레이션을 수행하였다. 수평접지전극은 30 m이며, 표준 뇌격전류파형에 대해서 대지저항률이 10, 100, $1000{\Omega}{\cdot}m$에 대해서 각각 분석하였다. 그 결과 디바이식을 적용하여 계산된 수평접지 전극의 과도전위상승이 다른 모델의 경우보다 더 낮게 나타났다.

직류전기철도 레일-대지간 절연저항 측정 방안 (Consideration of Conductance between Rails and Ground in DC Railway)

  • 한문섭;김주락;정호성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.166-168
    • /
    • 2008
  • DC feeding system is mainly floating but the rail potential and the leakage current are created because of long parallelism between rails and ground. Rail potential causes electric shock to human and leakage current causes electrolytic corrosion to nearby the buried metals. Therefore the design technologies to reduce, protect and monitor these effects are important recent DC feeding system. Rail potential and leakage current are analysed based on propagation theory that is utilized in order to simulate grounding system. New measurement procedure is proposed based on this analysis in order to more be accurate in result.

  • PDF

학교 컴퓨터실의 전기안전에 대한 리스크요소 평가 (Assessment of Risk Component for Electrical Safety of Computer Room in School)

  • 길형준;김동욱;이기연;김향곤;최충석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.440-445
    • /
    • 2007
  • This paper deals with assessment of risk component for electrical safety and investigation on the spot of computer room in elementary middle high school. The investigation was carried out side by side for floor, outlet, panel board, earth leakage circuit breaker at computer room In order to assess electrical safety at computer room, grounding simulator and power quality monitor have been used. Potential rise has been measured and analyzed for ground rod and grounding grid by using the simulator. Phase and neutral-line current have been monitored in real time. As a consequence, it is desirable for us to install conductive tile at floor of computer room Grounding grid had better than ground rod for electrical safety. Neutral-line current was produced by unbalanced phase current.

  • PDF

3상 전력계통의 1선 지락사고에 대한 초전도한류기의 동작특성 (Operating properties of superconducting fault current limiters with a sing1e line-to-ground fault in a three-phase system)

  • 최효상;현옥배;김혜림;황시돌;차상도
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.261-262
    • /
    • 2003
  • We performed unsymmetrical analysis of a single line-to-ground fault in a three-phase system. The current limiting elements were meander type YBCO stripes coated with Au shunt. When the fault occurred, short circuit currents were effectively limited within 1-2 msec after fault instant. The unsymmetrical rate of fault phase was distributed from 6.4 to 1.4 and most of the fault current flowed in the grounding line due to its direct grounding system.

  • PDF

임펄스 전류에 대한 대규모 접지시스템의 과도접지임피던스 (Transient Impedance of Large-scale Grounding System under Impulse Current)

  • 이복희;엄주홍;이승칠;최원규;박종순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1589-1591
    • /
    • 1998
  • This paper presents experimental results of transient impedance characteristics investigated on the site of a large-scale grounding system using impulse current. The ground potential rise was measured while injecting an impulse current and the transient impedance was determined. As a results, the transient impedance was significantly greater than the stationary grounding resistance due to high inductance of ground conductors and leads.

  • PDF

단상 재폐로시 2차아아크 전류의 감소방법에 관한 연구 (A Study on the Decreasing Method of Secondary Arc Current on Single Phase Reclosing)

  • 김준현
    • 전기의세계
    • /
    • 제26권6호
    • /
    • pp.59-65
    • /
    • 1977
  • A study on the decreasing method of secondary arc current on single phase reclosing. One of the major problem in case of using the single phase reclosing scheme for long distance UHV transmission line is the time required to deionize secondary arc current. This paper descritbes the way of inducing the formular of secondary arc current originated at the times of opening and closing the ground interrupting switch. The result was investigated by the method of numerical analysis and proved that the secondary arc current was decreasing sufficiently. Application of this method proposed by the authod makes it possible to deduce the dead time and to improve success-rate of reclosing.

  • PDF