• Title/Summary/Keyword: Ground current

Search Result 1,725, Processing Time 0.031 seconds

Analysis for Pole to Ground Fault Detection in Ungrounded LVDC Distribution Network (비접지 LVDC 배전망의 지락고장 검출을 위한 분석)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.119-124
    • /
    • 2018
  • Recently, LVDC distribution network and DC microgrid with many advantages are being built. However, this LVDC distribution is an IT grounded or ungrounded system, and it is difficult to detect a ground fault because the fault current is small. In this paper, we propose a signal injection method for unipolar LVDC distribution network to detect ground fault in ungrounded LVDC distribution, and various analyzes were performed for ground fault detection.

Touch Voltage According to the Distance between Distribution Concrete Pole and Ground Rod (배전용 전주와 접지전극의 이격거리에 따른 접촉전압)

  • Lee, B.H.;Jung, H.U.;Lee, T.H.;Baek, Y.H.;Lee, D.M.;Jung, D.C.;Lee, K.S.;Ahn, C.H.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.391-394
    • /
    • 2005
  • This paper describes the touch voltages and potential distributions according to the distance between distribution concrete pole and ground rod when the current is injected to a ground rod through overhead ground wire. Touch voltage is measured in four directions. The touch voltage and ground potential distribution per 1 A are analyzed. The touch voltage was the highest at the around surface just above the ground rod.

  • PDF

Effective impulse impedances of a deep-driven ground rod combined with other grounding electrodes (다른 형상의 접지전극에 접속된 심매설 접지전극의 실효임펄스임피던스)

  • Lee, Bok-Hee;Chang, Keun-Chul;Lee, Su-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.565-569
    • /
    • 2004
  • This paper deals with the characteristics of potential rise and effective impulse impedance of deep-driven ground rods that are used in high resistivity soil or in confined places such as downtown. Also the effects of the impulse and fault currents on the deep-driven ground rods combined with different type grounding electrodes like as mesh grids and counterpoises are described. The $8/20{\mu}s$ impulse current and other wave currents with different rise times are injected into the test ground rod and the effective impedances are examined. The most effective way to obtain the fine transient impedance behaviors of deep-driven ground rods is to reduce the inductive component of grounding electrode systems combined with other ground electrodes.

  • PDF

A Study on Trouble and Arrangement of the Ground-Fault Protection for 2 Step Voltage Distribution System of Premises (2 Step 이상 운용 고객의 구내배전계통 지락보호시스템 구성 현황 및 문제점 검토)

  • Im, Jin-Sung;Shin, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.73-77
    • /
    • 2010
  • Most accidents occurred in power receiving & transforming facility are ground fault. The quality of power supply is deteriorated since the ground fault is not detected promptly. This paper analyzes the problems about system-grounding type of 2 step power receiving & transforming facility, arrangement of protection relaying scheme and ground-fault protection system of ungrounded system. Then, this paper presents the arranging scheme of system-grounding type to improve power supply reliability.

Potential Distribution near Street Linght according to the Grounding Electrode (접지극 형상에 따른 가로등 주변의 전위분포)

  • Lee, Bok-Hee;Beak, Young-Hwan;Jeong, Dong-Cheol;Ahn, Chang-Hwan;Shim, Pan-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1453-1454
    • /
    • 2007
  • A street light is an electrical equipment to improve the traffic safety and the security for people in night. However, many accidents due to electric shock have happened in recent, people were interested in the safety of electrical facilities. And people want to know the danger by touch and step voltages. When the electric power lines fall down on the ground, the fault current flows to ground rod and the potential near the ground rod is increased to induce the high touch and step voltages. In this paper, we installed different ground rods with a street light and investigated the electrical potential according to ground methods and the types of ground rod. Finally, we examined the electrical facilities with the experimental result and present the improved technical data for the safety from electric shock

  • PDF

Grounding method for Improving of the Characteristics on Cable TV Transmission Line (케이블 TV 전송선로의 특성 개선을 위한 접지방식)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Yeon, Che-Chin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.37-40
    • /
    • 2002
  • Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in cable TV.

  • PDF

Analysis of the Grounding Impedance of a Ground Rod Considering the Frequency-Dependent Resistivity and Relative Permittivity of Soil (토양의 저항률 및 비유전율의 주파수의존성을 고려한 접지봉의 접지임피던스의 해석)

  • Ahn, Chang-Hwan;Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.54-60
    • /
    • 2012
  • When the transient current with high frequency components such as lightning surges are injected the grounding electrodes, the performance of grounding electrodes should be evaluated as grounding impedance. It is restricted to analyze the grounding impedance by measurement approach since the grounding impedance is very different with the shape and size of grounding electrodes, resistivity and relative permittivity of soil and the frequency component of the injected current. So a variety of simulation approaches have been developed. Typically, the soil resistivity measured with low frequency and relative permittivity between 1 and 80 are used for simulation of the grounding impedance. However, the resistivity and relative permittivity of soil are changed with frequency of injected current. In this paper, the frequency-dependent resistivity and relative permittivity of soil are measured and these parameters are reflected in the simulation of the grounding impedance of a ground rod. The simulated results are compared with the measured results. As a result, the simulated results with frequency-dependent soil parameters show capacitive aspect like measured results in the frequency of lower than 100[kHz] and they are more consistent with the measured results in wide frequency range.

Analysis of Risk Voltage for Grounding Electrode by Injection of Earth Leakage Current

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon;Kil, Gyung-Suk
    • International Journal of Safety
    • /
    • v.8 no.2
    • /
    • pp.9-14
    • /
    • 2009
  • This paper describes analysis of risk voltage for grounding electrode where earth leakage current is injected. To assess risk voltage of grounding electrode, the grounding simulator and CDEGS program were used to obtain measured data and theoretical results of this study. The grounding simulator was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The shapes of grounding electrode model was ground rod. The potential rise was measured by grounding simulator, and the touch and step voltages were computed by CDEGS program. As a consequence, the potential rise of ground rod abruptly decreases with increasing the distance from the grounding electrode to the point to be tested. The touch voltage above the ground rod was low, but the step voltage was high. The measured results were compared with the computer calculated data and were known in good agreement.

The Implementation of the system-on-board controllable the electrical fires due to ground fault, arc fault and overload (누전, 아크, 과부하에 의한 전기화재 제어 시스템 보드의 구현)

  • Kim, Byung-Cheul;Chun, Joong-Chang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.419-424
    • /
    • 2011
  • The system-on-board detectable and controllable the electrical fires due to ground fault(GF), arc fault and overload is implemented. The system IC for controlling and preventing the electrical fires is available to this system. The GF detection circuit for detecting the electrical leakage current, the arc fault detection circuit and the overload detection circuit controllable the input voltage for flowing the overload current are designed. The GF detection circuit and the arc fault detection circuit are good operated to the electrical leakage current and the arc signal, respectively. It is confirmed that the overload detection circuit has shown no erratic operation with the noise or the load variation and is only operated at the overload condition.

Transient Characteristics of a Transformer Type SFCL Applying the Superconductor and the Normal-conductor into the Secondary Winding (초전도체 및 상전도체의 변압기 2차측 적용에 따른 변압기형 SFCL 특성 비교)

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.873-877
    • /
    • 2016
  • This paper proposed the structure that applied superconductors to the neutral line of a transformer and applied the normal conductors to the third line. The superconductor applied to the neutral line of a transformer limited the peak value of initial fault current, while the normal conductor finally limited the fault current. In order to secure the operating reliability of transformer type Superconducting Fault Current Limiter (SFCL) of previously proposed structure, we analyzed the operating characteristics according to the fault types. We tested a line-to-ground fault and a line-to-line fault. As a result of the experiment, all the faults showed that the superconductor stably limited the peak-value of initial fault current. Also, the normal conductor finally limited the fault current. Based on this research results, We thought that if the structure of inserting superconductor into the neutral line is applied to the real system, it could improve the reliability and stability of the power system.