• 제목/요약/키워드: Ground Water

검색결과 3,604건 처리시간 0.029초

지하수 흐름을 고려한 지하구조계의 탄소성해석에 대한 전-후처리기법의 개발 (Development of Pre-Postprocessing Toolbox for Elasto-plastic Analysis of Underground Structures with Water Flow)

  • 김문겸;임성철;이재영;송재성
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.79-86
    • /
    • 1997
  • In this study, pre-postprocessing toolbox is developed to perform elasto-plastic analyze of underground structures with transient ground water flow. This toolbox is composed of three modules. The first is the data input processor for the structural analysis. The preprocessing Is using GUI (Graphic User Interface), which is consist of dialog box, pull down, and short-cut icon, etc. The second is the structural analysis module. The analysis is based on the elasto-plastic finite element method involving additional options such as ground excavation effect, transient ground water flow, and rock bolts behavior. The last is the postprocessing module. The postprocessing is able to verify the result of the structural analysis by the graphical simulation which visualizes the element mesh, the node displacements, the element stress states, the stress contour, the ground water surface, and the rock bolt stresses. Since various options are considered separately in this toolbox, it is easy to modify the module of each processing, and to update other functional modules for the given analysis conditions.

  • PDF

서울 일부지역 정호수의 망간, 크롬함량 조사연구 상수시설 미설치지역을 중심으로 (A Study on the Content of Manganese and Chrome in the Ground Water in Seoul Area (Based on non-water supply area))

  • 구성회;우세홍;이성호;이부웅
    • 한국환경보건학회지
    • /
    • 제1권1호
    • /
    • pp.41-45
    • /
    • 1974
  • A study was carried out to determine the content of Mn and Cr in the ground water in Seoul area, where municipal water supply system was not installed, from Nov. 1 to Nov. 30, 1973. In this study, authors examined the hardness, pH, water temperature and Cl ion to investigate the general conditions of the ground water. For this study, samples were collected from 46 wells which were located in outpart of Seoul city, and Mn and Cr were determined with the Spectronic-20. The following results were obtained: 1) Average value of the ground water conditions of the wells were 13.3$\circ$C in temperature, pH 6.3, hardness 159 ppm and Cl ion 41 ppm. 2) In the manganese concentration, the highest area was Yeongdeungpo-Ku(0.318 ppm), while the lowest area was Sungbuk-Ku(0.065 ppm) and the mean concentration of the whole district was 0.196 ppm. 3) In the chrome concentration, the highest area was Yeongdeungpo-Ku(0.031 ppm), while the lowest area was Dobong-Ku (trace) and the mean concentration of the whole district was 0.012 ppm.

  • PDF

개방형 지열 히트펌프 시스템의 운전 특성 (Operation Characteristics of Open Type Geothermal Heat Pump)

  • 임효재;공형진;송윤석;박성구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.701-706
    • /
    • 2006
  • Groundwater heat pump systems are the oldest of the ground-souce systems and it has various type. Standing column well type are must be located in hard rock geology site and produce sufficient water for the conventional open loop system. These system are indirect type(the building circulating loop and ground water are intercept). Existence of the exchanger the foundation protect water quality to use of open loop. The design of open loop system are concern on the power requirements. An experimental study was analysis the extremely heating operation COP of ground water heat pump system. Operation efficiency of the 50RT systems shows that, COP $2.9{\sim}5.0$ in heating operation. And generally it shows 3.4.

  • PDF

TDR센서를 이용한 제방의 포화도 및 지하수위 해석 (Analysis of Saturation and Ground Water level in The Embankment Using TDR Sensor)

  • 박민철;김기영;이재호;한희수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.404-415
    • /
    • 2010
  • In this paper, using the TDR sensors, variation of soil water content changes were measured as TDR data. Then filtering technique was determined using Fourier transform. Determine the moisture content of soil and ground water level and tried to determine unsaturated zone. First, variation of water content changes were measured TDR data by indoor experiment. Then as a function of TDR data made for water content of soil. Next, through Acrylic indoor laboratory model experiments, changes in ground water levels and lateral penetration of the field conditions were reproduced in an indoor. Field applicability of the TDR sensor was demonstrated by analysis of this. TDR sensor was installed in the embankment, TDR data were measured by TDR sensor.

  • PDF

지중열교환기 뒤채움재로 사용되는 모래-물 혼합물의 열전도도 예측 (Predicting the Effective Thermal Conductivity of Some Sand-Water Mixtures Used for Backfilling Materials of Ground Heat Exchanger)

  • 손병후
    • 설비공학논문집
    • /
    • 제20권9호
    • /
    • pp.614-623
    • /
    • 2008
  • This paper presents the results of a laboratory study on the thermal conductivity of and(silica, quartzite, limestone, sandstone, granite and two masonry sands)-water mixtures used for ground heat exchanger backfilling materials. Nearly 260 tests were performed in a thermal conductivity measuring system to characterize the relationships between the thermal conductivity of mixtures and the water content. The experimental results show hat the thermal conductivity of mixtures increases with increasing dry density and with increasing water content. The most widely used empirical prediction models for thermal conductivity of soils were found inappropriate to estimate the thermal conductivity of unsaturated sand-water mixtures. An improved model using an exponential relationship to compute the thermal conductivity of dry sands and empirical relationship to assess the normalized thermal conductivity of unsaturated sand-water mixtures is presented.

관개수원에 따른 논에서의 영양물질 배출 특성 (Characteristics of Nutrient Export from Paddy Rice Fields with Irrigation Practices)

  • 황하선;공동수;신동석;전지홍
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.597-602
    • /
    • 2004
  • Field experimental study was performed to examine characteristics of nutrient export from paddy rice fields with irrigation practices. Experimental fields with surface-water and ground-water irrigation were monitored and analyzed during rice culture period. The water balance showed that outflow generally balanced the inflow showing that about half (58~68%) of total outflow was lost by surface drainage. Water and nutrient export are more in surface-water irrigation paddy than in ground-water irrigation paddy. The reasons might be more irrigation water available and easy to use in surface-water irrigation. If irrigation water reduced, it could result in reduction of nutrient export in paddy rice fields, which can save water and protect water quality. However, deviation from conventional standard practices might affect the rice yield and further investigations are necessary.

압력도수터널 콘크리트 라이닝 구조 계산시 외수압 처리에 관한 연구 (A study on the treatment of external water pressure for the water pressure tunnel at the structural analysis of concrete lining)

  • 이현섭;이영준;서승우;황영철
    • 한국터널지하공간학회 논문집
    • /
    • 제17권6호
    • /
    • pp.653-664
    • /
    • 2015
  • 압력도수터널 콘크리트 라이닝 구조계산시 암반의 이완하중, 내수압, 외수압, 건조수축, 그라우팅압 등 다양한 하중조건을 고려하는데, 아직까지 국내에는 압력도수터널에 대한 콘크리트 라이닝 구조해석을 위한 설계기준 및 체계적인 매뉴얼이 없으므로 설계자에 따라 다르게 적용되고 있는 실정이다. 특히, 도수터널은 외수압을 저감시키기 위해 Weep Hole을 설치하는 경우도 있는데, Weep Hole 설치로 인해 많은 문제점이 야기될 수도 있으므로 Weep Hole을 설치하지 않을 시 외수압 처리에 대한 합리적인 접근 방법이 필요하다. 따라서, 본 논문에서는 압력도수터널 콘크리트 라이닝 구조 계산시 외수압 처리에 대해 기존 설계사례 및 문헌 등을 분석하여 합리적이고 적절한 설계개념에 대하여 서술하였다.

경부고속철도 천성산구간 원효터널공사와 늪지와의 상관성 분석 (Analysis of Correlation Between Wonhyo Tunnel(section of KTX line) Works and Swamp)

  • 함동선;김병호;전병규;김인수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1838-1844
    • /
    • 2007
  • The Wonhyo Tunnel on KTX railroad line is a section of latest concerns from domestic environmental NGOs, which focus on potential destruction of ecosystem or the like due to ever-depleted swamp water at about 300m upward from the tunnel under construction. As a result of study, out of all swamps in the vicinity of the tunnel, it was found that Mujechi 1st and 2nd swamps have been getting smaller in their area little by little since 50 years ago primarily under the influence of eroded streams around lower swamp and even ever-increasing annual mean temperature. As the result of monitoring about swamp before work, it was found that swamp water depends absolutely on amount of rainfall. Besides, the results of monitoring during work also didn't show any leakage generated in the tunnel during and after excavation works with regard to a wheat field swamp in the most vicinity of the tunnel (80m away). On the other hand, it was found that the range affected by ground water sink in tunnel section without grouting process amounted to about 100m around the tunnel, which indicates that such ground water sink has no significant impact upon most of swamps near the tunnel. As the result of testing by two well tracer test around swamps, it was noted that swamp water didn't run out from the bottom of swamp even with adjacent ground water level sunk in factitious ways. And the results of physical survey showed that swamp kept saturated even in dry season when ground water level becomes lower than the bottom of swamp. Therefore, even supposing that ground water level becomes sunk due to tunnel works, it is estimated that the water level of swamps would be still kept owing to impervious layer(peat beds).

  • PDF

국내 지열원 히트펌프 유닛의 인증제도 분석을 통한 신뢰성 향상 방안 연구 (A Study on Reliability Improvement of Domestic Ground Source Heat Pump Units by Analyzing the Certification System)

  • 양찬우;강희정;오세왕;도우빈;이광호;최종웅;조용;최종민
    • 신재생에너지
    • /
    • 제19권4호
    • /
    • pp.72-83
    • /
    • 2023
  • Only ground source heat pump units certified according to the regulations in Korea can be adopted in ground source heat pump systems. In this study, domestic and international standards and regulations for ground source heat pump units were investigated. Unlike ISO 13256-1~2, which is the international standard, KS B 8292~8294 for ground source heat pump unit only included rated test conditions. Therefore, it is necessary to supplement various test conditions to the KS B series, because its performance data, which is required to calculate the system's design capacity, is dependent on the change in entering water temperature. The difference between the coefficient of performance of the certified ground source heat pump units and the certified criteria changed significantly according to the operating mode, heat source, and load type, because the criteria increased by about 5% for all. Thus, it is highly suggested that the certification standards be revised while considering the product performance level and various conditions.

수중에 잠긴 접지전극 주변에서의 이온화에 의한 전위저감 및 에너지방출 (Potential Reduction and Energy Dispersion Due to Ionization Around the Submerged Ground Rod)

  • 최종혁;안상덕;양순만;이복희
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.92-99
    • /
    • 2009
  • 심매설 접지봉의 경우 장마철에 빗물이나 지하수와 접촉하는 경우가 발생한다. 수중에 잠겨있는 접지극에 서지 전압이 인가되면 접지극 주변에서 이온화 현상이 발생하게 된다. 지중이나 수중에서의 이온화 현상은 접지 시스템의 에너지적인 특성에 의해 영향을 받는다. 이 논문의 목적은 축소된 전해 수조를 이용하여 임펄스 전압에 의한 접지시스템의 과도특성을 파악하는데 있다. 매틀랩 프로그램을 활용하여 이온화에 의한 전위저감과 방출된 에너지를 측정하여 정량적인 분석을 수행하였다. 접지극 끝단의 최대 전압은 물의 저항률과 Marx형 전압발생장치의 충전전압에 따라 다양하게 나타났다. 접지극 끝단의 전위는 절연파괴전압에 이르기 전 인가전압에서 대략 절반까지 감소하였다. 또한 절연파괴가 발생하기 전 인가된 에너지의 절반 이상의 에너지가 이온화에 의해 접지극을 통하여 방출되었다.