• Title/Summary/Keyword: Ground Injection

Search Result 288, Processing Time 0.027 seconds

Frequency Dependance of Ground Impedances of the Counterpoises (매설지선 접지임피던스의 주파수 의존성)

  • Choi, Young-Chul;Choi, Jong-Hyuk;Kim, Dong-Kyu;Lee, Gyu-Sun;Yang, Soon-Man;Lee, Su-Bong;Lee, Bok-Hee;Ahn, Chang-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1489_1490
    • /
    • 2009
  • Ground impedance is changed according to frequency of the current injected into the grounding system. Because the lightning surge gives a broad frequency spectrum from some ten Hz to a few MHz, frequency dependance of ground impedance must be evaluated. In this paper, we have constructed 10m, 30m, 50m counterpoise and evaluated frequency dependance of ground impedance. Also we have evaluated frequency dependance of ground impedance according to current injection point. As a result, long counterpoises have low ground resistance, but ground impedances of those are significantly increased in the range of high frequency. In the case that currents are injected into the center of counterpoise, the ground impedance is most lower than any other injection point. Also, additory ground rod of 1.8m long affect ground impedance decrease.

  • PDF

The Application and Geo-Enviromental Effect on TAS Method (TAS공법의 적용성과 지반환경 영향)

  • Chun, Byung Sik;Yeoh, Yoo Hyeon;Baik, Jung-Shik;Choi, Choon-Sik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.3
    • /
    • pp.27-36
    • /
    • 2002
  • Generally, it is known that urethane injection is excellent in long-term durability and environment friendly for ground improvement. However, urethane grouting has short rise time thus the penetration distance from the injection point is so short. Therefore, urethane injection cannot be used for the site where requires ground improvement in deep location from the injection point. Other injection materials such as cement cannot be alternatives when rapid hardening is required. From this study, we improve disadvantage urethane injection by developing TAS method. From the field tests, it is ascertained that TAS increases injection distance over 10m, which is further than that of original urethane grouting. In addition, TAS has relatively short Rise-time compared to cement grouting thus instantaneous improvement can be mobilized right after the injection. Short Rise-time and long penetration distance provide excellent applicability for tunnel construction.

  • PDF

A Study on the Injection Efficiency and Strength for Grouting Method (그라우팅공법의 최적 주입비와 강도에 관한 연구)

  • Kim, Sang-Hwan;Kim, Tae-Kyun;Choi, Jae-In;Yim, Ki-Woon
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.9
    • /
    • pp.47-58
    • /
    • 2010
  • This paper presents the injection efficiency of 2.0 shot system which was verified by strength and injection time. In order to perform this study, laboratory model tests and field tests are carried out. The laboratory model tests consist of the test of injection time for verifying the injection ratio, and the tests of homo-gel and sand-gel strengths for estimating the characteristic of strength. It is found that the injection ratio of 1:2 shows the best seepage into the ground. The results of the strengths are also larger than other injection ratio. The large strength will also be expressed by field tests at construction site.

The transient grounding impedance measurment of large grid grounding electrodes (대규모 그리드 접지전극의 과도접지임피던스의 측정)

  • Jeon, Byung-Wook;Lee, Su-Bong;Li, Feng;Lee, Seung-Ju;Jung, Dong-Cheol;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.69-72
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of large grid grounding system associated with the injection point of impulse current The measurement methods consider two possible errors in the grounding-system impedances: (1) ground mutual resistance due to current flow through ground from the ground electrode to be measured to the current auxiliary, (2) ac mutual coupling between the current test lead and the potential test lead The test circuit was set to reduce the error factors. The transient grounding impedance depends on the rise time and injection point of impulse current It is effective that grounding conductor is connected to the center of the large grid grounding system.

  • PDF

A Study on Characteristics of Urethane Polymer as Injection Material for Ground Improvement

  • Chun, Byung-Sik;Park, Heung-Kyu;Ryu, Dong-Sung
    • Geotechnical Engineering
    • /
    • v.12 no.3
    • /
    • pp.99-108
    • /
    • 1996
  • The physical and chemical properties of polyurethane-yieding twofomponent liquid injection mixture and those of the resulting polyurethane solid foam for chemical grouting are investigated. The chemical experiments on the factors influencing the properties of polyurethane show that the behaviors of polyurethane-yielding liquid material and those of the produced polyurethane solid foam are greatly affected by the ground conditions such as temperature, water content and density of soil. The ground reinforcing and water -blocking effects of polyurethane grouting are examined through field case history of tunnel ericavati on of the subway under construction.

  • PDF

A Study on Soil Improvement Effects under Poor Ground Conditions (열악한 지반조건에서 고질공법의 지반보강효과 증대에 관한 연구)

  • 천병식;최기성
    • Geotechnical Engineering
    • /
    • v.12 no.2
    • /
    • pp.115-132
    • /
    • 1996
  • Several soil improvement methods are applied to stabilize soft ground. But, their improvement effects are known to be reduced in view of strength and durability under poor conditions such as marine clay and the ground with the flow of groundwater. The soil improvement method is generally classified as mixing(high pressure) type and injection type, and in this study, for successflll'applications of gelling methods, first in case that mixing method with cement is applied to marine clay, the causes of strength inferiority of treated soil are analyzed, and the effectiveness of improvement is studied, second in case that injection method with water-glass chemical grouts is applied to the ground with the flow of groundwater, soil improvement effects and durability of grouted soil are studied.

  • PDF

A Study on the Behavior Characteristics of Soft Clay Ground by C.G.S Method (C.G.S공법을 적용한 연약점토지반에서의 거동특성에 관한 연구)

  • 천병식;여유현
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.307-323
    • /
    • 2003
  • In this study the pilot test of C.G.S (Compaction Grouting System) as injection method by low slump mortar was performed and the results were analyzed in order to find out the application of this method to the soft ground and the effect of settlement restraint. The site for pilot test is adjacent to apartments supported by pile foundations. Sand drain method was performed previously as countermeasures against settlement, but settlement occurs continuously because this ground is very soft. Site investigations such as SPT, CPT and vane shear test were performed to determine the characteristics of ground improvement after the installation of C.G.S. Field measurements were performed on purpose to find out the displacement of ground during the installation of C.G.S. From the results of this study, C.G.S method can be optimized by the control of radius, space, depth, injection material and injection pressure. C.G.S improves soft ground with radial consolidation of adjacent soft ground. Considering that increase of N value to about 3, C.G.S can be considered as an effective method to increase the bearing capacity as well as constrain the settlement of soft ground. It is also expected to be economic and effective in the improvement of ground when it is used in applicable sites.

A Study on the Ground Reinforcement of Jeju Scoria Layer by Chemical Grouting (약액주입에 의한 제주도 송이지층의 지반보강에 관한 연구)

  • Yang, Kiho;Park, Jeongjun;Kim, Younghun;Byun, Yoseph;Lee, Eunjong;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.2
    • /
    • pp.75-82
    • /
    • 2014
  • Recently, public works becoming bigger in Jeju are implemented various kinds of ground reinforcement method including the chemical grouting method. In this study, we have been investigated on the proper material and the injection condition for the excellent injection effect and the excellent strength of injection material and the permanent waterproof and reinforcement through the experiment. The kind of injection material has been selected through the uniaxial compression test and the endurance test of injection material as the chamber test. An experiment was performed with model ground made of scoria, the injection performance of selected material has been identified through the evaluation test of injection range using the decision test of injection amount and the calibration chamber test. As a result of test, it has been analyzed that MSG appeared to have the excellent strength, durability and injection performance all compared with the ordinary cement, this result is judged to be possible as the ancillary data of design at time of design and construction with the chemical grouting method in the future.

Behaviors of Impulse Ground Impedances Associated with the Current Injection Point in a Ground Rod (봉상 접지전극에시 전류유입위치에 따른 임펄스 접지임피던스의 특성)

  • Lee, Bok-Hee;Jeong, Dong-Cheol;Lee, Su-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.94-100
    • /
    • 2005
  • This paper presents the behaviors of transient and effective impulse impedances of a long ground rod associated with the current injection points. The laboratory test for the time domain performance of actual-sized model ground rod subjected to a lightning stroke current has been carried out The transient ground impedances of long ground rods under impulse currents were higher than the ground resistance. Both of the ground resistance and the effective impulse ground impedance decrease with increasing the length of the ground rods. Also, the effective impulse ground impedances are significantly increased in fast rise time ranges. The reduction of the ground resistance is decisive to improve the impulse impedance characteristics of grounding systems. When the test current is injected at the bottom of ground rod, the oscillating pulses with high frequency are included on the wave front of ground rod potential and the effective impulse impedances are higher than any other cases.

Improvement of Grouting by Short-period Vibration Energy (단주기 진동에너지에 의한 그라우팅 보강효과)

  • Seo, Moonbok;Kwon, Sanghoon;Lee, Bongjik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.7
    • /
    • pp.35-42
    • /
    • 2015
  • Grouting method has been widely used for the ground improvement and stabilization: mostly to block or control the ground water in the early years and to improve the ground, repair the structure in recent years, ever increasing its use. Despite many advantages so far, the existing grouting method also has some shortcomings including uncertain permeation of grouting with gravity type if the voids between the soil particles are narrow, and problems due to the relaxation of the neighboring ground when injected using injection pressure. As an alternative, a vibration injection method with constant amplitude and frequency has been developed in recent years, with the vibration grouting being reported to have a permeability increasing effect of grout material compared with the positive pressure injection type. Accordingly, the purpose of this study is to investigate the improvement effect of the vibration grouting that applies short-period vibration energy by varying vibration cycle, vibration time and ground conditions to evaluate the strength enhancing effect of grouting materials, expansion effect of grouting body, ground improvement effect of the grouting and the penetration characteristics of the rock joint. The findings of this study show the improved compressive strength of grout, expansion of grouting body and increased penetration rate, according to the vibration compared with non-vibration under the loose soil condition.