• Title/Summary/Keyword: Ground Area

Search Result 3,405, Processing Time 0.03 seconds

Application of electrical resistivity for assessing characterizations of frozen and unfrozen soils

  • Dae-Hong Min;Hyung-Koo Yoon
    • Geomechanics and Engineering
    • /
    • v.38 no.2
    • /
    • pp.205-214
    • /
    • 2024
  • Permafrost refers to the condition where the ground is frozen. It is crucial to review and evaluate the ground's characteristics before construction. In this study, electrical resistivity surveying is chosen as the investigative technique to apply and illustrate the results on the state of permafrost ground and to summarize its applicability. Field experiments are conducted in the Yeoncheon area of South Korea, which has a freezing index of 522.6°C·days. The target area is categorized into two ground conditions: the first where the original ground freezes, and the second involves excavating the original ground up to a depth of 3 meters, backfilling it, and then artificially injecting fluid. Thus, frozen ground conditions are simulated under both natural and artificial circumstances. Electrical resistivity surveys are performed under both above-freezing and sub-zero temperature conditions, with the experiments conducted at sub-zero temperatures revealing relatively more high-resistivity zones due to the temperature conditions. In this area, the distribution of soil moisture content is also investigated using the Time Domain Reflectometry (TDR) technique. It is observed that the ground into which water is artificially injected had a relatively higher moisture content, although the difference is minor. Finally, a 3D map of the target ground is constructed based on the measured electrical resistivity values, and through this, the distribution of porosity, a crucial design parameter, is also depicted. This research demonstrates that the electrical resistivity technique can effectively evaluate the state of frozen and unfrozen ground and further suggests that it can detailed extract the characteristics of the target ground.

Performance Analysis of Ground Thermal Conductivity by Ground Heat Exchanger (지중열교환기의 지중열전도도 성능 분석)

  • Kim, Young-Jun;Choi, Jae-Sang;Kang, Yong-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.161-166
    • /
    • 2005
  • The objectives of this paper are to estimate the ground thermal conductivity by ground heat exchangers in two different places - Chooncheon and Wonjoo, and to analyze the effect of ground thermal conductivity on the ground thermal diffusivity and the size of the ground heat exchanger. In Chooncheon area, a single-U type HDPE pipe (25mm diameter) with borehole diameter of 150mm, length of 150m is installed. In Wonjoo area, a single-U type HDPE pipe (40mm diameter) with borehole diameter 150mm, length of 200m is installed. It is found that the ground thermal conductivities are estimated as 2.69 $W/m^{\circ}C$ and 2.99 $W/m^{\circ}C$ in Chooncheon and Wonjoo, respectively. It is also found that the ground heat exchanger size is reduced by 8.6% with 25% increase of ground thermal conductivity, and increase by 11.8% with 25% decrease of ground thermal conductivity.

  • PDF

Experimental Study on Stress Sharing Behavior of Composition Ground Improved by Sand Compaction Piles with Low Replacement Area Ratio (저치환율 모래다짐말뚝에 의한 복합지반의 응력분담거동에 대한 실험적 연구)

  • 유승경
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.253-261
    • /
    • 2003
  • Mechanical behavior of composition pound improved by sand compaction pile (SCP) with low replacement area ratio could be more significantly affected by mechanical interaction between sand piles and clays than that of clay ground improved by SD or SCP with high replacement area ratio. It is essential to elucidate the mechanical interaction in the improved clay ground, in order to accurately estimate behavior in reducing settlement of the improved ground and increasing strength of clays. In this paper, through a series of model tests of composition ground improved by SCP with low replacement area ratio, each mechanical behaviors of sand piles and clays in the composition ground during consolidation was elucidated, together with stress sharing behavior between sand piles and clays.

Environmental Isotope-Aided Studies on Water REsources in the Region of Cheju (동위원소를 이용한 제주지역 수질원에 관한 연구)

  • 안종성;한정상
    • Water for future
    • /
    • v.17 no.2
    • /
    • pp.72-79
    • /
    • 1984
  • This investagation was carried out by analyzing water types and measuring the environmetal isotopes (tritium and deuterium) for development of water resources and protection of ground waters from sea water intrusion. The water sample were taken monthly from April to June, 1983 from sixteen sites in the Cheju metropolitan area; three sea, three spring, and ten ground waters. The ground water in the midwest area of the city contained 20 TU of tritium and-46 per mille of deuterium, classified as the $NaHCO_3$ type of ground water, generally deep seated. The spring water and ground water in the southern part of the city contained 15 to of tritium and-39 per mile of deuterium, and appeared to the $CaHCO_3$ type of shallow ground water, easily affected 표 precipitation. The results of tritium and deuterium analyses showed that the ground water in the coastal area were not affected by sea water intrusion, although they changed from $NaHCO_3$ or $CaHCO_3$ type to NaCl type in May and June. It is concluded that the high Na and Cl content in those ground waters might come from municipal sewage. The sea water in the Yong-duam area was influenced by sping water.

  • PDF

A Ground Detection Technique based on Region Segmentation in Spherical Image (영역 분할에 기반한 구면 영상에서의 바닥 검출 기법)

  • Kim, Jong-Yoon;Park, Jong-Seung
    • Journal of Korea Game Society
    • /
    • v.17 no.6
    • /
    • pp.139-152
    • /
    • 2017
  • In this paper, we propose a ground area detection technique based on region segmentation in the spherical image. We modified the Watershed planar image segmentation method to segment spherical images. After regions are segmented, the ground area is detected by comparing colors and textures of pixels of the assumed ground region with the pixels of other regions. The ground detection technique for planar images cannot be used for spherical images due to the spherical distortion. Considering the spherical distortion, we designed the ground shape detection algorithm to detect the ground area in the spherical images. Our experimental results show that the proposed technique properly detects ground areas both for the flat ground and the obstacle-filled ground environments.

Application of Automated Measuring System for the Underground Construction in Urban Area (도심지 근접시공의 자동계측응용)

  • 남순성;정상용
    • Explosives and Blasting
    • /
    • v.15 no.2
    • /
    • pp.53-72
    • /
    • 1997
  • It is impossible to precat the behavior of ground soil and structure accurately during underground construction in urban area or excavation in soft ground area because of difference between the assumed design condition and the actual site condition. Therefore, it must be managed by measuring system and correct the difference by real data. Large scale under ground construction in urban area like a seoul subway project has needed for Intelligent Construction technique, a field of the Engineering Contractor. The automated measuring system is developed for the technique. It is described that the procedure and the method of measuring work with application of the automated measuring system.

  • PDF

Reasonable Design Method of Vertical Drain Depending on the Depth of Soft Ground (연약지반의 심도에 따른 연직 배수재의 합리적 설계 방안)

  • Lim, Chang-Su;Lee, Dal-Won
    • Korean Journal of Agricultural Science
    • /
    • v.28 no.2
    • /
    • pp.108-115
    • /
    • 2001
  • In this study, to propose the reasonable evaluation method of degree of consolidation considering the depth of soft ground, the two soft ground areas were chosen and analyzed for the consolidation degree. One was a western coast area in which depth of soft ground was low, and the other was a southern coast area in which depth of soft ground was deep. At the area in which depth of soft ground was low, Barron's and Yoshikuni's methods showed that the evaluation of consolidation degree was large, and it is reasonable that $C_h=C_v$ be recommended to apply the Hansbo's and the Onoue's methods. At the area in which depth of soft ground was deep, it is reasonable that $C_h=C_v$ be recommended to apply the Barron's and the Yoshikuni's methods, and $C_h=(2{\sim}3)C_v$ to apply the Hansbo's and the Onoue's methods. According to the Hansbo's and Onoue's methods, degree of consolidation proved to be applicable with measured data when using the $k_s=(1/3)k_v$ at the area which depth of soft ground was low and using the $k_s=(1{\sim}1/2)k_v$ at the area which depth of soft ground was deep. According to the Hansbo's and Onoue's methods, degree of consolidation was proved to be applicable with measured data when using ds=(3~5)dm at the area which depth of soft ground was low and using ds=2dm at the area which depth of soft ground was deep.

  • PDF

A Study on High Graded Limestone Population Area (석회석 원소재의 고품위대 조사를 위한 연구)

  • Kim, Jun-Kyoung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.343-348
    • /
    • 2007
  • Geophysical methodology using GPR(Ground Penetrating Radar) were applied both to the limestone producing area(Sambo Mine Company & Haksanri Area) and to Landfill area(Mureung Landfill Site). The investigation results resultant from both the limestone producing area(Sambo Mine Company & Haksanri Area) showed that there are a few events reflected from boundaries between caves and basement rocks. Those from landfill area showed that more complicated and small size events are found. These events could be from different electric characteristics of various kinds of composition materials in the landfill site.

  • PDF

Study on Stress Sharing Mechanism Composition Ground Improved by SCP with Low Replacement Area Ratio (저치환율 SCP에 의한 복합지반의 응력분담 메커니즘에 관한 연구)

  • You, Seung-Kyong;Matsui, Tamotsu;Hong, Won-Pyo;Yoon, Gil-Lim
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.197-202
    • /
    • 2004
  • In order to design accurately sand compaction pile (SCP) method with low replacement area ratio, it is important to understand the mechanical interaction between sand piles and clays and its mechanism during consolidation process of the composition ground. In this paper, a series of numerical analyses on composition ground improved by SCP with low replacement area ratio were carried out, in order to investigate the mechanical interaction between sand piles and clays. The applicability of numerical analyses, in which an elasto-viscoplastic consolidation finite element method was applied, could be confirmed comparing with results of a series of model tests on consolidation behaviors of composition ground improved by SCP. And, through the results of the numerical analyses, each mechanical behaviors of sand piles and clays in the composition ground during consolidation was elucidated, together with stress sharing mechanism between sand piles and clays.

  • PDF

Comparison Study on Stress Sharing Characteristics of Sand or Gravel Compaction Piles with Low Replacement Area Ratio (모래와 쇄석을 이용한 저치환율 다짐말뚝공법의 응력분담특성에 관한 비교)

  • You, Seung-Kyong;Cho, Sung-Min;Kim, Ji-Yong;Shim, Min-Bo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.443-452
    • /
    • 2005
  • The compaction pile methods with low replacement area ratio used sand(SCP) or gravel(GCP) has been usually applied to improvement of soft clay deposits. In order to design accurately compaction pile method with low replacement area ratio, it is important to understand the mechanical interaction between sand piles and clays and its mechanism during consolidation process of the composition ground. In this paper, a series of numerical analyses on composition ground improved by SCP and GCP with low replacement area ratio were carried out, in order to investigate the mechanical interaction between sand piles and clays. The applicability of numerical analyses, in which and elasto-viscoplastic consolidation finite element method was applied, could be confirmed comparing with results of a series of model tests on consolidation behaviors of composition ground improved by SCP. And,through the results of the numerical analyses, each mechanical behaviors of compaction piles and clays in the composition ground during consolidation was elucidated, together with stress sharing mechanism between compaction piles and clays.

  • PDF