• Title/Summary/Keyword: Grooves

Search Result 574, Processing Time 0.021 seconds

Effect of rotation bump on removal torque of orthodontic mini-implants

  • Gansukh, Odontuya;Jeong, Jong-Wha;Kim, Jong-Wan;Kim, Young-Kyun;Lee, Jong-Ho;Kim, Tae-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.6
    • /
    • pp.269-273
    • /
    • 2013
  • Objectives: This study is designed to evaluate the mechanical stability of orthodontic mini-implants with vertical grooves in rabbits. Materials and Methods: This study was done from March 2011 to February 2012 in Dental Research Institute of Seoul National University. Thirty-two mini-implants in the control group and 32 in the rotation bump (RB) group were inserted in the tibias of 16 rabbits and were removed after two weeks and four weeks, respectively. The maximum insertion torque (MIT), maximum removal torque (MRT), torque ratio (TR) of MRT to MIT and removal angular momentum (RAM) were all measured at the time of removal. Results: There were no significant differences between the two groups in MIT and MRT at two weeks or four weeks. However, TR and RAM at four weeks in the RB group were significantly higher than in the control group (P<0.05). TR of the RB group was significantly increased at four weeks (P<0.05). In both groups, RAM at four weeks was significantly higher than at two weeks (P<0.05). Conclusion: These results suggest that RB of the mini-implant could provide resistance to the removal rotation, although it did not increase the MRT.

Scanning Electron Microscopic Study of the Effects of Citric Acid on the Change of Implant Surface According to Application Time (구연산의 적용시간에 따른 임플란트 표면변화에 대한 주사전자현미경적 연구)

  • Song, Woo-Seok;Kwon, Young-Hyuk;Lee, Man-Sup;Park, Joon-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.4
    • /
    • pp.697-709
    • /
    • 2002
  • The present study was performed to evaluate the effect of citric acid on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, titanium plasma-sprayed surface, and sand-blasted, large grit, acid etched surface were utilized. Implant surface was rubbed with pH 1 citric acid for $\frac{1}{2}$ min., 1 min., 1 $\frac{1}{2}$ min., 2 min., and 3min, respeaively in the test group and implant surface was not treated in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In titanium plasma-sprayed surfaces, round or amorphous particles were deposited irregularly. The irregularity of titanium plasma-sprayed surfaces conditioned with pH 1 citric acid was lessened and the cracks were increased relative to the application time of pH 1 citric acid. 3. Sand-blasted, large grit, acid etched surfaces showed the macro/micro double roughness. The application of pH 1 citric acid didn't change the characteristics of the sand-blasted, large grit, acid etched surfaces. In conclusion, the application of pH 1 citric acid to titanium plasma-sprayed surface is improper. And pure titanium machined surface implants and sand-blasted, large grit, acid etched surface implants can he treated with pH 1 citric acid for peri-implantitis treatment if the detoxification of these surfaces could be evaluated.

The Micromorphometric change of the GBA and RBM implant surface conditioned with tetracycline-HCI (염산테트라싸이클린 적용시간에 따른 GBA 및 RBM 임프란트 표면변화)

  • Park, Kang-Hun;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.705-716
    • /
    • 2006
  • The present study was performed to evaluate the effect of tetracycline-HCl on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface, GBA surface and RBM surface were utilized. Implant surface was rubbed with 50mg/ml tetracycline-HCl solution for ${\frac{1}{2}}$min. 1min. $1{\frac{1}{2}}$min. 2min. and $2{\frac{1}{2}}$min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation. The results of this study were as follow. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two group. 2. In GBA surfaces, control group exhibit many porous depression, and each depression were divided by strict border. Experimental group applied with tetracycline-HCl for 2min. were similar with control group. But when applied for $2{\frac{1}{2}}$min. surface alteration and border breakdown started, resulting enlargement of the porous depression. 3. In REM surface, control group exhibit rough, uneven surface with crater-like depression can be found. The surface alteration started when tetracycline-HCl was applied for 30sec. resulting breakdown of the crater-like depression. Depression became larger as applying time increased.

Micromorphometric change of implant surface conditioned with tetracycline-HCI : $FBR^{(R)}$ and CeliNest surface (표면처리 시간에 따른 임프란트 미세구조의 변화 : $FBR^{(R)}$과 CellNest 표면 임프란트)

  • Chang, Dong-Wook;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.717-729
    • /
    • 2006
  • The present study was performed to evaluate the effect of tetracycline-BCL on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface, double coated $FBR^{(R)}$ surface and oxidized CellNest surface were utilized. Implant surface was rubbed with $50mg/m{\ell}$ tetracycline-BCL solution for ${\frac{1}{2}}$, 1, $1{\frac{1}{2}}$, 2 and $2{\frac{1}{2}}$min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation. The results of this study were as follows. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. The double coated $FBR^{(R)}$ surfaces showed fine crystalline structures. The roughness of surfaces conditioned with tetracycline-BCL was lessened relative to the application time. 3. The oxidized CellNest surfaces showed the porous structures. The surface conditioning with tetracycline-BCI influenced on its micro-morphology. In conclusion, the detoxification of the affected implant surface with $50mg/m{\ell}$ tetracycline-BCL should be applied respectively with different time according to various implant surfaces.

Micromorphometric change of implant surface conditioned with Tetracycline-HCl : HA and Etched surface (염산테트라싸이클린의 적용시간에 따른 특수 가공된 임프란트 표면 변화)

  • Han, Ju-Young;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.731-744
    • /
    • 2006
  • The present study was performed to evaluate the effect of tetracycline-HCl on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface, HA-coated surface and dual acid etched surface were utilized. Implant surface was rubbed with $50mg/m{\ell}$ tetracycline-HCL solution for ${\frac{1}{2}}$min., 1min., $1{\frac{1}{2}}$min., 2min., and $2{\frac{1}{2}}$min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation. The results of this study were as follows. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In HA-coated surfaces, round particles were deposited irregularly. The roughness of surfaces conditioned with tetracycline-HCL was lessened and the cracks were increased relative to the application time. 3. The etched surfaces showed the honey comb structures. The surface conditioning with tetracycline-HCI didn't influence on its micro-morphology. In conclusion, the detoxification with $50mg/m{\ell}$ tetracycline-HCI must be applied respectively with different time according to various implant surfaces.

Development of medium resolution cross-dispersed silicon grisms in the Near Infrared ; Direct Silicon wafer bonding technique

  • Jeong, Hyeon-Ju;Wang, Wei-Song;Gully-Santiago, Michael;Deen, Casey;Pak, Soo-Jong;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.125.2-125.2
    • /
    • 2011
  • We are developing medium resolution cross-dispersed silicon grisms in the near IR region ($1.45{\sim}5.2{\mu}m$). The grisms will be installed in MIMIR, a multifunction instrument at the Lowel Observatory, USA. The two devices are designed to cover H and K band and L and M band simultaneously. Our goal is to make grism with R=3000 at 1.2 arcsec slit. The Silicon has high refractive index (n=3.4 at $1.5{\mu}m$) which enhances the resolving power by up to 5 times when compared to conventional material such as BK-7 (n=1.5 at 1.5 ${\mu}m$). The bonded grisms will be installed in a filter wheel for the uses switch from spectroscopic mode to imaging mode easily. Our device is compact and light weighted while it provides a decent resolving power. We produce monolithic grisms using e-beam lithography at the NASA JPL and chemically etching the grooves on the silicon prisms. Moreover, the main-disperser and cross-disperser will be contacted together by direct Si-Si bonding technique and eventually turn into one piece. The bonded pair offers more stability in terms of the layout of the spectrum and removes the Fresnel loss at the intersection of two grisms. We report on the proper wafer bonding steps through this research, and inspected the bonding quality thermally, optically and mechanically.

  • PDF

Modified Microstrip Filters Improving the Suppression Performance of Harmonic Signals (고조파 감쇠특성을 향상시킨 변형된 마이크로스트립 여파기)

  • 김봉수;이재욱;송명선
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.1054-1060
    • /
    • 2002
  • In this paper, a new parallel-coupled-line microstrip BPF(BandPass Filter) improving the suppression performance of 2nd harmonic signals is studied. Using the consecutive pattern in coupled-line, the desired passband performance is improved and harmonic passband signal is rejected. Recalculation of classical filter design parameters(space-gap between lines, line widths and lengths) is not required. That is, after using the classical design methodology for parellel-coupled-line BPF, new filters can be easily realized by inserting periodic patterns in coupled-line. To investigate the validity of this novel technique, order-3 Butterworth BPF centered at 2.5 GHz with a 10 % FBW(Fractional Bandwidth) and order-5 Chebyshev BPF centered at 10 GHz with a 15 % FBW were used. When five and three square grooves are used, over 30 dB harmonic suppression at 2nd harmonic is achieved in simulation and experiment.

Pollen morphology of the genus Aruncus L. (Rosaceae) (개승마속(Aruncus L., 장미과)의 화분형태학적 연구)

  • Ok, Min-Kyoung;Hong, Suk-Pyo
    • Korean Journal of Plant Taxonomy
    • /
    • v.45 no.4
    • /
    • pp.323-331
    • /
    • 2015
  • Pollen morphological characteristics of 7 taxa of the genus Aruncus L. (Rosaceae) were examined using scanning electron microscopy (SEM) to evaluate the taxonomic implication within the genus. Aruncus pollen grains were monad, tri-colporate with granular membranes, small in size ($P=8.33-12.57{\mu}m$, $E=8.93-14.40{\mu}m$), amb is sub-circular to circular, suboblate to prolate-spheroidal in shape (P/E = 0.68-1.70). The sexine ornamentation in all studied taxa was basically striate but existence of perforation (striate-perforate: A. dioicus, A. dioicus var. acuminatus, A. dioicus var. astilboides, A. dioicus var. pubescens, A. dioicus var. vulgaris; striate-pstilate: A. dioicus var. aethusifolius, A. gombalanus) and the widths of muri and grooves varied according to the taxa. In particular, relatively short, and sharply crested muri being a distinct feature of A. dioicus var. acuminatus. As a result, the various combination of each pollen characteristics could be useful to identify the some taxa of the genus Aruncus.

Dry Etching Using Atmospheric Plasma for Crystalline Silicon Solar Cells (대기압 플라즈마를 이용한 결정질 태양전지 표면 식각 공정)

  • Hwang, Sang Hyuk;Kwon, Hee Tae;Kim, Woo Jae;Choi, Jin Woo;Shin, Gi-Won;Yang, Chang-Sil;Kwon, Gi-Chung
    • Korean Journal of Materials Research
    • /
    • v.27 no.4
    • /
    • pp.211-215
    • /
    • 2017
  • Reactive Ion Etching (RIE) and wet etching are employed in existing texturing processes to fabricate solar cells. Laser etching is used for particular purposes such as selective etching for grooves. However, such processes require a higher level of cost and longer processing time and those factors affect the unit cost of each process of fabricating solar cells. As a way to reduce the unit cost of this process of making solar cells, an atmospheric plasma source will be employed in this study for the texturing of crystalline silicon wafers. In this study, we produced the atmospheric plasma source and examined its basic properties. Then, using the prepared atmospheric plasma source, we performed the texturing process of crystalline silicon wafers. The results obtained from texturing processes employing the atmospheric plasma source and employing RIE were examined and compared with each other. The average reflectance of the specimens obtained from the atmospheric plasma texturing process was 7.88 %, while that of specimens obtained from the texturing process employing RIE was 8.04 %. Surface morphologies of textured wafers were examined and measured through Scanning Electron Microscopy (SEM) and similar shapes of reactive ion etched wafers were found. The Power Conversion Efficiencies (PCE) of the solar cells manufactured through each process were 16.97 % (atmospheric plasma texturing) and 16.29 % (RIE texturing).

Monitoring the Differentiation and Migration Patterns of Neural Cells Derived from Human Embryonic Stem Cells Using a Microfluidic Culture System

  • Lee, Nayeon;Park, Jae Woo;Kim, Hyung Joon;Yeon, Ju Hun;Kwon, Jihye;Ko, Jung Jae;Oh, Seung-Hun;Kim, Hyun Sook;Kim, Aeri;Han, Baek Soo;Lee, Sang Chul;Jeon, Noo Li;Song, Jihwan
    • Molecules and Cells
    • /
    • v.37 no.6
    • /
    • pp.497-502
    • /
    • 2014
  • Microfluidics can provide unique experimental tools to visualize the development of neural structures within a microscale device, which is followed by guidance of neurite growth in the axonal isolation compartment. We utilized microfluidics technology to monitor the differentiation and migration of neural cells derived from human embryonic stem cells (hESCs). We co-cultured hESCs with PA6 stromal cells, and isolated neural rosette-like structures, which subsequently formed neurospheres in suspension culture. Tuj1-positive neural cells, but not nestin-positive neural precursor cells (NPCs), were able to enter the microfluidics grooves (microchannels), suggesting that neural cell-migratory capacity was dependent upon neuronal differentiation stage. We also showed that bundles of axons formed and extended into the microchannels. Taken together, these results demonstrated that microfluidics technology can provide useful tools to study neurite outgrowth and axon guidance of neural cells, which are derived from human embryonic stem cells.