• Title/Summary/Keyword: Grooves

Search Result 574, Processing Time 0.021 seconds

Characteristics of Micro Groove grinding for the Mold of PDP Barrier Ribs (PDP 격벽용 금형의 마이크로 홈 연삭 특성)

  • 조인호;정상철;박준민;정해도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.963-966
    • /
    • 2000
  • Plasma display panel (PDP) is a type of flat panel display utilizing the light emission that is produced by gas discharge. Barrier Ribs of PDP separating each sub-pixel prevents optical and electrical crosstalk from adjacent sub-pixels. Mold for forming barrier ribs has been newly researched to overcome the disadvantages of conventional manufacturing process such as screen printing, sand-blasting and photosensitive glass methods. Mold for PDP barrier ribs have stripes of micro grooves transferring stripes of glass-material wall. In this paper. Stripes of grooves of which width 48 um, depth 124um, pitch 274um was acquired by machining the material of WC with dicing saw blade. Maximum roughness of the bottom and sidewall of the grooves was respectively 120 nm, 287 nm. Maximum tilt angle caused by difference between upper-most width and lower-most width was 2$^{\circ}$. Maximum Radius of curvature of bottom was 7.75 ${\mu}{\textrm}{m}$. This results meets the specification for barrier ribs of 50 inch XGA PDP. Forming the glass paste will be followed by using mold in the near future.

  • PDF

A Modified SDB Technology and Its Application to High-Power Semiconductor Devices (새로운 SDB 기술과 대용량 반도체소자에의 응용)

  • Kim, E.D.;Park, J.M.;Kim, S.C.;Min, M.G.;Lee, Y.S.;Song, J.K.;Kostina, A. L.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.348-351
    • /
    • 1995
  • A modified silicon direct bonding method has been developed alloying an intimate contact between grooved and smooth mirror-polished oxide-free silicon wafers. A regular set of grooves was formed during preparation of heavily doped $p^+$-type grid network by oxide-masking und boron diffusion. Void-free bonded interfaces with filing of the grooves were observed by x-ray diffraction topography, infrared, optical. and scanning electron microscope techniques. The presence of regularly formed grooves in bending plane results in the substantial decrease of dislocation over large areas near the interface. Moreover two strongly misoriented waters could be successfully bonded by new technique. Diodes with bonded a pn-junction yielded a value of the ideality factor n about 1.5 and the uniform distribution of series resistance over the whole area of horded pn-structure. The suitability of the modified technique was confirmed by I - V characteristics of power diodes and reversly switched-on dynistor(RSD) with a working area about $12cm^2$. Both devices demonstrated breakdown voltages close to the calculation values.

  • PDF

An Experimental Study on the Thermal Performance of a Flat-Ship Heat Pipe with Inner Grooves and Screen Mesh Cover (내부에 그루브와 스크린 메쉬를 갖는 평판 스트립형 히트파이프의 열성능에 대한 실험적 연구)

  • Park Soo Yong;Boo Joon Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.805-813
    • /
    • 2005
  • The thermal performance of a flat-strip heat pipe with inner grooves and the screen mesh cover was investigated experimentally. The heat pipes were made of 2024 aluminum alloy of which the dimensions were 30 (W) $\times$ 4 (T) $\times$ 150 (L) mm. The cross sectional dimensions of inner groove were 0.4$\times$0.9 mm and the space between grooves was 0.6 mm. To enhance the capillary force, foe screen meshes were attached to cover the grooved inner surface. In the grooved heat pipes without screen mesh cover, the maximum thermal load of 180 W (12 W/$cm^2$) was achieved for operating temperature below $130^{\circ}C$ at horizontal position. The heat pipes with screen mesh cover showed the thermal resistances less than one third of those without screen mesh cover, and showed less fluctuation in the thermal resistance values. Furthermore, the thermal performance of the former exhibited less dependence on the tilt angle and the fill charge ratio.

A Study on the Improement of Condensation and Boiling Heat Transfer on Horizontal Tube by Fin Effect(ll)-Shellside Condensation- (수평 원형전열관의 핀효과에 의한 응축 및 비등 열전달촉진에 관한 연구 (2)-튜브외부 응축-)

  • 한규일;조동현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1275-1287
    • /
    • 1994
  • Heat transfer performance improvement by fin and grooves is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapezoidal shaped integral-fins having fin densities from 748 to 1654 fpm and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also tested for comparison. R-11 condenses at saturation state of $32^{\circ}C$ on the outside tube surface cooled by inside water flow. All of test data ate taken at steady state. Beatty and Katz's, Rudy's and Webb's theoretical models are used to predict the R-11 condensation coefficient of tubes having 748, 1024 and 1299 fpm. The predicted value by Betty and Katz's model is within 10% of experimental values in this study at fpm<1024 and Rudy's model predicted the experimental data at fpm>1024 within 15%. The tube having fin density of 1299 fpm and 30 grooves has the best overall heat transfer performance. This tube shows the overall heat transfer coefficient of 11500 $W/m^{2}K$,/TEX> at coolant velocity of 3.0m/s.

Effect of the Semi-circular Relieving Groove on the Stress Concentration at the Fillet of the Stepped Bar under Axial Tension (축인장하(軸引張下)의 평판(平板)의 단부(段部) Fillet 근처(近處)의 Relieving Groove가 응력집중(應力集中)에 미치는 영향(影響))

  • Hyo-Chul,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.6 no.2
    • /
    • pp.5-10
    • /
    • 1969
  • A stepped bar with seimi-circular stress relieving groove near the fillet was subjected by axial tension in a polarized light field. On the stress concentration factor, the effect of the ratios of the fillet radius, the distance between two relieving grooves and the groove radius to the breath of the narrower portion of the stepped bar have been investigate. Observing the stress concentration in 48 models with various proportions, the conclusion arrived at were as follow: 1) If the fillet radius of the stepped bar is larger than half breadth of the narrower portion, the reduction of the stress concentrations can not be expected. 2) If the fillet radius is smaller than half breadth of the narrower portion of the stepped bar, the stress concentration can be droped to the reasonable range. 3) When the groove radius is larger than a quarter of the difference between the distance of two relieving grooves and the breadth of the stepped bar and smaller than a half of that, the stress concentration factors can have their possible minimum value. 4) When the sun of the breadth of the narrower portion of the stepped bar and twice of the relieving groove radius is smaller than the distance between two relieving grooves, minimum stress concentration can be obtained.

  • PDF

Definitions of groove and hollowness of the infraorbital region and clinical treatment using soft-tissue filler

  • Lee, Ji-Hyun;Hong, Giwoong
    • Archives of Plastic Surgery
    • /
    • v.45 no.3
    • /
    • pp.214-221
    • /
    • 2018
  • Clarification is needed regarding the definitions and classification of groove and hollowness of the infraorbital region depending on the cause, anatomical characteristics, and appearance. Grooves in the infraorbital region can be classified as nasojugal grooves (or folds), tear trough deformities, and palpebromalar grooves; these can be differentiated based on anatomical characteristics. They are caused by the herniation of intraorbital fat, atrophy of the skin and subcutaneous fat, contraction of the orbital part of the orbicularis oculi muscle or squinting, and malar bone resorption. Safe and successful treatment requires an optimal choice of filler and treatment method. The choice between a cannula and needle depends on various factors; a needle is better for injections into a subdermal area in a relatively safe plane, while a cannula is recommended for avoiding vascular compromise when injecting filler into a deep fat layer and releasing fibrotic ligamentous structures. The injection of a soft-tissue filler into the subcutaneous fat tissue is recommended for treating mild indentations around the orbital rim and nasojugal region. Reducing the tethering effect of ligamentous structures by undermining using a cannula prior to the filler injection is recommended for treating relatively deep and fine indentations. The treatment of mild prolapse of the intraorbital septal fat or broad flattening of the infraorbital region can be improved by restoring the volume deficiency using a relatively firm filler.

Experimental study on effect of EBRIG shear strengthening method on the behavior of RC beams

  • Shomali, Amir;Mostofinejad, Davood;Esfahani, Mohammad Reza
    • Advances in concrete construction
    • /
    • v.8 no.2
    • /
    • pp.145-154
    • /
    • 2019
  • The present experimental study addresses the structural response of reinforced concrete (RC) beams strengthened in shear. Thirteen RC beams were divided into four different sets to investigate the effect of transverse and longitudinal steel reinforcement ratios, concrete compressive strength change and orientation for installing carbon fiber-reinforced polymer (CFRP) laminates. Then, we employed a shear strengthening solution through externally bonded reinforcement in grooves (EBRIG) and externally bonded reinforcement (EBR) techniques. In this regard, rectangular beams of $200{\times}300{\times}2000mm$ dimensions were subjected to the 4-point static loading condition and their load-displacement curves, load-carrying capacity and ductility changes were compared. The results revealed that using EBRIG method, the gain percentage augmented with the increase in the longitudinal reinforcement ratio. Also, in the RC beams with stirrups, the gain in shear strength decreased as transverse reinforcement ratio increased. The results also revealed that the shear resistance obtained by the experimental tests were in acceptable agreement with the design equations. Besides, the results of this research indicated that using the EBRIG system through vertical grooves in RC beams with and without stirrups caused the energy absorption to increase about 85% and 97%, respectively, relative to the control.

Development of the Structure for Enhancing Capillary Force of the Thin Flat Heat Pipe Based on Extrusion Fabrication (압출형 박판 히트파이프의 모세관력 향상을 위한 구조 개발)

  • Moon, Seok Hwan;Park, Yoon Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.11
    • /
    • pp.755-759
    • /
    • 2016
  • The use of heat pipes in the electronic telecommunication field is increasing. Among the various types of heat pipes, the thin flat heat pipe has relatively high applicability compared with the circular heat pipe in the electronic packaging application. The thin flat heat pipe based on extrusion fabrication has a simple capillary wick structure consisting of rectangular cross sectional grooves on the inner wall of the pipe. Although the groove serves as a simple capillary wick, and many such grooves are provided on the inner wall, it is difficult for the grooves to realize a sufficiently high capillary force. In the present study, a thin flat heat pipe with a wire bundle was developed to overcome the drawback of poor capillary force in the thin flat heat pipe with grooves, and was evaluated by conducting tests. In the performance test, the thin flat heat pipe with the wire bundle showed a lower thermal resistance of approximately 3.4 times, and a higher heat transfer rate of approximately 3.8 times with respect to the thin flat heat pipe with grooves as the capillary wick respectively. The possibility of using the wire bundle as a capillary wick in the heat pipe was validated in the present study; further study for commercializing this concept will be taken up in the future.

A Study on the Detergency of Alkali-treated Polyester Fabric - The effects of surface structure- (알칼리 감양가공이 Polyester 직물의 세척성에 미치는 영향 -표면구조의 효과를 중심으로-)

  • Shin Rae Won;Kim Sung Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.10 no.2
    • /
    • pp.1-9
    • /
    • 1986
  • To study the effects of surface structure of fiber on the decrement of fatty soil removal at high temperature, the following variables were selected: controled and alkali-treated P.E.T.(polyester) fabrics and chopped fibers as substrates to estimate the detergencies, different aging methods of soiled substrates, and different washing temperatures and surfactant solutions. Radiotagged tripalmitin was used as soil and the detergency was estimated by means of liquid scintillation counting method. The results were as following: The surface of the fiber became rough with many grooves and the hydrophilicity of the fiber was increased and the structure of the fabric became loose by alkali treatment. While the detergency of alkali-treated P.E.T. fabric was better than that of controled P. E. T. fabric, there was no significant differences between the detergencies of controled and alkali-treated chopped fibers. These results indicate that the increment of detergency of alkali-treated P.E.T. fabric is mainly resulted from the changes of fabric structure and the improved hydrophilicity of fiber by alkai treatment. The detergency of tripalmitin was increased with elevating temp. below the m.p. of tripalmitin, was decreased around the m.p., and again was increased above the m.p ..It is considered that the decrement of detergency around the m.p. is due to the diffusion of molten tripalmitin into the grooves on fiber surface, the inner part of fiber, and between fibers. When controled and alkali-treated soiled fabrics and soiled chopped fibers were washed in the distilled water and in the Na-DBS solution respectively, below $60^{\circ}C$ detergencies of alkali-treated fabrics and chopped fibers were improved. However above $60^{\circ}C$ this result was reversed. Therefore these results are regarded as the effects of grooves on fiber surface at high temp. and improved hydrophilicity at low temp. by alkali treatment. When controled and alkali-treated soiled fabrics and soiled chopped fibers were hot-aged before washing, the detergencies of both species were decreased generally. Because the soil was diffused into the grooves on fiber surface, the inner part of fiber, and between fibers during hot-aging. The detergencies of hot-aged species were also decreased above certain temp.. These results suggest that the decrement of detergency at high temp. be resulted not only from the diffusion of soil into the grooves on fiber surface, the inner part of fiber, and between fibers, but also from the characteristics of surfactant solutions.

  • PDF

A Study on the Performance of Boiling Beat Transfer of Inclined Thermosyphon Heat Exchangers with Internal Grooves (경사 열사이폰 열교환기의 비등열전달 성능에 관한 연구)

  • Cho, Dong-Hyun;Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.2
    • /
    • pp.202-209
    • /
    • 2005
  • This study concerns the performance of boiling heat transfer in inclined thermosyphons with internal grooves. A study was carried out with the performance of the heat transfer of the inclined thermosyphon having 60 internal grooves in which boiling and condensation occur. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphon is also tested for comparison. Distilled water, methanol and ethanol have been used as the working fluid. The inclination angle, three working fluids, heat flux and the boiling heat transfer coefficient at the evaporator zone are estimated from the experimental results. The experimental results have been assessed and compared with existing correlations. Imura's and Kusuda's correlation for boiling showed in good agreement with experimental results within ${\pm}20%$ in plain thermosyphon. The high heat transfer coefficient was found between $25^{\circ}$ and $30^{\circ}$ of inclination angle for water and between $20^{\circ}$ and $25^{\circ}$ for methanol and ethanol. The relatively high rates of heat transfer have been achieved in the thermosyphon with internal micro grooves.

  • PDF