DOI QR코드

DOI QR Code

An Experimental Study on the Thermal Performance of a Flat-Ship Heat Pipe with Inner Grooves and Screen Mesh Cover

내부에 그루브와 스크린 메쉬를 갖는 평판 스트립형 히트파이프의 열성능에 대한 실험적 연구

  • 박수용 (한국항공대학교 대학원 항공공학과) ;
  • 부준홍 (한국항공대학교 항공우주 및 기계공학부)
  • Published : 2005.07.01

Abstract

The thermal performance of a flat-strip heat pipe with inner grooves and the screen mesh cover was investigated experimentally. The heat pipes were made of 2024 aluminum alloy of which the dimensions were 30 (W) $\times$ 4 (T) $\times$ 150 (L) mm. The cross sectional dimensions of inner groove were 0.4$\times$0.9 mm and the space between grooves was 0.6 mm. To enhance the capillary force, foe screen meshes were attached to cover the grooved inner surface. In the grooved heat pipes without screen mesh cover, the maximum thermal load of 180 W (12 W/$cm^2$) was achieved for operating temperature below $130^{\circ}C$ at horizontal position. The heat pipes with screen mesh cover showed the thermal resistances less than one third of those without screen mesh cover, and showed less fluctuation in the thermal resistance values. Furthermore, the thermal performance of the former exhibited less dependence on the tilt angle and the fill charge ratio.

Keywords

References

  1. Faghri, A., 1995, Heat Pipe Science and Technology, Taylor & Francis, pp. 625-631
  2. Cotter, T.P., 1984, 'Principles and Prospects for Micro Heat Pipes,' Proceedings of The 5th International Heat Pipe Conference, pp. 126-133
  3. Babin, B.R., Peterson, G.P. and Wu, D., 1990, 'Steady-State Modeling and Testing of a Micro Heat Pipe,' ASME Journal of Heat Transfer, Vol. 112, No. 3, pp. 595-601 https://doi.org/10.1115/1.2910428
  4. Mallik, A.K., Peterson, G.P. and Weichold, M.H., 1995, 'Fabrication of Vapor-Deposited Micro Heat Pipe Arrays as an Integral Part of Semiconductor Devices,' Journal of MicroElectro-Mechanical System, Vol. 4, No. 3, pp. 119-131 https://doi.org/10.1109/84.465123
  5. Cao, Y., Gao, M., Beam, J.E. and Donovan, B., 1996, 'Experiments and Analyses of Flat Miniature Heat Pipes,' Proceedings of The 31th Intersociety Energy Conversion Engineering Conference, Vol. 2, pp. 1402-1409 https://doi.org/10.1109/IECEC.1996.553927
  6. Khrustalev, D. and Faghri, A., 1996, 'Enhanced Flat Miniature Axially Grooved Heat Pipe,' ASME Journal of Heat Transfer, Vol. 118, No. 1, pp. 261-264 https://doi.org/10.1115/1.2824057
  7. Lee, Y.S., Lee, Y.P. and Lee, Y., 1992, 'An Experimental Study on Micro Two-Phase Closed Thermosyphons with Inserts,' Proceedings of The 8th IHPC, C-P1
  8. Moon, S.H., Hwang, G. and Choy, T.G., 2001, 'Application of Miniature Heat Pipe for Notebook PC Cooling,' Transactions of the KSME (B), Vol. 25, No. 6, pp. 799-803
  9. Kim, K.S., Moon, S.H. and Choi, C.G., 1999, 'Cooling Characteristics of Miniature Heat Pipes with Woven-Wired Wick,' Proceedings of The 11th International Heat Pipe Conference, pp. 20-25
  10. Peterson, G. P., 1994, An Introduction to Heat Pipes, Wiley Interscience Publication, pp. 4-7

Cited by

  1. Development of the Structure for Enhancing Capillary Force of the Thin Flat Heat Pipe Based on Extrusion Fabrication vol.40, pp.11, 2016, https://doi.org/10.3795/KSME-B.2016.40.11.755