• Title/Summary/Keyword: Grit chamber

Search Result 18, Processing Time 0.023 seconds

Impact of Grit Chamber Deposits on Water Quality at the Mouth of Yeocheoncheon, Ulsan (여천천 하구에 설치된 침사지내 퇴적토의 수질영향분석)

  • Lee, Sang-Hyeon;Cho, Hong-Je
    • Journal of Environmental Science International
    • /
    • v.25 no.8
    • /
    • pp.1191-1206
    • /
    • 2016
  • Transported deposit was accumulated in a grit chamber built at the mouth of Yeocheoncheon in 1987 with the intention of blocking the influx of sediment into the Ulsan-harbor. This study attempted to analyze the effects of the transported deposit on the water quality at Yeocheoncheon. Only one episode of dredging has been performed in the approximately 25 years since the grit chamber were built, leading to the formation of stagnant water in the grit chamber due to a large amount of transported deposit. The deposit has a relatively high organic content, in the range of 11.7-25.9% (mean 18.3%). It appears that the main reason for the upstream transport of water pollution from the mouth of the Yeocheoncheon is the tides. The effects of organic content and stagnant water on water quality were analyzed using WASP. Moreover, the changes in water quality arising due to the removal of the grit chamber were analyzed. Results indicated that BOD improved by 18.8-100%, while T-P improved by 90.0-617.4%, between the grit chamber and Hanbi-Gyo, which is located 1.3 km away from the grit chamber.

Study on flow characteristics of the grit chamber using VOF multi-phase flow simulations (VOF 다상유동 해석을 이용한 침사지 유동특성 연구)

  • Yoon, Jong-Hwan
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.2
    • /
    • pp.63-73
    • /
    • 2021
  • It is essential to accurately predict the change in water level, velocity, and flow rate for each passage of the grit chamber according to the operating conditions of the pump. In this study, VOF multiphase flow analysis was performed, and the flow characteristics of the grit chamber were predicted. As a result of simulations, the sedimentation phenomenon after the entrance of the grit chamber channel is expected to occur on the side walls. When 6 channels are used, the average speed of the channels is about 52% of the design standard, and when 4 channels are used, the value increases to 74% of the design standard. The average water level in the channels tends to decrease as the flow velocity increases, and the water level in the absorption well with a larger flow rate is maintained lower than that in the absorption well with a smaller flow rate.

Feasibility Analysis on the Application of Eco-friendly Prefabricated Rainwater Detention System in Grit Chamber and Permanent Pond by the Two-dimensional Diffusion-wave Analysis Model (2차원 확산파 해석모형을 통한 침사지겸 저류지의 친환경 조립식 빗물침투저류시설 적용 타당성 분석)

  • Kim, Ho-jin;Choi, Hee-Yong;Lee, Tae-Gyu;Choi, Hyeonggil
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.185-186
    • /
    • 2022
  • In this study, a numerical analysis was conducted using a two-dimensional diffusion-wave analysis model to analyze the validity about the application of eco-friendly prefabricated rainwater detention system in grit chamber and permanent pond. As a result of the analysis, it is confirmed that the flood prevention effect, such as a decrease in peak flow rate and a delay in peak time, is excellent, so it is considered reasonable to apply eco-friendly prefabricated rainwater detention system in grit chamber and permanent pond.

  • PDF

A Study on the Removal of Grease and Oill in the Treatment Plant (하수처리장의 유지제거에 대한 연구)

  • 박재효
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 1981
  • During 20 days from November 4 to 28, 1980, the quantities of grease and oil, BOD (biological oxygen demand), COD (chemical oxygen demand), SS (suspended solid) were measured at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank in Chung Gye Chun sewage treatment plant. The results were as follows. 1. The average of grease and oil quantities were 251mg/l at Grit Chamber, 185mg/l at Primary Sedimentation Tank, 47mg/l at Secondary Sedimentation Tank. 2. In the secondary treatment for the removal of grease and oil, the removed quantities of grease and oil were increased according to increasing the quantities of influent grease and oil. The regression equation were as follows G.O.removed=0.731 G.O. influent+3.235 (r=0.887) 3. The average of grease and oil removal rate was 76.4% and the standard deviation of grease and oil removal rate daily was 10.6%. 4. G.O. (grease and oil) and BOD, COD, SS showed significant correlationship at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank. (P<0.05). 5. In the secondary treatment, effluent grease & oil and other parameters were analyzed by means of Stepwise multiple regression. Multple regression equation for estimates of effluent grease and oil were as follows. $GO_E=-9.1637+2.0380 SS_E+0.068 SS_I$ (r=0.778) 6. The correlative parameters for the effluent grease and oil seem to be the influent SS and the effluent SS. 7. It was estimated that the removal of grease and oil would be improved by means of improvement of suspended solids removal efficiency but it is necessary to inquire further into the study.

  • PDF

Application of ASM and PHOENICS for Optimal Operation of Wastewater Treatment Plant (하수처리장 운영의 최적화를 위한 ASM, PHOENICS의 적용)

  • Kim, Joon Hyun;Han, Mi-Duck;Han, Yung Han
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.73-82
    • /
    • 2000
  • This study was implemented to find an optimal model for wastewater treatment processes using PHOENICS(Parabolic, hyperbolic or Elliptic Numerical Integration Code Series) and ASM(Activated Sludge Model). PHOENICS is a general software based upon the laws of physics and chemistry which govern the motion of fluids, the stresses and strains in solids, heat flow, diffusion, and chemical reaction. The wastewater flow and removal efficiency of particle in two phase system of a grit chamber in wastewater treatment plant were analyzed to inquire the predictive aspect of the operational model. ASM was developed for a biokinetic model based upon material balance in complex activated sludge systems, which can demonstrate dynamic and spatial behavior of biological treatment system. This model was applied to aeration tank and settling chamber in Choonchun city, and the modeling result shows dynamic transport in aeration tank. PHOENCS and ASM could be contributed for the optimal operation of wastewater treatment plant.

  • PDF

A Study of Machining Optimization of Parts for Semiconductor Plasma Etcher (반도체 플라즈마 식각 장치의 부품 가공 연구)

  • Lee, Eun Young;Kim, Moon Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.28-33
    • /
    • 2020
  • Plasma etching process employs high density plasma to create surface chemistry and physical reactions, by which to remove material. Plasma chamber includes silicon-based materials such as a focus ring and gas distribution plate. Focus ring needs to be replaced after a short period. For this reason, there is a need to find materials resistant to erosion by plasma. The developed chemical vapor deposition processing to produce silicon carbide parts with high purity has also supported its widespread use in the plasma etch process. Silicon carbide maintains mechanical strength at high temperature, it have been use to chamber parts for plasma. Recently, besides the structural aspects of silicon carbide, its electrical conductivity and possibly its enhanced life time under high density plasma with less generation of contamination particles are drawing attention for use in applications such as upper electrode or focus rings, which have been made of silicon for a long time. However, especially for high purity silicon carbide focus ring, which has usually been made by the chemical vapor deposition method, there has been no study about quality improvement. The goal of this study is to reduce surface roughness and depth of damage by diamond tool grit size and tool dressing of diamond tools for precise dimensional assurance of focus rings.

Study of Installation of Sediment Trap Drain Channel to Reduce Soil Erosion from Storm Water Runoff (침사기능 콘크리트 배수로의 유사 유출 저감에 관한 연구)

  • Shin, Hyun-Jun;Won, Chul-Hee;Choi, Yong-Hun;Kim, Tae-Yoo;Choi, Jung-Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.6
    • /
    • pp.95-100
    • /
    • 2010
  • Researchers developed Sediment Trap Drain Channel (STDC) as a solution of the reduction of soil erosion and muddy runoff from a alpine field. The STDC is the one that can take a role of grit chamber by installing the shield made of woods in the concrete channel. The study was conducted 8 kinds of stages according to the amount of soil loss and the inflow. Evaluation factors were ss concentration, turbidity and reduced soil. The results of study showed lessness of ss concentration and turbidity from the lower spot than the upper spot. The average reduction rate of ss concentration was 74 % and the average reduction rate of turbidity was 62 %. It was turned out that the performance related soil loss and muddy runoff of the STDC is effective. The governance was needed to expect the effectiveness of the STDC.

Study on the Improvement of Milling Recovery and Performance (V) -Experimental Study on Rice Whitening Performance of Jet-air Abrasive-Type Whitener - (도정수율(搗精收率)과 성능향상(性能向上)을 위(爲)한 연구(硏究)(V) -분풍(噴風) 연삭식(硏削式) 정미기(精米機)의 정백성능(精白性能)에 관(關)한 실험적(實驗的) 연구(硏究)-)

  • Lee, Sung Bum;Chung, Chang Joo;Noh, Sang Ha
    • Journal of Biosystems Engineering
    • /
    • v.8 no.1
    • /
    • pp.17-29
    • /
    • 1983
  • The milling process is considered as causing one of the greatest grain losses among all the processes in rice post-production. Major source of grain losses in the rice milling is considered as the whitening process. This study was attempted to develop an abrasive-type whitener, the whitening chamber of which being supplied by jet-air evenly and continuously. To investigate the milling performance by the new whitener, three kind of emery-stone grit(#36, #41, and #46), and three levels of rotational speed of emery stone roller (950, 1070, and 1200 rpm) were tested. The jet-air abrasive-type whitener was also compared with the conventional abrasive-type having no jet-air blower in terms of their milling performance. In addition, the effect of different combinations of sequential uses of the abrasive- and friction-type whiteners on the milling performance was also experimentally evaluated. The results of this study are summarized as follows; 1. In general, the whitening system combined with the abrasive type whitener with jet-air supply, which was newly designed, and the existing jet-air friction type whiteners produces more milled- and head-rice by about 0.3% points and 2.8% points, respectively than the system combined with the existing abrasive type without the jet-air supply under the same operational conditions. The former also consumed less electricity by 0.024 KwH per 100kg of milled rice production and gave more milling capacity by about 35 kg/hr. As compared with the conventional whitening system consisting of jet-air friction type whiteners only, the former yielded more milled- and head-rice by 1.5% points and 4.4% points, respectively. 2. The abrasive roller having 46 grit emery was better than the roller having 36 grit in aspects of milling performance and machine efficiency, in general. 3. With regard to the effect of combination method of abrasive type and friction type whiteners, one pass in abrasive type plus three passes in friction type gave better milling performance and energy efficiency than the two passes in abrasive type plus two passes in friction type regardless of the designs of the emery stone rollers. 4. The increase in rotational speed of the emery stone roller from 950 rpm to 1200 rpm presented negative effects on milled and head-rice yields and machine efficiency, but slightly positive effect on milling capacity.

  • PDF

Odorous Emissions from Household-related Sources: A Case Study on a Sewage Treatment Plant (생활악취 배출원의 악취 배출 특성 연구: 하수처리장을 중심으로)

  • Jeon, E.C.;Sa, J.H.;Kim, S.T.;Hong, J.H.;Kim, K.H.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.3
    • /
    • pp.337-351
    • /
    • 2006
  • In this study, to describe the basic characteristics of strong odorous sources, the emissions of odorous compounds from a large-scale sewage treatment plant in K city were investigated. According to this study, the emission patterns of major odorous compounds were distinguished clearly by several factors such as treatment processing types, chemical compositions of odors released, and temporal changes (e.g., seasonal variations). For the purpose of this study, emission rates of odorous compounds were quantified using a dynamic flux chamber (DFC) method from three major treatment (T) processes including T1 (Grit sedimentation basin), T2 (Aeration tank), and T3 (Final sedimentation). When the relative strengths of each emission source were compared, the strongest one was seen from T1 with the maximum of $NH_{3}\;(34.5\;{\mu}g/m^{2}/min)$ followed by $H_{2}S\;(20.4\;{\mu}g/m^{2}/min)($. While the strongest emissions of most odorous compounds were seen commonly from T1, those seen from T2 and T3 were significantly reduced relative to the ones found in T1. Considering the general patterns of odorous emission, it is concluded that control of odors from T1 unit is most important because of its considerably high emission strengths.

Chemically Enhanced Primary Treatment at D Wastewater Treatment Plant (화학적 처리에 의한 1차 하수처리장의 처리효과 개선 -현장시험을 중심으로-)

  • Kwak, Jong W.;Kim, Seung H.;Lee, Chan W.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.99-108
    • /
    • 1997
  • This study examined the feasbility of upgrading D waste water treatment plant which treats incoming wastewater by primary sedimentation only. By adding 20-40 ppm of Hi-PAX into the outlet of the aerated grit chamber, BOD and SS removal efficiences were improved from 29% and 36% to 53 % and 73%,respectively. However, chemically enhanced primary treatment failed to meet the upcoming wastewater quality standard(BOD and SS <20 mg/l) consistently. This was suspected to result from the deteriorated plant return stream. The wastewater treatment by chemical treatment should have increased the amount of the sludge to be removed as the sludge production was increased. Chemically enhanced primary treatment is anticipated to consistently produce effluent of the 1996 standards quality by adjusting the amount of the sludge to be removed. Besides BOD and SS removal, chemically enhanced primary treatment resulted in the improved T-P removal from 30% to 64-74%. However, such benefit was not observed in T-N removal. Improved T-P removal will be expected to help control water pollution in Masan bay.

  • PDF