• 제목/요약/키워드: Grip device

검색결과 39건 처리시간 0.022초

쑥뜸 지열구 보조기구의 개발 (The Development of Supporting Device for Direct Moxibustion)

  • 조봉관;김종원
    • 대한한의학회지
    • /
    • 제38권1호
    • /
    • pp.1-7
    • /
    • 2017
  • Objectives: This paper is focused on the development of supporting device for the direct moxibustion. This device makes one help to do moxibustion on one's head and back for oneself. Without this device, one can't avoidthe other's help to do moxibustion on one's head and back. Methods: The design protocols of the supporting device for the direct moxibustion are determined. And 3 dimensional simulation using Ultimaker's 3D printer was carried out. The parts of the supporting device for direct moxibustion are followings: 1. preparing of the main parts which are divided into an acupuncture touching sting and moxa holder. 2. preparing a grip part. Results: 3 different lengths of the acupuncture touching sting such as 3mm, 4mm, and 5mm were experimented for the perfect burning of moxa. Among them, the acupuncture touching sting with 4mm length was best for the perfect burning and for the organic functional tests. Conclusion: The supporting device for direct moxibustion will be helpful to minimize of the burning of skin, the pain, and the smoke.

쑥뜸 지열구 보조기구의 개발 (The Development of Supporting Device for Direct Moxibustion)

  • 조봉관;김종원
    • 대한한의진단학회지
    • /
    • 제20권2호
    • /
    • pp.77-84
    • /
    • 2016
  • Objectives This paper is focused on the development of supporting device for the direct moxibustion. This device makes one help to do moxibustion on one's head and back for oneself. Without this device, one can't avoid the other's help to do moxibustion on one's head and back. Methods The design protocols of the supporting device for the direct moxibustion are determined. And 3 dimensional simulation using Ultimaker's 3D printer was carried out. The parts of the supporting device for direct moxibustion are followings: 1. preparing of the main parts which are divided into an acupuncture touching sting and moxa holder. 2. preparing a grip part. Results 3 different lengths of the acupuncture touching sting such as 3mm, 4mm, and 5mm were experimented for the perfect burning of moxa. Among them, the acupuncture touching sting with 4mm length was best for the perfect burning and for the organic functional tests. Conclusion The supporting device for direct moxibustion will be helpful to minimize of the burning of skin, the pain, and the smoke.

Constitutive law for wedge-tendon gripping interface in anchorage device - numerical modeling and parameters identification

  • Marceau, D.;Fafard, M.;Bastien, J.
    • Structural Engineering and Mechanics
    • /
    • 제15권6호
    • /
    • pp.609-628
    • /
    • 2003
  • Mechanical anchorage devices are generally tested in the laboratory and may be analyzed using the finite element method. These devices are composed of many components interacting through diverse contact interfaces. Generally, a Coulomb friction law is sufficient to take into account friction between smooth surfaces. However, in the case of mechanical anchorages, a gripping system, named herein the wedge-tendon system, is used to anchor the prestressing tendon. The wedge inner surface is made of a series of triangular notches designed to grip the tendon. In this particular case, the Coulomb law is not adapted to simulate the contact interface. The present paper deals with a new constitutive contact/gripping law to simulate the gripping effect. A parameter identification procedure, based on experimental results as well as on a finite element/neural network approach, is presented. It is demonstrated that all parameters have been selected in a satisfactory way and that the proposed constitutive law is well adapted to simulate the wedge gripping effect taking place in a mechanical anchorage device.

굴삭기를 이용한 돌쌓기 장치 개발 (Development of Stone Piling-up Device for an Excavator)

  • 권순광;김용석;이동영;이창돈;양순용
    • 유공압시스템학회논문집
    • /
    • 제5권3호
    • /
    • pp.9-14
    • /
    • 2008
  • The application of an excavator can be expanded to various works through change of end-effector. In this paper, a gripper, which can pick up and rotate a fixed formal stone, was developed. The device was designed and produced to pick up and rotate a stone for an excavator. The maximum weight of stone was computed to prevent from reversal in according to each displacement of attachments. The necessary force of a hydraulic cylinder to grip a stone was obtained by simulation.

  • PDF

파지 형태 인식을 통한 휴대 단말용 사용자 인터페이스 설계 (Designing Mobile User Interface with Grip-Pattern Recognition)

  • 장욱;김기응;이현정;조준기;소병석;심정현;양경혜;조성정;박준아
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2006년도 학술대회 1부
    • /
    • pp.678-683
    • /
    • 2006
  • 본 논문에서는 휴대 단말을 위한 새롭고 직관적인 응용 프로그램 구동 방식을 제안한다. 핵심 아이디어는 사용자가 휴대 단말을 사용할 때 자연스럽게 발생하는 파지 형태를 응용프로그램 구동의 근거로 활용하는 것이다. 이를 위해 정전 용량 방식 터치 센서 시스템을 제작하고 이를 휴대 단말의 케이스 하부에 장착을 해 사용자의 파지 형태를 취득한다. 획득된 파지 형태의 인식을 위해 제안한 시스템에 특화된 인식기 및 전처리와 후처리 알고리즘을 개발하였다. 제안된 사용자 인터페이스 시스템의 효용성을 검증하기 위해 인식률 테스트를 수행한다.

  • PDF

4가지 선회보조 장치가 운전 성능에 미치는 영향: 장애 유무와 운전면허 유무에 따른 비교 (Influence of Four Types of Steering Assistive Devices on Driving Performance: Comparison of Normal and Disabled People with and without Driver's License)

  • 송정헌;김용철
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권1호
    • /
    • pp.32-42
    • /
    • 2017
  • The aim of this study was to evaluate driving performance of Healthy and disabled groups (with or without driver's license) to control steering wheel by using steering assistive devices in the driving simulator. The persons with partial loss of use of all four limbs have problems in operation of the motor vehicle because of functional loss to operate steering wheel. Therefore, if steering assistive devices for grasping the steering wheel are used to control the vehicle on the road in persons with disabilities, the disabled persons can improve mobility in their community life by driving a motor vehicle safely. Ten healthy subjects (with or w/o driver's license) and ten subjects with physical disabilities (with or w/o driver's license) were involved in this study to evaluate driving performance to operate steering wheel by using four types of steering assistive devices (Single-pin, V-grip, Palm-grip, Tri-pin) in driving simulator. STISim Drive 3 software was used to test the steering performance in four scenarios: straight road at low and high speed of vehicle (40 km/h and 80 km/h), curved road at low and high speed of vehicle (40 km/h and 80 km/h). This study used two-way ANOVA in order to compare the effects of two factors (type of steering assistive device and subject group) in the three dependent variables of driving performance (the lateral position of vehicle, standard deviation of lateral position representing the variation of the left and right movement of the vehicle and the number of line crossing). The mean values of the three dependent variables (lateral position, standard deviation of lateral position, the number of line crossing) of steering performance were statistically significantly smaller for the healthy or disabled groups with driver's license than the other groups without driver's license on the curved road at high speed of vehicle compared to low speed of vehicle.

담배 벌크건조기의 래크용 전동발달기 장치 개발 (Development of Electric Hoist Device for Rack in Tobacco Bulk curing Barn)

  • 김용암;류명현;백종운
    • 한국연초학회지
    • /
    • 제23권1호
    • /
    • pp.90-93
    • /
    • 2001
  • In order to save hanging labor hours and reduce work intensity for bulk curing of the flue-cured tobacco, and electric hoist was developed. It consists of a pair of square steel frames with side plates and rolling casters to move back and forth on the second tire of bulk barn, and wire rope type lift was attached to the beneath of its top center. The lift driven by DC motor could be controlled by operating switch with one limit switch and control box, and a scissors shaped gripper was deviced to grip tobacco rack to the end of wire rope. As the results of experiments with electric hoist, labor hours for hanging could be saved by 30 to 40% as compared with those in conventional method. With simple and light structure, it was possible for even woman to load the harvested tobacco, and it could be recommended for farmers to use this device with reasonable price.

  • PDF

발전소 고온부의 수명 평가를 위한 소형 시편용 크리프 시험기의 개발 (Development of Small-Specimen Creep Tester for Life Assessment of High Temperature Components of Power Plant)

  • 김효진;정용근;박종진
    • 대한기계학회논문집A
    • /
    • 제24권10호
    • /
    • pp.2597-2602
    • /
    • 2000
  • The most effective means of evaluating remaining life is through the creep testing of samples removed from the component. But sampling of large specimen from in-service component is actually impossible. So, sampling device and small-specimen creep tester have been applied. Sampling device has been devised to extract mechanically small samples by hemispherical, diamond -coated cutter from the surface of turbine rotor bores and thick-walled pipes without subsequent weld repairs requiring post weld heat treatment. A method of manufacturing small creep specimen, 2min gage diameter and 10min gage length, using electron beam welding to attach grip section, has been proven. Small-specimen creep tester has been designed to control atmosphere to prevent stress increment by oxidation during experiment. To determine whether the small specimens successfully reproduce the behavior of large specimens, creep rupture tests for small and large specimens have been performed at identical conditions. Creep rupture times based on small specimens have closely agreed within 5% error compared with that of large specimen. The errors in rupture time have decreased at longer test period. This comparison validates the procedure for fabricating and testing on small specimen. This technique offers potential as an efficient method for remaining life assessment by direct sampling from in -service high temperature components.

햅틱 연동 능동 보행보조장치 개발 (Development of an Active Gait Assistive Device with Haptic Information)

  • 표상훈;오민균;윤정원
    • 제어로봇시스템학회논문지
    • /
    • 제21권6호
    • /
    • pp.553-559
    • /
    • 2015
  • The purpose of this research is to develop a gait assistive device to enhance the gait stability and training efficiency of stroke patients. The configuration of this device is mainly composed of a motored wheel and a single cane whose lower end is attached to a motored wheel frame. A patient can feel haptic information from continuous ground contact from the wheel while walking through the grip handle. In addition, the wheeled cane can avoid using excessive use of the patient's upper limb for weight support and motivate the patient to use a paralyzed lower limb more actively. Moreover, the proposed device can provide intuitive and safe user interaction by integrating a force sensor and a tilt sensor equipped to the cane frame, and a switch sensor at the cane's handle. The admittance control has been implemented for the patient to change the walking speed intuitively by using the interaction forces at the handle. A hemi-paretic stroke patient participated in the walking assistive experiments as a pilot study to verify the effectiveness of the proposed haptic cane system. The results showed that the patient could improve walking speed and muscle activations during walking with a constant speed mode of the haptic cane. Moreover, the patient could maintain the preferred walking speeds and gait stability regardless of the magnitude of resistance forces with the admittance control mode of the haptic cane. The proposed robotic gait assistive device with a simple and intuitive mechanism can provide efficient gait training modes to stroke patients with high possibilities of widespread utilizations.

백밸브마스크를 이용한 1인 심폐소생술에서 구조자 위치 변화에 따른 가슴압박과 인공호흡의 질 변화 연구 (Comparison of cardiopulmonary resuscitation quality using the over-the-head and lateral conventional positions with a bag-valve-mask device performed by a single rescuer : A manikin study)

  • 엄태환;정형근
    • 한국응급구조학회지
    • /
    • 제20권1호
    • /
    • pp.7-15
    • /
    • 2016
  • Purpose: There are few studies on the quality of cardiopulmonary resuscitation (CPR) performed by a single rescuer using a bag-valve-mask device. The aim of this study is to compare CPR quality outcomes according to the rescuer's position or mask fixation grip method and to determine the optimal means of achieving therapeutic goals. Methods: The three CPR methods were defined as over-the-head, lateral-superior, and lateral-inferior, depending on the rescuer's position or mask fixation hand placement. CPR quality was estimated for 83 paramedic students who performed 5 minutes of CPR in a randomized sequence on a manikin using each of the three methods. Results: The over-the-head method showed no advantage for cardiac compression and ventilation quality, but minimized the rescuer's fatigue score. Conclusion: In contrast to previous studies or prevailing beliefs, the lateral-superior position is optimal for achieving therapeutic goals with moderate or minimal rescuer fatigue.