• Title/Summary/Keyword: Grid-Connection

Search Result 307, Processing Time 0.023 seconds

Operation Performance of a Polymer Electrolyte Fuel Cell Cogeneration System for Residential Application (가정용 고분자연료전지 시스템의 운전 방법에 따른 성능 비교)

  • Lee, W.Y.;Jeong, K.S.;Yu, S.P.;Um, S.K.;Kim, C.S.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.16 no.4
    • /
    • pp.364-371
    • /
    • 2005
  • Fuel cell systems(FCS) have a financial and environmental advantage by providing electricity at a high efficiency and useful heat. For use in a residence, a polymer electrolyte fuel cell system(PEFCS) with a battery pack and a hot water storage tank has been modelled and simulated. The system is operated without connection to grid line. Its electric conversion efficiency and heat recovery performance are highly dependent on operation strategies and also on the seasonal thermal and electric load pattern. The output of the fuel cell is controlled stepwise as a function of the state of the battery and/or the storage water tank. In this study various operation strategies for cogeneration fuel cell systems are investigated. Average fuel saving rates at different seasons are calculated to find proper load management strategy. The scheme can be used to determine the optimal operating strategies of PEFCS for residential and building applications.

An Assessment on Effect of Facility and Electrical Safety During the Flooding of the Photovoltaic Power System (태양광 발전설비의 침수 시 설비영향 및 전기적 안전성 평가)

  • Park, Chan-Eom;Jung, Jin-Soo;Han, Un-Ki;Lim, Hyun-Sung;Song, Young-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.38-44
    • /
    • 2014
  • The photovoltaic power system is performing power generation by being installed in outdoors. Therefore it has the characteristics affected by environmental factors. In particular, if the solar power generation facility connected to the grid, the power can be generated continuously in a state of being secured operating voltage of the inverter and solar irradiation. In that case, if an abnormal situation such as flooding or heavy rains has occur, the possibility of electric shock or damage of facilities due to current leakage or a floating matters is present. In this paper, we performed electrical safety assessment about the connection part, junction box and cable of the solar module when the solar power system was flooded. we also assessed whether or not the leakage current is occurred in case of the cable was damaged. As a result, in case of the leakage current is large, we can be known that it is the risk of electric shock as well as cause of inverter damage.

A Study on the Performance Analysis for the CPV Module Applying Sphericalness Lens (구형렌즈를 적용한 CPV 모듈 발전성능 분석에 관한 연구)

  • Jeong, Byeong-Ho;Kim, Nam-Oh;Lee, Kang-Yoen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.293-297
    • /
    • 2010
  • Next generation concentrating photovoltaic technologies could have a large-scale impact on world electricity production once they will become economically attractive and grid parity will be reached. Multi-junction solar cells will be characterised by a high value of the cell economical performance index if the cells were able to operate at high concentration level. Concentrating the sunlight by optical devices like lenses or mirrors reduces the area of expensive solar cells or modules, and, moreover, increases their efficiency. Accurate and reliable tracking is an important issue to maintain high the CPV system output power. Further, for high concentration CPV systems, the actual tracker cost is about 20% of the total CPV system cost. In this paper high-concentration is defined as systems using concentration ratios well above 100 times the one sun intensity and trackerlss CPV system studied. Using sphericalness lens and parallel MJ cell connection method were suggested and achieved experiment on a clear day in summer. Development of these high performance multi-junction CPV module promises to accelerate growth in photovoltaic power generation.

Design of Falling Context-aware System based on Notification Service using Location Information and Behavior Data

  • Kwon, TaeWoo;Lee, Daepyo;Lee, Jong-Yong;Jung, Kye-Dong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.42-50
    • /
    • 2018
  • The majority of existing falling recognition techniques provide service by recognizing only that the falling occurred. However, it is important to recognize not only the occurrence of falling but also the situation before and after the falling, as well as the location of the falling. In this paper, we design and propose the falling notification service system to recognize and provide service. This system uses the acceleration sensor of the smartphone to recognize the occurrence of a falling and the situation before and after the falling. In order to check the location of falling, GPS sensor data is used in the Google Map API to map to the map. Also, a crosswalk map converted into grid-based coordinates based on the longitude and latitude of the crosswalk is stored, and the locations before and after falling are mapped. In order to reduce the connection speed and server overload for real-time data processing, fog computing and cloud computing are designed to be distributed processing.

Analysis on the Improvement of Power Capacity Increase in the Transformer-Type SFCL with Neutral Lines (중성선을 갖는 변압기형 초전도 한류기의 용량증대 개선 연구)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Kim, Deog-Goo;Go, Sung-Pil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1438-1443
    • /
    • 2011
  • The increase of power capacity in the superconducting fault current limiter (SFCL) is essential for application into the power grid. To achieve this, when superconducting units were connected in series and parallel, the unbalanced quenching characteristics between superconducting units generated by different critical current behavior should be improved. In the transformer-type SFCL, the superconducting units connected in series could be simultaneously quenched by the connection of neutral lines between secondary coils and superconducting units. From this the consumed power in superconducting units was equally distributed. In addition, the more the turn ratio of the transformer was reduced, the more consumed power in the superconducting units was reduced by the decrease of the induction voltage generated in the superconducting units. From those results, the transformer-type SFCL using neutral lines could increase the power capacity of the SFCL by the equal power division into the superconducting units.

Numerical Simulation of Tsunami Impact Load Using 3-Dimensional Particle Method (파랑 충격하중에 관한 3차원 입자법 수치모사)

  • Kim, Young-Hun;Jung, Sung-Jun;Lee, Byung-Hyuk;Hwang, Sung-Chul;Park, Jong-Chun
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.6
    • /
    • pp.42-46
    • /
    • 2007
  • The impact of a single wave generated by a dam break with a tall structure is modeled with a three-dimensional version of the Moving particle semi-implicit (MPS) method. The particle method is more feasible and effective than methods based on grid connection problems involving violent free surface motions. In the present study, the Tsunami impact load and the change of longitudinal velocity component around the structure, which are obtained from the numerical simulation, are compared to those from experiments.

Scheme for Reducing Harmonics in Output Voltage of Modular Multilevel Converters with Offset Voltage Injection

  • Anupom, Devnath;Shin, Dong-Cheol;Lee, Dong-Myung
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1496-1504
    • /
    • 2019
  • This paper proposes a new THD reduction algorithm for modular multilevel converters (MMCs) with offset voltage injection operated in nearest level modulation (NLM). High voltage direct current (HVDC) is actively introduced to the grid connection of offshore wind powers, and this paper deals with a voltage generation technique with an MMC for wind power generation. In the proposed method, third harmonic voltage is added for reducing the THD. The third harmonic voltage is adjusted so that each of the pole voltage magnitudes maintains a constant value with a maximum number of (N+1) levels, where N is the number of sub-modules per arm. By using the proposed method, the THD of the output voltage is mitigated without increasing the switching frequency. In addition, the proposed method has advantageous characteristics such as simple implementation. As a part of this study, this paper compares the THD results of the conventional method and the proposed method with offset voltage injection to reduce the THD. In this paper, simulations have been carried out to verify the effectiveness of the proposed scheme, and the proposed method is implemented by a HILS (Hardware in the Loop Simulation) system. The obtained results show agreement with the simulation results. It is confirmed that the new scheme achieved the maximum level output voltage and improved the THD quality.

Resonance Investigation and Active Damping Method for VSC-HVDC Transmission Systems under Unbalanced Faults

  • Tang, Xin;Zhan, Ruoshui;Xi, Yanhui;Xu, Xianyong
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1467-1476
    • /
    • 2019
  • Grid unbalanced faults can cause core saturation of power transformer and produce lower-order harmonics. These issues increase the electrical stress of power electronic devices and can cause a tripping of an entire HVDC system. In this paper, based on the positive-sequence and negative-sequence impedance model of a VSC-HVDC system as seen from the point of common connection (PCC), the resonance problem is analyzed and the factors determining the resonant frequency are obtained. Furthermore, to suppress over-voltage and over-current during resonance, a novel method using a virtual harmonic resistor is proposed. The virtual harmonic resistor emulates the role of a resistor connected in series with the commutating inductor without influencing the active and reactive power control. Simulation results in PSCAD/EMTDC show that the proposed control strategy can suppress resonant over-voltage and over-current. In addition, it can be seen that the proposed strategy improves the safety of the VSC-HVDC system under unbalanced faults.

Considering the accuracy and efficiency of the wireless sensor network Support Plan (무선 센서 네트워크에서의 정확도와 효율성을 고려한 기술 지원 방안)

  • You, Sanghyun;Choi, Jaehyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.96-98
    • /
    • 2014
  • Wireless Sensor Network(WSN) is a wireless real-time information(Acquired from the sensor nodes that have the computing power and wireless communication capabilities.) collected, and to take advantage of processing techniques. Currently it is very diverse, such as environmental monitoring, health care, security, smart home, smart grid applications is that. Thus it is required in the wireless sensor network, the algorithm for the efficient use of the limited energy capacity. Suggested by the algorithm for selecting a cluster head node for a hybrid type and clustered, by comparing the amount of energy remaining and a connection between the nodes In this paper, we aim to increase efficiency and accuracy of the wireless sensor network.

  • PDF

An Analysis of Policy Initiatives and Benefit Sharing Schemes to Support Floating Solar Power Plants (수상태양광 지원제도와 이익공유 방식 분석)

  • Ahn, Seunghyeok;Soh, Yoonmie;Ryu, Hojae;Lee, Hyoeun;Hwangbo, Eunyoung;Yun, Sun-Jin
    • New & Renewable Energy
    • /
    • v.17 no.4
    • /
    • pp.9-27
    • /
    • 2021
  • Floating solar power markets are rapidly growing worldwide. The main policy instrument utilized to expand renewable energy use in foreign countries with many floating solar power installations is Feed-in-Tariffs (FITs). Foreign countries apply FIT to projects that have a secured grid connection, and lately, there has been a change in the direction of introducing or expanding auction systems. Vietnam and Taiwan give higher FIT to floating solar installations than land solar ones, and China, Vietnam, and Taiwan have higher FITs for certain regions. Compared to foreign countries where large-scale floating solar power installations have been installed, Korea has utilized Renewable Energy Certificate (REC) weights for residents' participation are provided additionally under the Renewable Portfolio Standard (RPS). In contrast to Korea, where residents' participation and benefit profit sharing are emphasized, the Netherlands provides opportunities for local residents to participate in floating solar power projects through cooperatives to improve the residents' acceptance.