• 제목/요약/키워드: Grid-Cell

검색결과 627건 처리시간 0.025초

새로운 고효율 계통연계 1kW 연료전지용 PCS (A Noval High Efficiency Grid Connected 1kW PCS for Fuel Cell)

  • 김태진
    • 한국수소및신에너지학회논문집
    • /
    • 제19권5호
    • /
    • pp.417-422
    • /
    • 2008
  • In this paper, a novel DC/DC low-voltage high-current converter circuit is proposed to improve the efficiency of power converter used in the grid-connected fuel-cell generator system. We proposed a novel high efficiency grid-connected power conditioning system for RPG fuel cell. On the result of that, the loss of system was decreased rapidly by driving stack within the condition of maximum efficiency. The peak currents of the current-type inductor and the transformer's coil are reduced by synchronizing switching frequency of Buck-type converter is increased twice as the Push-Pull converter's switching frequency. The novel structure of DC/DC converter is able to realize ZVS-ZCS in fuel-cell system is proposed. The proposed switching component of Push-Pull converter has the ZVS and ZCS function by using the circuit of new passive clamp.

노상 주차 차량 탐지를 위한 YOLOv4 그리드 셀 조정 알고리즘 (YOLOv4 Grid Cell Shift Algorithm for Detecting the Vehicle at Parking Lot)

  • 김진호
    • 디지털산업정보학회논문지
    • /
    • 제18권4호
    • /
    • pp.31-40
    • /
    • 2022
  • YOLOv4 can be used for detecting parking vehicles in order to check a vehicle in out-door parking space. YOLOv4 has 9 anchor boxes in each of 13x13 grid cells for detecting a bounding box of object. Because anchor boxes are allocated based on each cell, there can be existed small observational error for detecting real objects due to the distance between neighboring cells. In this paper, we proposed YOLOv4 grid cell shift algorithm for improving the out-door parking vehicle detection accuracy. In order to get more chance for trying to object detection by reducing the errors between anchor boxes and real objects, grid cells over image can be shifted to vertical, horizontal or diagonal directions after YOLOv4 basic detection process. The experimental results show that a combined algorithm of a custom trained YOLOv4 and a cell shift algorithm has 96.6% detection accuracy compare to 94.6% of a custom trained YOLOv4 only for out door parking vehicle images.

자바 애플릿을 이용한 2차원 혼합형 비정렬 격자 생성 프로그램의 개발 (DEVELOPMENT OF 2-D UNSTRUCTURED HYBRID GRID GENERATION PROGRAM USING JAVA APPLET)

  • 이장훈;조금원;김병수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 추계학술대회논문집
    • /
    • pp.65-70
    • /
    • 2009
  • In this paper a hybrid grid generation program for general 2-D region is introduced. The program is developed by using JAVA programming language, and it can be used either as an application program on a local computer or as an applet in the network environment. The hybrid grid system for a 2-D problem means a combination of triangular cells and quadrilateral cells, and it can offer both of the high flexibility of triangular cells and the high accuracy and efficiency of structured-type quadrilateral cells. To accommodate a quadrilateral-cell region and a triangular-cell region into one computational domain, it is importance to take good care of the interface between two different regions so that overall good grid quality can be maintained. In this research advancing layer method(ALM) augmented by elliptic smoothing method is used for the quadrilateral-cell region and advancing front method(AFM) is used for the triangular-cell region. A special treatment technique for the interface between those two regions is also developed. The interface treatment technique is basically to prevent the propagation of small cell size due to ALM method into the triangular region and maintain the smooth transition of cell-size scale between two different regions. By applying current technique high-quality hybrid grids for general 2-D regions can be easily generated, and typical grid generation results and flow solutions are demonstrated.

  • PDF

Grid-tied Power Conditioning System for Fuel Cell Composed of Three-phase Current-fed DC-DC Converter and PWM Inverter

  • Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon;Cha, Han-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.255-262
    • /
    • 2011
  • This paper proposes a grid-tied power conditioning system for fuel cell, which consists of three-phase current-fed DC-DC converter and three-phase PWM inverter. The three-phase current-fed DC-DC converter boosts fuel cell voltage of 26-48 V up to 400 V with zero-voltage switching (ZVS) scheme, while the three-phase PWM(Pulse Width Modulation) inverter controls the active and reactive power supplied to the grid. The operation of the proposed power conditioning system with fuel cell model is verified through simulations with PSCAD/EMTDC software. The feasibility of hardware implementation is verified through experimental works with a laboratory prototype with 1.2 kW proton exchange membrane (PEM) fuel cell stack. The proposed power conditioning system can be commercialized to interconnect the fuel cell with the power grid.

직교 격자 계에서 주조 유동 시뮬레이션의 정확한 해석 방법 (Mold Filling Simulation with Cut Cell in the Cartesian Grid System)

  • 최영심;남정호;홍준호;황호영
    • 한국주조공학회지
    • /
    • 제29권1호
    • /
    • pp.33-37
    • /
    • 2009
  • Cartesian grid system has mainly been used in the casting simulation even though it does not nicely represent sloped and curved surfaces. These distorted boundaries cause several problems. A special treatment is necessary to clear these problems. In this paper, we propose a new method that can consider the cutting cells which are cut by casting and mold based on the partial cell treatment (PCT). This method provides a better representation of geometry surface and will be used in the computation of velocities that are defined on the cell boundaries in the Cartesian grid system. Various test examples for several casting process were computed and validated. The analysis results of more accurate fluid flow pattern and less momentum loss owing to the stepped boundaries in the Cartesian grid system were confirmed. By using the cut cell method, performance of computation gets better because of reducing the whole number of meshes.

데토네이션 셀 구조 포착을 위한 격자 해상도 요구 조건 (Grid Requirements for Capturing Detonation Cell Structure)

  • 최정열
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제24회 춘계학술대회논문집
    • /
    • pp.431-434
    • /
    • 2005
  • 데토네이션 파의 셀 구조를 모사하기 위한 격자 해상도 요구 조건을 파악하기 위하여 여러 영역의 데토네이션 현상에 대하여 반응 속도 상수와 격자 해상도를 바꾸어가며 일련의 해석을 수행 하였다. 서로 다른 영역의 데토네이션 현상에 대하여 정상 상태 ZND 구조와 계산 결과를 비교하여 살펴봄으로써, 최소 격자 크기와 계산 영역의 크기에 대한 결론을 도출하였다.

  • PDF

디지털제어 DC-DC컨버터로 구성된 계통연계 연료전지발전 시뮬레이션모델 개발 (Development of Simulation Model for Grid-tied Fuel-Cell Power Generation with Digital Controlled DC-DC Converter)

  • 주영아;차민영;한병문;강태섭;차한주
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1728-1734
    • /
    • 2009
  • This paper proposes a new power conditioning system for the fuel cell power generation, which consists of a ZVS DC-DC converter and 3-phase inverter. The ZVS DC-DC converter with a digital controller boosts the fuel cell voltage of 26-50V up to 400V, and the grid-tie inverter controls the active power delivered to the grid. The operation of proposed power conditioning system was verified through simulations with PSCAD/EMTDC software. The feasibility of hardware implementation was verified through experimental works with a laboratory prototype, which was built with 1.2kW PEM fuel-cell stack, 1kW DC-DC converter, and 3kW PWM inverter. The proposed system can be utilized to commercialize an interconnection system for the fuel-cell power generation.

CAD 형상 데이터를 이용한 비정렬 격자 자동 생성을 위한 격자셀 크기 지정 기법 (A NEW CELL SIZING METHOD FOR AUTOMATIC UNSTRUCTURED GRID GENERATION USING CAD SURFACE DATA)

  • 이봉주;김병수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.120-125
    • /
    • 2007
  • In this paper a new cell sizing method is proposed. The new method calculates cell size at a point using given size control elements directly without the aid of background grid as other cell sizing algorithms do. The calculation method and related definitions are described in detail, and typical cell sizing results are given.

  • PDF

에너지 저장장치를 이용한 마이크로 그리드의 최적운영 및 신뢰도 지수 개선 (Optimal Operation Scheme and Reliability Index Improvement of Micro Grid Using Energy Storage Systems)

  • 김규호
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.205-210
    • /
    • 2014
  • The micro grid considered in this paper consists of a diesel generator, a photovoltaic array, a wind turbine, a fuel cell, and a energy storage system. This paper explains and simulates the micro grid components in terms of accuracy and efficiency of having a system model based on the costs of fuel as well as operation and maintenance. For operational efficiency, the objective function in a diesel generator consists of the fuel cost function similar to the cost functions used for the conventional fossil-fuel generating plants. The wind turbine generator is modeled by the characteristics of variable output. The optimization is aimed at minimizing the cost function of the system while constraining it to meet the customer demand and safety of micro grid. The operating cost in fuel-cell system includes the fuel costs and the efficiency for fuel to generate electric power. To develop the overall system model gives a possibility to minimize of the total cost of micro grid. The application of optimal operation can save the interruption costs as well as the operating costs, and improve reliability index in micro grid.

새만금호 3차원 수리.수질모델(EFDC)의 수치격자 민감도 분석 (A Sensitivity Analysis on Numerical Grid Size of a Three-Dimensional Hydrodynamic and Water Quality Model (EFDC) for the Saemangeum Reservoir)

  • 전지혜;정세웅
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.26-37
    • /
    • 2012
  • Multi-dimensional hydrodynamic and water quality models are widely used to simulate the physical and biogeochemical processes in the surface water systems such as reservoirs and estuaries. Most of the models have adopted the Eulerian grid modeling framework, mainly because it can reasonably simulate physical dynamics and chemical species concentrations throughout the entire model domain. Determining the optimum grid cell size is important when using the Eulerian grid-based three-dimensional water quality models because the characteristics of species are assumed uniform in each of the grid cells and chemical species are represented by concentration (mass per volume). The objective of this study was to examine the effect of grid-size of a three dimensional hydrodynamic and water quality model (EFDC) on hydrodynamics and mass transport in the Saemangeum Reservoir. Three grid resolutions, respectively representing coarse (CG), medium (MG), and fine (FG) grid cell sizes, were used for a sensitivity analysis. The simulation results of numerical tracer showed that the grid resolution affects on the flow path, mass transport, and mixing zone of upstream inflow, and results in a bias of temporal and spatial distribution of the tracer. With the CG, in particular, the model overestimates diffusion in the mixing zone, and fails to identify the gradient of concentrations between the inflow and the ambient water.