• Title/Summary/Keyword: Grid test

Search Result 952, Processing Time 0.038 seconds

Effects of Alloying Elements on the Corrosion Layer Formation of Pb-Grid/Active Materials Interface (Pb 기판/활물질 계면의 부식층형성에 미치는 합금원소영향)

  • Oh, Se-Woong;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.5
    • /
    • pp.225-233
    • /
    • 2007
  • Effects of alloying elements on the corrosion layer formation of Pb-grid/active materials interface has been researched for improvement of corrosion resistance of Pb-Ca alloy. For this research, various amounts of alloying elements such as Sn, Ag and Ba were added to the Pb-Ca alloys and investigated their corrosion behaviors. Batteries fabricated by using these alloys as cathode grids were subjected to life cycle test. Overcharge life cycle test was carried out at $75^{\circ}C$, 4.5 A, for 110 hrs. with KS standard (KSC 8504). And then, after keeping the battery with open circuit state for 48 hr, discharge was carried out at 300A for 30 sec. Corrosion morphology and interface between Pb-grid and active materials were investigated by using ICP, SEM, WDX, and LPM. Corrosion layer of Pb-Ca alloy got thicken with increasing Ca content. For Pb-Ca-Sn alloy, thickness of corrosion layer decreased as Sn and Ag content increased gradually. In case of Pb-Ca-Sn-Ba alloy, thickness of corrosion layer decreased up to 0.02 wt% Ba addition, whereas, it was not changed in case of above 0.02 wt% Ba addition.

The Quantitative Evaluation of Aging State of Field Composite Insulators Based on Trap Characteristics and Volume Resistivity-Temperature Characteristics

  • Liang, Ying;Gao, Li-Juan;Dong, Ping-Ping;Gao, Ting
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1355-1362
    • /
    • 2018
  • In order to obtain a better understanding of the ageing process of the field composite insulators, it is necessary to explore a quantitative-valuation method for the aging state evaluation. And the linear relationship between volume resistivity and temperature is proposed. In this paper, the composite insulators with different lengths of operating lives from two manufacturers were tested. The relationship between trap characteristics and volume resistivity-temperature characteristics were analyzed based on Thermal Stimulated Current (TSC), volume resistivity-temperature test, Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectroscopy (FTIR). Furthermore, the application of trap characteristics in the quantitative evaluation of aging state of composite insulators was discussed. The results showed that there was a general negative correlation between the relative variation ratio of trap charges and the volume resistivity-temperature characteristics. Meanwhile, the physicochemical properties would change with the aging time, which would result in the increasing of electron traps. Combined with the TSC and volume resistivity test results, the trap characteristic thresholds which indicated the serious age of the composite insulators had been proposed.

A Development and Performance Test of Voltage Measurement Accuracy Assessment System for Distribution Equipment (배전기기 전압계측 정밀도 평가시스템 개발 및 성능시험)

  • Cho, Jin-Tae;Kim, Ju-Yong;Lee, Hak-Ju;Kim, Jae-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.83-89
    • /
    • 2013
  • Power distribution system has been changed from radial system to closed loop or mesh system due to connection of distributed generation growth. Data from distribution equipments which are installed at distribution line is required to be accurate for the performance of DMS(Distribution Management System). This paper analyzes the voltage measurement data from distribution equipment. However, the results of the analysis are confirmed to have some errors in voltage measurement data from distribution equipment. These errors come from aging of voltage sensor in distribution equipment and inaccurate data transfer to FRTU(feeder remote terminal unit) through the controller. The main problem is that the voltage measurement data of distribution equipment can not be assessed after it's first installation at the distribution line. The voltage measurement accuracy assessment system is to assess the voltage measurement data from distribution equipment on hot-line. This study had a field test to verify the performance of system.

A Study on Dose Reduction in Infant Skull Radiography (유아 두개골 방사선촬영에서 피폭선량 감쇄에 관한 연구)

  • Ahn, Byoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.387-392
    • /
    • 2017
  • When an infant has visited a hospital due to skull fracture, the rupture of a blood vessel, or skin wounds on the head resulted from an incident, accident, traffic accident, or disease, he/she becomes to undergo anterior/posterior and lateral skull imaging, which is a head test at the department of radiology. In the head test, if the adult skull imaging grid is applied to the imaging, the secondary radiation will be removed to enhance the contrast of the image. However, among the radiation exposure conditions, the tube voltage should be enhanced by 8~10 kVp leading to an increase in the patient exposure. The present study was conducted under assumption that if the same images can be obtained from infant skull imaging without using the skull imaging grid, the exposure dose will be reduced and the artifacts due to grid cut off can be prevented. The researcher measured the radiation dosage using a radiation meter and conducted the subjective evaluation (ROC, receiver operating characteristic) among medical image evaluation methods. Based on the results, when the images were taken without using the grid, the exposure dose was reduced by 0.019 mGy in the anterior/posterior imaging and by 0.02 mGy in the lateral imaging and the image evaluation score was higher by 4 points. In conclusion, if the images of the skulls of infants that visited the hospital are taken with out using the grid, the exposure dose can be reduced, the image artifacts due to grid cut off can be prevented, and the lifespan of the X-ray tube will be extended.

Islanding detection of grid-connected inverter in parallel operation (병렬운전에서의 계통연계형 인버터의 단독운전 검출)

  • Jung, Young-Seok;Yu, Byung-Gyu;So, Jung-Hun;Yu, Gwon-Jong;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.232-233
    • /
    • 2007
  • In this paper, phenomenon of islanding parallel inverters in an ac-distributed system is proposed. The paper explores the test results of the parallel-connected inverters in grid-connected system. The test results are devised and analyzed taking into account the power quality and the islanding performance. The islanding test methods applied. Experimental results are provided from two 2 kVA inverters connected in parallel, showing the features of islanding test.

  • PDF

Analysis of NEESgrid Computing and System for Korean Construction Test Equipments Infrastructure (NEESgrid 시스템의 구성과 기능별 역할 분석을 통한 우리나라 건설실험시설의 네트워크 시스템 구축)

  • Jeong, Tai Kyeong;Shim, Nak Hoon;Park, Young Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.689-692
    • /
    • 2006
  • This paper presents the developments of Grid computing architecture which is use many data and resources from distributed and parallel system for construction test equipments, i.e., large scale computer networks meant to provide access to massive computational facilities for very large communities of users, drawing upon experiences of existing Grids architecture. In this paper, we present an efficient way to construct a construction test equipment infrastructure.

Aerodynamic Analysis of 18% Thick Airfoil(Case 1) with Computational Fluid Dynamics (전산해석을 활용한 두께비 18%익형(Case1)의 공력특성 분석)

  • Kim, Cheolwan;Lee, Yung-gyo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.3
    • /
    • pp.212-216
    • /
    • 2017
  • Aerodynamic analysis for the airfoil, KARI-11-180 having 18% thickness ratio, was performed with CFD techniques. The boundary layer grid was generated by projecting the wall grid normally and fine grid was placed behind the trailing edge to capture the wake accurately. The distance to the far boundary is 100 chords and the flow condition is same as the wind tunnel test condition. Transition SST and DES turbulence models were utilized for accurate prediction of the transiton point. The predicted lift is higher but the drag is predicted lower than the wind tunnel test. 3-dimensional results with airfoil models of which aspect ratio were 2 and 5 were compared with 2-dimensional results.

Store Separation Analysis of a Fighter Aircraft's External Fuel Tank

  • Cho, Hwan-Kee;Kang, Chi-Hang;Jang, Young-Il;Lee, Sang-Hyun;Kim, Kwang-Yeon
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.11 no.4
    • /
    • pp.345-350
    • /
    • 2010
  • The repetitive vibrating action of an aerodynamic load causes an external fuel tank's horizontal fin to experience a shorter life cycle than its originally predicted one. Store separation analysis is needed to redesign the fin of an external fuel tank. In this research, free-drop tests were conducted using 15% scaled models in a subsonic wind tunnel in order to analyze the store separation characteristics of an external fuel tank. The store separation trajectory based on grid tests was also obtained to verify the results of the free-drop tests. The results acquired from the free-drop tests correlated well with the grid tests in regards to the trajectories and behavior of the stores separated from the aircraft. This agreement was especially noted in the early stages of the store separation.

An Efficient AMI Simulator Design adapted in Smart Grid (스마트그리드에서의 효율적인 AMI 구현을 위한 통합 시뮬레이터 설계)

  • Yang, Il-Kwon;Choi, Seung-Hwan;Lee, Sang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1368-1375
    • /
    • 2013
  • The Smart Grid, which can monitor or diagnose the power grid in real time to operate efficiently, has been pushed ahead systematically as one of alternatives to solve these issues by combining the advanced Information Communication Technology and the electrical network. Hence, the electric company which introduces smart grid technology can read remotely the electrical meter readings by means of two-way communication between the meter and the central system. This enabled the customer and the utility to take part in reasonable electrical energy utilization. AMI became one of the core foundations in realizing the Smart Grid. It is hard to test the entire process of AMI system before the full deployment because it covers the broad objects from the customer to the utility operation system and requires mass data handling and management. Therefore, we design an efficient AMI network model and a simulator for performance evaluation required to simulate the network model similar to the real environment. This tool supports to evaluate the efficiency of the AMI network equipments and deployment. Additionally, it estimates the appropriate number of deployments and the proper capabilities.

Analysis of optimum grid determination of water quality model with 3-D hydrodynamic model using environmental fluid dynamics code (EFDC)

  • Yin, Zhenhao;Seo, Dongil
    • Environmental Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.171-179
    • /
    • 2016
  • This study analyzes guidelines to select optimum number of grids to represent behavior of a given water system appropriately. The EFDC model was chosen as a 3-D hydrodynamic and water quality model and salt was chosen as a surrogate variable of pollutant. The model is applied to an artificial canal that receives salt water from coastal area and fresh water from a river from respective gate according to previously developed gate operation rule. Grids are subdivided in vertical and horizontal (longitudinal) directions, respectively until no significant changes are found in salinity concentrations. The optimum grid size was determined by comparing errors in average salt concentrations between a test grid systems against the most complicated grid system. MSE (mean squared error) and MAE (mean absolute error) are used to compare errors. The CFL (Courant-Friedrichs-Lewy) number was used to determine the optimum number of grid systems for the study site though it can be used when explicit numerical method is applied only. This study suggests errors seem acceptable when both MSE and MAE are less than unity approximately.