• Title/Summary/Keyword: Grid emission

Search Result 116, Processing Time 0.033 seconds

Feasibility Study for the Location of Air Quality Monitoring Network in Daegu Area (대구지역 대기오염자동측정망 위치의 타당성 분석)

  • Choi, Sung-Woo;Lee, Jung-Beom
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.81-91
    • /
    • 2011
  • Air quality monitoring networks are very important facilities to manage urban air pollution control and to set up an environmental policy. Since air quality monitoring network of Daegu was allocated from 1980s to mid-90s, there is need to reevaluate it and relocated its site. This study was evaluated the position of Daegu air quality monitoring station by unit environmental sensitivity index, grid emission rate, CAI (Comprehensive Air-quality Index) point. The investigation domain covered an area of 16 $\times$ 24 km centered at the metropolitan area of Daegu with grid spacing of 2 km. The location of alternative air quality monitoring networks was selected through optimization and quintiles analysis of total score. The result showed that all things considered, new air quality monitoring network need to install grid numbers 10, 28, 36, 37, 46. We also recommand three scenarios of alternative air quality monitoring network when considering unit environmental sensitivity index, emission rate and CAI point.

The Effects of NOx Emission Reductions from Power Plants over the Eastern United States

  • Ghim, Young-Sung;Chang, Young-Soo;David G. Streets
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.E
    • /
    • pp.45-54
    • /
    • 1999
  • The effectiveness of NOx emission reductions from power plants to alleviate persistent ozone nonattainment in the esterm Unites States was investigated with a focus on the Northeast Corridor, centered on New York City. The 1995 ozone episode along with the 2007 base case emission scenario was used with the Variable-Grid Urban Airshed Model(UAM-V) to determine ozone concentrations. Several scenarios based on EPA's proposal issued on October 10, 1997 were examined. Although it is widely recognized that the eastern United States includes a large Nox-sensitive region(e.g., Sillman, 1999), the study revealed that reducing NOx emissions from power plants beyond 500 miles (800km) was not effective for reducing ozone exceedances in the region. It was also found that NOx emissions from power plants play an important role in local ozone exceedances.

  • PDF

Comparison of Various Methods to Mitigate the Flicker Level of DFIG in Considering the Effect of Grid Conditions

  • Kim, Yun-Seong;Marathe, Aditya;Won, Dong-Jun
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.612-622
    • /
    • 2009
  • The short circuit ratio (SCR) of a given grid is able to show the stability of the system in the case of unwanted elements, such as wind turbulence. This paper presents the simulation of a model of the doubly fed induction generator in the simulation software PSCAD/EMTDC. This model has been used to study flicker during continuous operation and the effect of SCR and grid impedance angle on flicker emission. Simulation results show that compensation of the stator reactive power is an effective method to considerably reduce the flicker levels, irrespective of the grid conditions.

The Economic Evaluation of Renewable Energy Penetration Based on Grid Parity According to the Ratio of DC Power Supply (Grid Parity를 고려한 DC 전원 공급율에 따른 신재생에너지 계통 연계의 경제성 평가)

  • Kim, Sung-Yul;Lee, Sung-Hun;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.16-21
    • /
    • 2012
  • The growth in IT industry has brought a corresponding rise in the number of connected digital devices in the distribution network. These digital loads lead to AC to DC conversion losses in order to supply power to them. The more the renewable energies and plug-in electrical vehicles penetrated our lives, the more the electrical losses are caused by AC to DC conversion process. Hence, this paper suggests the methodology for evaluating the amount of power supplied according to the ratio of DC power supply and performs an economic analysis of DC distribution system considering grid parity. In here, the cost of carbon emission reduced by renewable energy is also concerned.

Selection of Priority Monitoring Areas for Hazardous Air Pollutants (HAPs) in Seoul using Geographic Information System (지리정보시스템을 활용한 서울시 유해대기오염물질 우선순위 측정지역 선정)

  • Kim, Seong-Joon;Park, Hyeon-Jin;Lee, Sang-Jin;Kim, Chang-Hyeok;Lee, Seung-Bok;Choi, Sung-Deuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.223-232
    • /
    • 2018
  • As the Seoul metropolitan city has the largest numbers of population and vehicles, the citizens can be exposed to hazardous air pollutants(HAPs) mainly from the vehicular exhaust and human activities. In this study, we proposed a systematic method for the selection of priority monitoring areas for HAPs using Geographic Information System (GIS). First, emission parameters(emission data, vehicle registration, monitoring data, and so on) and population parameters (population and population density) were plotted using the inverse distance weighted (IDW) interpolation. Then, the interpolation data for individual parameters, which were normalized between 1 and 5 points, were compiled for 270 grids with a resolution of $2km{\times}2km$. The total score of each grid was calculated using weights(1~5) for the individual parameters. The final ranking of each grid was assigned by four scenarios with varying fractions of the emission and population parameters from 50 : 50 to 80 : 20. Consequently, nine grids were suggested as priority monitoring areas, and all of them are located in the southwestern part of Seoul.

Development of Hybrid (Sb/Ca) Flooded Lead-Acid Battery for Minimizing Water Loss (감액 특성 향상을 위한 하이브리드(Sb/Ca) 액식 연축전지 개발)

  • Song, Seung Yun;Lim, Tae Seop;Kim, Sung Jun;Jung, Yeon-Gil;Yang, SeungCheol
    • Korean Journal of Materials Research
    • /
    • v.32 no.3
    • /
    • pp.146-152
    • /
    • 2022
  • One disadvantage of deep cycle flooded lead-acid batteries is increasing water loss caused by use of (+) Pb-Sb / (-) Pb-Sb alloy grid. Water loss is generated by the emission of hydrogen gas from the (-) electrode during battery charging. In this paper, we maintain cycle life aspect through the development of hybrid flooded lead-acid batteries to which a (+) Pb-Sb / (-) Pb-Ca grid is applied and deal with the improvement of water loss. The amount of water loss compared to that of the (-) Pb-Sb grid decreased when Ca was added to the (-) Pb grid. For the (-) Pb-Ca grid, it was confirmed that the time to reach 0.0 V, at which water decomposition occurs, was increased compared to that of the (-) Pb-Sb grid at the NPV (Negative Potential Voltage). In the cycle life test conducted with the BCI (Battery Council International) standard, compared to the (+) Pb-Ca grid, the (+) Pb-Sb grid increased the life cycle of the batteries and the (+) Pb-Ca grid showed an early end of life due to PbO corrosion layer generation, as determined through SEM / EDS and Tear Down analysis. In conclusion, by addition of Sb to (+) Pb grid and Ca to (-) Pb grid, we developed a hybrid flooded lead-acid battery that meets user requirements to improve water loss characteristics and preserve cycle life characteristics.

Experimental for Performance of electron 9un cathode electrode (Y-824) characteristics (전자총 캐소드전극(Y-824)의 특성실험)

  • Son, Y.G.;Kwon, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1552-1553
    • /
    • 2006
  • A thermionic gun of injector linac for pohang accelerator laboratory is required to generate beam pulse width less than 1 nsec. The gun uses cathode-grid assembly(EIMAC Y824) and operates up to 80 kV anode voltage. In order research characteristics of the electron gun, emission current from gun wear measured by the wall current monitor. In this paper the pulser system and characteristics of the emission current in region from 30 mA to 15 A are described.

  • PDF

Thermal and Electrical Energy Mix Optimization(EMO) Method for Real Large-scaled Residential Town Plan

  • Kang, Cha-Nyeong;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.513-520
    • /
    • 2018
  • Since Paris Climate Change Conference in 2015, many policies to reduce the emission of greenhouse gas have been accelerating, which are mainly related to renewable energy resources and micro-grid. Presently, the technology development and demonstration projects are mostly focused on diversifying the power resources by adding wind turbine, photo-voltaic and battery storage system in the island-type small micro-grid. It is expected that the large-scaled micro-grid projects based on the regional district and town/complex city, e.g. the block type micro-grid project in Daegu national industrial complex will proceed in the near future. In this case, the economic cost or the carbon emission can be optimized by the efficient operation of energy mix and the appropriate construction of electric and heat supplying facilities such as cogeneration, renewable energy resources, BESS, thermal storage and the existing heat and electricity supplying networks. However, when planning a large residential town or city, the concrete plan of the energy infrastructure has not been established until the construction plan stage and provided by the individual energy suppliers of water, heat, electricity and gas. So, it is difficult to build the efficient energy portfolio considering the characteristics of town or city. This paper introduces an energy mix optimization(EMO) method to determine the optimal capacity of thermal and electric resources which can be applied in the design stage of the real large-scaled residential town or city, and examines the feasibility of the proposed method by applying the real heat and electricity demand data of large-scale residential towns with thousands of households and by comparing the result of HOMER simulation developed by National Renewable Energy Laboratory(NREL).

Considerations in Space Allocation Methods of Emission from Area and Mobile Sources (면/이동오염원 배출량 공간 할당방식에 대한 고찰)

  • Kim, Hyun-Goo
    • Journal of Environmental Science International
    • /
    • v.11 no.7
    • /
    • pp.697-703
    • /
    • 2002
  • In the present study, space allocation methods of pollutant emission from area and mobile sources are assessed by the actual application to air quality modeling of Pohang area. It is found that the TM-based modeling which allocates emission onto the 1km x 1km sized TM-grid system predicts almost the same mean ground-level concentration as that by the GIS-based modeling which uses geographical information of area and mobile sources directly, while maximum ground-level concentration by the TM-based modeling is predicted considerably lower than that by the GIS-based modeling. Moreover, the problem is found that the TM-based modeling causes deviation of mobile roads. In conclusion, it is anticipated to applying GIS-based modeling for a more accurate assessment of air quality in local scale.

A Study on the Estimation of BVOCs Emission in Jeju Island (1) (제주지역 BVOCs의 배출량 산정에 관한 연구(1))

  • Lee, Ki-Ho;Kim, Hyeong-Cheol;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.2057-2069
    • /
    • 2014
  • This study was carried out to estimate the BVOCs emissions with the emission factors which reflected the native conditions of forests in Jeju Island. This study made effective use of the previous data for the weather data and the emission rate of each organic volatile component measured at 10 species of conifers and broad leaved trees. The CORINAIR method and the grid system of $1km{\times}1km$ for whole area of Jeju Island were adopted in calculating the BVOCs emission emitted from forest. The vegetation information for Jeju Island was referred to GIS and a government report. By the results of BVOCs emission for Jeju Island, the 85% of monoterpene emission was emitted from conifers and the others was from broad leaved trees. Most of monoterpene emission was attributed to Pinus thunbergii and Cryptomeria japonica. The broad leaved trees greatly contributed to the isoprene emission and Quercus serrata played a dominant role in emission of isoprene. The total amount of BVOCs emission was estimated as $3612ton\;yr^{-1}$ in Jeju Island. The 51.1% of total emission was contributed to conifers, the 44.9% to broad leaved trees, and the 4.0% to grassland. Of total emission of BVOCs, monoterpene accounted for 32.3%, isoprene for 28.0%, and OVOCs for 39.7%. The BVOCs emission estimated by this study was less than that estimated by other previous study. This means that it is important to survey the emission rate at native conditions and gather the detailed information for various species of vegetation on target region.