• 제목/요약/키워드: Grid connected-inverter

검색결과 503건 처리시간 0.026초

Droop Control Scheme of a Three-phase Inverter for Grid Voltage Unbalance Compensation

  • Liu, Hongpeng;Zhou, Jiajie;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1245-1254
    • /
    • 2018
  • The stability of a grid-connected system (GCS) has become a critical issue with the increasing utilization of renewable energy sources. Under grid faults, however, a grid-connected inverter cannot work efficiently by using only the traditional droop control. In addition, the unbalance factor of voltage/current at the common coupling point (PCC) may increase significantly. To ensure the stable operation of a GCS under grid faults, the capability to compensate for grid imbalance should be integrated. To solve the aforementioned problem, an improved voltage-type grid-connected control strategy is proposed in this study. A negative sequence conductance compensation loop based on a positive sequence power droop control is added to maintain PCC voltage balance and reduce grid current imbalance, thereby meeting PCC power quality requirements. Moreover, a stable analysis is presented based on the small signal model. Simulation and experimental results verify the aforementioned expectations, and consequently, the effectiveness of the proposed control scheme.

Z-소스 인버터를 사용한 단상 계통 연계형 태양광 시스템 제어 (Control of Single-Phase Grid-Connected Photovoltaic System using a Z-Source Inverter)

  • 전태원;트란콴빈;김흥근
    • 전력전자학회논문지
    • /
    • 제13권5호
    • /
    • pp.369-375
    • /
    • 2008
  • 본 논문에서는 Z-소스 인버터를 사용하여 단상 계통 연계형 태양광 시스템을 제어하는 기법을 제시하였다. 인버터 스위칭소자의 전압 스트레스를 고려하여 광전지 출력전압에 대한 계통 연계형 Z-소스 인버터의 동작영역을 분석하였다. 스위칭 손실을 감소시키면서 shoot-through 시간을 효율적으로 제어하는 스위칭 패턴을 사용하였다. 시뮬레이션 및 32-비트 DSP를 사용한 실험을 통하여 계통연계형 Z-소스 인버터의 제어 시스템의 성능을 평가하였다.

Analysis and Design of LCL Filter with Passive Damping Circuits for Three-phase Grid-connected Inverters

  • Ahn, Hyo Min;Oh, Chang-Yeol;Sung, Won-Yong;Ahn, Jung-Hoon;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.217-224
    • /
    • 2017
  • The analysis and design process of the LCL filter with passive damping circuits for three-phase grid-connected inverter are presented based on the generalized model of LCL filter. Several types of the passive damping circuits in previous studies could be compared and analyzed by using the generalized model considering various design criteria of passive damping circuits. According to the analysis in this paper, a reasonable configuration of passive damping circuits for three-phase grid-connected inverters is proposed. The validity of the proposed design process is verified by informative simulation and experimental results.

PWM 방식에 따른 계통연계 양방향 인버터의 손실양상 비교 및 분석 (Loss Analysis and Comparison of Grid-connected Bidirectional Inverter with Different Types of PWM Schemes)

  • 허성준;안효민;변종은;이병국
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.547-550
    • /
    • 2017
  • This paper presents a loss analysis and compares three pulse width modulation (PWM) methods applied in a three-phase grid-connected bidirectional inverter for an energy storage system. The losses in switching devices and output low pass filters are theoretically analyzed by using PWM control techniques. Grid-connected bidirectional inverters are designed by using PWM techniques, and the designed inverters are simulated to verify the analysis results.

간접전류제어방식 병렬형 계통연계 인버터의 무순단 모드절환 (Seamless Mode Transfer of Indirect Current Controlled Parallel Grid-Connected Inverters)

  • 송인종;최준수;임경배;최재호
    • 전력전자학회논문지
    • /
    • 제24권5호
    • /
    • pp.334-341
    • /
    • 2019
  • This study proposes the control strategy for the seamless mode transfer of indirect current controlled parallel grid-connected inverters. Under the abnormal grid condition, the grid-connected inverter can convert the operation mode from grid-connected to stand-alone mode to supply power to the local load. For a seamless mode transfer, the time delay problems caused by the accumulated control variable error must be solved, and the indirect current control method has been applied as one of the solutions. In this study, the design of control parameters for the proportional-resonant-based triple-loop indirect current controller and the control strategy for the seamless mode transfer of parallel grid-connected inverters are described and analyzed. The validity of the proposed mode transfer method is verified by the PSiM simulation results.

반도체 변압기용 단상 계통 연계형 인버터의 소신호 모델링과 제어기 설계 (Small-Signal Modeling and Controller Design of Grid-Connected Inverter for Solid State Transformer)

  • 김보경;이준영;;정지훈
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.40-47
    • /
    • 2017
  • In this paper, a small signal model for grid-connected inverter with unipolar pulse width modulation method is presented. Small-signal analysis allows to predict the stability and dynamics of the inverter. To regulate output voltage and to achieve power factor correction, inverter has two control loops. Loop gains are useful to identify the stability for multi-loop controlled system. Based on small-signal model, controllers are designed to improve audio susceptibility and output impedance characteristics. Proposed small-signal model and controllers are verified by PSIM simulation and experiments.

디지털 PI 컨트롤을 사용한 단상 7레벨 연계형 인버터 (Single-Phase Seven-Level Grid-Connected Inverter Employing Digital PI Controller)

  • 레동부;최우석;박진욱;박성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.441-442
    • /
    • 2015
  • This paper proposes a new single-phase seven-level grid-connected inverter. Operational principle with switching function are analyzed. A digital proportional-integral current-control algorithm was implemented in a TMS320F28335 DSP to keep the current injected into the grid sinusoidal. To verify the performance of the proposed inverter, PSIM simulation and experimental results are also shown in this paper.

  • PDF

전원 전압 불평형시 계통연계형 인버터의 유효전력 리플 억제를 위한 듀얼 전류제어기 구현과 출력 전력의 실시간 제한 알고리즘 (Implementation of Dual Current Controller and Realtime Power Limiting Algorithm in Grid-connected Inverter during Unbalanced Voltage Conditions)

  • 송승호;김정재
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.54-60
    • /
    • 2006
  • A power limiting algorithm is proposed for stable operation of grid-connected inverter in case of grid voltage unbalance considering the operation limit of inverter. During the voltage unbalance the control performance of Inverter. is degraded and the output power contains 120Hz ripple due to the negative sequence of voltage. In this paper, conventional dual sequence current controller is implemented to solve these problems using separated control of positive and negative sequence. Especially the maximum power limit which guarantees the maximum rated current of the inverter is automatically calculated as the instant grid voltage changes. As soon as the voltage recovers the proposed algorithm can return to the normal power control mode accomplishing low voltage ride through. Proposed algorithm is verifed using PSCAD/EMTDC simulations and tested experimentally at 4.4kW wind turbine simulator set-up.

A Dual Buck Three-Level PV Grid-Connected Inverter

  • Ji, Baojian;Hong, Feng;Wang, Jianhua;Huang, Shengming
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.910-919
    • /
    • 2015
  • The use of a PV grid-connected inverter with non-isolated topology and without a transformer is good for improving conversion efficiency; however, this inverter has become increasingly complicated for eliminating leakage current. To simplify the complicated architecture of traditional three-level dual buck inverters, a new dual Buck three-level PV grid-connected inverter topology is proposed. In the proposed topology, the voltage on the grounding stray capacitor is clamped by large input capacitors and is equal to half of the bus voltage; thus, leakage current can be eliminated. Unlike in the traditional topology, the current in the proposed topology passes through few elements and does not flow through the body diodes of MOSFET switches, resulting in increased efficiency. Additionally, a multi-loop control method that includes voltage-balancing control is proposed and analyzed. Both simulation and experimental results are demonstrated to verify the proposed structure and control method.

Power Quality Improvement for Grid Connected Inverters under Distorted and Unbalanced Grids

  • Kim, Hyun-Sou;Kim, Jung-Su;Kim, Kyeong-Hwa
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1578-1586
    • /
    • 2016
  • A power quality improvement scheme for grid connected inverters, even in the presence of the disturbances in grid voltages due to harmonic distortions and three-phase imbalance, is presented for distributed generation (DG) power systems. The control objective is to force the inverter currents to follow their references with robustness even under external disturbances in grid voltages. The proposed scheme is realized by a disturbance observer (DOB) based current control scheme. Since the uncertainty in a system can be effectively canceled out using an estimated disturbance by the DOB, the resultant system behaves like a closed-loop system consisting of a disturbance-free nominal model. For experimental verification, a 2 kVA laboratory prototype of a grid connected inverter has been built using a digital signal processor (DSP) TMS320F28335. Through comparative simulations and experimental results under grid disturbances such as harmonic distortion and imbalance, the effectiveness of the proposed DOB based current control scheme is demonstrated.