• Title/Summary/Keyword: Grid Plan

Search Result 198, Processing Time 0.029 seconds

Target dose study of effects of changes in the AAA Calculation resolution on Lung SABR plan (Lung SABR plan시 AAA의 Calculation resolution 변화에 의한 Target dose 영향 연구)

  • Kim, Dae Il;Son, Sang Jun;Ahn, Bum Seok;Jung, Chi Hoon;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.171-176
    • /
    • 2014
  • Purpose : Changing the calculation grid of AAA in Lung SABR plan and to analyze the changes in target dose, and investigated the effects associated with it, and considered a suitable method of application. Materials and Methods : 4D CT image that was used to plan all been taken with Brilliance Big Bore CT (Philips, Netherlands) and in Lung SABR plan($Eclipse^{TM}$ ver10.0.42, Varian, the USA), use anisotropic analytic algorithm(AAA, ver.10, Varian Medical Systems, Palo Alto, CA, USA) and, was calculated by the calculation grid 1.0, 3.0, 5.0 mm in each Lung SABR plan. Results : Lung SABR plan of 10 cases are using each of 1.0 mm, 3.0 mm, 5.0 mm calculation grid, and in case of use a 1.0 mm calculation grid $V_{98}$. of the prescribed dose is about $99.5%{\pm}1.5%$, $D_{min}$ of the prescribed dose is about $92.5{\pm}1.5%$ and Homogeneity Index(HI) is $1.0489{\pm}0.0025$. In the case of use a 3.0 mm calculation grid $V_{98}$ dose of the prescribed dose is about $90{\pm}4.5%$, $D_{min}$ of the prescribed dose is about $87.5{\pm}3%$ and HI is about $1.07{\pm}1$. In the case of use a 5.0 mm calculation grid $V_{98}$ dose of the prescribed dose is about $63{\pm}15%$, $D_{min}$ of the prescribed dose is about $83{\pm}4%$ and HI is about $1.13{\pm}0.2$, respectively. Conclusion : The calculation grid of 1.0 mm is better improves the accuracy of dose calculation than using 3.0 mm and 5.0 mm, although calculation times increase in the case of smaller PTV relatively. As lung, spread relatively large and low density and small PTV, it is considered and good to use a calculation grid of 1.0 mm.

A Study on Urban form of Jinhae Radial-Grid Planning (진해 시가지의 방사-격자 도시 형태에 관한 연구)

  • Shin, Gunsoo
    • Journal of architectural history
    • /
    • v.33 no.1
    • /
    • pp.19-31
    • /
    • 2024
  • Jinhae is the oldest Western-style radial and grid city on the Korean Peninsula, and it also has the most defined structure to date, remaining largely unchanged and unlike any other in Korea. The Jinhae town plan was completed immediately after the signing of the Japan-Korea Treaty. Although the city of Jinhae was built by the Japanese, its overall organizational principle is clearly a radial-grid form that was established in the West. The Jinhae radial-grid planning was elaborately constructed with multiple layers of overlapping structures. It is the result of the application of geometry that creates symmetry and hierarchy in European countries, and the simultaneous consideration of road hierarchy and land form in the process of combining radial and grid forms. To reveal these points, four analyses are performed. First, the formation process of Western radial and grid streets is reviewed and compared to derive review points for Jinhae City. Second, the layout and geometric characteristics of radial streets are discussed. Third, the hierarchical characteristics and connections of grid streets are analyzed. The last part is a comparative analysis of the plan and the final realization.

A Study on the Layout Patterns of Public Schools in Manhattan - Focused on Relationship between Manhattan Grid Plan and Open Space - (뉴욕시 공립학교에 나타난 배치 특성에 관한 연구 - 맨하튼 가로체계와 외부공간의 관계를 중심으로 -)

  • Kim, Pil-Soo;Jeon, You-Chang
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.20 no.2
    • /
    • pp.3-14
    • /
    • 2013
  • The purpose of this study is to analyze patterns of public school building layout types, open space and relationship with communities in the Manhattan grid plan. The study illustrates how building layout patterns of school facilities are influenced by societal demands in the urban grid environment. During the nineteenth century, the Island of Manhattan was transformed into a physical representation of the Cartesian coordinate system via the development of the grid street plan. In order to take advantage of streets as urban space, it is quite important to understand characteristics of communities and open space relationships between buildings and streets. Moreover, the strategic planning of schools' outdoor space vitalizes public streets as a critical community anchor. This research reviews 118 Manhattan public schools and categorizes them by (1) building layout type, (2) site type, (3) circulation and public open space, which are the biggest factors that determine the layout patterns of the public schools in Manhattan. As a result of analysis, the layout patterns are classified into seven types : "ㅡ", "L", "ㄷ", "ㅁ", "H", "T" and "other" type. Of these, "ㅡ" type and "L" type occur most frequently, because these configurations most flexibly fit into the limited grid-locked blocks, the various types of site & topography, and adapt most dynamically to the open spaces created by using avenues and streets. The ultimate objective of this study is to provide a case study for future efforts to plan open spaces for campuses that effectively utilize the streets in proximity.

A Study on electric facilities plan and application of low-voltage grid connection for a photovoltaic electric power station (태양광 발전소의 전기설비 설계 및 저압 계통연계 적용사례에 관한 연구)

  • Lim, Kyung-Mi;Kim, Kyeong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.305-308
    • /
    • 2009
  • This paper resents a study on the electric facilities plan and application of low-voltage grid connection for a photovoltaic electric power station. The analysis for an installation cost is carried out and a new plan to solve the problem caused by a voltage drop in a low-voltage grid connection is devised. It is expected that the results can be usefully applied to spread the photovoltaic electric power station.

  • PDF

The Effects of Penetration of the Electric Vehicles on the Electric Power Grid in the Jeju Island (제주도에서 전기자동차 보급이 전력계통에 미치는 영향)

  • Oh, Seong-Bo;Lee, Gae-Myoung;Hwang, Choong-Gu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • The Jeju Special Self-Government Provincial Government has made the plan penetrating gradually electric vehicles(EVs) in the Jeju Special Self-Government Province(Jejudo). However the effects of EVs penetration on the electrical grid of the Jejudo is not reported. In this paper the yearly electric energy consumed by the EVs was calculated and the effects of the EV penetration on the peak power of the grid were analyzed in the Jejudo for the future 10 years, and we hope that our study results will help the governors realize the EVs penetration plan in the Jejudo. The calculation results show that the rate of the electric energy used by the EVs will become to 2.9% at its maximum at the 2017 year when the penetration rate of EVs in passenger cars becomes 10%, and the rate of the electric energy consumed by the EVs will become to 9.4% at its maximum at the 2020 year when the penetration rate of EVs in passenger cars becomes 30%. The concepts of smart-charging capacity and 100%-valley-filling charging capacity of the grid were defined and calculated for the Jeju Grid, and the grid was analyzed to have the sufficient EV charging capacity until the 2022 year.

Development Plan of Grid System Utilizing Spatial Information (공간정보를 활용한 격자체계 개선방안)

  • Kim, Dae Hyun;Kim, Jae Myeong;Yoon, Byung Chan;Chang, Eun Mi;Choi, Yun Soo
    • Spatial Information Research
    • /
    • v.23 no.6
    • /
    • pp.43-55
    • /
    • 2015
  • Currently, each organization has developed its gridded data in the form of respective grid system for its own purpose. Interoperability among the organization had been limited and resulted in inconvenient data access and application across domains. In this study, we investigated potential standards for National grid system and their strength and weakness. We also reviewed existing gridding schemes and had a survey of demand about grid system to those who have used or would plan to use gridded data in academic and business sectors. As the result of survey of demand, we suggested national grid system for national grid data integration management system which has the mutual compatibility and also proposed sharing scheme of the grid type for users who need to grid data.

Basic Plan of National Grid and Domestic and International Research Tendency (국가 Grid 기본 계획과 국$\cdot$내외 Grid 프로젝트 추진 동향)

  • Jang Haeng Jin;Park Hyoung Woo;Lee Sangsan
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.164-173
    • /
    • 2001
  • Advanced countries centered by National Supercomputing Center are inclined to construct Grid Infra and develop key applications in high performance computing field. They are also trying to globalize the Grid project aided by research groups in nations and continents. Computing technology and application development in Grid computing environment become indirect capital of high performance computing and information technology. Therefore, Korean government would like to participate in their Grid construction and application development actively and pursue to Grid project to develop Grid industries such as IT, BT. next five years.

  • PDF

Thermal and Electrical Energy Mix Optimization(EMO) Method for Real Large-scaled Residential Town Plan

  • Kang, Cha-Nyeong;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.513-520
    • /
    • 2018
  • Since Paris Climate Change Conference in 2015, many policies to reduce the emission of greenhouse gas have been accelerating, which are mainly related to renewable energy resources and micro-grid. Presently, the technology development and demonstration projects are mostly focused on diversifying the power resources by adding wind turbine, photo-voltaic and battery storage system in the island-type small micro-grid. It is expected that the large-scaled micro-grid projects based on the regional district and town/complex city, e.g. the block type micro-grid project in Daegu national industrial complex will proceed in the near future. In this case, the economic cost or the carbon emission can be optimized by the efficient operation of energy mix and the appropriate construction of electric and heat supplying facilities such as cogeneration, renewable energy resources, BESS, thermal storage and the existing heat and electricity supplying networks. However, when planning a large residential town or city, the concrete plan of the energy infrastructure has not been established until the construction plan stage and provided by the individual energy suppliers of water, heat, electricity and gas. So, it is difficult to build the efficient energy portfolio considering the characteristics of town or city. This paper introduces an energy mix optimization(EMO) method to determine the optimal capacity of thermal and electric resources which can be applied in the design stage of the real large-scaled residential town or city, and examines the feasibility of the proposed method by applying the real heat and electricity demand data of large-scale residential towns with thousands of households and by comparing the result of HOMER simulation developed by National Renewable Energy Laboratory(NREL).

A sensitivity analysis about reactive power according to the interconnection distance of wave-offshore hybrid generation system (복합발전 계통연계 시 보상장치 필요성 분석을 위한 거리에 따른 무효전력 민감성 분석)

  • Jung, Seungmin;Yoo, Yeuntae;Song, Sungyoon;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.251-252
    • /
    • 2015
  • The designed hybrid generation system (HGS) not only consider the voltage condition of grid connection point but also do reactive power support according to the transmission system operator's directions. The PCS operation plan in HGS should be supported by precise transferred quantity expectation about reactive power because the system has large physical areas and also be interconnected with grid through long transmission system. Therefore, the realistic measuring process about transferred reactive power quantity by utilizing HGS is required to consider additional compensation plan. In this paper, an reactive power transferred capability of HGS with expected parameter is analyzed, and imposed to the simulation process that is performed on EMTDC environment. Basically, grid information and system characteristics were utilized with Jeju island in Korea, and the performance analysis is carried out based on the composed layout in ongoing project.

  • PDF