• Title/Summary/Keyword: Grid Monitoring Architecture

Search Result 28, Processing Time 0.029 seconds

A Study on the GMA-based CIM Design for u-City Service Implementation (u-City 서비스 구현을 위한 GMA 기반의 CIM 설계에 관한 연구)

  • Ock, Young-Seok;Ahn, Chang-Won;Kim, Min-Soo
    • The Journal of Society for e-Business Studies
    • /
    • v.14 no.4
    • /
    • pp.287-297
    • /
    • 2009
  • Though the interest for the construction of ubiquitous city (u-City) has been increased in many researches, many of those efforts are still done somewhat separated ways such as from the perspective of architectural design of urban city or from the perspective of underlying ICT (Information and Communication Technology) implementation. Since there are various services and technical components involved in u-City implementation, those separated approaches can cause much troubles while implementing u-City. In addition to this, because u-City components are continually changing and expanding, to cope with this evolution, many researches about the infrastructure of u-City should be done in a systematic way while integrally considering various perspectives of u-City. In this research, by combining WBEM/CIM standards to GMA (Grid Monitoring Architecture), we could provide WBEM/CIM design that is usable for u-City implementation. In contrast to the conventional research that is still abstract, our study presents concrete and implementable u-City infrastructure model. We hope our result will be a valuable reference for the other u-City infrastructure-related researches.

  • PDF

The Economics Evaluation of Grid-connected Photovoltaic Systems in Residential Houses

  • Lee, Hyun-Seung;Kim, Sung-Bum;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.5-10
    • /
    • 2015
  • Purpose: To evaluate the economic performance of grid-connected photovoltaic system in residential house, household electricity bill policy of Korea Electric Power Corporation (KEPCO) must be applied precisely, and market tendency and uncertainty of system also need to be considered. In this study, to evaluate the economic feasibility of PV system, we measured PV power generation and electricity consumption of six of Green home in Daejeon through web based remote monitoring system. Method: We applied Monte-Carlo simulation based on life cycle cost analysis, to reflect an uncertainty of main factor in economic feasibility evaluation of photovoltaic system. Result: First, with deterministic analysis, the difference of NPV of cumulative financial savings among households varied from -3,310 ~ 24,170 thousand won, portraying notably big range. Also the possibility of getting the same result was 50% when applying uncertainty. Second, the higher electricity consumption is, the more economic feasibility of photovoltaic system increases because KEPCO uses progressive taxation in household electricity bill policy. Third, The contribution to variance of electricity price increases in NPV varied from 98.5% to 99.9%. While the inflation rate and annual degradation contributed very little to none.

An Application of GRID Architecture on a Part of Urban Facilities Management Based on U-GIS (U-GIS 기반 도시시설물 관리 분야의 그리드(GRID) 아키텍처 적용 연구)

  • Nam, Sang-Kwan;Oh, Yoon-Seuk;Ryu, Seung-Ki;Kwon, Hyuk-Jong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.4
    • /
    • pp.113-124
    • /
    • 2009
  • A research of grid computing that is the combination of computer resources from multiple distributed administrative domains to get large amount of computing power is underway. This research is an application of grid technology on a urban facilities management system based on u-GIS. The sensors are set up in the urban facilities to make it monitoring. If an amount of sensors and gateways is increased, the server needs more computing resources to process the data. In this study we developed the skills that can distribute jobs to idle gateway, in case of the server capacity had approached threshold. It will be possible to develop of economic and efficient system that will apply to large amount of data processing about u-City.

  • PDF

Twin models for high-resolution visual inspections

  • Seyedomid Sajedi;Kareem A. Eltouny;Xiao Liang
    • Smart Structures and Systems
    • /
    • v.31 no.4
    • /
    • pp.351-363
    • /
    • 2023
  • Visual structural inspections are an inseparable part of post-earthquake damage assessments. With unmanned aerial vehicles (UAVs) establishing a new frontier in visual inspections, there are major computational challenges in processing the collected massive amounts of high-resolution visual data. We propose twin deep learning models that can provide accurate high-resolution structural components and damage segmentation masks efficiently. The traditional approach to cope with high memory computational demands is to either uniformly downsample the raw images at the price of losing fine local details or cropping smaller parts of the images leading to a loss of global contextual information. Therefore, our twin models comprising Trainable Resizing for high-resolution Segmentation Network (TRS-Net) and DmgFormer approaches the global and local semantics from different perspectives. TRS-Net is a compound, high-resolution segmentation architecture equipped with learnable downsampler and upsampler modules to minimize information loss for optimal performance and efficiency. DmgFormer utilizes a transformer backbone and a convolutional decoder head with skip connections on a grid of crops aiming for high precision learning without downsizing. An augmented inference technique is used to boost performance further and reduce the possible loss of context due to grid cropping. Comprehensive experiments have been performed on the 3D physics-based graphics models (PBGMs) synthetic environments in the QuakeCity dataset. The proposed framework is evaluated using several metrics on three segmentation tasks: component type, component damage state, and global damage (crack, rebar, spalling). The models were developed as part of the 2nd International Competition for Structural Health Monitoring.

Numerical prediction analysis of propeller bearing force for full-scale hull-propeller-rudder system

  • Wang, Chao;Sun, Shuai;Li, Liang;Ye, Liyu
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.6
    • /
    • pp.589-601
    • /
    • 2016
  • The hybrid grid was adopted and numerical prediction analysis of propeller unsteady bearing force considering free surface was performed for mode and full-scale KCS hull-propeller-rudder system by employing RANS method and VOF model. In order to obtain the propeller velocity under self-propulsion point, firstly, the numerical simulation for self-propulsion test of full-scale ship is carried out. The results show that the scale effect of velocity at self-propulsion point and wake fraction is obvious. Then, the transient two-phase flow calculations are performed for model and full-scale KCS hull-propeller-rudder systems. According to the monitoring data, it is found that the propeller unsteady bearing force is fluctuating periodically over time and full-scale propeller's time-average value is smaller than model-scale's. The frequency spectrum curves are also provided after fast Fourier transform. By analyzing the frequency spectrum data, it is easy to summarize that each component of the propeller bearing force have the same fluctuation frequency and the peak in BFP is maximum. What's more, each component of full-scale bearing force's fluctuation value is bigger than model-scale's except the bending moment coefficient about the Y-axis.

Evaluation of wind loads and wind induced responses of a super-tall building by large eddy simulation

  • Lu, C.L.;Li, Q.S.;Huang, S.H.;Tuan, Alex Y.;Zhi, L.H.;Su, Sheng-chung
    • Wind and Structures
    • /
    • v.23 no.4
    • /
    • pp.313-350
    • /
    • 2016
  • Taipei 101 Tower, which has 101 stories with height of 508 m, is located in Taipei where typhoons and earthquakes commonly occur. It is currently the second tallest building in the world. Therefore, the dynamic performance of the super-tall building under strong wind actions requires particular attentions. In this study, Large Eddy Simulation (LES) integrated with a new inflow turbulence generator and a new sub-grid scale (SGS) model was conducted to simulate the wind loads on the super-tall building. Three-dimensional finite element model of Taipei 101 Tower was established and used to evaluate the wind-induced responses of the high-rise structure based on the simulated wind forces. The numerical results were found to be consistent with those measured from a vibration monitoring system installed in the building. Furthermore, the equivalent static wind loads on the building, which were computed by the time-domain and frequency-domain analysis, respectively, were in satisfactory agreement with available wind tunnel testing results. It has been demonstrated through the validation studies that the numerical framework presented in this paper, including the recommended SGS model, the inflow turbulence generation technique and associated numerical treatments, is a useful tool for evaluation of the wind loads and wind-induced responses of tall buildings.

Annual Energy Performance Evaluation of Zero Energy House Using Metering Data (실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가)

  • Lim, Hee-Won;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

International Standardization and Implementation of Home Energy Saving System for Smart Grid (스마트 그리드를 위한 홈 에너지 절감 시스템의 IEC 국제표준화 및 구현)

  • Choi, Kwang-Soon;Lee, Sang-Won;Park, Young-Choong;Jung, Kwang-Mo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.12
    • /
    • pp.1222-1229
    • /
    • 2012
  • For the reduction of electric energy consumption and its efficient use at homes or buildings, a new work item proposal for new architecture and functional requirements of Energy Saving System (ESS) was proposed to IEC TC 100 and accepted as a new project, IEC PT 62654 in 2009. Recently, the final ballot for publication passed without negative votes and IEC TS 62654 was finally published in August 2012. For the verification of this standard, Prototype of ESS system composed of an ESS server, ESS clients, and portable ESS terminal were especially implemented in parallel with the standardization. Electric Power Control and Management (EPCM) protocol for the communication between ESS server and clients was also implemented, which supports self-configuration of ESS network, power consumption monitoring, remote power control, and additional functions for intelligent energy saving services.