• 제목/요약/키워드: Grid Electrode

Search Result 97, Processing Time 0.174 seconds

A Study on the Improvement of the Efficiency of Dye-sensitized Solar Cell using the Laser Scribing and the Grid Electrode (레이저 식각 및 그리드 전극을 적용한 염료감응형 태양전지의 효율 향상 연구)

  • Seo, Hyun-Woong;Son, Min-Kyu;Lee, Kyung-Jun;Kim, Jeong-Hoon;Hong, Ji-Tae;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1802-1806
    • /
    • 2008
  • Dye-sensitized solar cell (DSC) based on some advantages such as transparency, cheap materials and anti-sensibility for an anlge of incidence has been expected to capture most of solar cell market in the near future. To practical use of DSC, researches on high efficiency as well as upscaling are necessary. In this study, we tried to insert the grid electrode in DSC and scribe transparent conducting oxide (TCO) using Nd:YAG laser. The grid electrode makes the electron movement improved and diffusional movement minimized. Consequently, the efficiency of DSC was increased by reducing electron loss and the surface resistance of TCO. The grid electrode was made using Ag target by radio frequency sputtering. And the scribed surface was confirmed by taking a scanning electron microscopy photos. As the result, grid cell had improved photocurrent and fill factor as compared with the conventional cell. And the efficiency was increased about 1% by enhanced photocurrent and fill factor.

Modelling on Sheath Expansion of Two-dimensional Grid Electrodes

  • Yi, Changho;Namkung, Won;Cho, Moohyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.243.1-243.1
    • /
    • 2014
  • For two-dimensional grid electrodes immersed in plasmas, sheath expansion due to negative high-voltage pulse applied to the electrode generates high-energy pseudowave. The high-energy pseudowave can be used as ion beam for ion implantation. To estimate ion dose due to high-energy pseudowave, investigation on sheath expansion of grid electroes is necessary. To investigate sheath expansion, an analytic model was developed by Vlasov equation and applying the 1-D sheath expansion model to 2-D. Because of lack of generalized 2-D Child-Langmuir current, model cannot give solvable equation. Instead, for a given grid electrode geometry, the model found the relations between ion distribution functions, Child-Langmuir currents, and sheath expansions. With these relations and particle-in-cell (PIC) simulations, for given grid electrode geometry, computation time was greatly reduced for various conditions such as electrode voltages, plasma densities, and ion species. The model was examined by PIC simulations and experiments, and they well agreed.

  • PDF

CFD Analysis of Gas Insulated Switchgear with Moving Grid (이동격자를 이용한 초고압 차단기 유동해석)

  • Min B. S.;Park I. S.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.737-738
    • /
    • 2002
  • To develop and improve a GIS(Gas Insulated Switchgear), the prediction of the pressure in puffer cylinder and the flow between the nozzle and the moving electrode within GIS is very important.The leading companies in GIS business issue the results of the study of flow within GIS including arc plasma. In this study, the characteristics of the flow of the GIS developed by HHI(Hyundai Heavy Industries Co. Ltd.) was investigated. To simulate the compressible flow of GIS, the CFX, a commercial CFD code, was used. With moving grid method, the movement of piston and electrode was simulated. The moving grid method was superior to the method of varying the property of cells to move an obsticle, in stability and convergencce of solution. The calculated maximum pressure within the puffer cylinder was matched with experimental data within $5{\%}$ error. The oscilation of pressure in GIS after the movement of electrode was well predicted.

  • PDF

Measurement of Grounding Impedances in Large-scale Grounding Electrode Systems (대형접지전극시스템 접지임피던스의 측정)

  • Lee, Kyoung-Hoon;Choi, Jong-Hyuk;Choi, Young-Chul;Lee, Kyu-Sun;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.193-196
    • /
    • 2008
  • In these days, large structures are constructed and bonded with ground grid Because the distances between mesh and auxiliary electrodes are not enough in downtown areas, it is very difficult to measure the ground resistance of large scale grounding electrode systems. Actually the auxiliary electrodes for test are installed in grounding grid. This paper present the experimental results of ground resistance and impedance according to the location of auxiliary electrode. As a result, we get much lower resistances and impedances than real values the auxiliary electrodes are placed in the ground grid. In case that the auxiliary electrodes are located in the ground grid the resistances are very low and reactance only is inductive component.

  • PDF

A study on the photoelectric characteristics as a result of changing grid gap (DSC(Dye-sensitized Solar Cell)의 Grid 간격 변화에 따른 광전특성 연구)

  • Seo, Hyun-Woong;Kim, Mi-Jeong;Choi, Jin-Young;Hong, Ji-Tae;Park, Sung-Jin;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.199-201
    • /
    • 2006
  • A lot of researches and experiments have been performed to make more efficient dye-sensitized solar cell. Among them, insertion of a grid electrode in DSC is one method to increase overall performance as being shortened distance of electrons' movement by diffusion. In this paper, we measured overall characteristics which is included voltage-current characteristic curve, efficiency, fill factor by comparison between DSC without and with grid electrode. As a result, we got maximum 1.8 times increase of efficiency and approximately 1.7 times rise of fill factor. And we experimented 8, 10, 12, 14mm of grid gap and compared their results to optimize grid gap which is able to incite the most effective movement of electrons. Consequently, we got the result that electrons' movement is the most effect ive when grid gap is approximately 12mm.

  • PDF

A study on Improvement of Electric charge storage characteristics using $Teflon^{(R)}FEP$ film ($Teflon^{(R)}FEP$ film을 사용한 전하보존특성 향상에 관한 연구)

  • Kim, Seong-Jun;Lee, Hyeon-Seok;Kwon, Jeong-Yeol;Kim, Ji-Kyun;Lee, Heon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.539-540
    • /
    • 2006
  • In this paper, We examine that characteristics of formative electret with polymer film and electric charge storage using grid corona discharge. compound polymer of fluorine resin used for material in electret because of high electric charge accumulation, excellent electrical and physical characteristic. All experiments were carried out with circular samples of $Teflon^(R)FEP$ film, 12.5[${\mu}m$] thick. As experiment variables, we used voltage, electrode thickness, discharge electrode gap, and discharge time. According to this variables, we studied on characteristics of formative electret and electric charge storage. Additionally we make a comparative study of the result between the grid corona discharge and needle electrode discharge.

  • PDF

Measurement and Analysis of Ground Impedance according to Arrangement of Auxiliary Probe around Ground Grid (접지 그리드에서의 보조전극 배치에 따른 접지임피던스 측정 및 분석)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.46-50
    • /
    • 2015
  • This paper describes the measurement and analysis of ground impedance according to arrangement of auxiliary probe around ground grid using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method involves passing a current between a ground electrode and a current probe, and then measuring the voltage between a ground electrode and a potential probe. To minimize interelectrode influences due to mutual resistances, the current probe is a generally placed at a substantial distance from the ground electrode under test. In order to analyze the effects of ground impedance due to the arrangement of auxiliary probe and frequency, ground impedances were measured in case that the arrangements of auxiliary probe were straight line, perpendicular line, and horizontal line. The distance of current probe was located from 10[m] to 200[m] and the measuring frequency was ranged from 55[Hz] to 513[Hz]. As a consequence, the ground impedance increases with increasing the distance from the ground electrode to the point to be tested, but the ground impedance decreases with increasing the frequency.

Improved Mesh Grounding Electrode Model by Changing Arrangements of Internal Conductors of the Mesh Grounding Electrode (메쉬접지극의 내부도체 배치에 따른 개선된 메쉬접지극 모델)

  • Shim, Yong-Sik;Choi, Hong-Kyoo;Kim, Tae-Hoon;Song, Young-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.60-66
    • /
    • 2010
  • Mesh grounding electrodes in Korea and abroad are designed as lattice-shaped equidistance grounding grids. In case of a lattice-shaped grounding Grid, however, there is a problem of higher touch voltage at the corner of the grid relative to the center. To overcome this problem, we used oblique-shaped equidistance grounding grid to reduce the area of the corner where mesh voltage occurs. As a result the mesh voltage was reduced. Therefore, this paper suggests the use of oblique-shaped grounding grid instead of the existing lattice-shaped ones. It applied the same grounding design dimensions for both lattice-shaped and oblique-shaped grounding grids, compared and analyzed mesh voltage, GPR, ground resistance, total length of grounding conductor, verified that oblique-shaped grounding grid is superior to the lattice-shaped.

Development of Hybrid (Sb/Ca) Flooded Lead-Acid Battery for Minimizing Water Loss (감액 특성 향상을 위한 하이브리드(Sb/Ca) 액식 연축전지 개발)

  • Song, Seung Yun;Lim, Tae Seop;Kim, Sung Jun;Jung, Yeon-Gil;Yang, SeungCheol
    • Korean Journal of Materials Research
    • /
    • v.32 no.3
    • /
    • pp.146-152
    • /
    • 2022
  • One disadvantage of deep cycle flooded lead-acid batteries is increasing water loss caused by use of (+) Pb-Sb / (-) Pb-Sb alloy grid. Water loss is generated by the emission of hydrogen gas from the (-) electrode during battery charging. In this paper, we maintain cycle life aspect through the development of hybrid flooded lead-acid batteries to which a (+) Pb-Sb / (-) Pb-Ca grid is applied and deal with the improvement of water loss. The amount of water loss compared to that of the (-) Pb-Sb grid decreased when Ca was added to the (-) Pb grid. For the (-) Pb-Ca grid, it was confirmed that the time to reach 0.0 V, at which water decomposition occurs, was increased compared to that of the (-) Pb-Sb grid at the NPV (Negative Potential Voltage). In the cycle life test conducted with the BCI (Battery Council International) standard, compared to the (+) Pb-Ca grid, the (+) Pb-Sb grid increased the life cycle of the batteries and the (+) Pb-Ca grid showed an early end of life due to PbO corrosion layer generation, as determined through SEM / EDS and Tear Down analysis. In conclusion, by addition of Sb to (+) Pb grid and Ca to (-) Pb grid, we developed a hybrid flooded lead-acid battery that meets user requirements to improve water loss characteristics and preserve cycle life characteristics.

Investigation of Large-scale Transmission Tower Grounding Grid with High Amplitude and Uniform Flowing Impulse Current

  • Yang, Shuai;Huang, Jiarui;Wei, Shaodong;Zhou, Wenjun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2050-2058
    • /
    • 2018
  • Impulse characteristic of transmission tower grounding grid is needed for lightning protection of transmission line. This paper describes an outdoor experimental test facility established for large-scale grounding grid of transmission tower, made up of four impulse current generators and a circle current return electrode. The amplitude of impulse current is up to 100 kA. The results of the CDEGS simulation and GPR measurement reveal the uniform current distribution in the test arrangement. An impulse test for a square electrode with extended conductors is carried out in condition of three current waveforms with different amplitude. Based on the electrical network model and iterative algorithm method, a calculation model is proposed to simulate the impulse characteristic of large-scale grounding grid considering soil ionization. The curve of impulse resistance against the current amplitude shows the soil ionization both from the simulation and test. Deviation between the simulation and test result is less than 15%.