• Title/Summary/Keyword: Greenhouse Structure

Search Result 218, Processing Time 0.024 seconds

Estimation and Feature of Greenhouse Gas Emission in Building Sector by National Energy Statistic (국가 에너지통계에 따른 건물부문 온실가스 배출량 추계 및 특성)

  • Jeong, Young-Sun;Kim, Tae-Hyoung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.7
    • /
    • pp.187-195
    • /
    • 2019
  • In December 2015, The Paris Agreement was adopted to undertake ambitious efforts to combat climate change. Korean government announced its goal of reducing the country's greenhouse gas emissions by up to 37% below business as usual projections by 2030 in 2015. The purpose of this study was to set up the calculation methodology of GHG emission($CO_{2e}$) in building sector and to estimate the annual GHG emission in building sector based on national energy consumption statistic. The GHG emission from buildings is about 135.8 million ton $CO_{2e}$ as of 2015, taking up about 19.6% of Korea's entire emission and is about 144.7 million ton $CO_{2e}$ in 2017. The GHG emission of building sector is increasing at annual rate of 2.0% from 2001 to 2017. The GHG emission from electricity consumption in buildings is 91.8 million ton $CO_{2e}$ in 2017, is the highest $CO_2$ emission by energy source. The results show that the intensity of GHG emission of residential building sector is $40.6kg-CO_{2e}/m^2{\cdot}yr$ and that of commercial building sector is $68.4kg-CO_{2e}/m^2{\cdot}yr$.

Effects of Plant Types on Group Production Structure, Growth and Yield of Green Pepper (Capcicum annuum L.) in Greenhouse (시설고추 초형이 군락생산구조, 생육 및 수량에 미치는 영향)

  • Jeon, Hee;Kim, Kyung-Je
    • Journal of Bio-Environment Control
    • /
    • v.6 no.2
    • /
    • pp.86-91
    • /
    • 1997
  • This study was conducted to improve group production structure of green pepper in greenhouse. Plant was trained 45$^{\circ}$ branching, erection after 45$^{\circ}$ branching and erection. Light absorption index was calculated to investigate relation of light intensity and leaf area in different plant type according to plant height. Group production structure was analyzed with relative light intensity and dry weight of plant. In total growing seasons, group production structures were good in order of erect type after 45$^{\circ}$ branching > erect type > 45$^{\circ}$ branching type in view of light absorption, leaf and stem distribution. Plant height of erect type was taller than any other case, and average node length of 45$^{\circ}$ branching type was shorter than any other case. But stem diameter, leaf area, fresh weight and dry weight of erect type after 45$^{\circ}$ branching were superior to any other case. Yield is order of erect type after 45$^{\circ}$ branching > 45$^{\circ}$ branching type > erect type.

  • PDF

Evaluation of stress distribution with wind speed in a greenhouse structure

  • Hur, Deog-jae;Noh, Jung-Hun;Lee, Hyun ju;Song, Hyoung woon
    • Wind and Structures
    • /
    • v.27 no.5
    • /
    • pp.347-356
    • /
    • 2018
  • In this paper, stress distribution for a structurally stable greenhouse is considered in the present paper with subsequent investigation into the detailed stress distribution contour with the variation of self-weight and wind pressure level designation method under wind velocity of less than 30 m/sec. For reliable analysis, wind pressure coefficients of a single greenhouse unit were modeled and compared with experiment with correlation coefficient greater than 0.99. Wind load level was designated twofold: direct mapping of fluid dynamic analysis and conversion of modeled results into wind pressure coefficients ($C_P$). Finally, design criteria of EN1991-1-4 and NEN3859 were applied in terms of their wind pressure coefficients for comparison. $C_P$ of CFD result was low in the most of the modeled area but was high only in the first roof wind facing and the last lee facing areas. Besides, structural analysis results were similar in terms of stress distribution as per EN and direct mapping while NEN revealed higher level of stress for the last roof area. The maximum stress levels are arranged in decreasing order of mapping, EN, and NEN, generating 8% error observed between the EN and mapping results under 30 m/sec of wind velocity. On the other hand, effect of dead weight on the stress distribution was investigated via variation of high stress position with wind velocity, confirming shift of such position from the center to the forward head wind direction. The sensitivity of stress for wind velocity was less than 0.8% and negligible at wind velocity greater than 20 m/sec, thus eliminating self-weight effect.

Greenhouse Gas Emissions from Building Sector based on National Building Energy Database (국가 건물에너지 통합DB 기반 건물부문 온실가스 배출현황)

  • Ji, Chang-Yoon;Choi, Min-Seok;Gwon, Oh-In;Jung, Ha-Rim;Shin, Sung-Eun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.4
    • /
    • pp.143-152
    • /
    • 2020
  • This study analyzes in detail greenhouse gas emissions in building sector. To this end, this study used data on building characteristics (including building type, region, and construction year) and monthly energy consumptions (including electricity, city gas, and district heat) for all buildings from 2015 to 2018. These data were collected from the National Building Energy Database and the energy consumptions were converted into greenhouse gas (GHG) emissions. The total amount of GHG emissions from the building sector has increased steadily from 2015 (118.1MtCO2eq.) to 2018 (132.6MtCO2eq.). On the other hand, the more recently constructed buildings had lower GHG intensities. This result shows that strengthening building design criteria was effective on the reduction of GHG emissions in buildings, and that the increased buildings contributed to increasing GHG emissions of the building sector. In addition, sales facilities are thought to have the largest reduction potential as they had the highest amount of GHG emissions and GHG intensity. This study is expected to help establish new policies for GHG reduction in building sector as well as to evaluate the effects of existing policies.

Survey of ICT Apply to Plastic Greenhouse, Rack·Pinion Adaption to Single Span and CFD Analysis (온실 ICT융복합 실태조사와 복숭아형 랙피니언천창 적용 단동온실 및 CFD 유동해석)

  • Cho, Kyu Jeong;Kim, Ki Young;Yang, Won Mo
    • Journal of Bio-Environment Control
    • /
    • v.24 no.4
    • /
    • pp.308-316
    • /
    • 2015
  • This study was conducted to investigate the situation of ICT apply to plastic greenhouse, and the results be apply to design of new one. A CFD analysis were conducted to monitering the ventilation and energy saving of the single span greenhouse newly designed. The causes of delay to apply ICT to plastic greenhouse are the high cost for installation(24%), insufficiency of after services(19%), often disorder(16%), unskillful management of soft ware(15%), insufficient ICT efficiency(13%) and unsatisfying of income increase(12%). The parts of problem occurred in ICT plastic greenhouse are the structure, actuator, environmental control system and sensor(approximate 14%, respectively), remote control technique(13%), plant management technique(12%), energy saving technique(10%) and utilization of software(8%). In the condition of lateral window closed, the average wind speed changed to slow, but it was faster in the condition of leeward side window opened than in the condition of lee and winward side window opened. The air movement in the condition of lateral window closed occur by air moving fan not by out air. It is not affect the room temperature but effective the uniformity of room temperature. The average temperature of low height greenhouse was uniform than high height one. The average temperature in condition of 3rd curtain opened become same with outside temperature after 2 hours, but take more 5 hours in condition of 3rd curtain closed.

Disaster Prevention Technology in Response to Flooded Areas Using Drone Image-Based Inundation Monitoring and Prefabricated Rainwater Penetration Storage Block Structure (드론영상 기반 침수 모니터링 및 조립식 빗물 침투 저류블록 구조를 활용한 상습 침수지역 대응 방재기술)

  • Choi, Hee-Yong;Choi, Hyeong-Gil;Ryu, Jung-Rim;Kim, Won-Chang;Lee, Tae-Gyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.411-412
    • /
    • 2023
  • The purpose of this research and development is to develop a structure module that improves the efficiency and constructability of the layout structure as well as the design development of rainwater permeable storage tank blocks using inorganic binders and aggregates with the aim of reducing greenhouse gas (CO2) with eco-friendly materials. In addition, for the efficient response to flooding of the developed permeable storage structure, we present a technical solution for combining drone mapping technology and flood monitoring technology that can analyze topographical factors in detail.

  • PDF

Analysis of Wind Velocity Profile for Calculation of Wind Pressure on Greenhouse (온실의 풍압력 산정을 위한 풍속의 수직분포 분석)

  • Jung, Seung-Hyeon;Lee, Jong-Won;Lee, Si-Young;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.135-146
    • /
    • 2015
  • To provide the data necessary to determine the design wind speed for calculating the wind load acting on a greenhouse, we measured the wind speed below 10m height and analyzed the power law exponents at Buan and Gunwi. A wind speed greater than $5m{\cdot}s^{-1}$ is appropriate for calculating the power law exponent necessary to determine the wind speed distribution function according to height. We observed that the wind speed increased according to a power law function with increased height at Buan, showing a similar trend to the RDC and JGHA standards. Therefore, this result should be applied when determining the power law function for calculating the design wind speed of the greenhouse structure. The ordinary trend is that if terrain roughness increases the value of power law exponent also increases, but in the case of Gunwi the value of power law exponent was 0.06, which shows contrary value than that of the ordinary trend. This contrary trend was due to the elevations difference of 2m between tower installed and surrounding area, which cause contraction in streamline. The power law exponent started to decrease at 7 am, stopped decreasing and started to increase at 3 pm, and stopped increasing and remained constant at 12 pm at Buan. These changes correspond to the general change trends of the power law exponent. The calculated value of the shape parameter for Buan was 1.51, confirming that the wind characteristics at Buan, a reclaimed area near the coast, were similar to those of coastal areas in Jeju.

Structural Performance Evaluation of a Multi-span Greenhouse with Venlo-type Roof According to Bracing Installation (가새 설치에 따른 벤로형 지붕 연동온실의 구조성능 평가)

  • Shin, Hyun Ho;Choi, Man Kwon;Cho, Myeong Whan;Kim, Jin Hyun;Seo, Tae Cheol;Lee, Choung Kuen;Kim, Seung Yu
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.438-443
    • /
    • 2022
  • In this study, the lateral loading test was performed to analyze structural performance of multi-span plastic greenhouse through full-scale experiment and numerical analysis. In order to analyze the lateral stiffness and stress, we installed 9 displacement sensors and 19 strain gauge sensors on the specimen, respectively, and load of l mm per minute was applied until the specimen failure. In the comparison between the full-scale experiment and the structural analysis results of a multi-span greenhouse with venlo-type roof according to bracing installation, there was a large difference in the lateral stiffness of the structure. By installing a brace system, the lateral stiffness measured near the side elevation of the specimen increased by up 44%. As the bracing joint used in the field did not secure sufficient rigidity, the external force could not be transmitted to the entire structure properly. Therefore, it is necessary to establish a bracing construction method and design standards in order for a greenhouse to which bracing applied to have sufficient performance.

Analysis of CO2 Capture Efficiency in Relation to the Inlet Moisture Content of the Regenerator in the Continuous Process by using Sorbent Analysis (연속공정에서 고체흡수제의 입자분석을 통한 재생반응기 주입 수분량에 따른 CO2 회수효율 영향 분석)

  • Lee, Do-Young;Kim, Ki-Chan;Park, Young Cheol;Han, Moon-Hee;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.654-658
    • /
    • 2012
  • In this study, $CO_2$ capture efficiency in relation to the inlet moisture content of the regenerator was investigated using potassium-based sorbents in the continuous process composed of two bubbling fluidized-bed reactors, where solid outlet configuration in the regenerator was converted from underflow to overflow. XRD (X-ray Diffraction), SEM (Scanning Electron Microscope) and TGA were performed to find out the effect of water pre-treatment according to inlet moisture content in the regenerator. The $K_2CO_3{\cdot}1.5H_2O$ structure of solid sorbents has been increased as inlet moisture content of the regenerator increased. As a result, the $CO_2$ capture efficiency increased as the $K_2CO_3{\cdot}1.5H_2O$ structure of solid sorbents increased since the reactivity of the sorbents has been improved by that structure generated by the water pre-treatment. And $CO_2$ capture efficiency increased about 3~8% after sorbent outlet configuration of the regenerator was changed underflow to overflow.