• Title/Summary/Keyword: Greenhouse GasInventory and Research Center

Search Result 34, Processing Time 0.026 seconds

Estimation of Domestic Greenhouse Gas Emission of Refrigeration and Air Conditioning Sector adapting 2006 IPCC GL Tier 2b Method (국내 냉동 및 냉방부문 온실가스 배출량 산정 - 2006 IPCC GL Tier 2b 적용 -)

  • Shin, Myung-Hwan;Lyu, Young-Sook;Seo, Kyoung-Ae;Lee, Sue-Been;Lim, Cheolsoo;Lee, Sukjo
    • Journal of Climate Change Research
    • /
    • v.3 no.2
    • /
    • pp.117-128
    • /
    • 2012
  • The Government of South Korea has continued its effort to fixate virtuous circle of economic growth and climate change response to cope with international demands and pressure to commitment for greenhouse gas reduction effectively. Nationally, Korean Government has established "Enforcement of the Framework Act on Low carbon, Green Growth"(2010. 4. 13) to implement national mid-term GHG mitigation goal(30% reduction by 2020 compare to BAU), which established the foundation for phased GHG mitigation by setting up the sectoral and industrial goal, adopting GHG and Energy Target Management System. Also, follow-up measures are taken such as planning and control of mid-term and short-term mitigation target by detailed analysis of potential mitigation of sector and industry, building up the infrastructure for periodic and systematic analysis of target management. Likewise, it is required to establish more accurate, reliable and detailed sectoral GHG inventory for successfully establishment and implement the frame act. In comparison to the $CO_2$ emission, Especially fluorinated greenhouse gases (HFCs, PFCs, $SF_6$) are lacking research to build the greenhouse gas inventories to identify emissions sources and collection of the applicable collection activities data. In this study, with the refrigeration and air conditioning sector being used to fluorine refrigerant(HFCs) as the center, greenhouse gas emission estimation methodology for evaluating the feasibility of using this methodology look over and mobile air conditioning, fixed air conditioning, household refrigeration equipment, commercial refrigeration equipment for the greenhouse gas emissions were calculated. First look at in terms of methodology, refrigeration and air conditioning sector GHG emissions in developing country-specific emission factors and activity data of the industrial sector the construction of the DB is not enough, it's 2006 IPCC Guidelines Tier 2a (emission factor approach) rather than the Tier 2b (mass balance approach) deems appropriate, and each detail by process, sectoral activity data more accurate, if DB is built Tier 2a (emission factor approach) can be applied will also be judged. Refrigeration and air conditioning sector in 2009 due to the use of refrigerant greenhouse gas emissions ($CO_2eq.$) assessment results, portable air conditioner 1,974,646 ton to year, fixed-mount air conditioner 1,011,754 ton to year, household refrigeration unit 4,396 ton to year, commercial refrigeration equipment 1,263 ton to year was estimated to total 2,992,037 tons.

Analysis of the Relationship between CO2 Emissions, OCO-2 XCO2 and SIF in the Korean Peninsula (한반도 지역에서 CO2 배출량과 OCO-2 XCO2 및 SIF의 관계성 분석)

  • Yeji Hwang;Jaemin Kim;Yun Gon Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.2
    • /
    • pp.169-181
    • /
    • 2023
  • Recently, in order to reduce carbon dioxide (CO2) emissions, which is the main cause of global warming, Korea has declared carbon emission reduction targets and carbon neutral. Accurate assessment of regional emissions and atmospheric CO2 concentrations is becoming important as a result. In this study, we identified the spatiotemporal differences between satellite-based atmospheric CO2 concentration and CO2 emissions for the Korean Peninsula region using column-averaged CO2 dry-air mole fraction from the Orbiting Carbon Observatory-2 and emission inventory. And we explained these differences using solar-induced fluorescence (SIF), a photosynthetic reaction index according to vegetation growth. The Greenhouse Gas Inventory and Research Center (GIR) and Emissions Database for Global Atmospheric Research (EDGAR) emissions continued to increase in Korea from 2014 to 2018, but the satellite-based atmospheric CO2 concentration decreased in 2018, respectively. Regionally, GIR and EDGAR emissions increased in 2018 in Gyeonggi-do and Chungcheongbuk-do, but satellite-based CO2 concentrations decreased for the corresponding years. In addition, the correlation analysis between emissions and satellite-based CO2 concentration showed a low correlation of 0.22 (GIR) and 0.16 (EDGAR) in Seoul and Gangwon-do. Atmospheric CO2 concentrations showed a different correlation with SIF by region. In the CO2-SIF correlation analysis for the growing season (May to September), Seoul and Gyeonggi-do showed a negative correlation coefficient of -0.26, Chungcheongbuk-do and Gangwon-do showed a positive correlation coefficient of 0.46. Therefore, it can be suggested that consideration of the CO2 absorption process is necessary for analyzing the relationship between the atmospheric CO2 concentration and emission inventory.

Estimation of Fugitive Emission Factors of HFC-134a from Scrap Cold Drinking Vending Machine at Use- and Disposal-Phase (음료용 폐자동판매기에서의 HFC-134a 사용 및 폐기단계 탈루배출계수 결정에 대한 연구)

  • Lee, Youngphyo;Kim, Eui-Kun;Kim, Seungdo;Byun, Seokho;Kim, Hyerim;Park, Junho;Lee, Dongwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.350-355
    • /
    • 2013
  • Little information is available for emission pathway even if HFC-134a that is known as one of the major greenhouse gases has been broadly used in Korea. This paper attempts to clarify the emission characteristics of HFC-134a used for refrigerant of cold drinking vending machines (CDVMs) at the use- and disposal-phase. We measured the residual amounts in the scrap CDVMs of 47 by applying commercial recover for refrigerant. The first-order kinetic model was introduced and the emission rate would be proportional to the remaining quantity of refrigerant. The emission factor at the use-phase was determined indirectly to be $6.9{\pm}0.7$ %/yr within a confidence interval of 95%, using information on residual amount and elapsed operation time at the disposal point. Correspondingly, the annual emission rate of HFC-134a per CDVM was determined to be 11.6 g. The average residual rate of HFC-134a in scrap CDVMs was assessed to be $62.5{\pm}2.2%$, leading to a potential emission amount of 144.8 g per scrap CDVM. The chemical compositions of refrigerants from scrap passenger vehicles are quite similar to those of new refrigerants, suggesting that the refrigerants from scrap passenger vehicles could be reused. During the recovering process of refrigerant, the recovered refrigerant was contaminated by compressor lubricant that accounted for about 30% in weight. It is necessary to separate the refrigerant from the recovered material contaminated by lubricant for recycling and reuse the refrigerant.

Comparison of Sampling and Wall-to-Wall Methodologies for Reporting the GHG Inventory of the LULUCF Sector in Korea (LULUCF 부문 산림 온실가스 인벤토리 구축을 위한 Sampling과 Wall-to-Wall 방법론 비교)

  • Park, Eunbeen;Song, Cholho;Ham, Boyoung;Kim, Jiwon;Lee, Jongyeol;Choi, Sol-E;Lee, Woo-Kyun
    • Journal of Climate Change Research
    • /
    • v.9 no.4
    • /
    • pp.385-398
    • /
    • 2018
  • Although the importance of developing reliable and systematic GHG inventory has increased, the GIS/RS-based national scale LULUCF (Land Use, Land-Use Change and Forestry) sector analysis is insufficient in the context of the Paris Agreement. In this study, the change in $CO_2$ storage of forest land due to land use change is estimated using two GIS/RS methodologies, Sampling and Wall-to-Wall methods, from 2000 to 2010. Particularly, various imagery with sampling data and land cover maps are used for Sampling and Wall-to-Wall methods, respectively. This land use matrix of these methodologies and the national cadastral statistics are classified by six land-use categories (Forest land, Cropland, Grassland, Wetlands, Settlements, and Other land). The difference of area between the result of Sampling methods and the cadastral statistics decreases as the sample plot distance decreases. However, the difference is not significant under a 2 km sample plot. In the 2000s, the Wall-to-Wall method showed similar results to sampling under a 2 km distance except for the Settlement category. With the Wall-to-Wall method, $CO_2$ storage is higher than that of the Sampling method. Accordingly, the Wall-to-Wall method would be more advantageous than the Sampling method in the presence of sufficient spatial data for GHG inventory assessment. These results can contribute to establish an annual report system of national greenhouse gas inventory in the LULUCF sector.

Characteristics of Greenhouse Gas Emissions from Charcoal Kiln (숯가마에서 발생하는 온실가스 배출 특성)

  • Lee, Seul-Ki;Jeon, Eui-Chan;Park, Seong-Kyu;Choi, Sang-Jin
    • Journal of Climate Change Research
    • /
    • v.4 no.2
    • /
    • pp.115-126
    • /
    • 2013
  • Recently Korea considers the source of biomass burning emissions reflecting national characteristic, so that includes the inventory of emission source but preceding research is rarely implemented in Korea. Therefore, a study on characteristics of greenhouse gas emissions from biomass burning is necessary and it also makes the source management effectively when the climate-atmospheric management system takes effect. In this study, using the manufactured charcoal kiln and the number of experiment was three times to get a reliable experiment result. The sampling time was decided by changing degree in charcoal kiln and charcoal manufacturing process. The results of calculation greenhouse gas emission factor from charcoal kiln were $668g\;CO_2/kg$, $20g\;CH_4/kg$, $0.01g\;N_2O/kg$. Using the emission factor developed in this study, estimate the emissions from charcoal kiln in Korea. The results of calculation were $46,040ton\;CO_2/yr$, $1,378ton\;CH_4/yr$, $0.69ton\;N_2O/yr$ and greenhouse gas emissions applying GWP are as follows. $CH_4$ emissions was $28,947ton\;CO_2eq./yr$, $N_2O$ emissions was $214ton\;CO_2eq./yr$. As a results, Gross emissions of charcoal kiln in Korea was $75,201ton\;CO_2eq./yr$, but the oak used in this study is included to the biomass so emissions of $CO_2$ are excluded. Therefore the net emissions of charcoal kiln in Korea was $29,161ton\;CO_2eq./yr$.

The Development of N2O Emission Factor at Killn Type Pyrolysis Melting Facility (외열킬른형 열분해용융시설의 N2O 배출계수 개발)

  • Yun, Hyun-Ki;Lee, Dae Kyeom;Cho, Changsang;Kang, Seongmin;Yoon, Young joong;Jeon, Youngjae;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.8 no.3
    • /
    • pp.231-237
    • /
    • 2017
  • In this study, the $N_2O$ emission factor of the facility was developed by measuring the kiln type pyrolysis melting facility. This used PAS (Photoacoustic Spectroscopy) method and measured the $N_2O$ emission concentration. From March 2016 to April 2016, it was measured over a total of two times and $N_2O$ concentrations were measured continuously for 24 hours using a 24 hour continuous measuring instrument (LSE-4405). The measured $N_2O$ emission concentration of the pyrolysis melting facility was 0.263 ppm on average and the emission concentration distribution in the range of 0.013~0.733 ppm was obtained. Therefore, the $N_2O$ emission factor of the kiln-type pyrolysis melting facility was estimated to be $0.829gN_2O/ton$-Waste. As a result of comparing the $N_2O$ emission factor of the thermal kiln type pyrolysis melting facility and the previous study, previous studies were about 18 times higher. It is estimated that this is due to the difference of furnace temperature, oxygen concentration and denitrification facilities. It is considered that the study of the emission factor of pyrolysis melting facility is an important factor in improving the credibility of greenhouse gas inventory in waste incineration sector.

Analysis on CO2 Mitigation Potential and Economic Effect of Green Life in the Residential Sector in Korea (녹색생활 실천에 따른 가정부문의 이산화탄소 감축잠재량 및 경제적 효과 분석)

  • Jin, Hyung Ah;Yeo, So Young;Yoon, So Won;Kim, Dai Gon;Seo, Jeong Hyeon;Hong, Yoo Deog;Han, Jin Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.668-681
    • /
    • 2013
  • The Korean government announced a national mid-term target to reduce 30% of greenhouse gas (GHG) emissions from business-as usual (BAU) level by 2020 in a voluntary and independent manner. In this study, we examined the $CO_2$ mitigation potential and conducted an economic effect analysis of green living actions in households in Korea. We also proposed some ways to implement green life to achieve the national target. If green lifestyle takes root in households nationwide, $CO_2$ emission would be reduced to 27.3% of the emission in 2007. This would save the country about 4.93 trillion won per year and each household could save about 300,000 won per year, which accounts for about 0.5% of GDP (as of 2007). Considering the five-year plan for green growth to invest 2% of GDP in green growth every year, this would not only reduce the economic burden on households, industries and the country but also increase economic growth potential by reinvesting the saved resources into green growth. Heating and lighting would be the greatest contributor to GHG mitigation of green life in the residential sector. It means we could achieve the national goal by reducing unnecessary heating and lighting and using energy-saving electric home appliances. The implementation of green living actions would reduce a significant amount of greenhouse gas emissions, ultimately relieving the burden on businesses to reduce GHG emissions. And it is one of the most cost-effective mitigation tools in order to achieve the mid-term GHG mitigation goal.

Estimation of Economics thorough Prediction of Methane Generation using IPCC Guideline from C Sanitary Landfill (IPCC가이드라인을 이용한 중소도시 C위생매립장의 메탄가스 발생량 예측을 통한 경제성 평가)

  • Lee, Sang-Woo;Park, Seo-Yun;Chang, In-Soo;Kang, Byung-Wook;Park, Sang-Chan;Yeon, Ik-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.189.1-189.1
    • /
    • 2011
  • Global warming effect was intensified due to rapid growth of fossil fuel consumption caused by urbanization and industrialization. Various efforts was being done to solve the problems leading to anomaly climate such as flood, downpour, heavy snow. As a results of international efforts for management of global warming, Kyoto Protocol, which was passed in Kyoto, Japan in 1997, designated $CO_2$, $CH_4$, $N_2O$, HFCs, PFCs, $SF_6$ as a global warming gases. And IPCC(Intergovernmental Panel on Climate Change) suggested IPCC guideline for systematic establishment of national greenhouse gas inventory. Among five categories in IPCC guideline, the representative emission source of waste category is SWDS(solid waste disposal site). The concentrative research should progress for effective management of greenhouse gas related with waste. In this study, Tier1 and Tier2 methods which was suggested by 2006 IPCC(Intergovernmental Panel on Climate Change) guideline, was used to predict methane generation from C sanitary landfill located in Chungju area. To predict methane generation from C sanitary landfill, all factors were defaults values that were provided by 2006 IPCC guideline and Korea emission factors for Tier1 and Tier2 method. And economics of generated methane was estimated. From the predicted result using IPCC guideline, the methane generation was persistingly increased over a 9-year period(2000 ~ 2008). Aggregated amount of methane generation was about 3,017ton and 3,170ton predicted by Tier1 and Tier2, respectively. From the results of estimated economic value gained by generated methane from the C sanitary landfill for ten years from now(2010 ~ 2020), the profit was about 2.39 ~ 2.76 hundred million won.

  • PDF

Seasonal Variation of Hydraulic Gradient according to Rainfall in Unconfined Aquifer : Hyogyo-ri (자유면 대수층에서 강우량에 따른 수리경사 계절 변동 분석 : 효교리)

  • Kyoung-deok Park;Dong-hwan Kang;Won Gi Jo;In-Kyu Shin;Yun-Yeong Oh;MoonSu Kim;Hyun-Koo Kim
    • Journal of Environmental Science International
    • /
    • v.32 no.5
    • /
    • pp.303-313
    • /
    • 2023
  • In this study, the hydraulic gradient was calculated using the groundwater level and rainfall observed in the Hyogyo-ri area for a year, and the change in the hydraulic gradient according to the rainfall was analyzed. It was found that the groundwater level increased as the rainfall increased in all groundwater wells in the research site, and the groundwater level rise decreased as the altitude of the groundwater well increased. The hydraulic gradient in the research site ranged from 0.016 to 0.048, decreasing during rainfall and increasing after the end of the rainfall. As the rainfall increased, the groundwater level rise in the low-altitude area was more than the high-altitude area, and the hydraulic gradient decreased due to the difference in groundwater level rise according to the altitude. Through this study, it was found that the influence of rainfall is dominant for the fluctuation of the hydraulic gradient in the unconfined aquifer.

Comparison of the CO2 Emissions Estimations among Four Tier Methods for the Facilities from Different Industrial Sectors in Korea (국내 산업 부문에 대한 온실가스 배출량 산정 방법 결과 비교)

  • Kim, Hee Jin;Yeo, Min Ju;Kim, Yong Pyo;Jang, Geon Woo;Shin, Won Geun;Lee, Myung Hwoon;Choi, Hyung Wook
    • Journal of Climate Change Research
    • /
    • v.3 no.3
    • /
    • pp.195-209
    • /
    • 2012
  • There are four differentiated levels to quantify the amount of greenhouse gas emissions from a facility, which are Tier 1 to 4 based on the IPCC guidelines. In this study, the emission estimates from all tier levels were calculated to compare their total $CO_2$ emission results among themselves for seven facilities, including three sectors of electricity generation, municipal solid waste incineration, and cement manufacturing for three months between February and May 2011. Generally the measured $CO_2$ emissions by Tier 4 were higher than the calculated $CO_2$ emissions by Tier 3, which had been also observed for the power plants in the USA. It was found out that to obtain more reliable estimation for Tier 3, accurate analysis of the composition of the fuel used should be carried out. It was suggested that further refinement on the administrative guidelines be made to make it more robust.