• Title/Summary/Keyword: Greenhouse : Monitoring system

Search Result 120, Processing Time 0.028 seconds

Development of a Greenhouse Monitoring System Using Network (네트워크를 이용한 온실 감시 시스템 개발)

  • 공대광;임정호;진제용;류관희
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.11a
    • /
    • pp.71-77
    • /
    • 2001
  • 현재 급속히 발전하는 정보통신시스템은 산업계에 전형적인 중대한 변화를 가져왔다. 새롭고 향상된 하드웨어에 의해 진행된 클라이언트/서버 환경의 혁명적인 변화는 정보의 공유와 저장, 이동이 비약적으로 발전하고 있다. 광역 네트워크(WAN)는 그 대역폭의 제한을 풀고 무제한의 대역폭으로 넓혀가고 있다. 이제 곧 10배나 빠른 LAN 속도로 상호 연결된 수백만의 서버가 존재하는 네트워크가 지구상에 구축될 것이다. (중략)

  • PDF

Analysis of Research Trend and Core TechnologiesBased on ICT to Materialize Smart-farm (스마트팜 구현을 위한 연구동향 및 ICT 핵심기술 분석)

  • Yeo, Uk-hyeon;Lee, In-bok;Kwon, Kyeong-seok;Ha, Taehwan;Park, Se-jun;Kim, Rack-woo;Lee, Sang-yeon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.1
    • /
    • pp.30-41
    • /
    • 2016
  • Korean government has planned to increase the productivity of horticultural crops and to expand supply smart greenhouse for energy saving by modernization of horticultural facilities based on ICT in policy. However, the diversity and linkages of monitoring and control are significantly insufficient in the agricultural sector in the current situation. Therefore, development of a service system with smart-farm based on the internet of things(IoT) for intelligent systemization of all the process of agricultural production through remote control using complex algorithm for diverse monitoring and control is required. In this study, domestic and international research trend related to ICT-based horticultural facilities was briefly introduced and limits were analyzed in the domestic application of the advanced technology. Finally, future core technologies feasible to graft in agricultural field were reviewed.

Plant Growth Monitoring Using Thermography -Analysis of nutrient stress- (열영상을 이용한 작물 생장 감시 -영양분 스트레스 분석-)

  • 류관희;김기영;채희연
    • Journal of Biosystems Engineering
    • /
    • v.25 no.4
    • /
    • pp.293-300
    • /
    • 2000
  • Automated greenhouse production system often require crop growth monitoring involving accurate quantification of plant physiological properties. Conventional methods are usually burdensome, inaccurate, and harmful to crops. A thermal image analysis system can accomplish rapid and accurate measurements of physiological-property changes of stressed crops. In this research a thermal imaging system was used to measure the leaf-temperature changes of several crops according to nutrient stresses. Thermal images were obtained from lettuce, cucumber, and pepper plants. Plants were placed in growth chamber to provide relatively constant growth environment. Results showed that there were significant differences in the temperature of stressed plants and non-stressed plants. In a case of the both N deficiency and excess, the leaf temperatures of cucumber were $2^{\circ}C$ lower than controlled temperature. The leaf temperature of cucumber was $2^{\circ}C$ lower than controlled temperature only when it was under N excess stress. For the potassium deficiency or excess stress, the leaf temperaures of cucumber and hot pepper were $2^{\circ}C$ lower than controls, respectively. The phosphorous deficiency stress dropped the leaf temperatures of cucumber and hot pepper $2^{\circ}C$ and $1.5^{\circ}C$ below than controls. However, the leaf temperature of lettuce did not change. It was possible to detect the changes in leaf temperature by infrared thermography when subjected to nutrition stress. Since the changes in leaf temperatures were different each other for plants and kinds of stresses, however, it is necessary to add a nutrient measurement system to a plant-growth monitoring system using thermography.

  • PDF

Real Time Monitoring of Energy Efficiency Operation Indicator on Merchant Ships

  • Barro, Ronald Dela Cruz;Kim, Jun-Seong;Lee, Don-Chool
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.301-308
    • /
    • 2011
  • International Maritime Organization (IMO) proposed the Energy Efficiency Operation Indicator (EEOI) in 2005 and the Energy Efficiency Design Index (EEDI) in 2008 so as to address emission concern and regulation. Likewise, Ship Energy Efficiency Management Plan (SEEMP) and Greenhouse Gas (GHG) monitoring and management are also becoming an issue lately. This paper introduces the energy efficiency design index (operation indicator) monitoring system (EDiMS) software can continuously monitor $CO_2$, $NO_x$, $SO_x$, and PM values emitted from ship. The accurate inventory of ships GHG can be obtained from base of emission result during the engine shop test trial and the actual monitoring of shaft power and ship speed. In addition, the ability to store all exhaust emission and engine operation data can be applied as the useful tool of the inventory work of air pollution and ship energy management plan for the mitigation or reduction of ship emissions.

Current Status of Standardization for Quality Control of Hydrogen Fuel in Hydrogen Refueling Stations for Fuel Cell Electric Vehicles (수소충전소 내 연료전지용 수소연료 품질 관리 및 표준화 동향)

  • KIM, DONGKYUM;LIM, JEONG SIK;LEE, JEONGSOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.284-292
    • /
    • 2022
  • Hydrogen is promising a candidate for energy supporting the carbon neutrality policy for greenhouse gas reduction, which is being promoted in several countries, including Korea. Although challenging efforts-such as lowering the costs of green hydrogen production and fuel cells-remain, hydrogen fuel cell electric vehicles (FCEVs) are expected to play a significant role in the energy transition from fossil fuels to renewable energy. In line with this objective, the hydrogen FCEV working group in the International Organization for Standardization (ISO) compiled and revised international standards related to hydrogen refueling stations as of 2019. A well-established hydrogen quality management system based on the standard documents will increase the reliability of hydrogen charging stations and accelerate the use of FCEVs. In this study, among the published ISO standards and other references, the main requirements for managing charging stations and developing related techniques were summarized and explained. To respond preemptively to the growing FCEV market, a continuous hydrogen quality monitoring method suitable for use at hydrogen charging stations was proposed.

Performance Analysis of Balcony BIPV System (발코니형 BIPV시스템의 성능 분석)

  • Kim, Hyun-Il;Kang, Gi-Hwan;So, Jung-Hoon;Yu, Gwon-Jong;Park, Kyung-Eun;Lee, Kil-Song;Suh, Seung-Jik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.208-209
    • /
    • 2007
  • Photovoltaic(PV) based electricity production is pollution-free at the local as well as the global level, it does not emit greenhouse gases, it dose not dip into finite file resources and it can be easily integrated into the urban environment, close to major consumption needs. So BIPV(Building-Integrated Photovoltaics) system have been increased around the world. This paper presents measuring and analyzing performance of balcony BIPV system which have been installed and monitoring. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. By the results, it is very important to develop optimal design for the balcony PV system.

  • PDF

Closed Static Chamber Methods for Measurement of Methane Fluxes from a Rice Paddy: A Review (벼논 메탄 플럭스 측정용 폐쇄형 정적 챔버법: 고찰)

  • Ju, Okjung;Kang, Namgoo;Lim, Gapjune
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.2
    • /
    • pp.79-91
    • /
    • 2020
  • Accurate assessment of greenhouse gas emissions is a cornerstone of every climate change response study, and reliable assessment of greenhouse gas emission data is being used as a practical basis for the entire climate change prediction and modeling studies. Essential, fundamental technologies for estimating greenhouse gas emissions include an on-site monitoring technology, an evaluation methodology of uncertainty in emission factors, and a verification technology for reductions. The closed chamber method is being commonly used to measure gas fluxes between soil-vegetation and atmosphere. This method has the advantages of being simple, easily available and economical. This study presented the technical bases of the closed chamber method for measuring methane fluxes from a rice paddy. The methane fluxes from rice paddies occupy the largest portion of a single source of greenhouse gas in the agricultural field. We reviewed the international and the domestic studies on automated chamber monitoring systems that have been developed from manually operated chambers. Based on this review, we discussed scientific concerns on chamber methods with a particular focus on quality control for improving measurement reliability of field data.

Pi Logger : Low-cost Greenhouse Image and Environmental Data Collection System for Invigorating Smart Farm Propagation (Pi Logger : 스마트 팜 보급 확대를 위한 저가형 온실 영상 및 환경 데이터 수집 시스템)

  • Seong, Gi-Cheon;Kim, Young-Geun;Yang, Won-Mo;Kim, Won-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.11
    • /
    • pp.1121-1128
    • /
    • 2016
  • Our country of agriculture suffers problems such as aging, population decline, agricultural decline etc. To solve this problem, in the country, it is interest in Smart Farm System, a convenient and efficient system for the production through the convergence of ICT technology and agriculture. However, because of expensive construction costs and difficulty in securing human resources and training for Operating system, they are struggling to spread the actual farmers. Therefore, it is necessary to develop smart farm techniques suitable for such customized domestic environment. This study designed a system for collecting environment date in a greenhouse based on the low-cost embedded devices, and designed and implemented for the Web application that a user can easily use system. The implementation of the system lowers deployment costs and is expected to increase largely the spread of Smart Farm it can be easily accessed by using the smart phone.

Measurement Uncertainty of Methane Concentrations from a Rice Paddy Measured by a Closed Automated Chamber System (벼논에서 폐쇄형 자동 챔버 시스템으로 측정한 메탄 농도에 대한 요인별 측정 불확도 비교)

  • Ju, Ok Jung;Kang, Namgoo;Lim, Gap June
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.3
    • /
    • pp.228-236
    • /
    • 2020
  • BACKGROUND: The closed chamber method is the most commonly used for measuring greenhouse gas emissions from rice fields. This method has the advantages of being simple, easily available and economical. However, a measurement result using the chamber method is an estimated value and is complete when the uncertainty is estimated. The methane emissions from a rice paddy account for the largest portion of the greenhouse gas emissions in the agriculture sectors. Although assessment of uncertainty components affecting methane emission from a rice paddy is necessary to take account of dispersion characteristics, research on these uncertainty components is very rare to date. The goal of this study was to elucidate influencing factors on measurement uncertainty of methane concentrations measured by a closed automated chamber system from a rice paddy. METHODS AND RESULTS: The methane sampling system is located in the rice paddy in Gyeonggi-do Agricultural Research and Extension Services (37°13'15"N, 127°02'22"E). The primary measurement uncertainty components influencing methane concentrations (influencing factors) investigated in this research were repeatability, reproducibility and calibration in the aspects of methane sampling and analytical instrumentation. The magnitudes of the relative standard uncertainty of each influencing factor were quantified and compared. CONCLUSION: Results of this study showed what influencing factors were more important in determination of methane concentrations measured using the chamber system and analytical instrumentation located in the monitoring site. Quantifying the measurement uncertainty of the methane concentrations in this study would contribute to improving measurement quality of methane fluxes.