• Title/Summary/Keyword: Green building design

Search Result 386, Processing Time 0.028 seconds

A study of the interior finishing materials for improving residential environment (주거환경 개선을 위한 실내 마감재에 관한 연구)

  • Kwak, Jae-Hoon;Han, Hae-Ryon
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.05a
    • /
    • pp.207-211
    • /
    • 2005
  • This research is aimed to study the finishing material applied in interior space for improving residential environment. First of all, it finds out what is 'Sick Building Syndrome' and 'Sick House Syndrome', how harmful to human body about indoor air pollution substance (such as volatility organic compound, formaldehyde) and investigate the effect when the environment-friendly finishing material is used. Secondly, classify and examine all kind of finishing material applied in interior space. Finally, after emphasize the importance of environment-friendly finishing material from domestic or overseas, this research suggest the basic information of environment-friendly finishing material in order to use in the future buildings.

  • PDF

A Case Study on the Acclimatization's Housing for Environmental Load Reduction (환경부하 저감을 위한 기후순응주거 사례연구)

  • Cho, Sung-Woo;Oh, Se-Gyu
    • Journal of the Korean housing association
    • /
    • v.24 no.6
    • /
    • pp.69-79
    • /
    • 2013
  • The concept of sustainable development to preserve natural environment through economy in resources and energy is gradually distinguished since environmental problems as a series of air pollution and global warming take place now. Building occupies more than 1/3 of energy consumption in the whole world. Energy consumption of buildings caused a quick increase in the amount of energy use by air conditioning, which has a lot of effects on exhaustion of fossil energy as well as an increase in environmental load. Therefore, this research intends to suggest characteristics and direction for the designing of acclimatization's housing through the case study on acclimatization's housing. Acclimatization's housing is designed to reduce building load from the designing stage unlike green home or low-energy apartment. Also, factors which are commonly applied to acclimatization's housing are applied complexly by design strategic factors of Heating, Cooling and Lighting. The applied design factors make effects mutually and complexly. In addition, design strategy showed different priority by designing direction.

A Dynamic Approach for Evaluating the Validity of Boosting Pocliies for Green Standard for Energy and Environmental Design Certification (시스템 다이내믹스를 이용한 녹색건축인증제도 활성화 정책의 실효성 평가)

  • Kim, Jung-Hwa;Lee, Hyun-Soo;Park, Moonseo;Lee, Seulbi
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.1
    • /
    • pp.28-39
    • /
    • 2016
  • Since 2002, Korea Government has introduced Green Standard for Energy and Environmental Design Certification for reducing GHG emission in building area. However, total number of G-SEED Certification is only around 1% of total number of approved apartment buildings despite the various boosting policies. In this situation, most boosting policies and policy improvement researches are leaning toward the supplier's aspect. However, comprehensive relation and dynamics between consumer and supplier has to be considered because housing market is operated by market participants' mutual interaction. Therefore, this research presents system dynamics models based on decision making analysis of consumer and supplier in G-SEED Certification apartment building market. Then, this research evaluate the validity of boosting policies using the model. The proposed analysis can assist government to make next G-SEED Certification boosting policy.

Factor Deduction of the Checklist for Environmental Management in Construction Phase (시공단계 환경관리를 위한 체크리스트 항목 도출)

  • Kim, Chang-Won;Lee, Myungdo;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.139-141
    • /
    • 2013
  • Construction industry has been participated in the effort for the reduction of environmental pollution such as introduction of green building certification, enactment of environment related regulation. However these efforts are focused on the design and maintenance phases of entire life cycle, construction phase that can occur intensive environmental impact in a short period is insufficient. Therefore this study aim to derive environmental management factors in construction phase and assess them using reliability analysis and factor analysis. As a results, the 20 factors was classified into 4 superordinate such as 'plan and supervision', 'environmental factor management', 'licensing management', 'surrounding environment management'.Based on result of this study, further study should be developed the checklist for effective environmental management in construction phase.

  • PDF

A Study on the Analysis of Carbon Emissions by Transportation Distance of Building Materials (건축자재 운송거리에 따른 탄소배출량 분석에 관한 연구)

  • Kim, Hyeon-Suk;Tae, Sung-Ho;Lim, Hyo-Jin;Jang, Hyeong-Jae;Lee, Chung-Won
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.125-126
    • /
    • 2022
  • As environmental problems around the world become serious, Korea has also raised the greenhouse gas reduction in the building sector to 32.8% compared to 2018, and efforts to reduce carbon in buildings are expanding. Recently, research is being actively conducted to reduce carbon in the long term by expanding the scope of greenhouse gas indirect emissions (Scope3), and even within the domestic Green Standard for Energy and Environmental Design(G-SEED) by quantitatively evaluating the environmental impact of buildings during the entire life cycle. However, it is difficult to accurately evaluate the carbon emission of the transportation process by assuming the material transport distance in the evaluation of the Life Cycle Assessment(LCA). Therefore, in this study, the main building materials of the building were selected through case evaluation and the carbon emission of the material transport process was derived based on the actual transport distance, and this was compared and analyzed with the theoretical LCA results.

  • PDF

Complementary measures for Environmental Performance Evaluation Index of External Space of Green Standard for Energy and Environmental Design for Apartment Complex - Focused on the Respect of Response to Climate Change - (공동주택 녹색건축인증기준의 외부공간 환경성능 평가지표 보완방안 - 기후변화 대응 측면을 중심으로 -)

  • Ye, Tae-Gon;Kim, Kwang-Hyun;Kwon, Young-Sang
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.1
    • /
    • pp.3-14
    • /
    • 2018
  • An apartment complex is a building use with great potential to contribute to solving problems related to urban ecological environment and climate change. The first goal of this study is to grasp the current situation of application and limitations of the ecological area rate, which is a representative evaluation index used to evaluate the environmental performance of the external space of an apartment complex in Green Standard for Energy and Environmental Design (G-SEED). The second goal is to propose a prototype of the evaluation index for evaluating greenhouse gas (GHG) reduction performance in order to supplement the evaluation index for the environmental performance of the external space in terms of response to climate change. We analyzed 43 cases of apartment complexes certified according to G-SEED, which was enforced since July 1, 2010, and found application characteristics of each space type and the limitations of ecological area rate. We analyzed overseas green building certification systems such as LEED and BREEAM that derived implications for supplementing the limitations of ecological area rate, which is focused on the evaluation of soil and water circulation function, and set up a development direction of complementary measures. Through analysis of previous studies, relevant regulations and standards, and technical documents of the manufacturer, the heat island mitigation performance of the pavement and roof surfaces of the apartment complex and the carbon uptake performance of the trees in the apartment complex was selected as parameters to yield the GHG reduction performance of the external space of the apartment complex. Finally, a quantitative evaluation method for each parameter and a prototype of the evaluation index for the GHG reduction performance were proposed. As a result of applying the prototype to an apartment complex case, the possibility of adoption and applicability as an evaluation index of G-SEED were proved.

A Comparative Analysis of Domestic and Foreign Universities' Facility Management for Green Campus - Focusing on the Energy Management - (그린캠퍼스를 위한 국내.외 대학시설관리(FM) 비교분석 - 에너지관리 중심 -)

  • Shin, Eun-Young;Kim, Jun-Ha
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.1
    • /
    • pp.45-53
    • /
    • 2012
  • Recently, as the environment issue has been stand out, people's interests in energy consumption of the building have been increased as well. Especially, university has been classified as the one of the main causes of excessive energy consumption. Therefore, domestic and foreign universities are trying to build a green campus in an attempt for sustainable development. Since early 2000s, foreign universities have been aware that one of the main causes of global warming is an excessive consumption of energy in universities. Accordingly, they adopted various energy management programs for the conservation. Ultimately, enforcing energy conservation and using alternative energy resulted in lower expense and it was a great help for the universities. On the other hand, excessive consumption of energy in domestic universities has been considered as serious, which led them to become the second main energy consumers in 2010. However, it seems people do not truly recognize the impotance of energy management, therefore, relatively little attention has been paid to this matter. Based on Leadership in Energy & Environmental Design(LEED) rating systems for on-campus building operation and maintenance, this research suggests the evaluation standard to effectively analyze the energy management activity with the best practices conducted in foreign universities and to solve the problem of campus facilities management in domestic universities. The result shows that domestic universities do not have a designated task force for effective energy management and the lack of energy professionals hinders for the long term development. Therefore, domestic universities should recognize the seriousness of the excessive energy consumption and develop low carbon green campus through proactive management practices since this is very essential for domestic universities to get more competitive in this global era.

An Comparative Analysis of Certification Results for Pre-Certified Office Buildings according to G-SEED Revisions (녹색건축 인증제도 업무용 건축물 개정 전·후 인증결과 비교분석)

  • Yun, Yo-Sun;Chae, Chang-U;Kim, Yu-Jin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.8
    • /
    • pp.51-58
    • /
    • 2018
  • G-SEED has been introduced with the aim of reducing energy use and resources since 2002, as the system of certificating environmental friendliness of buildings to create comfortable environment. This study analyzed the changes of certification standard of G-SEED since the revision in 2016, comparing certification results of office buildings by grade, category and certification items between G-SEED 2013-2 version and revised version of 2016. Also, this study analyzed the average points and their standard deviation of certification items including both deleted items and newly added items and extracted items needed to be reviewed in the future revision. In the revision, G-SEED has been extended its certification system to involve existing buildings and Innovative Design categories newly introduced with revising the certification items and difficulties. In revised version of G-SEED, the certification grade appeared to change its acquisition ratio decreasing Green2 and increasing Green4, during Green1 and Green3 were similar in proportion. The average scores by categories appeared decrease in Energy and Environmental Pollution category and Materials and Resources category, on the other hand, Maintenance category appeared the highest increase in the average score. Otherwise, Land Use and Transportation, Water Circulation, Ecology, Indoor Environment categories appeared similar average scores both version of G-SEED. In addition, the Innovative Design which was newly introduced category, seems to expect gradual gaining high scores according to technology development in future, although its possession has shown lower scores in revised version.

A Study on Computer Simulation to Investigate Correlations between Temperature Controlling Effect of Green Roof System and the Photovoltaic Power Generation Efficiency (옥상녹화시스템의 기온조절효과와 태양광발전효율간의 상호연관성 규명을 위한 전산해석연구)

  • Kim, Tae Han;Park, Sung Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.70-79
    • /
    • 2013
  • These day cities experience serious climatic changes due to environmental load caused by disturbance in the circulation systems of water resources and energy. As technological improvement to respond to various climatic changes and disasters are also requested in the field of construction, inter-disciplinary studies linked to the establishment of sustainable environmental control and energy systems is required in a consilient perspective. This study aims to infer correlations in the impact of environmental changes caused by rooftop greening system on the photovoltaic power generation efficiency through computer simulation in an integrated perspective. By doing so, it seeks to provide basic study for developing a photovoltaic system integrated with building revegetation that is sustainable in environmental and resource aspects. A simulation showed that, in the case of sunshine hours in June, the green surface indicated temperature lowering effects of $9.19^{\circ}C$ on average compared to the non-green surface and temperature was $9.81^{\circ}C$ lower. Due to such greening effects, at the highest sunlight timepoint in June, Pmpp improved 119W and heat loss rate dropped 7.8%.

A Study on the Heating Characteristics of Radiant Floor Panel Using Heat Pipes with the Double Wick (이중 윅 타입 히트파이프를 이용한 바닥복사패널의 난방특성 연구)

  • Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.183-189
    • /
    • 2012
  • Most of the domestic residential buildings have used the traditional radiant heating system, circulating hot water through the cross-linked polyethylene(PE-X) pipe buried in the floor panel of the heating space. New type of the heating panel was recently developed using heat pipes with double wicks. Some experiments were carried out in this study to verify the thermal characteristics of this heating system at the unit heating space which surrounded by outer space whose temperature of air be maintained scheduled value with time. Through the various experiments with several parameters, such as flow rate, inlet and outlet temperatures of hot water and the heating duration and so on, we found that the floor heating system with heat pipes was able to reduce the pumping power for hot water circulation by 4~31% compared with the conventional panel heating system using PE-X pipe. These results could be used for optimal design and efficient operation of the heating system as well as improvement of thermal comfort.