• 제목/요약/키워드: Green Wall

검색결과 307건 처리시간 0.026초

그린리모델링 기숙사의 물리적환경 변화와 거주자평가 (Physical Environment Change and Occupancy Evaluation on Green-Remodeled University Dormitory)

  • 최윤정;이호연;이현정;김원배
    • 한국주거학회논문집
    • /
    • 제28권1호
    • /
    • pp.37-44
    • /
    • 2017
  • This study focuses on the university dormitory remodeled toward energy efficiency. The study has its purpose on deriving the aspects to be concerned for later green remodeling and enhancing the effects of green remodeling, by analyzing the changes of physical environment, changes of energy consumption amount, and needs of the residents. For this purpose, the study went through the review of project report from government office for green remodeling, field investigation of remodeling elements, and the occupancy evaluation by Focus Group Interview. FGI means interviewing small group of the residents who lived in the subjected dormitories both before and after the remodeling. As results, the elements of green remodeling in targeted dormitories were inner wall insulation, top-floor ceiling insulation, replacement of windows, installment of automatic entrance door and making transfer space connected the entrance door. As the parts of equipment system, EHP high-efficiency cooler, highly efficient radiator, upgraded LED lightings with covers, and automatic control system (only one building) were installed. Energy consumption was declined, and the satisfaction of residents was increased after the green remodeling. However, the aspects which were not improved or unsatisfying also have been detected. Therefore, the study states the suggestions each for the administrators, designers and planners, and residents to concern for enhancing the effects of green remodeling or construction of new dormitories.

리기다소나무 방부 정각재를 이용한 목재 옹벽의 강도 성능 평가 (Strength Properties of Wooden Model Retaining Wall Using Preservative Treated Square Timber of Domestic Pinus rigida Miller)

  • 박준철;김건호;이동흡;황원중;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제38권6호
    • /
    • pp.532-540
    • /
    • 2010
  • 국내산 주요 침엽수 소경목의 활용 방안으로 리기다소나무를 이용한 목재 모형 옹벽을 제작하여 강도 성능을 평가하였다. 목재 모형 옹벽은 가로, 세로 11 cm의 CUAZ-2 처리한 리기다소나무 방부 정각재를 사용하여 3개의 Type으로 제작하였다. 각 Type별 옹벽은 횡목 4층 종목 3층 총 7층의 높이 86 cm, 길이 300 cm, 폭 93 cm로 제작 하였으며 기본형인 Type I과 목재 사용량을 줄이기 위해 중간에 긴 종목과 짧은 종목을 번갈아 사용한 Type II, Type II와 동일하게 제작한 후 횡목의 연결부위를 보강목으로 보강한 Type III으로 제작하였다. 각 Type별 옹벽은 수평 재하 시험을 통한 강도 성능 평가와 화상처리를 통한 구조물의 변형을 검토하였다. 수평 재하 시험 결과 최대 하중을 비교해 보았을 때 Type I은 63.17 kN/m, Type II는 57.80 kN/m, Type III은 60.97 kN/m으로 나타났다. 화상 처리를 통해 측정된 전면부의 최상층 변형을 비교해 보았을 때 Type I에 비해 Type II의 변형이 약 1.5배 많은 변형을 보였으며 Type I과 Type III은 비슷한 변형을 보이는 것을 알 수 있었다. 실험 결과 Type III의 경우 목재 사용량을 절감하면서도 양호한 강도성능을 확인 할 수 있었다.

스마트 그린인프라 기술을 활용한 도로변 미세먼지 저감장치의 성능 및 유지·관리 비용 평가 (Evaluation of Performance and Maintenance Cost for Roadside's Particulate Matter Reduction Devices Using Smart Green Infrastructure Technology)

  • 송규성;석영선;임효숙;전진형
    • 한국환경복원기술학회지
    • /
    • 제25권4호
    • /
    • pp.15-31
    • /
    • 2022
  • The Green Purification Unit System (GPUS) is a green infrastructure facility applicable to the roadside to reduce particulate matter from road traffic. This study introduces two types of GPUS (type1 and type2) and assesses the performance and maintenance costs of each of them. The GPUS's performance analysis used the data collected in November 2021 after the installation of the GPUS type1 and type2 at the study site in Suwon. The changes in the particulate matter concentration near the GPUS were measured. The maintenance cost of GPUS type1 and type2 was assessed by calculating the initial installation cost and the management and repair cost after installation. The results of the performance analysis showed that the GPUS type1, which was manufactured by combining plants and electric dust collectors, had a superior particulate matter reduction performance. In particular, type1 produced a greater effect of particulate matter reduction in the time with a high concentration (50㎍/m3 or higher) of particulate matter due to the operation of electric dust collectors. GPUS type2, which was designed in the form of a plant wall without applying an electric dust collector, showed lower reduction performance than type1 but showed sufficiently improved performance compared to the existing band green area. Meanwhile, the GPUS type1 had three times higher costs for the initial installation than GPUS type2. In terms of costs for managing and repairing, it was evaluated that type1 would be slightly more costly than type2. Finally, this study discussed the applicability of two types of GPUS based on the result of the analysis of their particulate matter performance and maintenance cost at the same time. Since GPUS type2 has a cheaper cost than type1, it could be more economical. However, in the area suffering a high concentration of particulate matter, GPUS type1 would be more effective than type2. Therefore, the choice of GPUS types should rely on the status of particulate matter concentration in the area where GPUS is being installed.

The Study on Thermal Performance Evaluation of Building Envelope with VIPs

  • Jeon, Wan-Pyo;Kwon, Gyeong-Jin;Kim, Jin-Hee;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.5-10
    • /
    • 2016
  • Purpose: The energy consumption in buildings has continuously increased in some countries and it reaches almost 25% of the total energy use in korea. Therefore there are various efforts to minimize energy consumption in buildings, and the regulations on building envelope insulation have been tightened up gradually. To satisfy the building regulation, the use of vacuum insulation panels(VIPs) is increasing. VIP is a high performance insulation materials, so that it can be thinner than conventional insulation material. When VIP is applied in a building, it may cause thermal bridge, which occurs due to very low thermal conductivity compared to other building materials and the envelope of VIPs. Method: This study designed the capsulized VIPs using conventional insulation for reduction of the thermal bridge. Then designed VIPs were applied to a wall. The linear thermal transmittance and the effective thermal conductivity were analyzed by HEAT2 simulation program for two dimensional steady-state heat transfer. The result compared with a wall with non-capsulized VIPs. Result: It analyzed that the wall with capsulized VIPs had lower linear thermal transmittance and reduced the difference of the effective thermal transmittance with one dimensional thermal transmittance compared to that of the wall with non-capsulized VIPs.

장스팬이 가능한 친환경 공동주택용 철골 프리캐스트 합성보 개발 (Development of Long-Span Steel-Precast Composite Beam for Green Apartment Building)

  • 윤태호;홍원기;박선치;윤대영
    • KIEAE Journal
    • /
    • 제11권1호
    • /
    • pp.9-14
    • /
    • 2011
  • Currently, the multi-residential apartments used in Korea are mostly bearing wall apartments which don't satisfy consumers for the lack of architectural plan flexibility. And due to remodelling-incompatible, bearing wall apartments have to be reconstructed. It is, thus, necessary to develop multi-residential apartments utilizing composite beam that can replace the conventional bearing wall-type apartment buildings. Composite beams proposed in this paper ensure modification of space and quality control, while the floor heights are maintained at the same floor height as in bearing wall structures. This study analyzes the experimental behavior of composite beams with proper combination of structural steel, reinforced concrete, and precast concrete. By comparing with the theoretical analysis and experimental results, the accuracy of flexural moment capacity and neutral axis was evaluated. The experiments were performed by two simply-supported specimens using loading and unloading. When the analysis results were compared with the experimental results, the flexural moment capacity of the composite beam was shown with an error of approximately -0.5 to 0.1% at the maximum load limit state.

Analysis of hysteresis rule of energy-saving block and invisible multi-ribbed frame composite wall

  • Lin, Qiang;Li, Sheng-cai;Zhu, Yongfu
    • Structural Engineering and Mechanics
    • /
    • 제77권2호
    • /
    • pp.261-272
    • /
    • 2021
  • The energy-saving block and invisible multi-ribbed frame composite wall (EBIMFCW) is a new type of load-bearing wall. The study of this paper focus on it is hysteresis rule under horizontal cyclic loading. Firstly, based on the experimental data of the twelve specimens under horizontal cyclic loading, the influence of two important parameters of axial compression ratio and shear-span ratio on the restoring force model was analyzed. Secondly, a tetra-linear restoring force model considering four feature points and the degradation law of unloading stiffness was established by combining theoretical analysis and regression analysis of experimental data, and the theoretical formula of the peak load of the EBIMFCW was derived. Finally, the hysteretic path of the restoring force model was determined by analyzing the hysteresis characteristics of the typical hysteresis loop. The results show that the curves calculated by the tetra-linear restoring force model in this paper agree well with the experimental curves, especially the calculated values of the peak load of the wall are very close to the experimental values, which can provide a reference for the elastic-plastic analysis of the EBIMFCW.

기후디자인 기반 건축물통합형 입면녹화시스템 개발 방안에 관한 연구 (A Study on the Development Program of Building Integrated Vertical Greening System Based on Climate Design)

  • 박성은
    • 한국전통조경학회지
    • /
    • 제35권3호
    • /
    • pp.105-112
    • /
    • 2017
  • 도시화를 주도하는 건축, 도시개발 사업은 주변자연환경을 고려하지 않고 일관적인 개발행태로 인하여 기존 부지에 대한 생태성을 급진적으로 저하시켜 도시열섬화 현상, 대기오염, 도심 내 종 다양성 저감 등 환경 및 생태계를 교란하는 주요원인으로 인식되었다. 지속 가능한 시스템 중에서 도심 내 생태적 연결을 제공하는 건축물녹화는 기존의 건물을 지속 가능한 도시환경 시스템의 한 부분으로 전이시켜줄 수 있는 구체적 생태기술공법의 하나이다. 본연구에서는 체계적인 입면녹화 개발방안수립을 위해 기본기술개발방향, 기후환경인자, 기후디자인 기술요소, 소재 등을 고찰하였고 이에 준하여 입면녹화시스템 설계프로세스를 도식화하고 분석, 전략, 개발방안, 유형 설정의 순서로 건전한 한국형 입면녹화시스템 설계를 진행하였다. 국내 환경에 대응하는 지속가능한 입면녹화시스템 구축을 위해 식물학적, 시스템적 시스템 개발 및 발전방안 마련을 제시하고자 한다.

빌라 사보아의 재료 패턴 및 색채 사용 연구 (A Study on the Usage of the Color and the Pattern of Materials in Villa Savoye)

  • 김소희
    • 한국실내디자인학회논문집
    • /
    • 제17권5호
    • /
    • pp.133-140
    • /
    • 2008
  • This study is purposed to understand the usage of the color and the material pattern in detail and to apply for interior architecture. Many documents have prescribed the color and the pattern at random. While the usage of the color and the materials was ignored rather than architectural form, the importance of the color and the materials stands out in modern interior space. The villa, the weekend home of the Savoye family, was built between 1928 and 1931. Particularly, the villa Savoye was focused for this study. Le Corbusier viewed case pieces for storage and wall partition for division as architecture, and he units furniture and architecture by developing partition that could be painted either the wall color to become part of the wall or in contrasting colors to stand out as wall partition. He loved white and lie believed in using it for interiors, but noted that it should also be balanced with a wall related polychromy. Color became an integral part of white structure of the villa savoye that was raised on stilt with an exterior wall at the base painted green as a visual connection with the lawn. Color was used architecturally in the interior as well, with white walls interrupted by planes of pink, blue and red ocher and it gives the space an unexpected playfulness with tile color of the finishing materials. the various usage of the color and material patterns constitute an element of great architectural richness. They have a unique principle based on emotional order and make the man move to another space and experience the spacial connection.

완주 위봉사보광명전 백의관음벽화의 재료학적 특성 연구 (Study on the Material Characteristic of Baekeuikwaneum (the White-Robed Buddhist Goddess of Mercy) Wall-Painting of Bogwangmyungjun in Wibongsa, Wanju)

  • 김용선;이상진;최인숙;진병혁;이화수
    • 보존과학회지
    • /
    • 제30권1호
    • /
    • pp.55-65
    • /
    • 2014
  • 이 연구는 위봉사보광명전 백의관음벽화의 보존처리에 앞서 진행되어진 과학적 조사에 관한 결과물로써, 벽체의 입도분포 및 미세구조와 화학성분 그리고 광물 결정상을 분석하였으며, 안료 및 접착매질을 분석하였다. 또한 비파괴진단 방법인 초음파 탐사를 통해 벽화내부에 대한 안정성을 파악하였다. 분석 결과 벽체에 사용된 광물입자들은 중립질 이상의 모래와 세립질 이하 풍화토의 혼합물인 것으로 판단되며, 채색에 사용된 안료는 바탕층은 황토, 백색안료는 호분, 적색계열의 안료는 석간주를 사용하였고 녹색계열은 석록이 사용되었던 것으로 추정된다. 향후 벽화 보존처리에 있어 이와 같은 과학적 분석을 통한 보존처리를 실시한다면, 처리 시 안정성을 높이고 벽화의 보존관리를 위한 기초자료로 활용될 수 있을 것이다.

18~19세기 사찰벽화에 사용된 안료 비교 고찰 (Comparative Study on the Pigments Applied on the Wall Paintings of Temple in 18~19C)

  • 손영;강대일;이화수;이한형
    • 보존과학회지
    • /
    • 제29권4호
    • /
    • pp.445-450
    • /
    • 2013
  • 이 연구에서는 사찰벽화에 사용된 안료에 대한 성분 분석 자료들을 종합, 비교하여 조선 후기 사찰 벽화에 사용된 채색재료의 특징을 고찰하였다. 연구대상은 ED-XRF를 이용한 분석자료로 전국의 8개 사찰벽화 61점에 대한 것이다. 이들 벽화의 제작 시기는 대체로 18~19세기에 해당한다. 벽화 채색층의 색상은 대략 7가지 계통으로 분류되며, 백색은 Pb, Fe, 육색은 Pb, Ca, 황색은 Fe, 적색은 Fe, Pb, Hg, 녹색은 Cu, Fe, 청색은 As, Co가 검출되었고, 흑색에서는 색상원소가 검출되지 않았다. 자료들을 비교 분석해 본 결과 조선후기 경상도와 전라도 소재 사찰벽화에 사용된 안료들은 그 종류에 있어 시기나 지역적인 차이가 크게 관찰되지 않았다. 한편, 동종 안료라도 채색부위의 위치에 따라 다른 색상과의 혼색에 차이가 관찰되었다. 이것은 사찰벽화에서 선호되는 색상표현방식이나 안료의 귀천에 따라 그림에서의 위치(주제부와 주변부)에 따른 용도가 달랐음을 시사한다. 이러한 결과는 향후 비파괴 분석법을 이용한 사찰벽화 분석자료를 이해하는 데 참고자료로서 활용될 것으로 기대된다.