• 제목/요약/키워드: Green M&A

검색결과 2,446건 처리시간 0.028초

돌돔 (Oplegnathus fasciatus)의 수온 및 LED 광원에 대한 행동 분석 (Effect of water temperature and LED lights on the behavior of rock bream (Oplegnathus fasciatus))

  • 허겸;김민선;신현옥
    • 수산해양기술연구
    • /
    • 제53권3호
    • /
    • pp.240-245
    • /
    • 2017
  • In order to study for the growth of fish in the aquaculture industry, the behavior analysis of rock bream (Oplegnathus fasciatus) depending on the temperature and LED lights was conducted. In this study, water temperatures from 10 to 30 degrees were used. One red light (wave length: 622 nm; light power: 811 mW) and one green light (wave length: 518 nm; light power: 648 mW) were used. Behavior of the rock bream was analyzed at an average moving distance for one minutes (AMD) and a rate of movement. The mean AMD were respectively 5.3 m, 7.3 m and 3.0 m in the red LED light, green LED light and control condition. The mean rates of movement were 77%, 88% and 61% respectively in the red LED light, green LED light and control condition. The mean AMD during 24 hours were 3.1 m, 3.1 m and 3.3 m respectively in the red LED light, green LED light and control condition.

Profiling Green IT Leaders Quantitatively and Qualitatively

  • Kim, Yong Seog;Kwag, Seung Woog
    • Industrial Engineering and Management Systems
    • /
    • 제12권2호
    • /
    • pp.118-129
    • /
    • 2013
  • In this study, we intend to identify key financial variables that can accurately classify Green IT leaders against Green IT followers. In particular, we build and compare single and meta-classifiers to identify the relationship between environmental performance and financial performance, while focusing on selecting and interpreting a final prediction model with a smaller set of financial performance indicators. Our experimental results demonstrate that several key variables representing the size, financial resources, operational efficiency, and risk-taking tendency of an organization can successfully identify Green IT leaders with approximately 90% of accuracy. In addition, we find that Green IT leaders show a higher utilization rate of Web pages as a green marketing channel than Green IT followers while they share common layouts of Web publication to build green IT brands with some differences.

Appilication of a Green City Index as a Green Space Planning Index for the Low-Carbon Green City of Gangneung-si

  • Cho, Su-Hyun;Jo, Hyun-Ju
    • 한국환경과학회지
    • /
    • 제25권10호
    • /
    • pp.1381-1387
    • /
    • 2016
  • This study aims to establish baseline data for sustainable monitoring by applying the green city index (GCI), which is set up to evaluate the city level, to the city of Gangneung-si, which was designated as a pilot city for the Low-carbon Green Growth City project by the Ministry of Land, Infrastructure, and Transportation. The GCI was applied in the framework of European systems, while considering the social and economic status of Korea. Indicators from 7 areas-$CO_2$, energy, building, transportation, water, waste, and quality of atmosphere were analyzed, except for qualitative indicators. Results indicate that total $CO_2$ emissions were 30.8 tons per capita, or 2.2 tons per one million units of real GDP. The total final energy consumption was 0.231 TOE/capita, or 0.317 TOE per one million units of real GDP. The percentage of total energy derived from renewable resources was 0.41% and energy consumption by the building was $433.5Mwh/1,000m^2$. The total percentage of the working population travelling to work daily by public transportation (limited to bus) was 19%. Further, the total annual water consumption was $99m^3/capita$, and the water lost in the water distribution system was $0.057m^3/capita/day$. The total annual waste collected was 0.0077 ton per capita, The annual mean emission were 0.014 ppm/day for $NO_2$, 0.005 ppm/day for $SO_2$, and 0.019 ppm/day for $O_3$. The annual mean for PM10 emissions was $39{\mu}g/m^3/day$.

일본 고베시(神戶市) 포트아일랜드 가로녹지 구조 유형 연구 (A Study on the Structure Style of Street Green Spaces on Port Island, Kobe, Japan)

  • 곽정인;한봉호;노태환;곽남현
    • 한국조경학회지
    • /
    • 제43권4호
    • /
    • pp.62-74
    • /
    • 2015
  • 본 연구는 일본 고베시(神戶市) 해안 매립도시인 포트아일랜드 가로녹지의 지형구조별 도로 유형, 주변 토지이용, 식재구조를 조사 분석하여 녹지량이 풍부한 가로녹지 식재기법 사례를 제공하고자 수행하였다. 포트아일랜드(총면적 826ha)는 일본 내에서도 최초의 인공섬으로 항만시설과 본격적인 도시기능시설을 겸비한 해상문화도시이다. 연구대상지내 $55{\sim}285m^2$ 면적의 조사구 11개소를 설정하여 조사 한 결과, 가로녹지의 지형구조는 마운딩형, 사면형, 사면+평지형, 평지형의 4개 유형으로 구분되었고, 인접한 도로의 폭에 따라 지형구조가 변화하였다. 인접한 도로의 차선이 많아서 소음, 공해물질 등 영향을 많이 받는 지역은 마운딩형, 사면형, 사면+평지형 등의 지형구조와 광폭의 다층구조 녹지대를 조성하였고, 도로차선이 적은 지역인 경우, 평지형의 지형구조와 화관목 위주의 관목을 식재하여 가로띠녹지를 조성하였다. 인접한 토지이용은 공공기관, 공동주택지, 주상복합지, 상업업무지 등이었고, 식재개념은 중로(4차선)의 경우 완충+경관기능, 소로(2차선)의 경우 경관기능이었다. 식재종은 대만풍나무, 녹나무, 조구나무, 참죽나무, 담팔수, 은행나무, 벚나무, 느티나무, 종가시나무, 향나무, 목련, 철쭉류, 동백나무, 꽃댕강나무 등 다양하게 나타났다. 식재밀도는 교목층 0.02~0.08(0.04)주/$m^2$, 아교목층 0.02~0.08(0.04)주/$m^2$이었고, 녹피율은 교목층 40.0~173.7(93.0)%, 아교목층 2.1~79.8(34.9)%, 관목층 17.9~64.2(4.13)%이었다. 녹지용적계수는 교목층 $1.43{\sim}6.67(4.13)m^3/m^2$, 아교목층 $0.02{\sim}2.01(0.85)m^3/m^2$, 관목층 $0.14{\sim}0.58(0.26)m^3/m^2$이었다. 포트아일랜드 가로녹지의 녹피율은 서울시 주요 가로녹지에 비해 높은 수준이었고, 특히 관목층 녹피율과 녹지용적계수는 우리나라 주요 가로녹지와 비교하였을 때 많은 차이가 있었다. 본 연구 결과는 현재 우리나라에 조성되고 있는 해안 매립기반 도시의 가로녹지 조성 시 지형구조, 식재구조, 식재기능 등을 고려하여 다양한 기능을 수행하는 가로녹지 조성기법 사례지로 응용이 가능할 것으로 판단된다.

천연 Naphthoquinone계 Juglone의 KAPAS 저해 및 제초활성 특성 (Herbicidal Activity and KAPAS Inhibition of Juglone with Potential as Natural Herbicide)

  • 최정섭;임희경;서보람;김진석;최춘환;김영섭;류시용
    • 한국잡초학회지
    • /
    • 제31권3호
    • /
    • pp.240-249
    • /
    • 2011
  • 식물 유래 naphthoquinone계 juglone의 신규 제초제 작용점 KAPAS에 대한 in vitro 및 in vivo에서의 활성 평가를 통해 천연물 유래 제초제로서의 가능을 검토하였다. Juglone은 농도의존적인 반응으로 KAPAS를 효과적으로 저해하였으며, 50% 저해농도는 $9.5{\mu}M$이었다. 바랭이(Digitaria sanquinalis)에 대한 경엽처리에서 juglone 125, 250, 500 및 $1000{\mu}g\;mL^{-1}$ 농도에서의 활성정도는 각각 70, 95, 100 및 100%이었다. 또한, 8종의 화본과 및 광엽잡초에 대한 juglone 2,000 및 $1000{\mu}g\;mL^{-1}$ 농도에서의 살초력은 완전하였으며(100%), $500{\mu}g\;mL^{-1}$에서도 90~100%이었다. Juglone을 처리했을 때 나타나는 주요 증상은 고사(desiccation) 또는화염상(burndown)이었다. Juglone 처리에 의한 전해물질 누출은 광조건에 관계없이 농도의존적으로 일어났으나, 엽록소 함량 감소 정도는 광조건에서도 경미한 수준이었으며, 암 조건에서는 전혀 일어나지 않았다. Juglone에 의해 억제되었던 애기장대 종자의 발아율은 biotin 공급에 의해 뚜렷하게 회복되었다. 이상의 실험에 결과에 의하면 천연 naphthoquinone계 juglone은 신규 제초제 작용점 KAPAS를 효과적으로 저해하는 친환경적인 천연물 유래 제초제로서의 가능성을 확인하였다.

검량보정 검증의 실험적 적합성에 대한 연구 -치료적 약물검사를 중심으로- (An Empirical Validation Study for Calibration Verification in TDM Test)

  • 장상우;김남용;최호성;박용원;추경복;윤근영;박병옥
    • 대한임상검사과학회지
    • /
    • 제37권1호
    • /
    • pp.1-7
    • /
    • 2005
  • The purpose of this study was to verify (i) a consistent calibration verification for the assessment of method linearity and (ii) calibration agreement with calibration settings. We validated calibration verification through method linearity with different lot number of individual calibrators that span the working range for 9 tests except salicylate with control sample in test. We evaluated that it covered broad analyte range to assay from near zero to the top of the measuring range with 5 or 6 points every three times for 10 analytes in TDM test. Target values were plotted on X-axis with assigned or observed values on the Y-axis. Working range were as follows. Calibration verification of the measuring range (maximum to minimum values) has been validated asetaminophen 0.1 to $304.6_{\mu}g/mL$, salicylate 0 to $1005_{\mu}g/mL$, valproic acid 3.2 to $154.19_{\mu}g/mL$, digoxin 0.17 to 5.65 ng/mL, vancomycine 1.3 to $80.51_{\mu}g/mL$, carbarmazepine 0.1 to $22.3_{\mu}g/mL$, phenytonin 0.6 to $40.21_{\mu}g/mL$, theophyline 0.2 to $40.21_{\mu}g/mL$, primidone 0 to $24.07_{\mu}g/mL$, phenobarbital 0.6 to $60.0_{\mu}g/mL$. Drawing a straight line through five or six points of these data showed good linearity. We are sure that it is important to assess the calibration verification of a test method to ascertain the lowest and highest test results that are reliable.

  • PDF

Alumina Green Sheet의 동시소성용 텅스텐 페이스트 제조 및 금속 접합에 관한 연구 (A Study on Tungsten Paste for Metallization and Cofiring of an Alumina Green Sheet)

  • 박경리
    • 마이크로전자및패키징학회지
    • /
    • 제3권2호
    • /
    • pp.39-50
    • /
    • 1996
  • 본 연구에선 주어진 조성의 알루미나 green sheet에 대하여 텅스텐의 입경 및 산화 물의 조성을 변화시키므로써 수축률을 제어하여 camber를최소화하여 결합강도를 최대로 하 는 텅스텐 페스트조성을 찾아내는 것을 목적으로 하였다. 본 실험에서 사용한 텅스텐 분말 의 입경은 0.35$\mu$m, 0.6$\mu$m, 0.72$\mu$m, $1.5\mu$m, 1.9$\mu$m, 3.2$\mu$m이며 frit는 Al2O3, MgO, SiO2 와 Al2O3, CaO, SiO2를 사용하여 각각의 조성에 따라 함량을 변화시키며 실험하였다. 소성 은 154$0^{\circ}C$로 습윤 수소분위기에서 시행하였으며 사용된 알루미나 green sheet의 알루미나 중심 입경은 2.8$\mu$m이었다. 분석은 주사전자 현미경으로 미세구조를 관찰하였고 EPMA Line Profile로 원소 분석을 하였으며 잔류응력을 측정하기 위하여 XRD분석을 하였다. Frit 을 함유하지 않은 경우 텅스텐 분말의 입경이 1.9$\mu$mdlfEo 최대 접합 강도를 나타내었다. Frit을 함유한 경우 Mgo계 frit조성에서는 MgO/Al2O3/SiO3=1/1/1일 때 CaO계 frot 조성에 서는 CaO/Al2O3/SiO2=1/2/1일 때 최대 접합 강도를 나타내었다. Frit 함량을 변화시킨 경우 MgO계는 10wt%함유하였을 때 CaO 계는 5wt%함유하였을 때 최대 접합강도를 나타내었 다. Frit 함량을 변화시킨 경우 MgO계는 10wt%함유하였을 때, CaOr계는 5wt%함유하였을 때 최대 접합강도를 나타내었다.

GREEN TEA EXTRACT INHIBITS CATECHOLAMINE RELEASE IN THE PERFUSED RAT ADRENAL GLAND

  • Lim, Dong-Yoom;Shin, Hye-Gyeong
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.255.2-255.2
    • /
    • 2002
  • The present study was designed to investigate the effects of green tea extract (GTE) and epigallocatechin gallate (EGCG) on secretion of catecholamines (CA) in the isolated perfused rat adrenal gland. In the presence of GTE (100 ${\mu}$g/$m\ell$) into an adrenal vein for 60 min. CA secretory responses evoked by ACh (5.32 mM), high K+ (56 mM) and Bay-K-8644 (10 ${\mu}$M for 4 min) from the isolated perfused rat adrenal glands were greatly inhibited in a time-dependent fashion. (omitted)

  • PDF

Prediction of Axial Solid Holdups in a CFB Riser

  • Park, Sang-Soon;Chae, Ho-Jeong;Kim, Tae-Wan;Jeong, Kwang-Eun;Kim, Chul-Ung;Jeong, Soon-Yong;Lim, JongHun;Park, Young-Kwon;Lee, Dong Hyun
    • Korean Chemical Engineering Research
    • /
    • 제56권6호
    • /
    • pp.878-883
    • /
    • 2018
  • A circulating fluidized bed (CFB) has been used in various chemical industries because of good heat and mass transfer. In addition, the methanol to olefins (MTO) process requiring the CFB reactor has attracted a great deal of interest due to steep increase of oil price. To design a CFB reactor for MTO pilot process, therefore, we has examined the hydrodynamic properties of spherical catalysts with different particle size and developed a correlation equation to predict catalyst holdup in a riser of CFB reactor. The hydrodynamics of micro-spherical catalysts with average particle size of 53, 90 and 140 mm was evaluated in a $0.025m-ID{\times}4m-high$ CFB riser. We also developed a model described by a decay coefficient to predict solid hold-up distribution in the riser. The decay coefficient developed in this study could be expressed as a function of Froude number and dimensionless velocity ratio. This model could predict well the experimental data obtained from this work.

시설재배 쪽파와 부추에서 살충제 Bifenthrin과 Chlorfenapyr의 잔류특성 비교 (Comparision of the Residue Property of Insecticide Bifenthrin and Chlorfenapyr in Green Onion and Scallion under Greenhouse Condition)

  • 박종우;손경애;김태화;채석;심재룡;배병진;이해근;임건재;김진배;김장억
    • 농약과학회지
    • /
    • 제16권4호
    • /
    • pp.294-301
    • /
    • 2012
  • 일시에 수확하는 경채류 중 쪽파와 부추에 대한 살충제 bifenthrin와 chlorfenapyr의 잔류특성을 비교 조사하였다. 수확일을 기준으로 각각 1주일 간격으로 2회 살포한 후 수확당일, 수확 3일 전, 수확 7일 전, 수확 10일 전 및 수확 14일 전에 시료를 수거하여 잔류량을 조사하였다. 수확당일의 잔류량을 기초하여 작물 중 농약살포액의 부착량을 환산한 결과, 쪽파의 경우 123.0-125.5 mL/kg, 그리고 부추에서는 70.0-74 mL/kg으로 조사되어 쪽파가 부추에 비해 더 많은 살포액이 부착될 수 있는 것으로 나타났다. 각 작물에서 bifenthrin과 chlorfenapyr의 생육기간 중 농약의 분해소실 정도를 조사한 결과, 쪽파에서 bifenthrin의 분해소실곡선은 y = 1.0334 $e^{-0.0602x}$ ($R^2$= 0.8606), chlorfenapyr는 y = 2.2603 $e^{-0.0519x}$ ($R^2$= 0.9043)이었으며, 부추에서는 bifentrhin의 경우, y = 0.7693 $e^{-0.1823x}$ ($R^2$= 0.9756), chlorfenapyr는 y = 1.2940 $e^{-0.1051x}$ ($R^2$= 0.9782)으로 나타났다. 이 분해소실곡선을 이용하여 각 작물에서 두 농약의 분해반감기를 조사한 결과, bifenthrin의 경우, 쪽파에서 분해반감기는 11.51일이었으며, 부추에서는 3.80일로서 쪽파에서의 분해 반감기가 더 긴 것으로 나타났으며, chlorfenapyr의 경우에서도 쪽파 13.35일, 부추 6.59일로 쪽파에서의 분해반감기가 더 길었다. 쪽파와 부추에서 두 농약의 잔류특성이 비교되었을 때 농약살포 후 살포액의 부착량과 작물생육기간 중 농약의 분해반감기는 부추에서보다는 쪽파에서 더 많거나 긴 것으로 나타났다.