• Title/Summary/Keyword: Green Building Technology

Search Result 319, Processing Time 0.031 seconds

Extraction and Analysis for Emphasis Development Field in Green Construction Technology (녹색 건설기술의 중점 개발 영역에 대한 추출 및 분석)

  • Yang, Jin-Kook;Shin, Sung-Joon;Kim, Ki-Nam;Hwang, Chi-Ho;Jang, Yun-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.306-307
    • /
    • 2014
  • Green building technology has the potential a competitiveness. Reflecting this situation, the renewable energy market is growing rapidly. And, this field became value-added field in construction industry. In this study perform to prioritize the value improvements of green building technologies. To do this, first, we will extract potential development field through literature and case studies. Next, we will built a hierarchy structure based on the economic efficiency, technical skill, and policy. Third, we decide to prioritize between the items by performing AHP analysis.

  • PDF

Investigation and Analysis of Patents for the Thermal Bridge Breaker in Green Buildings (그린건축을 위한 열교차단 특허기술의 조사 및 분석 연구)

  • Kim, Young-Ho;Kim, Hyung-Joon;Lee, Hee-Young
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.2
    • /
    • pp.35-43
    • /
    • 2013
  • The green building is one of biggest factors to go the goal of energy saving and environmental conservation, "reduction of energy consumption, friendly energy technology, recycling of resource, and environmental pollution reduction technology. The purpose of these green buildings realized by the energy-saving technology such as the thermal bridge breaker(or thermal bridge block). Thermal bridges are localized elements that penetrate insulated portions of building envelope that results in heat loss. The purpose of this paper is to describe the technical interactions for patents of a thermal bridge breaker(TTB) used in green building practices, and be subject to investigation to TTB in the leading countries, that is, United State, Europe Union, Japan, and Korea. As a result, there are four TTB categories(roof, wall-slab connection, opening, footing) in house or building. The TTB categories is remarkable technology that is apparatus in slab-wall joints and sealing element of opening frame in walls.

A Study on the Development of G-SEED Accredited Professional System (녹색건축 전문가 자격제도 개발 연구)

  • Lee, Sang Min;Lee, Seung Min
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.13 no.1
    • /
    • pp.32-40
    • /
    • 2014
  • In an effort to resolve environmental pollution problems, developed countries enforce green building certification systems. The same is true in Korea. However compared professional accreditation system to certification systems did not systematically in Korea. Therefore, in accordance with development of green building related systems and technology the requirement for foster green building professionals is urgent. Accordingly this study is purposed to analyze and propose that green building professional accreditation system development and operation of the direction. Through data analysis domestic and international green building professional accreditation system for draw a development plan. And then conduct an expert Delphi survey reflected in the survey results to development plan.

Influence of Air-tightness on Heat Energy Performance in Post and Beam Building with Exposed Wood Frame

  • Kim, Hyun-Bae;Kim, Se-Jong;Oh, Jung-Kwon;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.319-326
    • /
    • 2012
  • Han-green building is one of the modernized Korean traditional buildings developed by Korea Forest Research Institute. This building was developed to increase the competitiveness of Korean traditional building using state-of-art technologies; hence Han-green building has the inherent characteristics of traditional building such as exposed wood frame in wall. Because of discontinuity in wall by the exposed wood frame, there is a concern on heat-air leaking in terms of energy performance. In this study, air-tightness of Han-green building was evaluated to investigate the influence of gaps between frames and in-fill walls. Blower door test was carried out to evaluate the air-tightness, and air-change rate (ACH50) was evaluated by averaging four set of pressurization and depressurization test. The air-change rate of Han-green house was 5.91 $h^{-1}$. To improve energy performance of Han-green house, thermal infrared images of Han-green house were taken in winter with heating to find out where the heat loss occurred. It was found that the building lost more heat through gaps between frames and in-fill walls rather than through other parts of this building. After covering all the gaps by taping, the blower door test was performed again, and the air-change rate was improved to 5.25 $h^{-1}$. From this analysis, it was concluded that the heated air can leak through the gaps between frames and walls. Therefore, when one designs the post and beam building with exposed frame, the detail design between frame and wall needs to be carefully dealt. However, Han-green building showed relatively high air-tightness comparing with other country research results.

Recent Research Trends for Green Building Thermal Insulation Materials (친환경 건축물 단열재 최근 연구 동향)

  • Park, Jong-Moon;Kim, Dong-Hwan;Suh, Dong-Jin
    • Clean Technology
    • /
    • v.18 no.1
    • /
    • pp.14-21
    • /
    • 2012
  • The pros and cons of green building thermal insulation materials and systems have been reviewed from traditional thermal insulation materials such as mineral wool and polyurethane to new thermal insulation materials like VIP and aerogel and future insulating VIM and DIM. VIPs and aerogels with very low thermal conductivity can use for green buildings to significantly increase residential area by reducing energy consumption. Aerogels can be produced as not only opaque and but also translucent forms, thus enabling a wide range of possible building application. For building applications, there are many properties to consider like building site adaptability and mechanical strength, fire protection, cost and environmental impact.

An Analysis on Building Energy Load along Core Position, Area Ratio and Orientation (코어 위치와 종횡비 및 방위에 따른 건물 에너지 부하 분석)

  • Kim, Jin-Ho;Park, Woo-Pyoung;Shin, Seung-Ho;Min, Joon-Ki;Kim, Dong-Hoon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.1
    • /
    • pp.15-19
    • /
    • 2013
  • In this Study, effect of core position, area ratio and orientation of building on energy load is examined using TRNSYS17. This parameters are major parameters of the conceptual design stage. Reference model is square floor plan($1,444m^2$), centered core and 29% core area ratio. As the results, without considering the building orientation, the annual heating load of central building with 1:1 area ratio is lowest ($10.33kWh/m^2yr$) and the annual cooling load of off-central building with 1:1 area ratio is lowest ($59.27kWh/m^2yr$). As area ratio is bigger, cooling load is lower and heating load is higher. But if we consider building orientation, orders of heating load and cooling load are changed for area ratio and orientation.

Development of Multi-function Sensor Integration Module System for Smart Green Building (스마트 그린빌딩 구현을 위한 다기능 센서 통합 모듈 시스템 개발)

  • Kim, Bong-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.4799-4804
    • /
    • 2013
  • Green IT technology for the growth of low-carbon green environment and future development of the new technology. Therefore, in this paper, data generated by the security module for RFID applications, smart green building Sung multi-function sensor integrated module that can be integrated environment for building monitoring and management system has been developed. The development of a thermal sensor, temperature sensor, smog sensor, CO2 sensor, O2 sensor, tension sensor and damage detection sensor module with integrated system module integrated multi-functional sensors implemented in the paper. In real-time monitoring by allowing was design and developed system that can be implemented smart green building environment for the environment inside buildings.

Fabrication of Lightweight Flexible c-Si Shingled Photovoltaic Modules for Building-Applied Photovoltaics (건물 부착형 고경량 유연성 슁글드 태양광 모듈)

  • Minseob, Kim;Min-Joon, Park;Jinho, Shin;Eunbi, Lee;Chaehwan, Jeong
    • Current Photovoltaic Research
    • /
    • v.10 no.4
    • /
    • pp.107-110
    • /
    • 2022
  • Lightweight and flexible photovoltaic (PV) modules are attractive for building-integrated photovoltaic (BIPV) applications because of their easy construction and applicability. In this study, we fabricated lightweight and flexible c-Si PV modules using ethylene tetrafluoroethylene (ETFE) front cover and shingled design string cells. The ETFE front cover instead of glass made the PV modules lighter in weight, and the shingled design string cells increased the flexibility. Finally, we fabricated a PV module with a conversion power of 240.08 W at an area of 1.25 m2 and weighed only 2 kg/m2. Moreover, to check the PV module's flexibility, we conducted a bending test. The difference of conversion power between the modules before and after bending shown was only 1.7 W, which showed a power reduction rate of about 0.7%.

Fabrication of High-power Shingled PV Modules Integrated with Bent Steel Plates for the Roof (절곡 강판 일체형 고출력 슁글드 태양광 모듈 제조)

  • Eunbi Lee;Min-Joon Park;Minseob Kim;Jinho Shin;Sungmin Youn
    • Current Photovoltaic Research
    • /
    • v.11 no.2
    • /
    • pp.54-57
    • /
    • 2023
  • Recently, requirements for improving the convenience of constructing BIPV (Building Integrated Photo Voltaic) modules had increased. To solve this problem, we fabricated shingled PV modules integrated with bent steel plates for building integrated photovoltaics. These PV modules could be constructed directly on the roof without the installation structure. We found optimal lamination conditions with supporting structures to fabricate a module on a bent steel plate. Moreover, we applied a shingled design to PV modules integrated with bent steel plates to achieve a high electrical output power. The shingled module with bent steel plates shows 142.80 W of solar-to-power conversion in 0.785 m2 area.

LOTUS: a Vietnamese Green Building Rating System and Implementation Issues

  • Duy, Hung Nguyen;Le-Hoai, Long;Kim, Soo Yong;Dang, Chau Ngoc;Lee, Young Dai;Lee, Sun Ho
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.513-517
    • /
    • 2015
  • Green construction has increasingly become a popular concept and standardization in the world. This paper presents an overview of a Vietnamese green building rating tool named LOTUS. This paper also presents some major similarities and differences between LOTUS and other well-known green rating tools. The interviews with some experts and practitioners about Green buildings in Vietnam have twofold aims. One is to help better understand the causes of the differences under practitioners' viewpoints. The second aim is to uncover the opportunities and the difficulties that the project stakeholders may encounter upon the implementation of Green Building construction projects in Vietnam.

  • PDF