• Title/Summary/Keyword: Green Building Index

Search Result 55, Processing Time 0.029 seconds

Variation Profiles of Temperature by Green Area of Apartments in Gangnam, Seoul (서울 강남지역 아파트단지의 녹지면적에 따른 온도변화 모형)

  • 홍석환;이경재
    • Korean Journal of Environment and Ecology
    • /
    • v.18 no.1
    • /
    • pp.53-60
    • /
    • 2004
  • This study was carried out to investigate the effect of green area in apartment complexes to variation of temperature. The inside temperature of each site was estimated by analyzing Landsat ETM+ image data. The factors on variation of temperature were landcover type, building density, and Normalised Difference Vegetation Index(NDVI). The results of correlation between inside temperature of apartment complex and land cover type showed that the green area ratio had negative(-) correlation and impermeable pavement ratio had positive(+) correlation. Building-to-land ratio was not significant with inside temperature. A coefficient of correlation between the temperature value and the value of permeable pavement ratio added up green area ratio was higher than a coefficient of correlation between the temperature value and the value of permeable pavement ratio added up impermeable pavement ratio. Thus we may define that permeable pavement area decrease urban temperature with green area in apartment complex. Floor area ratio had no significant correlation with inside temperature. Inside temperature was decreased as the NDVI was increased. To establish the temperature distribution model in a development apartment complex, As the result of regression analysis between inside temperature as dependent variable and permeable pave ratio+green area ratio, green area ratio, building-to-land ratio and NDIT as independent variables, only permeable pavement ratio added up green area ratio of the independent variables was accepted fur regression equation in both two seasons and adjusted coefficient of determination was 41.4 on September, 2000 and 40.4 on June,2001.

Study on Deriving Improvements through Analysis of BF Certification Evaluation Indicators for Parks and Park Facilities (공원 및 공원시설 BF인증 평가지표 분석을 통한 개선방향 도출 연구)

  • Kim, Mi Hye;Koo, Bonhak
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.13-29
    • /
    • 2022
  • According to the revision of the Convenience Act for Persons with Disabilities, parks and park facilities where the first park development plan is established after December 4, 2021 are mandatory, and parks must be equipped with convenience facilities for the disabled. Hence, this study aims to derive the improvements of the park evaluation index by analyzing the park certification evaluation index, the building certification evaluation index of park facilities, and the evaluation reports of the current certification status cases. As a research method, first, the certification of parks and park facilities were compared and reviewed with the Park Green Act, and differences in the certification process and certification performance were compared and analyzed. Second, differences and common items were derived by analyzing barrier free (BF)-certification evaluation indicators for parks and buildings. Third, improvement plans were derived after analyzing differences and problems in 4 BF-certified parks and four building certification cases of park facilities in certified parks, focusing on the self-evaluation report and examination results. As a result of analyzing the park and building evaluation indicators, the items for which the evaluation purpose, evaluation method, and evaluation items were commonly applied to 7 access roads for each facility, 5 parking areas for the disabled, 2 guide facilities for information facilities, 14 in 5 categories of sanitation facilities, and 1 for other facilities. In the case of sanitation facilities, there is no case where it was evaluated as a park. If the park does not have an attached toilet, the park is certified as a building. Hence, it would be essential to establish the concept of an attached toilet and discuss the application of the evaluation index on the park sanitation facility. The score of buildings in parks and park facilities was lower than that of the self-evaluation results, and the certification grades of buildings declined in three cases. The items with the highest standard deviation were BF walking continuity for parks and the path to the main entrance among access roads for buildings. As a result of analyzing the park and building evaluation results of 19 common evaluation items except for sanitary facilities, the difference in the grades of the evaluation items for each case site except for one item appeared. Therefore, applying common detailed calculation criteria for items evaluated in common with parks and buildings is needed. Since sanitation facilities have no cases of park certification and are not certified as buildings, it is essential to establish the concept of attached toilets and discuss the application of park sanitation evaluation indicators. It is necessary to develop an evaluation index suitable for the characteristics of the park, such as adjusting the items that are not evaluated in parks and establishing an evaluation index considering the ones of parks. It expects that this study would be used as primary data for improving park certification indicators.

Performance Evaluation System for Construction Environment of the Unified Waterproofing-Root Resistance Membrane layer of the Green Roof System (인공지반 녹화용 방수방근 복합공법의 시공환경을 고려한 성능평가 시스템 연구)

  • Park, Chang-Hwa;Oh, Sang-Keun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.189-199
    • /
    • 2011
  • Installation of a proper root barrier in a green roof system is very important in order to protect the concrete slab of roof and the root penetration in the waterproofing layer. To select the proper root barrier materials and methods, it is necessary to understand the environmental conditions affecting the waterproofing-root barrier system in green roof construction site. Therefore, we suggested as the environmental performance indexes four kinds of performance requirements; root penetration, chemical attack by chemical agent or fertilizer, load impact by soil depth and size of plant, and water pressure. The related four test methods were suggested for the inspection of these performance indexes. In this research, we could suggest for kinds of test methods as standard test methods to evaluate the environmental performance of waterproofing-root barrier for greening roof system.

Evaluation on the Cooling Performance of Geothermal-energy Using Heat Pump System in Mixed-use Residential Building (주상복합 건축물에 적용된 지열이용 히트펌프 시스템의 냉방성능 평가)

  • Kim, Yong-Shik;Kim, Jung-Heon;Hwang, Kwang-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.9-16
    • /
    • 2006
  • Geothermal-energy has been getting popular as a natural energy source for green buildings these days. Public building with gross area more than $3000m^2$, planned after March, 2005, should spend about 5% of total building cost for equipment run by natural energy source (e.g. geothermal, solar heat, solar power, etc) according to renewable energy promotion law in Korea. As a result geothermal-energy using heat pump system is emerging as a effective alternative for realistic and economic plan although design guidelines and construction code for the system is in progress and technical data is far from sufficient. The quantitative analysis on the performance of geothermal-energy using heat pump system is insufficient for appropriate design of it. In this paper, cooling performance of geothermal-energy using heat pump system of residential and retail etc. mixed-use building has been analyzed on the basis of temperature comparison between inlet and outlet of heat exchangers of the operating system. Additionally, dry-bulb temperature and relative humidity have been measured and analyzed together as an index of indoor thermal environment.

A Study on the Analysis of LCA tools for Eco-Building (친환경 건축물의 LCA 평가도구 비교분석 연구)

  • Son, Woo-Jin;Kang, Hae-Jin;Rhee, Eon-Ku
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.394-399
    • /
    • 2009
  • Since some decades ago, there has been a concern for resource depletion and environmental pollution associated with building properties. In addressing such impact of the built environment, there is a recognition of the existence of alternative building materials, fuels for energy supply as well as technologies for waste handling and disposal. Nevertheless, for long time, the choice between such alternatives was dictated by factors such as differences in prices and aesthetic values. A new important dimension in discriminating between different options is the environmental dimension. This aspect is important since buildings are one of the spatially big new additions to the natural environment that consume a lot of materials and energy during their long lifetime. Thus, with the environmental dimension kept in mind, a existing cost estimation needs to be changed. A new cost assessment method, Life Cycle Cost, should calculate overall costs with dimensional factors: investment and utility costs as well as maintenance costs over the lifetime of the building. Aiming to give an overview of the present status of Building Life Cycle Assessment(LCA) tools as a basis for further research and development including economic performance, this paper describes and compares 3 different tools for Life Cycle Assessment(LCA) and economic analysis of the green buildings. This paper compared these approaches based on various aspects. These include economic analysis method, evaluation duration, data of results(index). Use of the comparison analysis is to produce a better picture and indicate profits and shortcomings for the tools as a group; thus providing important direction improvement of LCA tool as well as further research and development of this group of tools.

  • PDF

A Study of Models for Marketing Strategy in the Eco-friendly Apartment Housing Using Discriminant Analysis (판별분석을 이용한 친환경 아파트의 마케팅 전략에 관한 연구)

  • Kil, Ki-Suck;Lee, Joo-Hyung
    • KIEAE Journal
    • /
    • v.7 no.3
    • /
    • pp.11-20
    • /
    • 2007
  • The purpose of this study is to analyse the effects of the eco-friendly factors on the apartment housing price rise and to suggest the desirable way of marketing strategy for apartment housing. For the analysis, the data of apartment sites in Seoul had been collected from September 2006 to February 2007. The data consisted of 95 apartment sites in Seoul. Data were analyzed with descriptives, crosstabs, and discriminant analysis by SPSS/PC for Window. Following result was obtained. The eco-friendly apartment housing price rate in Seoul was determined by eco-friendly landscape, green space rate, house unit size, installment sale price per pyeong, floor space index, distance from subway station when it was not considered the impact of building age, construction company's brand, and autonomous districts. Findings of this research can provide valuable information for marketing strategy of housing construction company.

The Characteristic of Laws on the Kind of Urban Green Spaces and the Legal Requirements for the Green Spaces of Urban Habitat in China (중국의 도시녹지 종류와 도시거주구 녹지의 설치 기준에 관한 법제도의 현황과 특성)

  • Shin, Ick-Soon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.3
    • /
    • pp.1-11
    • /
    • 2013
  • This study investigated Chinese Laws on the kind of urban green spaces and the legal requirements for the green spaces of urban habitat and analyzed the specificities of them intending to provide basic data to suggest bringing in or not the relevant Chinese Laws to Korea. This study can be summarized as follows: First, the concept of Chinese urban green spaces(g.s.) classified by 5 kinds(park g.s., production g.s., protection g.s., attachment g.s., the others g.s.) placed the park and green spaces in the same category unlike the Korean urban green spaces that only distinguishes between park and green spaces. The Chinese Urban Park is classified by 4 kinds(composite park, community park, special park, linear park) at the 'Standard for urban green spaces classification' which is below in rank of the legal system. Second, in case of calculation for green spaces ratio of urban green spaces in China, the green rooftop landscaping area should not be included as a green spaces area except the rooftop of a basement or semi basement building to which residents have easy access. The green spaces requirements and compulsory secure ratio by 3 habitat kinds(habitat, small habit, minimum habitat) of when to act as a residential plan is regulated. Third, the green spaces system is obligated to establish at habitat green spaces plan and is specified to conserve and improve existing trees and green spaces. The green spaces ratio on reconstruction for old habitat is relaxed to be lower than for new habitat and a gradient of green spaces is peculiarly clarified. The details and requirements for establishment and the minimum area intending for each classes of the central green spaces(habitat park, children park, minimum habitat's green spaces) are regulated. Especially at a garden style of minimum habitat's green spaces, intervals between the south and north houses and a compulsory security for green spaces area classifying into two groups(closing type green spaces and open type green spaces) by a middle-rise or high-rise building are clarified. System of calculation for green spaces area is presented at a special regulation. Fourth, a general index(area/person) of public green spaces within habitat to achieve by 3 habitat kinds is determined, in this case, the index on reconstruction for a deterioration zone can be relaxed to be lower to the extent of a specified quantity. A location and scale, minimum width and minimum area per place of public green spaces are regulated. A space plot principle including adjacent to a road, greening area ratio against total area, security of open space and the shadow line boundary of sunshine are also regulated to intend for public green spaces. Fifth, the minimum horizontal distance between the underground cables and the surrounding greening trees are regulated as the considerable items for green spaces when setting up the underground cables. The principle to establish green spaces within public service facilities is regulated according to the kind of service contents. It shall be examined in order to import or not the special regulations that only exist in Chinese Laws but not in Korean Laws. The result of this study will contribute to gain the domestic landscape architect's' sympathy of the research related to Chinese urban green spaces laws requiring immediate attention and will be a good chance to advance into the internationalization of Korean Landscape Architectural Laws.

Analysis of Thermal Environment Improving Effects of Green Curtain in Summer (Green Curtain 형식의 벽면녹화시스템을 통한 여름철 건물 실내 열환경 비교 분석)

  • Lee, Sunyoung;Jo, Sangman;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.5
    • /
    • pp.80-89
    • /
    • 2022
  • In order to solve the limitations of horizontal thermal environment improvement, this study compared the thermal environment of the indoor and outdoor of a building in summer according to the presence or absence of a green curtain, a vertical greening method. In the summer of 2021, the air temperature, relative humidity, wind speed, and shortwave and longwave radiation were measured at a central point inside a building and the grass field outside of the building to determine the human thermal sensation index, PET and UTCI. As a result, the green curtain showed an average 1.6℃ cooler air temperature during the daytime, but it did not have an effect at night. For relative humidity, it showed higher humidity indoors by an average of 5.6% and 1.0% during the daytime and at night, respectively. Wind speed was 1.4-1.8 ms-1 and 1.4-1.5 ms-1 higher outdoors on average during the daytime and at night, respectively, showing a high value outdoors regardless of whether a green curtain was installed. The green curtain showed an average indoor mean radiant temperature reduction effect of 4.7℃ during the daytime, but it did not have an effect at night. In PET and UTCI, the green curtain reduced the indoor PET by about a 1/3 level, an average of 2.1℃, and the indoor UTCI by about a 1/6 level, an average of 1.1℃, during the daytime. However, no effects appeared in PET and UTCI at night. For landscape planning, a green curtain can effectively modify the thermal environment during the daytime in summer.

Manufacturing artificial lightweight aggregates using coal bottom ash and clay (석탄 바닥재와 점토를 이용한 인공경량골재 제조)

  • Kim, Kang-Duk;Kang, Seung-Gu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.6
    • /
    • pp.277-282
    • /
    • 2007
  • The artificial lightweight aggregate (ALA) was manufactured using coal bottom ashes produced from a thermoelectric power plant with clay and, the sintering temperature and batch composition dependence upon physical properties of ALA were studied. The bottom ash (BA) had 13wt% coarse particle (>4.75mm) and showed very irregular shape so should be crushed to fine particles to be formed with clay by extrusion process. Also the bottom ash contained a many unburned carbon which generates the gas by oxidation and lighten a aggregate during a sintering process. Plastic index of green bodies decreased with increasing bottom ash content but the extrusion forming process was possible for the green body containing BA up to 40wt% whose plastic index and plastic limit were around 10 and 22 respectively. The ALA containing $30{\sim}40wt%$ BA sintered at $1100{\sim}1200^{\circ}C$ showed a volume specific density of $1.3{\sim}1.5$ and water absorption of $13{\sim}15%$ and could be appled for high-rise building and super-long bridge.

A Study on Development Priority of Undeveloped Urban Neighborhood Park in Case of Daegu Metropolitan City (미개발 근린공원의 개발 우선순위 결정 -대구광역시를 대상으로-)

  • 이기철;김경완
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.29 no.1
    • /
    • pp.80-91
    • /
    • 2001
  • The purpose of this research is to provide a basic knowledge to open up for undeveloped park in process of the park policy establishment by setting up the priority of park development and valuation factor, valuation index as well as building a basic material to undeveloped neighborhood park in Daegu Metropolitan City. Thirteen urban neighborhood parks(1,841,663$m^2$) in the Daegu Metropolitan City were selected for this study. Analyzing and reviewing the previous research and literature review were conducted, and the evaluation index and analysis criteria were constructed to decide the development priority of parks. The results of this research are as follows; 1) Following to the result of the expert questionnaire test in order to estimate weight of valuation factors. It had a high score in available population, and estimated amount of the gross compensation, unpurchased land rate. On the other hand park rate of autonomous district, altitude, rate of population increase in autonomous district and a low score. 2) Generally, most f the plain type parks had a high score in the Sea level, land using pattern, an estimated amount of the gross compensation, but hill type parks had a high score the rate of green covered, park area for one person of administration building. 3) Daebong, Soosung, Dosan, 2.28 youth, Kyungnam parks were selected high priority. Soochang, Donsibong, Janggi, Dongin parks were selected middle priority. Bokhyun, Galsan, Manchon, Gusoosan parks, which were selected low priority. This research for undeveloped park is a basic research step to open up. Three many difficult things in shortage of the basic material for building valuation factor and measuring of the method measurement. The application of weight which make a decision importance among the valuation factor should have ore reasonable study and more scientific research from now because there still remains a lot of shortage of positive materials in there.

  • PDF