• Title/Summary/Keyword: Gravity filtration

Search Result 29, Processing Time 0.02 seconds

Reduction of bacterial regrowth in treated water by minimizing water stagnation in the filtrate line of a gravity-driven membrane system

  • Yi, JongChan;Lee, Jonghun;Jung, Hyejin;Park, Pyung-Kyu;Noh, Soo Hong
    • Environmental Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.17-23
    • /
    • 2019
  • This study monitored changes in the level of heterotrophic bacteria in the filtrate and investigated the effect of stagnant water on it, using a batch-operated, gravity-driven membrane system for household water treatment. The filtration test was carried out in the presence and absence of stagnant water in the filtrate line. The results showed that stagnant water accelerated the heterotrophic bacteria levels, measured by heterotrophic plate count, even though the heterotrophic plate count of the filtrate finally increased up to $10^5CFU/mL$ regardless of the presence of stagnant water. When the change in heterotrophic plate count of a batch was monitored over filtration time, heterotrophic plate count of the filtrate rapidly decreased within 5 min for each batch filtration. Biofilm formation on the filtrate line was observed in the presence of stagnant water. The biofilm fully covered the filtrate line and contained numerous microorganisms. During storage after filtration, heterotrophic plate count increased exponentially. To improve the filtrate quality of a filtration-based household water treatment system, therefore, the stagnant water in the filtrate line should be minimized, the filtrate produced at the first 5 min is recommended not to be used as potable water, and the storage of filtrate should be avoided.

Comparison of Filtration Efficiency of Membranes for Harvesting Microalgae using a Gravity-Filtration Device (중력 여과장치 이용 미세조류 수확을 위한 여과막의 효율성 비교)

  • Shin, Dong-Woo;Cho, Yonghee;Kim, Ki-Hyun;Kim, HanByeol;Park, Hanwool;Kim, Z-Hun;Lim, Sang-Min;Lee, Choul-Gyun
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.9 no.1
    • /
    • pp.8-13
    • /
    • 2017
  • Cost-effective microalgae harvesting methods are necessary for economical production of algal biodiesel. In this study, membranes with various pore sizes and materials were examined for their potentials in application to gravity-filtration of Tetraselmis sp. KCTC12432BP. For this test, 10 L of Tetraselmis sp. culture (2 g/L) was loaded on each membrane and filtration rates were measured. Among the tested materials, a woven cotton fabric showed the fastest water drain rate (0.73 L/hr) without serious cell leakage. Cell density of the concentrates after filtration was 6.8 g/L, indicating 3.4-fold concentration compared with the initial algal culture. The result suggests that the woven cotton fabric could serve as filtration membrane for harvesting Tetraselmis sp. among the tested ones.

Determination of the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis (역삼투법 해수담수화 전처리 여과공정의 최적조건)

  • Kim, Seung-Hyun;Yoon, Jong-Sup;Lee, Seockheon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.207-214
    • /
    • 2009
  • This study examines the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is treated through a gravity filter column while $FeCl_3$ is added as coagulant. The conditions of coagulantd osage, media depth, filtration rate, and backwash time are evaluated. The study results show that the filtrate quality improved with increasing coagulant dosage, but head loss rapidly increased. After 4mg/L, the unit filter run volume reduced to less than $200m^3/m^2$. Considering the head loss development, 4mg/L is determined as the optimum dosage. The better filtrate qualities are obtained with depth of 100cm than that of 80cm. The two stage filtration, which outperformed the single stage filtration, is suggested for treatment of Masan bay. The filtration rate of 5m/h is decided as the optimum condition considering the head loss development. At 10m/h, the filtrate quality deteriorated even though the extent was minimal, and head loss increased rapidly. The backwash time of 10 min is decided appropriate.

Octimization of Conditions of Filtration and Concentration of Methanol Extract for Recovery of Paclitaxel from Plant Cell Culture (식물세포배양으로부터 Paclitaxel 회수를 위한 메탄올 추출액의 여과 및 농축 조건 최적화)

  • Kim, Jin-Hyun
    • KSBB Journal
    • /
    • v.22 no.4
    • /
    • pp.197-200
    • /
    • 2007
  • This study examined the conditions of filtration and concentration of methanol extract from biomass. Filtration efficiency was improved by adding diatomaceous earth as a filter aid. The optimal amount of diatomaceous earth was 6% (w/w) to reduce the filtration time. The filtration time was reduced by 4.2% in first extraction, 30.0% in second extraction, 22.8% in third extraction, and 19.0% in fourth extraction, respectively. The optimal temperature of water bath was below 50$^{\circ}C$ for preventing paclitaxel degradation during concentration of methanol extract using a rotary evaporator. The temperature of concentrated solution in rotary evaporator was relatively low compared to bath temperature because of latent heat of evaporation. The stopping point of concentration in rotary evaporator for the following step was at a specific gravity of 0.96 of the concentrated solution in terms of the purity and yield of paclitaxel. This information is very useful for mass extraction of biomass for the recovery of paclitaxel from plant cell culture.

Role of Detached Particles During Initial Filtration Phase (여과초기에서의 탈착된 입자의 거동)

  • Kim, Ja-Kyum;Tobiason, John E.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.16-24
    • /
    • 2005
  • Mathematical model was developed to verify a sequential particle removal taking place in a granular media gravity filter. Consequential multi-layer filtration cycle model was applied to verify the fraction of filter effluent particles that are filter influent particles that were never removed as well as the fraction of filter effluent particles that were detached after deposition were performed through laboratory experiments. Three sizes of marker particles were injected ahead of the filter column as a pulse in the presence of four sizes of polystyrene particles that were used as a primary source of particles in the raw suspension to investigate particle attachment alone in contrast to net removal from attachment and detachment. Microscopic counting of filter effluent particles was assumed to reflect attachment. Experimental results indicated that particle detachment is significant beginning from the early phase of filtration. For each size of fluorescent microspheres at one filter depth, fluorescent microsphere removal increased with filter runtime to a maximum due to ripening. The detached fraction of effluent particles increased with particle size and filter depth. The presence of detached particles and the increasing fraction of detached particles in deeper bed were confirmed.

From Deep Bed Filter to Membrane Filtration: Process Intensification, Cost and Energy Considerations (입자분리를 위한 여과방식에 따른 비용-효율 분석)

  • BEN AIM, Roger;Kwon, Dae-young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.144-148
    • /
    • 2005
  • The industrial development of large scale deep bed filters has been a very important step in the process of drinking water production and more recently in the tertiary treatment of wastewater. The target of deep bed filtration is the retention is the retention of small particles generally smaller than 30 microns at relatively small concentration, generally less than 30 mg/l from natural water (surface water or aquifers) or secondary treated wastewater. The relation between the retention efficiency and the characteristics of the particles has been extensively studied experimentally and through different models of retention. During the last years the development of new technologies (fiber filter, membrane modules) lead to more intensive processes compared to conventional sand filtration. Fiber filters can combine intensification with a decrease in specific energy needed however they cannot be operated under gravity like sand filters. Membrane filters (UF or MF) are much more intensive and efficient than sand filters. The specific energy needed is not so high (about $0.1Kwh/M^3$) but is higher than sand or fiber filter. A Life Cycle Analysis (LCA) has to be made for a complete comparison between these technologies taking in account that the efficiency of particle retention obtained by membrane filters is unique.

Water Treatment Application of a Large Pore Micro-Filtration Membrane and Its Problems (대기공 정밀여과막의 수처리 응용 및 문제점)

  • Yun, Chang-Han;Kim, Jeong-Hak;Lee, Kang Won;Park, Sung Ho
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.194-200
    • /
    • 2014
  • The purpose of this study was to evaluate the performance of newly developed Large Pore Micro-Filtration (LPMF) membrane in Lab size for the application of water treatment, and to find its problems with solutions. The out-to-inside filtration hollow fiber LPMF membrane of which average pore size was $5{\mu}m$ was used at this study and its material was the PET braid reinforced PVDF. Filtration tests were done through gravity with 30 cm water head difference or pressure below 1.5 bar, and the backwash was done instantaneously with the filtrate after pressurizing it to about 4 bar. The water flux of the LPMF membrane with 0.2 bar TMP (Trans Membrane Pressure) was 2 times higher than $0.4{\mu}m$ MF membrane with $0.05{\mu}m$ UF filtrate of the tap water and it was measured also with 20~30 cm water head difference which showed over 800 LMH at 30 cm water head difference. And Time-To-Filter (TTF) was performed by using $5{\mu}m$ filter paper to optimize coagulants and dosage which enhanced filtrate's turbidity and stabilized filtration flux. When the LPMF was operated with 30 cm gravity with very high dose of inorganic coagulants, the flux was maintained over 80 LMH with 93.5~99.5% turbidity removal. Especially, the filtration was maintained stably in the flux and about 97% of the recovery rate by instantaneous pressurized backwash with about 4 bar of the filtrate when the packing density was about 19%. But there was instability in filtration, since the TMP was continuously going up by inefficient backwash when the packing density was 43%.

Analysis of Membrane Fouling Reduction by Natural Convection Instability Flow in Membrane Filtration of Colloidal Solution: Application of Blocking Filtration Model (콜로이드 용액의 막여과에서 자연대류 불안정 흐름의 막오염 저감 효과 해석: 막힘여과 모델의 적용)

  • Kim, Ye-Ji;Youm, Kyung-Ho
    • Membrane Journal
    • /
    • v.29 no.6
    • /
    • pp.329-338
    • /
    • 2019
  • The constant-pressure and constant-flux membrane filtration experiments of alumina colloidal solution are performed to investigate defouling effect of the natural convection instability flow (NCIF) induced in membrane module. The permeate flux at constant-pressure and the transmembrane pressure (TMP) at constant-flux experiments are measured by changes the inclined angle (0, 90 and 180°) of membrane module to the gravity, and flux results are analyzed by using the blocking filtration model. NCIF are more induced as the inclined angles increased from 0° to 180°, and the maximum induced NCIF at 180° angle enhances flux to 2.8 times and reduces TMP to 85% after two-hour operation. As a result of analyzing flux data by applying the blocking filtration model, it is more reasonable to analyze them by using the intermediate blocking model within 15-minute operation time and then thereafter times by using the cake filtration model. The induced NCIF at 180° angle reduces the intermediate blocking fouling at 52% in the early operation time of 15-minute and thereafter the cake layer fouling at 93%. The main membrane fouling control mechanism of NCIF induced in membrane module is evaluated as suppressing the formation of the cake layer of particulate colloidal materials on membrane surface.

Effects of GBF Treatment Conditions and Scrap Ratio on the Electric Conductivity of Commercial Pure Aluminum (공업용 순알루미늄의 전기전도도에 미치는 스크랩비율 및 GBF처리조건의 영향)

  • Hwang, Nam-Gyu;Kim, Young-Chan;Choi, Se-Won;Kang, Chang-Seok;Hong, Sung-Kil
    • Journal of Korea Foundry Society
    • /
    • v.31 no.3
    • /
    • pp.130-136
    • /
    • 2011
  • Effects of GBF (gas bubbling filtration) treatment conditions and scrap ratio on the electric conductivity of a commercial pure aluminum for diecasting were investigated using by specific gravity and electrical conductivity measurement system, hydrogen gas analyzer, XRD, and EDS. Electrical conductivities of specimen mixed Al scrap ratio until 60% from 0% were decreased with increasing the precipitates amount and size of AlFeSi ternary intermetallic compound on the grain boundary as well as amount of porosity in the grain. On the other hand, electrical conductivities was reincreased gradually in spite of scrap ratio increase from 80% to 100%. Size of AlFeSi compound formed on the grain boundary were coarsened with the increament of scrap ratios untill 80% and GBF treatment time simultaneously.

Analysis of Membrane Fouling Reduction by Natural Convection Instability Flow in Membrane Filtration of Protein Solution Using Blocking Filtration Model (막힘여과 모델에 의한 단백질 용액의 막여과에서 자연대류 불안정 흐름의 막오염 제어 효과 해석)

  • Kim, Ye-Ji;Youm, Kyung-Ho
    • Membrane Journal
    • /
    • v.29 no.1
    • /
    • pp.18-29
    • /
    • 2019
  • The dead-end ultrafiltration (UF) of BSA protein solution was performed to investigate the defouling effects of natural convection instability flow (NCIF) induced in membrane module. The permeate fluxes were measured according to the inclined angles ($0{\sim}180^{\circ}$) of membrane module with respect to gravity, and analyzed using the blocking filtration model. NCIF are more induced as the inclined angles increased from $0^{\circ}$ to $180^{\circ}$, and the induced NCIF enhances flux. Comparing the fluxes at $0^{\circ}$ inclined angle (no NCIF induction) and $180^{\circ}$ (maximum NCIF induction), the flux enhancements by NCIF induction are increased about 5 times in the short-term UF operation (2 hours) and about 17 times in the long-term operation (20 hours). As applying the blocking filtration model, it is more suitable to analyze the flux results by using the intermediate blocking model in the early times of UF operation within 15 minutes and then thereafter times by using the cake filtration model. NCIF induced at $180^{\circ}$ inclined angle reduces the intermediate blocking fouling at about 67% in the early times operation and thereafter the cake layer fouling at about 99.9%. The main defouling mechanism of NCIF induced in the membrane module is suppress the formation of protein cake layer.