• 제목/요약/키워드: Gravity Balance

검색결과 116건 처리시간 0.026초

타워크레인 붕괴사고의 구조적 분석 (Structural Analysis for the Collapse Accident of Tower Crane)

  • 이명구;노민래
    • 한국안전학회지
    • /
    • 제16권4호
    • /
    • pp.147-152
    • /
    • 2001
  • The tower cranes are the very useful construction machine in the high place works. But they are very susceptible to the load balance, the wind load and the hanging load because they are the very slender structures and those center of gravity is located in the upper part. Therefore, the collapse accidents of tower one have repeatedly happened during the assemble or disassemble works. The correcting frame may has often used in order to correct the error in the setting of foundation anchors. The goal of this study is that propose the methods preventible the collapse accident of tower crane which is constructed by using the correcting frame. In order to accomplish the goal of this study, the field survey, the reference investigation and the structure analysis were performed for the collapse accident of tower crane using the correcting frame. This study result in the methods preventible the same accident.

  • PDF

Conceptual design of light bascule bridge

  • Xu, Weiwei;Ding, Hanshan;Lu, Zhitao
    • Structural Engineering and Mechanics
    • /
    • 제29권4호
    • /
    • pp.381-390
    • /
    • 2008
  • This paper proposed a conceptual design of bascule bridge, which is a new kind of movable bridge with an aim of reducing the weight of superstructure. Compared with the traditional bascule bridge, the light bascule bridge chooses cable-stayed bridge with inclined pylon as its superstructure; therefore, the functions of balance-weight and structure will fuse into one. Otherwise, it adopts moving counterweight to adjust its center of gravity (CG) to open or close the bridge. In order to lighten the superstructure, it uses contact springs to auxiliary retract, and intelligent prestressing system (IPS) to control the main girder's deformation. Simultaneously the vibration control scheme of structure is discussed. Starting from establishing the mechanical model of bridge, this article tries to analyze the conditions that the design parameters of structure and attachments should satisfy to. After the design procedure was presented, an example was also adopted to explain the primary design process of this kind bridge.

다자유도 수동식 중력보상장치 기반의 6자유도 산업용 로봇 (6 DOF Industrial Robot Based on Multi-DOF Counterbalance Mechanism)

  • 안국현;송재복
    • 로봇학회논문지
    • /
    • 제12권1호
    • /
    • pp.11-18
    • /
    • 2017
  • Static balance of an articulated robot arm at various configurations requires a torque compensating for the gravitational torque of each joint due to the robot mass. Such compensation torque can be provided by a spring-based counterbalance mechanism. However, simple installation of a counterbalance mechanism at each pitch joint does not work because the gravitational torque at each joint is dependent on other joints. In this paper, a 6 DOF industrial robot arm based on the parallelogram for multi-DOF counterbalancing is proposed to cope with this problem. Two passive counterbalance mechanisms are applied to pitch joints, which reduces the required torque at each joint by compensating the gravitational torque. The performance of this mechanism is evaluated experimentally.

Development of droplet entrainment and deposition models for horizontal flow

  • Schimpf, Joshua Kim;Kim, Kyung Doo;Heo, Jaeseok;Kim, Byoung Jae
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.379-388
    • /
    • 2018
  • Models for the rate of atomization and deposition of droplets for stratified and annular flow in horizontal pipes are presented. The entrained fraction is the result of a balance between the rate of atomization of the liquid layer that is in contact with air and the rate of deposition of droplets. The rate of deposition is strongly affected by gravity in horizontal pipes. The gravitational settling of droplets is influenced by droplet size: heavier droplets deposit more rapidly. Model calculation and simulation results are compared with experimental data from various diameter pipes. Validation for the suggested models was performed by comparing the Safety and Performance Analysis Code for Nuclear Power Plants calculation results with the droplet experimental data obtained in various diameter horizontal pipes.

Optimum Angle of Incidence for General Anteroposterior Radiographic Image According to Lordosis angle : For Obese People

  • Kwak, Jong Hyeok;Kim, Gyeong Rip;Cho, Hee Jung;Moon, Sung Jin;Lee, Eun Sook;Sung, Soon Ki
    • International Journal of Contents
    • /
    • 제17권1호
    • /
    • pp.18-26
    • /
    • 2021
  • The obesity leads to be the result of the weakening of anatomical structure as well as the gravity effect. And, the obesity interferes with normal sagittal balance and fails to maintain a straight posture with minimal energy. Therefore, the obesity can be an important factor in causing back pain by changing the lumbar lordosis. In this study, we will present an appropriate angle of incidence for obese people to reduce the image distortion of L4, L5 during a general anteroposterior radiography examination. To reduce image distortion according to the change of lordosis, the angle of incidence was applied 9 ° and 21 ° to L4 and L5 vertebra body when obesity and low back pain (LBP) perform the general anteroposterior radiography examination.

타이어 제조공장 가류공정의 온열환경 개선에 관한 연구 (Improvement of hot work environment in the curing processes of a tire manufacturing company)

  • 임정호;김태형
    • 한국산업보건학회지
    • /
    • 제21권1호
    • /
    • pp.1-10
    • /
    • 2011
  • Generally, the tire curing process is the process in which the sulfur is added and subsequently the tire is heated to give the tire elasticity. In this process, all kinds of the chemicals in the tire are emitted with a lot of heat. The chemical fume and heat aggravate the work environment. To solve this problem, 92 local exhaust ventilators and 8 gravity ventilators were used, but not satisfactory yet. Preliminary survey showed that the temperatures in the process were very high: 30.3, 32.9 and $37.2^{\circ}C$ at 2, 4 and 6m above the ground level, respectively in the winter (outside temperature was $2^{\circ}C$). It can be imagined that the process is severely hot in the summer time. The higher temperature distribution in the higher space tells us that the hot plume could not be removed with the existing ventilation systems. Therefore, in this study, some alternative ventilation systems were designed. The partitions were used to contain the hot plume to increase the capture efficiency. The gravity ventilators were newly designed to improve the extraction efficiency of hot fume. To satisfy the balance of pressure in the curing process, some supply air system was introduced by renewing the existing air conditioning system. Many alternative solutions were evaluated by using computational fluid dynamics modelling. The best and applicable solution was selected and the existing ventilation system was modified. After implementing the new ventilation system, the hot environment was much improved. The temperature reduction in the curing process was about $6.4^{\circ}C$.

피동 주입 시험 장치의 척도 해석 및 설계 방법론 연구 (Study on Scaling Analysis and Design Methodology of Passive Injection Test Facility)

  • 배황;이민규;류성욱;신수재;김영인;이성재;박현식
    • 한국유체기계학회 논문집
    • /
    • 제19권5호
    • /
    • pp.50-60
    • /
    • 2016
  • A design methodology of the modeled test facility to conserve an injection performance of a passive safety injection system is proposed. This safety injection system is composed of a core makeup tank and a safety injection tank. Individual tanks are connected with pressure balance line on the top side and injection line on the bottom side. It is important to conserve the scaled initial injection flow rate and total injection time since this system can be operated by small gravity head without any active pumps. Differential pressure distribution of the injection line induced by the gravity head is determined by the vertical length and elevation of each tank. However, the total injection time is adjustable by the flow resistance coefficient of the injection line. The scaling methodology for the tank and flow resistance coefficient is suggested. A key point of this test facility design is a scaling analysis for the flow resistance coefficient. The scaling analysis proposed on this paper is based on the volume scaling law with the same vertical length to the prototype and can be extended to a model with a reduced vertical length. A set of passive injection test were performed for the tanks with the same volume and the different length. The test results on the initial flow rate and total injection time showed the almost same injection characteristics and they were in good agreement with the design values.

부여산 귀사문석의 보석학적 특성 연구 (Gemmological Characterization of Precious Serpentine from Booyo, Korea)

  • 김원사;우영균;이재열;김경수
    • 한국광물학회지
    • /
    • 제9권2호
    • /
    • pp.102-112
    • /
    • 1996
  • The precious serpentine, referring to a rare and highly valuable gem variety of serpentine group minerals, is found to occur in serpentinite from Booyo Gren Jade Mine which is located in Oesan-myun, Booyo-gun of Chungchungnam-do. Geommological properties of the precious serpentine have been investigated by use of polarizing microscope, specific gravity balance, refractometer, hardness pencils, X-ray diffractometer, XRF, ICP-MS analyser, and infrared absorption spectroscope.The precious serpentine from Booyo is colored deep green with oily luster and semi-transparent. It is highly tough and Mohs's scale of hardness is measured to be 5-6. Specific gravity is determined to be 2.67, and a single refractive index ND=1.56 is observed by a spot method, using sodium light source. X-ray powder diffraction data is represented by the reflection lines at 7.40(100), 4.64(25), 3.68(68), 2.757(69), 2.530(49), 2.549(32), and 1.710(21${\AA}$), which compares very well with that of antigorite of serpentine group minerals. The major chemical compositions of the precious serpentine group minerals. The major chemical compositions of the precious serpentine are SiO2 42.49%, MgO 39.08%, Fe2O3 3.85%, and H2O 11.87%. Besides, trace elements such as Cr(2188), Ni(1110ppm), Co(58ppm), and Ta (108ppm) are relatively spectrum shows peaks at 3670, 1190, 1070, 980 and 610cm-1. Strong absorption at 3670cm-1 is due to OH stretching, and 1190, 1070 and 980cm-1 due to SiO stretching. The absorption 610cm-1 is formed by alteration of pre-existing ultramafic rock, namely peridotite, with an introduction of fluid with very little content of CO2, under 400$^{\circ}C$ environment. Magnetite inclusions, finely disseminated in the precious serpentine, may be a result of Fe precipitation, during serpentinization of olivine-bearing country rock.

  • PDF

마우스 공간지각과 기억 형성에 미치는 전정 유래 정보의 규명 (Identification of Vestibular Organ Originated Information on Spatial Memory in Mice)

  • 한규철;김민범;김미주
    • Research in Vestibular Science
    • /
    • 제17권4호
    • /
    • pp.134-141
    • /
    • 2018
  • Objectives: We aimed to study the role of vestibular input on spatial memory performance in mice that had undergone bilateral surgical labyrinthectomy, semicircular canal (SCC) occlusion and 4G hypergravity exposure. Methods: Twelve to 16 weeks old ICR mice (n=30) were used for the experiment. The experimental group divided into 3 groups. One group had undergone bilateral chemical labyrinthectomy, and the other group had performed SCC occlusion surgery, and the last group was exposed to 4G hypergravity for 2 weeks. The movement of mice was recorded using camera in Y maze which had 3 radial arms (35 cm long, 7 cm high, 10 cm wide). We counted the number of visiting arms and analyzed the information of arm selection using program we developed before and after procedure. Results: The bilateral labyrinthectomy group which semicircular canal and otolithic function was impaired showed low behavioral performance and spacial memory. The semicircular canal occlusion with $CO_2$ laser group which only semicircular canal function was impaired showed no difference in performance activity and spatial memory. However the hypergravity exposure group in which only otolithic function impaired showed spatial memory function was affected but the behavioral performance was spared. The impairment of spatial memory recovered after a few days after exposure in hypergravity group. Conclusions: This spatial memory function was affected by bilateral vestibular loss. Space-related information processing seems to be determined by otolithic organ information rather than semicircular canals. Due to otolithic function impairment, spatial learning was impaired after exposure to gravity changes in animals and this impaired performance was compensated after normal gravity exposure.