Browse > Article

Improvement of hot work environment in the curing processes of a tire manufacturing company  

Lim, Jung-ho (Department of Environmental Engineering, Changwon National University)
Kim, Tae-Hyeung (Department of Environmental Engineering, Changwon National University)
Publication Information
Journal of Korean Society of Occupational and Environmental Hygiene / v.21, no.1, 2011 , pp. 1-10 More about this Journal
Abstract
Generally, the tire curing process is the process in which the sulfur is added and subsequently the tire is heated to give the tire elasticity. In this process, all kinds of the chemicals in the tire are emitted with a lot of heat. The chemical fume and heat aggravate the work environment. To solve this problem, 92 local exhaust ventilators and 8 gravity ventilators were used, but not satisfactory yet. Preliminary survey showed that the temperatures in the process were very high: 30.3, 32.9 and $37.2^{\circ}C$ at 2, 4 and 6m above the ground level, respectively in the winter (outside temperature was $2^{\circ}C$). It can be imagined that the process is severely hot in the summer time. The higher temperature distribution in the higher space tells us that the hot plume could not be removed with the existing ventilation systems. Therefore, in this study, some alternative ventilation systems were designed. The partitions were used to contain the hot plume to increase the capture efficiency. The gravity ventilators were newly designed to improve the extraction efficiency of hot fume. To satisfy the balance of pressure in the curing process, some supply air system was introduced by renewing the existing air conditioning system. Many alternative solutions were evaluated by using computational fluid dynamics modelling. The best and applicable solution was selected and the existing ventilation system was modified. After implementing the new ventilation system, the hot environment was much improved. The temperature reduction in the curing process was about $6.4^{\circ}C$.
Keywords
Tire manufacture; Thermal state; CFD;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 하현철, 김태형. 자연환기 벤틸레이터 형태에 따른 환기효율 평가. 설비공학논문집 2002; 14:543-551
2 정유진. 자연환기 벤틸레이터 최적화 설계에 관한 기초연구. 창원대학교 석사학위 논문 2002; 2-3
3 한국산업안전공단 산업안전보건연구원. 한국타이어(주) 역학조사 최종결과 발표. 2008.
4 McMichael A. J., Andjelkovic D. A., Tyroler H., A. Cancer mortality among rubber worker: an epidemiologic study. Ann N. Y. Acad. Sci. 1976;271:25-37
5 Kogevinas M., Sala M., Boffetta P. et. Cancer risk in the rubber industry: a review off the recent epidemiological evidence. Occup. Environ Med. 1998;55(1):1-12   DOI   ScienceOn
6 Kulmala I. Advanced design of Local Ventilation Systems. Finland: VTT Publications; 1997.p.1/1-1/17.
7 Hualtieri M., Rigamonti L., Galeotti V., Camatini M., Toxicity of tire debris extracts on human lung cell line A549. Toxicol. In. Vitro. 2005;19(7):1-8   DOI