• Title/Summary/Keyword: Gravimetric method

Search Result 209, Processing Time 0.028 seconds

Correction Factors for Outdoor Concentrations of PM2.5 Measured with Portable Real-time Monitors Compared with Gravimetric Methods: Results from South Korea

  • Yun, Dong-Min;Kim, Myeong-Bok;Lee, Jun-Bok;Kim, Bo-Kyeong;Lee, Dong-Jae;Lee, Seon-Yeub;Yu, Sol;Kim, Sung-Roul
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1559-1567
    • /
    • 2015
  • This study investigated the association between $PM_{2.5}$ concentrations obtained with portable real-time monitors and those obtained with gravimetric methods in national urban air-quality monitoring sites in Seoul, South Korea. We used the SidePak AM510 Personal Aerosol Monitor (TSI Inc., 500 Cardigan Road Shoreview, MN) and DustTrak DRX 8533 (TSI Inc., 500 Cardigan Road Shoreview, MN) as portable real-time monitors for measuring $PM_{2.5}$ concentrations and compared these values with those measured with the PMS-103 or SEQ 47/50 models operated by Federal Reference Method (FRM) or the European Committee for Standardization(ECS), respectively, in national urban air-quality monitoring sites in Seoul. Measurements were conducted every other day in the winter and spring seasons of 2014. The estimated daily mean concentrations of $PM_{2.5}$ ranged between 13.4 and $161.9{\mu}g/m^3$ using AM 510 and between 22.0 and $156.0{\mu}g/m^3$ using DustTrak. The Spearman correlation coefficient for $PM_{2.5}$ concentrations between AM 510 and gravimetric results was 0.99, and the correlation between DustTrak and gravimetric results was 0.87. The correction factor suggested was 0.42 and 0.29 for AM 510 and DustTrak, respectively. We found that $PM_{2.5}$ concentrations measured with real-time monitors could overestimate true $PM_{2.5}$ concentrations and therefore the application of a correction factor (0.43) is strongly suggested for quantification when Real-time monitors were operated of $PM_{2.5}$ levels at urban atmospheric environment of South Korea.

Estimation of PM2.5 Correction Factor for Optical Particle Counter in Ambient Air (대기환경에서 광산란 미세먼지 측정기의 PM2.5 보정계수 산정)

  • Kim, Jong Bum;Kim, Danbi;Noh, Sujin;Yoon, Kwan Hoon;Park, Duckshin;Lee, Jeong Joo;Kim, Jeongho
    • Particle and aerosol research
    • /
    • v.16 no.2
    • /
    • pp.49-59
    • /
    • 2020
  • Various devices have been developed to the measurement of particulate matter pollutants, and Optical Particle Counter (OPC) that can be easily and quickly measured is widely used lately. The measured value by OPC is converted to weight concentration using the correction factor (CF). The calculation of CF is very important to improve the reliability and accuracy of OPC. In this study, the CF calculation study of light scattering laser photometer (model 8533, TSI) was carried out to measure in the atmospheric environment using 2 gravimetric devices and 3 light scattering laser photometer devices. Regression analysis and Tukey tests were used to significance the test of measurement devices. Measurements were carried out twice. There was a comparative analysis of measurement data between light scattering laser photometer and gravimetric devices in 1st measurement, and then the Evaluation of PM2.5 concentration corrected by CF performed in 2nd measurement. As a result of the significance analysis between light scattering laser photometer and gravimetric devices, the correlation between the same method was high, but the correlation between different methods was low. CF was calculated as 0.4258 based on the measurement results, and it is a similar level to previous studies at home and abroad. It is expected that these results can be used as basic data in the future study for air quality measurement research using light scattering laser photometer. Also, in order to improve the accuracy of the measurement techniques and the development of technology in the atmospheric environment, CF calculation research should be conducted continuously.

Relationships between TSP and PM10 Concentrations in the Ambient Atmosphere (대기 중 TSP와 PM10 농도의 관련성)

  • 최진수;백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 1998
  • Relationships between TSP and PM10 concentrations were evaluated using their respective data sets collected from Taegu and Kyeungsan areas during the period of December 1993 to November 1994. The collection of data was made using the gravimetric and $\beta$-ray absorption ($\beta$-MPM) methods for 7 days of every month from three urban sites in Taegu and one suburban site in Kyeungsan. Correlation coefficients between TSP and PM10 concentrations for these four sampling sites were found in the range of 0.85 $\sim$ 0.96. Correlation analysis was also conducted for $\beta$-PM concentration data that were measured only from the residential and commercial sites. The correlation coefficients between TSP and $\beta$-PM concentrations were 0.9 in the residential site and 0.8 in the commercial site. By contrast, the correlation coefficients between PM10 $\beta$-PM concentrations were almost identical for both the residential and commercial sites with a value of 0.88. The mean ratio for PM10 to TSP concentrations for all sites was appeared to be 0.68. The analysis of seasonal trends in PM10/TSP ratios showed that the contribution of PM10 to TSP concentrations was more significant during winter (0.70 $\sim$ 0.75) than during summer (0.61 $\sim$ 0.68). The results of this study may provide empirical informations on the compatability of aerosol data measured by different sampling methods.

  • PDF

An Experimental Study on the Emission Characteristics of Smoke from the Marine Four-Stroke Diesel Engines Operated in Constant Speed and Various Load Steps (선박용 4행정 디젤엔진의 정속 부하변동 운전시 매연배출특성에 대한 실험연구)

  • Oh, Sang-Hoon;Kim, Jae-Min;Kim, Hyun-Kyu;Yoo, Bong-Whan
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.19-20
    • /
    • 2006
  • The emission of particulate matter from marine diesel engines is already restricted by regional regulations in some countries, and IMO has been preparing the regulation for particulate matter from 53rd MEPC. But confusingly, the gravimetric PM measurement methods and procedures are not established clearly yet. On the other hand, smoke measurement method is set clearly, and it can also indicate PM, though it is not direct gravimetric method. As the preparing step for regulations about PM, we measured the smote density of exhaust emission from the marine four-stroke diesel engines operated in constant speed and various load steps on the test-bed, using the filter-type smoke measuring instrument. As a result, we understood the omission characteristics of smoke from the engines. Additionally, to obtain the objective reliability of our measurement data, we carried out experimental studies about various measuring parameters that could affect the smoke density.

  • PDF

An Experimental Study on Measurement of the Reaction Order of a Liquid Fuel with Various Components (혼합 액체연료의 화학반응차수 계측에 관한 실험적 연구)

  • Choi, Hyo-Hyun;Lim, Jun-Seok;Kim, Chul-Jin;Sohn, Chae-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.421-424
    • /
    • 2011
  • Thermal Analyses are conducted to measure various factors of a liquid fuel required for numerical analysis. Thermal Analyses are divided into two different methods of TGA (Thermo Gravimetric Analysis) and DSC (Differential Scanning Calorimetry). Non-isothermal experimental results are analyzed using by TGA. The results are filtered by a Freeman Carroll method. At the same time, chemical parameters of unknown liquid fuel, activation temperature and reaction order are measured to 6128.2 K and 1.4, respectively. Furthermore, the parameters can be obtained by various mathematical methods. It is found that tha parameters depend on the processing method.

  • PDF

A Prediction of Remaining Service Life of Concrete for Irrigation Structure by Measuring Carbonation (중성화 측정을 통한 콘크리트의 잔존수명 예측)

  • 이준구;박광수;신수균;김관호;윤성수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.773-778
    • /
    • 2002
  • The variance characteristics of the calcium carbonate contents along to the concrete cover depth takes the prediction method of remaining service life of concrete. Calcium carbonate contents were measured by the Thermo Gravimetric/Differential Thermal Analysis method at three point, depth of 0.25cm, 0.75cm, 1.25cm from the surface of concrete. This prediction method contain some assumption that the chemical protection conferred on steel is through a passive protective oxide film which forms on steel in an environment at or above a pH of 10.5$^{4)}$ .

  • PDF

Studies on the Formation of Copper Complexes of Sulfa-Drug II.Study on Chemical Constisuent of Copper Sulfa-Drug Complex by Continuous Variation Method. (Sulfa제-Cu착화합물의 형성에 관하여 II Spectrophotometry 에 의한 Copper Sulfa-Drug Complex 의 화학조성결정)

  • 이왕규
    • YAKHAK HOEJI
    • /
    • v.8 no.4
    • /
    • pp.96-99
    • /
    • 1964
  • In the previous study, the composition ratios of the Cu-sulfa drugs complexes determined by gravimetric and solvent extraction method reported. In this paper, the continuous variations method has been used to know whether the complexes are simple complexes or chelates, and to recertify the composition ratios of the complexes at pH 7-8. It has been certified that the ratio of $Cu^{+2}$ ion to sulfa drugs in 1:2 from the result of this experiment.

  • PDF

Quantitative Analysis of Silicone Oil in Antifoaming Agent (소포제중 실리콘 오일의 함량에 대한 분석)

  • Kim, Kyeong Sook;Yang, Seug Ran;LIm, Chun Sik;Park, Hyun Joo
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.4
    • /
    • pp.337-342
    • /
    • 2000
  • Many kinds of experiments were performed for the quality control of antifoaming agents used in thermal power pIants of KEPCO. We tried to establish more convenient ans more accurate quantitative analytical method to determine the amount of silicone oil in silicone oil type antifoaming agent regardless of the amount and/or the type of involved surface active agents. First, the amount of silicone oil was measured by gravimetric method or centrifugal method using very simple apparatus, and then was compared to the results of FT-lR spectroscopy. The centrifugal method was turned out a poor method depending upon the recovery test and virtual experiments. Some antifoaming agents showed very similar results between gravimetric method and spectroscopic methods, and the others gave very different results. We concluded that FT-lR spectroscopy is the most convenient and reliable methodto determine the amounts of silicone oil in the antifoaming agents.

  • PDF

Studies on the formation of Copper Compelxes of Sulfa-Drug. (Sulfa제-Cu 착화합물의 형성에 관하여)

  • 이왕규
    • YAKHAK HOEJI
    • /
    • v.7 no.1
    • /
    • pp.13-17
    • /
    • 1963
  • The purpose of this work is to investigate the molar ratio, the precipitation condition and the color of copper sulfa-drugs complexes. The colors of the complexes are observed at every precipitation condition is obtained as pH 7-9. The determination of the molar ratio of complexes is able to be carried out by way of gravimetric method and solvent extraction method. The molar ratios of sulfa-drugs and copper in identified complexes are 2:1 when utilizing both methods.

  • PDF