• Title/Summary/Keyword: Graft

Search Result 3,681, Processing Time 0.031 seconds

Study on the Preparation of Alginic Acid-PMMA Graft Polymer and the Surface Modification of Montmorillonite with the Graft Polymer (Alginic Acid-PMMA Graft Polymer의 합성 및 이를 Coupling제로 한 Montmorillonite 표면의 개질화에 관한 연구)

  • 손차호;김경환;박천욱
    • Textile Coloration and Finishing
    • /
    • v.4 no.4
    • /
    • pp.81-89
    • /
    • 1992
  • Graft polymers of alginic acid-PMMA, different in composition and Mv of branched PMMA, were prepared by emulsion graft polymerization at various MMA concentrations. In aqueous dispersion solution, the adsorption of graft polymer on the montmorillonite was carried out to modify the surface property of powder, and the adsorption of PMMA in organic solvents (acetone, benzene) on the modified surface of powder were observed. The results obtained were as follows. 1. In emulsion graft polymerization of MMA on the sodium alginate in aqueous solution, SA conversion, MMA conversion and % grafting were increased with increasing MMA concentration where as graft efficiency was decreased. 2. The adsorption amount of graft polymer was increased with the elevation of temperature and the increased of dispersion concentration and with the increase of branched PMMA composition of graft polymer. 3. In organic solvent, the adsorption of PMMA on the surface modified particle was proceeded by the orientation along the stretched branched PMMA of adsorbed graft polymer which is in radial direction to the particle surface. 4. The adsorbed amount of PMMA was increased as the temperature and concentration of PMMA solution, the branching of adsorbed graft polymer and the solvency of solvent were increased.

  • PDF

Bacterial infections after implant surgery and alveolar bone graft (임플란트 및 골이식술과 관련된 세균감염)

  • Paeng, Jun-Young
    • The Journal of the Korean dental association
    • /
    • v.53 no.5
    • /
    • pp.298-306
    • /
    • 2015
  • Bacterial infection after implant installation or bone graft is a serious complication. Bone grafts represent a temporary foreign body lacking vascularisation and are therefore of increased susceptibility to infection, which may be introduced either intraoperatively or postoperatively. Bone graft-associated infections are due to biofilm formation on the surface of the bone graft and often require removal of the infected bone graft with substantial graft failure. In this review, the implant and graft related infection, the role of biofilm and the management will be discussed.

Graft Length of the Bone-patellar Tendon-bone for Reconstruction of ACL (골-슬개건-골을 이용한 전방십자인대 재건술에서 이식물의 길이)

  • Kim, Jung-Man
    • Journal of the Korean Arthroscopy Society
    • /
    • v.1 no.1
    • /
    • pp.55-62
    • /
    • 1997
  • Various surgical techniques has been advocated for reconstruction of anterior cruciate ligament using the bone-patella tendon-bone graft. Recently endoscopic technique provides good clinical results, with minimal skin incision, accurate positioning of the graft to the femoral tunnel, and decreasing wear rate of the graft. But the graft-tunnel mismatch remains problematic in endoscopic technique. The purpose of this paper is to described causes of the graft-tunnel mismatch and to provide important steps to prevent or minimize the graft-runnel mismatch following anterior cruciate ligament while using the endoscopic technique. Our guideline for prevention of the graft-tunnel mismatch are as follows: (1) The tunnel should he positioned closely to isometric point as much as possible. (2) Anterior placement of the tunnel should be avoided. (3) The change of graft length should be within 2mm between flexion and extension position.

  • PDF

Comparison Study Between Coverage Choices for Radial Forearm Free Flap Donor Site (전완유리피판 공여부 재건에서 전층 피부이식술과 부분층 피부이식술의 비교)

  • Jeong, Woo Shik;Choi, Jong Woo;Oh, Tae Suk
    • Korean Journal of Head & Neck Oncology
    • /
    • v.31 no.1
    • /
    • pp.5-8
    • /
    • 2015
  • Backgrounds: The purpose of this study was to compare full thickness skin graft with inguinal skin to split thickness skin graft for coverage of the radial forearm free flap donor site. Patients and Methods: 25 patients who was reconstructed with radial forearm free flap for head and neck cancer were reviewed retrospectively. Results: The graft loss rates of full thickness skin graft were less than split thickness skin graft or split thickness skin graft with dermal substitutes. The recovery times of donor site and skin graft donor site of full thickness skin graft were also shorter than split thickness skin graft or split thickness skin graft with dermal substitutes. Skin texture and aesthetic results of donor site were improved and complications as itching and pain sensation were decreased. Conclusion: Full thickness skin grafts with inguinal skin should be considered for patients requiring a radial forearm free flap.

  • PDF

The Effect of Graft using Acrylic Acid on the Detergency for the Nylon 6 Fabric -Improvement of Hemoglobin Removing Rate on Grafted Nylon- (나일론 6 직물의 아크릴산 그라프트 중합과 그라프트 나일론의 세척성 -그라프트 나일론 직물의 헤모글라빈 오구 세척성 향상-)

  • 오수민;김인영;송화순
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.7
    • /
    • pp.1064-1072
    • /
    • 1999
  • Nylon fabric was grafted for the purpose of the development of detergency against the hemoglobin as a protein soil. By free-radical producing chemical initiator systems the graft using acrylic acid(AA) as a hydrophilic vinyl monomer was performed to change surface energies in the presence of ammonium persulfate(APS) as an initiator and then acrylic acid grafted Nylon was treated with NaOH solution. The surface morphology for Nylon-g-NaAA with changing graft rate were studied by scanning electron microscopy (SEM) The properties of the Nylon such as diameter tenacity elongation contact angle and the hemoglobin removal were also investigated. The diameter of grafted Nylon fiber increased as the graft ratio increased. The tenacity of grafted Nylon also increased with increasing graft ratio up to 15% The elongation however decreased gradually according to graft, The contact angle decreased after graft and alkaline treatment. The amount of hemoglobin on the grafted Nylon increased in proportion to the graft ratio. Hemoglobin was easily removed from grafted Nylon while it was difficult to be removed from ungrafted Nylon. The detergency of hemoglobin for grafted Nylon decreased when the graft ratio exceeded 15% The removal of hemoglobin increased markedly with increasing hemoglobin content and revolution speed. Therefore the removal of hemoglobin was improved due to graft and alkaline treatment.

  • PDF

Graft-taking Characteristics of Watermelon Grafted Seedlings as Affected by Blue, Red and Far-red Light-emitting Diodes (수박 접목묘의 활착 특성에 미치는 청색, 적색 및 원적색 발광다이오드의 영향)

  • 김용현;박현수
    • Journal of Biosystems Engineering
    • /
    • v.28 no.2
    • /
    • pp.151-156
    • /
    • 2003
  • This study was performed to investigate the effect of light quality on evapotranspiration and graft-taking characteristics of watermelon grafted seedlings using blue, red and far-red light-emitting diodes (LED). At initial stage of graft-taking, blue light increased the evapotranspiration rate (EVTR) of grafted seedlings as compared to effects of red and far-red on EVTR of grafted seedlings. Grafted seedlings graft-taken under red and blue LED showed the high graft-taking of 100% and 96%, respectively. However, grafted seedlings graft-taken under far-red LED showed the graft-taking of 80% and survival of 60% with low seedlings quality after hardening. The stem of grafted seedlings graft-taken under red light was elongated but blue light suppressed the stem elongation. The leaf area of grafted seedlings graft-taken under red light was increased. It is concluded that the effect of light quality using LED on graft-taking of watermelon grafted seedlings was significantly recognized. Considering the duration of quality of grafted seedlings graft-taken under artificial lighting, LED could be used as an effective lighting sources to validate the continuance of seedling quality.

Familial Tooth Bone Graft: Case Reports (가족치아를 이용한 골이식술: 증례보고)

  • Lee, Ji-Young;Kim, Young-Kyun;Um, In-Woong;Choi, Joon-Ho
    • The Journal of the Korean dental association
    • /
    • v.51 no.8
    • /
    • pp.459-467
    • /
    • 2013
  • The use of autogenous tooth bone graft material has been commercialized since 2008. Autogenous tooth bone grafts always require that the tooth of the patient be extracted, and thus, the use of graft material are limited in many cases. For solution of limitation in quantity and concurrent use of autogenous tooth bone graft material, the grafting of familial teeth has been suggested. It has the following advantages: the teeth of family members are used as bone graft materials, the genetic composition is identical, and potential genetic and infectious risks can be minimized. Because the teeth of family members are used, a good tissue affinity is obtained, and thus, superior bone generation rates compared to those observed for allogenic or xenogenic bones can be anticipated. We used familial tooth bone-graft materials for alveolar ridge augmentation, socket preservation, and maxillary sinus graft in some cases. In most cases, the impacted third molars of their children were prepared as bone graft material and were used for surgery. In one case, the impacted third molar from the patient's brother was used as bone graft material. We obtained satisfactory result and these cases are reported herein.

Radiographic evaluation of infra-bony defects treated by bone graft procedures (골 이식술에 의해 치료된 골연하 결손부의 방사선학적 변화 양상의 관찰)

  • Ryu, Sang-Ho;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.437-444
    • /
    • 2008
  • Purpose: A number of techniques and materials have been used for periodontal regeneration and bone graft procedures with guided tissue regeneration(GTR) have been suggested as alternatives to osseous surgery in the management of local infra-bony defects. However, the long-term stability and treatment outcome following bone graft procedure of infra-bony defects is poorly documented. The purpose of this study was to assess radiographic change in infra-bony defects over 2 years after bone graft procedures with various graft materials. Material and Methods: Patients attending the department of periodontics of Kyungpook National University Hospital were studied. Patients showed clinical and radiographic evidence of infra-bony defect(s). 44 sites of 34 patients aged 31 to 69 (mean age 48.3) were treated by bone graft procedure with a bone graft material. Baseline and 2-year follow-up radiographs were collected and evaluated for this study. Radiographic assessment includes a bone fill, bone crest change, defect resolution, and % of defect resolution. Pre- and post-treatment differences between variables (maxilla and mandible, defect depth, defect angle, bone graft materials) using the paired t-test were examined. Result: We observed $1.15{\pm}1.95\;mm$ of bone fill, $0.40{\pm}1.19\;mm$ of crestal resorption, $1.55{\pm}1.77\;mm$ of defect resolution, and $40{\pm}44%$ of percentage of defect resolution. Deeper initial defect depth, narrower initial defect angle showed significantly greater bone fill, defect resolution, and % of defect resolution. But no significant difference was observed in graft sites and graft materials. Conclusion: If good oral hygiene maintenance and periodic recall check of patients is assured, bone graft procedure using various graft materials is one of the appropriate treatment modality for regenerative therapy of infra-bony defects.

Great Toe Pulp Graft for the Reconstruction of the Postburn Flexion Contracture in the Fingers (수지 화상 후 굴곡성 구축 치료 시 족질부 이식)

  • Seo, Je Won;Kwon, Ho;Yim, Young Min;Jung, Sung-No
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.587-592
    • /
    • 2007
  • Purpose: In case of postburn flexion contracture of the fingers, skin graft, geometrical relaxation techniques, local flap, and free flap have been used. Among these procedures, full-thickness skin grafts from the inguinal area are widely used to reconstruct a postburn flexion contracture in the fingers. But there are many esthetic and functional problems in this procedure. Especially, hyperpigmentation of the skin-grafted fingers poses a troublesome problem, particularly in the patients who have dark colored skin. To solve the problem, we have used pulp graft which was harvested from the lateral aspect of great toe. In the present study, we report pulp graft, with which we have obtained a good result in the treatment of postburn flexion contracture of the fingers. Methods: Between September of 2004 and August of 2006, great toe pulp graft was performed to 20 sites of 15 patients. After release of the postburn flexion contracture using Z-plasty, the composite tissue (pulp) harvested from the lateral aspect of great toe was grafted on the raw surface. Moisture dressing with ointment and foam dressing material was performed. Stratum corneum of the graft got stripped off in two to four weeks after pulp graft. The color of the pulp graft was slightly reddish, then it became similar to the adjacent tissue. Results: There was complete take in all the patients who were treated with pulp graft. Great toe pulp graft provided similar color and texture to the adjacent skin, high rate of graft take, and left only a minimal scar at donor site. Conclusion: Thick keratin layer and inelastic nature of the pulp make this type of the graft much easier and simpler, and ensure a better take. Pulp graft is useful method for the reconstruction of the postburn flexion contracture in fingers.

Alveolar Cleft Reconstruction Using Chin Bone and Autogenous Tooth Bone Graft Material: Reports of 5 Cases

  • Jeong, Kyung-In;Lee, Junho;Kim, Kyung-Wook;Um, In-Woong;Hara, Shingo;Mitsugi, Masaharu;Kim, Young-Kyun
    • Journal of Korean Dental Science
    • /
    • v.6 no.1
    • /
    • pp.13-21
    • /
    • 2013
  • Purpose: To report the successful results of using chin bone graft and autogenous tooth bone graft material (AutoBT) in alveolar cleft patients. Materials and Methods: Five patients with alveolar cleft defects underwent alveolar bone grafting. Three patients were treated using chin bone graft, and the other two patients underwent AutoBT graft. After implant site development using chin bone graft in the fi rst three cases, endosseous implant restorations were placed. In case #4 and 5, AutoBT graft material was placed to guide the normal eruption of partially impacted maxillary right canine and to the upper docking site after distraction osteogenesis. Result: Successful implant restorations with closure of the oronasal fistula were achieved in alveolar cleft defect reconstruction using either chin bone graft (Case #1, 2, 3) or AutoBT graft material (Case #4, 5). Case #4 showed enlarged follicle of the right maxillary canine, indicating a normal eruption guide pattern. Conclusion: Both chin bone graft and AutoBT graft showed favorable outcomes in reconstructing alveolar cleft defects. Autogenous tooth bone graft opens up the possibility of avoiding harvesting autogenous bone graft with complications and morbidities.