• Title/Summary/Keyword: Gradient Grade

Search Result 64, Processing Time 0.02 seconds

Association of Carotid Intraplaque Hemorrhage and Territorial Acute Infarction in Patients with Acute Neurological Symptoms Using Carotid Magnetization-Prepared Rapid Acquisition with Gradient-Echo

  • Park, Jung Soo;Kwak, Hyo Sung;Lee, Jong Myong;Koh, Eun Jeong;Chung, Gyung Ho;Hwang, Seung Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.2
    • /
    • pp.94-99
    • /
    • 2015
  • Objective : The purpose of our study was to assess prevalence of carotid intraplaque hemorrhage (IPH) and associations between territorial acute infarction and IPH on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) in patients with acute neurologic symptoms. Methods : 83 patients with suspected acute neurologic symptoms were evaluated with both brain diffusion weighted imaging (DWI) and carotid MPRAGE sequences. Carotid plaque with high signal intensity on MPRAGE of >200% that of adjacent muscle was categorized as IPH. We analyzed the prevalence of IPH and its correlation with territorial acute infarction. Results : Of 166 arteries, 39 had a carotid artery plaque. Of these arteries, 26 had carotid artery stenosis less than 50%. In all carotid arteries, MR-depicted IPH was found in 7.2% (12/166). High-signal intensity on DWI was found in 17.5% (29/166). Combined lesion with ipsilateral high-signal intensity on DWI and IPH on carotid MPRAGE sequence was found in 6 lesions (6/166, 3.6%). Of patients with carotid artery plaque, MR-predicted IPH was found in 30.8% (12/39) and match lesions with high-signal intensity on DWI and MPRAGE was found in 15.4% (6/39). MR-predicted IPH was significantly higher prevalence in high-grade stenosis group (p=0.010). Relative risk between carotid MPRAGE-positive signal and ipsilateral high-signal intensity on DWI in arteries with carotid artery plaques was 6.8 (p=0.010). Conclusion : Carotid MPRAGE-positive signal in patients was associated with an increased risk of territorial acute infarction as detected objectively by brain DWI. The relative risk of stroke was increased in high-grade stenosis categories.

Growth of Low Defect Piezo-quartz and Defect Analysis (저결함 압전수정의 성장과 결함분석)

  • Lee Young Kuk;Bak Ro Hak
    • Korean Journal of Crystallography
    • /
    • v.8 no.1
    • /
    • pp.26-32
    • /
    • 1997
  • Quartz single crystals were grown hydrothermally and growth defects such as dislocations, etch channels and impurities were examined. Growth rates were 0.25-0.65 mm/day under the growth conditions of following. 1. Mineralizer: $4wt.\%$ NaOH. 2. Growth temperature: $340-360^{\circ}C$. 3. Temperature gradient: $20-40^{\circ}C$. 4. Seed: ZY plate. 5. Nutrient: synthetic quartz. Defects of the quartz which was grown with optical grade synthetic nutrient, low dislocation density seed and horizontal seed setting technique were as follows. 1. Dislocation density: 20.0 each/$cm^2$. 2. Etch channel density: 5.0 each/$cm^2$ (1st grade by IEC 758 standard). 3. Impurity (larger than 10$\mu$) concentration: 2.4 each/$cm^3$ (Ia grade by IEC 758 standard). 4. Alpha value: 0.019 (A grade by IEC 758 standard).

  • PDF

The Characteristic Refinement of Poly-Si by Uni-directional Solidification with Thermal Gradient (일방향 응고시 온도 구배에 의한 다결정 실리콘 정련 특성)

  • Jang, Eunsu;Yu, Joon-Il;Park, Dongho;Moon, Byungmoon;Yu, Tae U
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.59.2-59.2
    • /
    • 2010
  • 결정형 태양 전지의 보급화를 위하여 고순도 실리콘을 저렴하게 제조할 수 있는 기술 개발이 필요하다. 본 연구에서는 고순도 실리콘을 경제적으로 제조하기 위하여 대역 정제에 의한 일방향성 응고법을 이용한 정련 연구를 진행하였으며, 응고 속도와 고 액상의 온도 구배가 정련도에 미치는 영향을 분석 하였다. 본 실험에 사용된 일방향 응고장치는 실리콘 용탕이 장입된 도가니 하부의 열 교환기를 통한 냉각에 의해 용탕 하부에서 상부 방향으로의 일방향성 응고가 진행되며, 응고 진행시 용탕의 흔들림에 의한 정련능의 감소를 방지하기 위해 가열 영역이 이동하는 Stober 공정을 채택하였다. 가열 영역은 실리콘 용융을 위한 상부 가열 영역과 응고 진행시 응고부의 온도 제어를 위한 하부 가열 영역으로 구성되어 있으며, 두 가열 영역의 온도 제어를 통해 응고중인 실리콘의 고 액상의 온도 구배를 조절하였다. 일방향 응고에 의한 정련법에서 고 액상의 온도 구배가 증가할수록 2차 수지상의 발달이 감소하고, 주상정의 수지상 형태를 유지하게 되어 고 액 공존영역에서 액상 영역으로의 확산이 원활하게 이루어져 분배계수를 이용한 정련도가 좋아지게 되며, ICP 분석을 통해 온도 구배의 증가에 따라 정련능이 증가하는 양상을 확인 할 수 있었다. 고 액상의 온도 구배의 조절을 통한 공정 시간 대비 정련도의 향상을 통해 결정형 태양전지의 생산성의 증가를 통한 저가화를 이룰 수 있을 것이다.

  • PDF

Structure and Characteristics of Diffusion Flaame behind a Bluff-body in a Divergent Flow(II) (확대유로내의 Bluff-Body 후류확산화염의 구조 및 특성 2)

  • ;;Lee, Joong Sung
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.11
    • /
    • pp.2981-2994
    • /
    • 1995
  • In order to elucidate the effects of positive pressure gradient on flame properties, structure and stabilization, an experimental study is made on turbulent diffusion flame stabilized by a circular cylinder in a divergent duct flow. A commercial grade gaseous propane is injected from two slits on the rod as fuel. In this paper, stabilization, characteristics and flame structure are examined by varying the divergent angle of duct. Temperature, ion current and Schlieren photographs were measured. It is found that critical divergent angle is expected to be about 8 ~ 12 degree through blow-off velocity pattern to divergent angle and the positive pressure gradient influences the flame temperature, intensity of ion current and eddy structure behind the rod. With the increase of divergent angle, typical temperature of recirculation zone is low but intensity of ion current is high in shear layer behind rod. Energy distributions of fluctuating temperature and ion current signals turn up low frequency corresponding to large scale eddies but high frequency corresponding to small scale eddies as well as low with the increase of divergent angle. Therefore the flame structure becomes a typical distributed-reacting flame.

Discrete Membranous Subaortic Stenosis (대동맥판막하 막상협착증 치험 2례)

  • 문경훈
    • Journal of Chest Surgery
    • /
    • v.21 no.4
    • /
    • pp.727-733
    • /
    • 1988
  • Two cases of the discrete membranous subaortic stenosis were experienced at the Department of Thoracic & Cardiovascular Surgery, National Medical Center, Seoul, Korea. Case I was 31 years old male with a history of aortic valve replacement[Ionescu-Shiley, 19mm] at the other hospital in 1980. Heart failure was noticed 6 years later. On cardiac catheterization, pressure gradient between left ventricle 4 aorta was 104 mmHg, but subvalvular aortic stenosis was not detected by preoperative 2-D echo <% left ventriculogram. Above case revealed stenoinsufficiency of the prosthetic valve. Under the diagnosis of the prosthetic valve failure, re-do aortic valve replacement[Bjork-Shiley, 23 mm] was done. During operation, the discrete membranous subaortic stenosis was incidentally found, and it was completely resected. So we thought that above discrete membranous subaortic stenosis was not detected at first operation, and it was progressed during 6 years, and accelerated the degeneration of the prosthetic valve. Case II was 20 years old female. Her complaints were exertional dyspnea, angina, syncope, which were aggravated since 5 years ago. 2-D echo <% left ventriculogram revealed the discrete membranous subaortic stenosis. Pressure gradient was 20 mmHg, but her symptoms were serious. Associated cardiac anomaly was the persistent left superior vena cava without connection with right superior vena cava. Complete excision of the membranous tissue was done. Post-operative pressure gradient between left ventricle & aorta was absent, and her complaints were nearly subsided. Both cases were type I according to the Newfeld classification of the discrete subvalvular aortic stenosis, and complete excision of the membranous tissue was done without myotomy or mymectomy. And short-term follow-up results[Case I:2 years, Case II: 1 ~ years] were good except soft systolic murmur[grade II/VI] at the aortic area in both cases.

  • PDF

A Study on the Flame Structure and Stabilization in a Divergent Flow (확대관 흐름에 있어서 화염의 안정성 및 구조에 관한 연구)

  • 최병륜;이중성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.512-518
    • /
    • 1994
  • An experimental study is made on turbulent diffusion flames stabilized by a circular cylinder in a divergence flow. In this paper, stabilization characteristics and flame structure are examined by varying the divergence angle of duct and position of a circular cylinder. The fuel used is a commercial grade gaseous propane injected by two slit of rod. It is found that the positive pressure gradient greatly influences the eddy structure behind the rod. and that two different kinds of combustion patterns exist at the blowoff limit depending on the divergent angle of duct. They are distinguished by their wake structures: one associated with Karman vortex shedding, the other without it. Also, the blowoff velocity in the former is found to be higher than in the later.

Analysis Models of Concrete Slabs-on-Grade Considering Horizontal Resistance at Slab Bottom and Behavior under Thermal Loads (슬래브 하부 수평저항을 고려한 지반위의 콘크리트 슬래브 해석 모델 및 온도하중에 의한 거동 분석)

  • Kim Seong-Min;An Zu-Og
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.3 s.73
    • /
    • pp.271-282
    • /
    • 2006
  • The behavior of the concrete slabs on grade considering the horizontal resistance at the slab bottom, which exists due to the shear resistance of the foundation and the friction between the slab and the foundation, has been investigated when the slabs-on-grade are subjected to the thermal load. Analytical formulations have been developed to include the effect of the horizontal resistance at the slab bottom employing the thin plate on an elastic foundation that is widely used for the analysis of concrete slabs-on-grade and rigid pavement systems. Finite element formulations have then been developed using the plate bending elements and the flat shell elements. The solutions from the analytical and numerical models have been compared and showed very good agreement. The sensitivity of the horizontal resistance to the stresses of the concrete slab has been investigated with various values of the slab thickness, elastic modulus, and vortical stiffness of the foundation when subjected to the temperature gradient between the top and bottom of the slab and the uniform temperature drop throughout the slab depth. The analysis results show that the horizontal resistance at the plate bottom can significantly affect the stresses of the slab when the thermal loads are applied.

The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D FSPGR T1 Technique and Fat Suppressed Isotropic 3D FSE T1 Technique when Examining MRI of Patient with Triangular Fibrocartilage Complex (TFCC) Tear (삼각 섬유성 연골(TFCC) 손상 환자의 자기공명영상 검사 시 Fat Suppressed 3D FSPGR T1 강조 기법에 대한 Fat Suppressed Isotropic 3D FSE T1 강조 기법의 비교 분석 및 유용성에 관한 평가)

  • Kang, Sung-Jin;Cho, Yong-Keun;Lee, Sung-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.105-114
    • /
    • 2016
  • In this study, For assessment of triangular fibrocartilage complex (TFCC) injury, we acquired images by fat suppressed 3D fast spoiled gradient recalled T1 and fat suppressed Isotropic 3D fast spin echo T1 techniques. For quantitative evaluation, measured signal to noise ratio and contrast to noise ratio and verified statistical significance between two imaging techniques by Mann-Whitney U verification. And for qualitative evaluation, marked 4-grade scoring (0: non diagnostic, 1: poor, 2: adequate, 3: good) on shape of TFCC, artifacts by partial volumes, description of the lesions by two radiologist, verified coincidence between 2 observer using Kappa-value verification. We used 3.0 Tesla MR equipment and 8-channel RF coil for imaging acquisition. As quantitative evaluation results, signal to noise ratio and contrast to noise ratio value of Isotropic 3D fast spin echo T1 technique is higher in every image sections, also between two imaging techniques by Mann-Whitney U verification was statistically significant (p < 0.05). As qualitative results, observer 1, 2 marked a higher grade on Isotropic 3D FSE T1 technique, coincidence verification of evaluation results between two observers by Kappa-value verification was statistically significant (p < 0.05). As a result, during MRI examination on TFCC injury, fat suppressed Isotropic 3D fast spin echo T1 technique is considered offering more useful information about abnormal lesion of TFCC.

Application of Landscape Ecology Indicators for Conservation Value Assessment (보전가치평가를 위한 경관생태학적 지표의 활용 및 적용)

  • Lee, Dong-Kun;Yoon, So-Won;Kim, Eun-Young;Jeon, Seong-Woo;Choi, Jae-Yong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.6 s.107
    • /
    • pp.14-22
    • /
    • 2005
  • The purpose of this paper is to assess conservation value of forests and cultivated areas from the landscape ecological point of view. The main focus of landscape ecology estimates the reciprocal relationships between spatial patterns and ecological processes. This paper sets the criteria for conservation value and classify the conservation value based on the criteria. Forests and cultivated areas in Seo-Gu, Incheon Metropolitan City was selected as the case study area. In this research, factors such as patch size and connectivity have been selected in order to consider the landscape ecological aspect, gradient for the environmental physics aspect and to consider the environment-ecological aspect, grade of environmental-oriented land suitability analysis Map developed by the ROK Ministry of Environment has been utilized. GIS methodologies have been adopted to calculate the relationships among the above variables. Through literature review, the following evaluation criteria have been adopted: (1) based on island biogeography and metapopulation dynamics theory, patch size criteria are set 2ha and 10ha; (2) connectivity was set the degree of connection with surrounding grids; and (3) gradient of 20 degrees. Conclusively, this paper suggests that local conditions, landscape ecology and physical environment aspects should be considered to develop an estimation framework of the conservation value.

Analyzing the Disaster Vulnerability of Mt. Baekdusan Area Using Terrain Factors (지형 요소를 고려한 백두산 지역의 위험도 분석)

  • Choi, Eun-Kyeong;Kim, Sung-Wook;Lee, Young-Cheol;Lee, Kyu-Hwan;Kim, In-Soo
    • Journal of the Korean earth science society
    • /
    • v.34 no.7
    • /
    • pp.605-614
    • /
    • 2013
  • Most steep slope failures tend to take place in geographically unstable areas. Mt. Baekdusan is known as a potentially active volcano in a typical mountainous terrain. This study prepared a digital elevation model of Mt. Baekdusan area and created a hazard map based on topographical factors and structural lineament analysis. Factors used in vulnerability analysis included geographical data involving aspect and slope distribution, as well as contributory area of upslope, tangential gradient curvature, profile gradient curvature, and the distribution of wetness index among the elements that comprise topography. In addition, the stability analysis was conducted based on the lineament intensity map. Concerning the disaster vulnerability of Mt. Baekdusan region, the south and south west area of Mt. Baekdusan has a highest risk of disaster (grade 4-5) while the risk level decreases in the north eastern region.