• Title/Summary/Keyword: Gradient AC/A

Search Result 37, Processing Time 0.04 seconds

Study on Proximal Convergence/Accommodation(PC/A) Ratio by Comparison of Gradient AC/A Ratio and Calculated AC/A Ratio (Gradient AC/A비와 Calculated AC/A비의 비교에 의한 근접성 폭주비(PC/A)에 관한 연구)

  • Han, Gyeong-Ae;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.223-231
    • /
    • 2004
  • In most previous studies, the assessment of accommodative convergence to accommodative stimulus (AC/A) ratio was commonly made by measuring gradient AC/A ratio. This study deals with the proximal convergence/accommodation(PC/A)ratio measured by comparing values of the gradient AC/A ratio and the calculated AC/A ratio to prevail the clinical use of the AC/A ratio. Visual acuities of All 124 subjects had been corrected to at least 1.0 with either eye through their habitual refractive correction and the MEM dynamic retinoscopy was performed to estimate their accommodative response. And then the PC/A ratio was calculated by making use of the calculated AC/A ratio and the gradient AC/A ratio. This study showed that the difference between the mean calculated AC/A ratio and the mean gradient AC/A ratio in subgroups may be attributable to proximal convergence. Consequently, further studies on proximity cues including the PC/A ratio could be helpful to prevail the clinical use of the AC/A ratio.

  • PDF

The Study of Distance and Near AC/A Ratio by Stimulus (조절자극 방식에 따른 원거리와 근거리 AC/A비에 관한 연구)

  • Jo, Tae-Sik;Kim, In-Suk;Jang, Jung-Un
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.417-423
    • /
    • 2011
  • Purpose: This study was to investigate that near gradient AC/A ratio could be used to prescribe a patient with distance exophoria, we compared the difference between distance gradient AC/A ratio and near gradient AC/A ratio. Also, this thesis was to understand the relationship between calculated AC/A ratio and gradient AC/A ratio. Methods: Objective and subjective refractive error were corrected and we used Howell (3 m) chart for distance phoria tests and Howell-Kim (40 cm) chart for near phoria tests. The near gradient AC/A ratio and calculated AC/A ratio were used by Howell-Kim (40 cm) combined with +1.00 D, -1.00 D, +2.00 D and -2.00 D. Results: The average value of distance exophoria was 1.17${\pm}$1.17 $\Delta$, and the average value of near exophoria was 3.71${\pm}$2.80 $\Delta$ (t-test. p<0.001). The correlation of distance phoria with near phoria was little higher (r = 0.59, p < 0.001). Gradient AC/A ratios depending on measuring distance and stimulus were higher (r = 0.11~0.53. P < 0.001), when distance was shorter and stimulus to accommodation was more. Also, stimulus to accommodation by plus lens was higher than stimulus to accommodation by minus lens (paired t-test. p < 0.001). There was negative correlation between calculated AC/A ratio and gradient AC/A ratio. As the calculated AC/A ratio was higher, gradient AC/A ratio was lesser. Near gradient AC/A ratio was slightly higher than distance gradient AC/A ratio. Distance and near gradient AC/A ratio taken through the subjective -1.00 D were 1.30 $\Delta$/D and 1.68 $\Delta$/D(t-test. t=1.67, p < 0.001). Conclusions: There is negative correlation between calculated AC/A ratio and gradient AC/A ratio. Also, there is subtle difference between near gradient AC/A ratio and distance gradient AC/A ratio. Therefore, we need to measure distance gradient AC/A ratio when a practitioner prescribe glasses for a patient with distance exophoria.

Study on the Influence of LASIK on Binocular Change (양안시 변화에 대한 라식수술의 영향에 관한 연구)

  • Lee, Ki-Seok;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.267-273
    • /
    • 2006
  • For this study, we measured heterophoria, Calculated AC/A, Gradient AC/A of pre & post LASIK operation. In case of heterophoria, the results showed that orthophoria 2.78% decreased, exophoria 2.78% increased on pre & post op distance phoria and exophoria 5.55% increased, esophoria 5.55% decreased on pre & post op near phoria. In case of AC/A, Calculated AC/A significantly decreased as 0.36 at AC/A and accommodation decreased as 1.25D (p<0.05). It showed that Gradient AC/A decreased 0.34 and PC/A increased 0.09 but they didn't show significant difference.

  • PDF

The Analysis of Binocular Vision Function by measuring Accommodative Convergence(AC/A) (조절성 폭주비(AC/A) 측정에 의한 양안시 기능 분석)

  • Kang, In-San;Seo, Yong-Won;Choi, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.159-164
    • /
    • 2005
  • Accommodation and convergence is combination movement which is closely connected with each other. When one of them is stimulated, both of functions occur at the same time. Specially, the convergence by the accommodation's stimulation is called as accommodative convergence. That has excess or deficiency according to refraction state of eye. This study was performed by using both of Gradient method and Heterophoria method to 41 adults who have no any ophthalmic disease. 1. As the result of investigation about the distribution of heterophoria at distance, there were orthophoria of 5 subjects, exophoria of 32 and esophoria of 4. Exoporia occupied at the hightest rate. The distribution of heterophoria at near cover a wider range more than at distance. 2. When we measured the horizontal heterophoria amount in the state of relaxation of accommodation power of lens, exophoria amount increased in case of 38 subjects. 3. The person who has $4{\sim}6{\Delta}/D$ which conform to normal AC/A ratio occupied 27 subjects(66%) in Heterophoria method and 16(39%) in Gradient method, respectively.

  • PDF

Mechanism of Electrohydrodynamic Flow in AC Electrowetting (AC 전기습윤 중 전기수력학 유동의 메카니즘)

  • Lee, Ho-Rim;Ko, Sung-Hee;Yun, Sung-Chan;Kang, Kwan-Hyoung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2648-2651
    • /
    • 2008
  • In AC electrowetting, it has been reported that there is a flow inside droplets. The flow characteristics such as flow rate, direction and the pattern of streamline are altered according to the frequency range of applied voltage. However, the mechanism of the flow has not been explained yet. This work is concentrated on investigation of the flow mechanism when high-frequency voltage is applied to droplets. We propose that this phenomenon arises from the electro-thermal flow. A numerical analysis is performed for the needle-electrode-plane geometry in which the Coulombic force term is included in the Navier-Stokes equation. According to our analysis, electrical charge is generated due to conductivity gradient which is originated from the nonuniform Joule heating of fluid medium. The result of the analysis is compared with experimental result.

  • PDF

The application of DGTs for assessing the effectiveness of in situ management of Hg and heavy metal contaminated sediment

  • Bailon, Mark Xavier;Park, Minoh;Choi, Young-Gyun;Reible, Danny;Hong, Yongseok
    • Membrane and Water Treatment
    • /
    • v.11 no.1
    • /
    • pp.11-23
    • /
    • 2020
  • The effectiveness of in situ sediment capping as a technique for heavy metal risk mitigation in Hyeongsan River estuary, South Korea was studied. Sites in the estuary were found previously to show moderate to high levels of contamination of mercury, methylmercury and other heavy metals. A 400 m × 50 m section of the river was selected for a thin layer capping demonstration, where the total area was divided into 4 sections capped with different combinations of capping materials (zeolite, AC/zeolite, AC/sand, zeolite/sand). Pore water concentrations in the different sites were studied using diffusive gradient in thin film (DGT) probes. All capping amendments showed reduction in the pore water concentration of the different heavy metals with top 5 cm showing %reduction greater than 90% for some heavy metals. The relative maxima for the different metals were found to be translated to lower depths with addition of the caps. For two-layered cap with AC, order of placement should be considered since AC can easily be displaced due to its relatively low density. Investigation of methylmercury (MeHg) in the site showed that MeHg and %MeHg in pore water corresponds well with maxima for sulfide, Fe and Mn suggesting mercury methylation as probably coupled with sulfate, Fe and Mn reduction in sediments. Our results showed that thin-layer capping of active sorbents AC and zeolite, in combination with passive sand caps, are potential remediation strategy for sediments contaminated with heavy metals.

Application of Optical Method for Quantitative Investigation of MgO Erosion in AC-PDP

  • Choi, Seung-Ho;Lee, Soon-Il;Oh, Soo-Ghee;SunWoo, Jin-Ho;Kim, Jae-Gak;Lee, Gol-Hee;Kim, June-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.185-186
    • /
    • 2000
  • For the quantitative investigation of the erosion of MgO layers in real ac-PDP cells, we constructed a microscopic spectrophotometer which is capable of measuring transmission spectra from the area as small as 20 ${\times}$ 20 ${\mu}m^2$. In the test on the sputtered MgO films with a thickness gradient, we were able to probe the thickness variation of 1000 nm over $1000-{\mu}m$ distance. Using this instrument, we were able to determine not only the erosion rate at the particular position of ac-PDP cells but also the relative erosion rate at different positions in a single ac-PDP cell.

  • PDF

Comparison between Stimulus and Response AC/A Ratios for Each Phoria with Additional Spherical Power (사위별 가입렌즈에 따른 자극 AC/A비와 반응 AC/A비의 비교)

  • Lee, Se-Hee;Yu, Dong-Sik;Son, Jeong-Sik;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.345-351
    • /
    • 2014
  • Purpose: The accommodative response and the near horizontal phoria were examined with additional spherical power to analyze the stimulus and response AC/A ratios that suggest reference data for the binocular vision. Methods: The open-field autorefractometer (Nvision-K 5001, Shin nippon) and modified thorington method (MIM card; Muscle Imbalance Measure card, Bernell) at 40 cm were utilized to measure the accommodative response and the near horizontal phoria for 81 persons ($20.89{\pm}1.92$ years old) with additional spherical power. The stimulus and the response AC/A ratios were calculated by gradient AC/A method. Results: The exophoria group showed the highest accommodative response ($1.92{\pm}0.26D$) at 40 cm, followed by orthophoria group and esophoria group($1.72{\pm}0.26D$ and $1.62{\pm}0.42D$, respectively) Meanwhile, the esophoria group showed the biggest ocular deviation for the near ($23.24{\Delta}$) followed by the orthophoria group and exophoria group ($19.76{\Delta}$ and $15.14{\Delta}$, respectively). The biggest difference of the stimulus and the response AC/A ratios was $1.72{\Delta}$ for the exophoria group with -2.00 D, while the one was $3.43{\Delta}$ for the esophoria group with +1.00 D. There was a significant difference between AC/A ratios for the exophoria group with -2.00 D, -1.00 D and the esophoria group with +3.00 D, +2.00D, +1.00D and -1.00D. Conclusions: The difference between stimulus and response AC/A was greater when increased minus spherical power for the exophoria group, while it was greater when increased plus spherical power for the esophoria group. Furthermore, the difference for the esophoria group was a greater than the one for the exophoria group.

Automatic Bone Segmentation from CT Images Using Chan-Vese Multiphase Active Contour

  • Truc, P.T.H.;Kim, T.S.;Kim, Y.H.;Ahn, Y.B.;Lee, Y.K.;Lee, S.Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.713-720
    • /
    • 2007
  • In image-guided surgery, automatic bone segmentation of Computed Tomography (CT) images is an important but challenging step. Previous attempts include intensity-, edge-, region-, and deformable curve-based approaches [1], but none claims fully satisfactory performance. Although active contour (AC) techniques possess many excellent characteristics, their applications in CT image segmentation have not worthily exploited yet. In this study, we have evaluated the automaticity and performance of the model of Chan-Vese Multiphase AC Without Edges towards knee bone segmentation from CT images. This model is suitable because it is initialization-insensitive and topology-adaptive. Its segmentation results have been qualitatively compared with those from four other widely used AC models: namely Gradient Vector Flow (GVF) AC, Geometric AC, Geodesic AC, and GVF Fast Geometric AC. To quantitatively evaluate its performance, the results from a commercial software and a medical expert have been used. The evaluation results show that the Chan-Vese model provides superior performance with least user interaction, proving its suitability for automatic bone segmentation from CT images.