• Title/Summary/Keyword: Grade efficiency

Search Result 474, Processing Time 0.037 seconds

A Study of High Particle Collection Efficiency of Cyclone (고효율 사이클론의 집진효율에 관한 연구)

  • Chung, Jin-Do;Lee, Sang-Gwon;Bohnet, M.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2227-2232
    • /
    • 2003
  • For a reasonable analysis of grade efficiency of cyclone separator, in-line measurements of particle size and particle concentration are needed. The purpose of this study is to define the correlation of measurement data and to measure grade efficiency and pressure drop. The authors adapted that the grade efficiency could be calculated directly from the counted particle numbers. The problem of collection efficiency calculation was different from counting rate of aerosol counters under the same conditions. It is important factor to use the rate of the particle counters to obtain reliable results. Therefore, the authors should use and calculate compensation factor considering sensitivity of aerosol counters, gas velocity and concentration affect higher 30% than originally measured grade efficiency. As the pressure drop and grade efficiency increase, as flow rate increase and then also pressure drop and grade efficiency increase.

  • PDF

Classification Index and Grade Levels for Energy Efficiency Classification of Agricultural Heaters in Korea

  • Shin, Chang Seop;Jang, Ji Hoon;Kim, Young Tae;Kim, Kyeong Uk
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.264-269
    • /
    • 2013
  • Purpose: This study was carried out to develop a classification index and grade levels to rate agricultural heaters for energy efficiency classification. Methods: The classification index was developed mainly by taking simplicity of calculation and easy access to relevant data into consideration. The grade levels were developed on the basis of a 5-grade classification system in which graded heaters are to be normally distributed over the grades. The value of each grade level were determined in terms of the classification index values calculated using the published performance data of agricultural heaters tested at the FACT in Korea over the past 12 years. Results: The thermal efficiency of agricultural heaters based on the enthalpy method was proposed as a reasonable classification index. The grade levels were proposed in equation form for three types of agricultural heaters: fossil fuel heaters, wood pellet heaters and wood pellet boilers. A reasonable energy efficiency classification of agricultural heaters could be performed using the proposed classification index and grade levels. Conclusions: It is expected that energy saving programs will be extended to agricultural machines in the near future. The classification index and grade levels to rate agricultural heaters for energy efficiency classification were developed and proposed for such near future to come.

Classification Index and Grade Levels for Energy Efficiency Classification of Agricultural Dryers in Korea

  • Shin, Chang Seop;Park, Jin Geun;Kim, Kyeong Uk
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.96-100
    • /
    • 2014
  • Purpose: The objective of this study was to develop a classification index and the grade levels for a five-grade energy efficiency classification of agricultural dryers in Korea. Methods: The classification index and the grade levels were determined by using the performance test data published by the FACT over the last eight years to reflect a state of the art technology for agricultural dryers in Korea. The five grades were designed to have the classified dryers distributed normally over the grades with 15% for the $1^{st}$ grade, 20% for the $2^{nd}$ grade, 30% for the $3^{rd}$ grade, 20% for the $4^{th}$ grade and 15% for the $5^{th}$ grade. Results: The classification index was defined as the total amount of fuel and electrical energy consumed per 1% of the wet basis moisture content evaporated from a unit mass of grain or agricultural crops during the drying process: 1 MT of paddy rice for grain dryers and 1 kg of red pepper for agricultural crop dryers as the standard mass. Conclusions: The grade levels for the five-grade energy efficiency classification of grain dryers, kerosene dryers, and electric dryers were proposed in terms of the classification index value.

The slope effect of grade efficiency curve in a two-stage cyclone (등급집진효율 곡선의 기울기가 2단 사이클론의 집진효율에 미치는 영향)

  • Heo, Kwang-Su;Seol, Seoung-Yun;Kim, Min-Ha
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1963-1968
    • /
    • 2004
  • A collection efficiency of cyclone is influenced by cut-size and slope of grade efficiency curve. It has been recognized that the collection efficiency is improved when the cut-size is reduced. However, effects of the slope have never been studied so far. In this study, we analyze a relationship between slope of grade efficiency and collection efficiency in two-stage cyclones. In single stage cyclones, higher slope cyclones have high efficiency. On the contrary to single stage cyclone, collection efficiency of two-stage cyclone have the maximum value when the first cyclone has a lower slope and second cyclone is high.

  • PDF

Energy Efficiency Classification of Agricultural Tractors in Korea

  • Shin, Chang-Seop;Kim, Kyeong-Uk;Kim, Kwan-Woo
    • Journal of Biosystems Engineering
    • /
    • v.37 no.4
    • /
    • pp.215-224
    • /
    • 2012
  • Purpose: This study was conducted to classify the energy efficiency of 131 tractor models tested during from 2006 to 2010 in Korea. Methods: Four sub-indexes were developed using the fuel consumptions at 60% and 90% of rated speed with partial loads and at pull speeds of 3.0 km/h and 7.5 km/h with maximum drawbar pull. Weighting factors of the sub-indexes were also considered to reflect the characteristics of tractor's actual working hours in Korea. Four sub-indexes were integrated into a classification index. Using the developed classification index, a five-classification system was made on the basis of normal distribution of tractors over the classification range. Percentage of $1^{st}$ grade interval was expected to be close to 15%, $2^{nd}$ grade 20%, $3^{rd}$ grade 30%, $4^{th}$ grade 20%, $5^{th}$ grade 15%. Results: Number of $1^{st}$ grade was 21, $2^{nd}$ grade 23, $3^{rd}$ grade 39, $4^{th}$ grade 33, $5^{th}$ grade 15 among 131 models. Conclusions: Classification index was developed by integrating four sub-indexes. By the classification method using developed index, distribution of classified tractors was acceptable for practical application.

Rating of Agricultural Tractors by Fuel Efficiency (농업용 트랙터의 연료 소비 효율 등급화)

  • Kim, Soo-Chul;Kim, Kyeong-Uk
    • Journal of Biosystems Engineering
    • /
    • v.35 no.2
    • /
    • pp.69-76
    • /
    • 2010
  • This study was conducted to develop an index of fuel consumption to rate agricultural tractors by their fuel efficiencies. The fuel consumption index consisted of two components: basic and operational indexes. The basic index is to consider an average amount of fuel consumed by engine when it transmits 20 and 100% of the rated power. The operational index is to consider the fuel consumed by tractor for typical field operations: plowing, rotavating, and the remains. The equations and procedures to obtain these indexes were proposed. The method and fuel consumption rate to classify tractors into 5 grades were also proposed. The best 15% of the tractor models were rated as the first grade, 20% as the second grade, 30% as the third grade, 20% as the fourth grade, and 15% as the fifth grade in order of fuel efficiency. Using the fuel consumption index, the classification was conducted on 143 tractor models tested at the National Institute of Agricultural Engineering from 2000 to 2007. The proposed 5-grade system of classification using the fuel consumption index could be used to rate the fuel efficiency of 20-100 kW tractor models produced over past 10 years in Korea.

A Study on the Grade Efficiency of Sturtevant Type Air Classifier (스터테반트 공기분급기의 분리효율에 대한 연구)

  • 정인기;박시우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.773-781
    • /
    • 2004
  • This research was Performed to raise grade efficiency of Sturtevant type air classifier. to treat powder less than $74\mu\textrm{m}$ particle produced at the crushing process of the dry aggregates manufacturing system or concrete wastes recycling system. The experimental conditions were in the ranges. 0.85 to 5.15 $m^3$/s of primary air flow rate. 0.005 to 0.015 $m^3$/s of secondary air flow rate $30^{\circ}$ to $70^{\circ}$ of auxiliary blades angle. respectively. for 1.7~3.3 kg/min of the powder feed rate. It was found that the grade efficiency of the air classifier was increased as the baffle plate was attached at the expansion region. and the optimal operating conditions of the air flow rates and the blade angle were obtained. The fractional recovery curves from the experiments were well agreement with the theoretical one of Molerus model.

A Study on Energy Requirement Variation According to Energy Efficiency Rating Evaluation and Design Variable of Standard Design of Rural Houses (농촌주택표준설계도 에너지효율등급평가 및 설계변수에 따른 에너지소요량 변화에 관한 연구)

  • Park, Mi-Lan;Ryoo, Yeon-Su;Choi, Jeong-Man;Seo, Hye-Won
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.2
    • /
    • pp.9-16
    • /
    • 2017
  • The study analyzed the heat losses and the building energy efficiency grade by the energy simulation using the ENERGY# and ECO2 programs for the three types of Standard design of rural houses. It was calculated the energy efficiency rating by the ECO2 program for the rural housing standard design, and the energy demand and the energy consumption by each factor were compared and analyzed. And it analyzed energy consumption by element of each house by ENERGY # program. As a result, first in the evaluation of the energy efficiency grade of buildings by the ECO2 program, the rating for primary energy requirement for the housing newly built by the standard design of rural house is expected to range from 2 to 4 with 189.3 to $238.7kWh/m^2.a$. Second, the energy loss of each part of standard design of rural housing occurs in the order of ventilation 39%, window 33%, outer wall 14%, roof 9%, bottom 5%, and energy loss through ventilation and window occurs more than 70%. Third, the most beneficial effects on the energy efficiency grade is obtained the lowest grade of all three types by 2 when the lowering of the window and door heat transmission rate and the lowering of the light density, and the heat exchange ventilation device is not installed. Fourth, in the standard design of rural housing, the energy demand is occupied by heating > hot water > lighting order, and the order of the weight is changed in order of heating > lighting > ventilation > hot water. Fifth, building energy efficiency assessment system needs to establish policy for fixing rural housing energy as a practical device to ensure energy performance and quality.

Study on the Evaluation of Uncertainty for the Efficiency of 0.75[kW] Class Three Phase Induction Motor (0.75[kW]급 삼상유도전동기 효율의 불확도 평가에 관한 연구)

  • Jun, Hee-Deuk;Park, Han-Seok;Kim, Dea-Kyong;Woo, Kyung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.653-659
    • /
    • 2015
  • In the last few years, the regulations for efficiency grade of the three phase induction motor are internationally being discussed and upgraded for the protection of environment and energy saving. So the efficiency improvement and the reliable test result are essential to determine the premium grade three phase induction motor. While a study on developing the efficiency motor is active, there is little research about the guarantee for efficiency. So in this paper, the dispersion characteristic of the efficiency is studied using uncertainty theory for the three phase induction motor to improve the reliability of efficiency. The values such as input voltage, current, speed, torque were obtained by loss separation method to evaluate the uncertainty. From the result, it was known that the important loss factor could affect the uncertainty is the stray loss.

Energy efficiency standard for imaging equipments using electrophotograph printing (전자사진 기술을 사용하는 이미징 장치의 에너지 효율 기준 연구)

  • Park, Jun-Young;Yoon, Wonsik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2433-2442
    • /
    • 2014
  • In this paper, an efficiency grade standard for imaging equipments using electrophotograph printing such as a printer, copier, fax, and MFD (Multi Function Device) is studied. By emphasizing domestic standby power reduction program's problem, and proposing the necessity of efficiency management, the efficiency standard is developed by reliable data registered in domestic standby power reducing program. To find an efficiency indication for grade, correlation analysis is used and as a result, printing speed has the biggest correlation coefficient. By applying the efficiency indication for grade, the proposed certification standard is established in 1st to 5th level products and super-high-efficiency product (energy frontier) which is better than 1st to 5th level products. If these efficiency standards are chosen by government policies, it is expected to save 65 billion won reduction of energy cost per year.