• 제목/요약/키워드: Governor control

검색결과 151건 처리시간 0.026초

A Comparison and Evaluation of New Regulation on People Credit Funds Rating in Vietnam

  • Dang, Thu Thuy
    • Asian Journal of Business Environment
    • /
    • 제8권1호
    • /
    • pp.23-29
    • /
    • 2018
  • Purpose - The purpose of this research is to make a comparative assessment of People Credit Funds (PCFs) ranking in Vietnam between the Circular No. 42/2016/TT-NHNN dated December 20, 2016 with the Decision No. 14/2007/QD-NHNN dated 09/4/2007 issued by the Governor of the State Bank. Research design, data, and methodology - This study is mainly based on the Circular No. 42/2016/TT-NHNN dated December 20, 2016 and the Decision No. 14/2007/QD-NHNN dated 09/4/2007 issued by the Governor of the State Bank on PCFs ranking. Results - The study paper has shown positive changes in PCFs ranking in Vietnam in accordance with the Circular No. 42/2016/TT-NHNN, such as increasing Capital Adequacy Ratio (CAR), maintaining CAR, improving assets quality, developing indicators of governance, management and control capability. These changes have implications for the development and efficient performance of PCFs in Vietnam. Conclusions - The classification and evaluation of PCFs will contribute to its healthy development. These finding support PCFs to understand more about rating methodology, significance of rating system and the importance of improving their rating. PCFs in Vietnam desire to develop their business effectively, they need to understand exactly and comply fully with regulations related to their field of operations.

쿠바 주파수조정 ESS 운영 전략 검토: 주파수 보상 효과 분석 (Feasibility Study for Application of Frequency Regulation ESS in Cuba: Technological Effects on Improving Frequency Compensation)

  • 김수열;이성은;김진태
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.123-127
    • /
    • 2020
  • KEPCO has installed Frequency Regulation ESS (FR ESS) of 376 MW since 2015. Frequency Regulation is ancillary service to support stabilizing system frequency, which is divided into governor free and automatic generation control. KEPCO operates FR ESS as governor free application and leads FR ESS market with capability of diverse demonstration and operation experiences. To expand FR ESS role during transient states of power system, KEPCO has extended operating time of charging and discharging. KEPCO has also changed speed droop lower than before to improve contribution on frequency compensation, and acquired much experiences of differentiating bad cells from others. Based on these technologies and know-hows, KEPCO Research Institutes received request of feasibility study and technical cooperation for overseas FR ESS business. This paper suggests the simple and practical method for making technological feasibility study of FR ESS.

유압기계식 거버너의 실습용 시뮬레이션 모듈과 안정도의 조정 특성 (A simulation module to practice hydraulic mechanical governors and its adjustment characteristics for stability)

  • 최순만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.533-540
    • /
    • 2013
  • 거버너의 특성은 기관 운전에 큰 영향을 미치므로 이에 대한 운전자의 조정관리가 필요하나 PID 연산을 기초로 하는 디지털 거버너와 달리 유압식 거버너는 안정도의 조정 방식에서 큰 차이가 있다. 이러한 관계의 이해에는 실물장치의 유압식 거버너로 직접 실습하는 것이 효과적이나 엔진을 구동해야 하는 등 현실적인 어려움이 있으므로 본 연구에서는 시뮬레이션 모듈의 방법으로 안정도 등의 조정 실습이 가능하도록 주요 특성을 구현하였다. 거버너 모듈에는 스피드 설정, 스피드드룹 및 니들밸브와 보상포인터 등의 조정 파라미터가 포함되었으며 2차 함수의 엔진 전달함수를 결합하였다. 이로부터 안정도에 관련되는 조정 파라미터를 가변시킬 때 얻어지는 시스템에서의 속도 및 연료량의 응답 결과를 분석한 결과 제시된 모듈이 유압기계식 거버너의 제작자가 정하고 있는 니들밸브 및 보상지침의 일반적인 조정절차를 따라 조정 실습이 가능한 특성을 나타낸다는 것을 확인하였다.

영구자석 여자기형 발전기의 전압변동 억제 제어방식 (Permanent magnet excitation generator Voltage fluctuation suppression control method)

  • 조영준;곽윤창;이동희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.74-75
    • /
    • 2017
  • This paper proposes a control scheme of the voltage ripple suppression for the permanent magnet exciter generator. The output voltage of the permanent magnet excitation generator is affected by the field current, load current and the engine speed. The engine speed can be controlled by the governor. But, the actual frequency is changed at the starting and a sudden load variation. As a result, output voltage overshoot and undershoot can decrease the power quality in the grid system. The proposed control scheme uses a frequency factor to control the field current of the generator for the voltage ripple reduction. Because of the linkage flux is proportional to the frequency, the instantaneous frequency can consider the linkage flux. The proposed control method shows the improved control performance for the permanent magnet excitation generator through simulation.

  • PDF

A method of constructing fuzzy control rules for electric power systems

  • Ueda, Tomoyuki;Ishigame, Atsushi;Kawamoto, Shunji;Taniguchi, Tsuneo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1371-1376
    • /
    • 1990
  • The paper presents a method of constructing simple fuzzy control rules for the determination of stabilizing signals of automatic voltage regulator and governor, which are controllers of electric power systems. Fuzzy control rules are simplified by considering a coordinate transformation with the rotation angle .theta. on the phase plane, and by expanding the range of membership functions. Also, two rotation angles .theta. $_{1}$ and .theta. $_{2}$ are selected for the linearizable region and the nonlinear one of the system, respectively. Here, .theta. $_{1}$ is chosen by the pole assignment method, and .theta. $_{2}$ by a performance index. Fuzzy inference is applied to the connection of two rotation angles .theta. $_{1}$ and .theta. $_{1}$ by regarding the distance from the desired equilibrium point as a variable of condition parts. The control effect is demonstrated by an application of the proposed method to one-machine infinite-bus power system.

  • PDF

CANDU 시뮬레이션을 위한 증기발생기 모델링 (Steam Generator Modeling for CANDU Transient Simulation)

  • Seung, Seo-Jae;Cheon, Im-Jae;Park, Ji-Won;Sik, Jeong-U
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1994년도 춘계학술발표회 초록집
    • /
    • pp.138-143
    • /
    • 1994
  • A simplified steam generator model has been developed for the simulation of the operational transients of CANDU nuclear power plant. For the analysis of the secondary side, a control volume approach is used and the flow conservation equations are applied for each control volume. The typical steam generator control logic such as the level control and the pressure control are incorporated into the steam generator model with appropriate interface conditions. The steam line including ASDV, CSDV, and governor valve also has been modeled. Test results for typical operational transient case show reasonable transient behavior of steam generator in a real time basis, which is promising for a CANDU engineering simulator.

  • PDF

퍼지추론을 이용한 수차 속도제어기 동조기법에 관한 연구 (A Study on Tuning Method of Turbine Speed Controller Using Fuzzy Inference)

  • 이정환;김운해;백두현;성기민;신강욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.316-318
    • /
    • 1993
  • In order to estimation the optimum PID parameter of the turbine speed controller, the response cure of the object plant was compared with the reference pattern and then the magnitude peak value error and peak time error was calculated. With the calculated errors as input into the Fuzzy inference Method was introduced to propose the tuning method for each parameter. And the computer simulation was performed with the above Fuzzy inference method in which the Chunju hydro power plant turbine governor system was used as a model. This Study also aims to develop the exclusive tuner for govenor using industrial computer.

  • PDF

터빈 속도신호의 자동백업 시스템 개발 (Development of automatic backup systems for turbine speed signal)

  • 김관행;김호찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.844-846
    • /
    • 1999
  • A speed signal of governor, which control the output and speed of a generator, is important because a signal failure can be causing the shutdown of a power plant. thus, it is necessary to introduce switching method with two complementary signal. This paper presents a comparative study of speed signal switching methods. One of the Proposed methods has been tested at a power plant in Pukcheju and the approach described here is expected to be of wide applicability.

  • PDF

증기터빈 조속기용 서보밸브 제어특성에 대한 연구 (A study on characteristic of servovalve control for steam turbine governor)

  • 김병철;김종안;우주희;최인규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2263-2265
    • /
    • 2004
  • 발전소 증기터빈 밸브제어의 핵심을 이루고 있는 서보밸브 제어특성을 파악하고, 조속기 개조에 필요한 제어루프 구성방법 및 각종 제어상수를 시험을 통해 미리 파악하여 교체 적응 시에 발생될 문제점을 해결하고자 시험한 내용을 서술하고자 한다.

  • PDF