• 제목/요약/키워드: Gore-Tex

검색결과 136건 처리시간 0.027초

쥐의 두개골에서 융비술에 사용되는 수종의 이식재에 대한 조직학적 연구 (A HISTOLOGICAL STUDY ON SEVERAL IMPLANTS FOR AUGMENTATION RHINOPLASTY IN MOUSE CALVARIUM)

  • 김현섭;국민석;박홍주;오희균;김형석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권4호
    • /
    • pp.289-300
    • /
    • 2007
  • Purpose: This study was aimed to histologically evaluate $Silicone^{(R)}$, $Gore-tex^{(R)}$, $AlloDerm^{(R)}$, and $Medpor^{(R)}$ implants for augmentation rhinoplasty after graft in the subperiosteum of mural calvarium respectively. Materials and method: Twenty four male ICR mice were used. $Silicone^{(R)}$, $Gore-tex^{(R)}$, $AlloDerm^{(R)}$, and $Medpor^{(R)}$ were grafted respectively in the subperiosteum of frontal bone. Animals were sacrificed at 1 week, 4 week and 8 week after graft. Histological observation was performed after H&E staining. Results: All groups were healed without any extrusion of implant materials and inflammatory cell infiltration. In Silicone group, $Silicone^{(R)}$ was well enclosed by thin fibrous tissue at 1 week, which became thicker and stable at 4 weeks and 8 weeks. And there was no destruction or resorption of $Silicone^{(R)}$ In Gore-tex group, there was no destruction or resorption of $Gore-tex^{(R)}$. Thin fibrous tissue and cell infiltration from peripheral tissue were observed at 1 week, 4 weeks and 8 weeks. In AlloDerm group, $AlloDerm^{(R)}$ was enclosed by fibrous tissue. Cell infiltration was observed at 1 week, 4 weeks and 8 weeks. In Medpor group, there was no inflammation, destruction or resorption of $Medpor^{(R)}$ and it was contacted directly to the bone without interposition of fibrous tissue. Porous area was filled by bone or soft tissue. Conclusion: These results suggest that $Gore-tex^{(R)}$, $AlloDerm^{(R)}$, and $Medpor^{(R)}$ graft are more stable than $Silicone^{(R)}$ graft and that $Silicone^{(R)}$, $Gore-tex^{(R)}$, $AlloDerm^{(R)}$ are appropriate for graft on nasal tip and $Medpor^{(R)}$ is appropriate for graft on nasal dorsum.

Gore-TexTMmembrane과 COLLACOTE®를 이용한 골유도 재생술의 조직학적 비교 연구 (HISTOLOGICAL COMPARATIVE STUDY OF GUIDED BONE REGENERATION WITH GORE-TEX-TXMEMBRANE AND COLLACOTE®)

  • 김태규;장창덕;김철훈
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제19권1호
    • /
    • pp.15-24
    • /
    • 1997
  • The principle of guided tissue regeneration (GTR), as applied to bone healing, is based on the prevention of connective tissue from entering the bony defect during the healing phase. This allows the slower bone producing cells to migrate into and reproduce bone within the defect. GTR has demonstrated a level of success in regenerating bone defect. Several types of membrane barrier have been utilized to apply this principle in bone regeneration. The purpose of this study was to evaluate whether improved bone regeneration can be achieved with different membrane barriers ($Gore-Tex^{TM}$membrane, $COLLACOTE^{(R)}$). In the 10 NewZealand white rabbits, full-thickness bone defects on three sites of each rabbit calvaria were made. Experimental group 1 was covered with $COLLACOTE^{(R)}$, and group 2 was covered with $Gore-Tex^{TM}$membrane. Macroscopic, microscopic examinations were made serially on 1, 2, 3, 6, 12 weeks after operation. The results were as follows : 1. Macroscopically, both of experimental group 1, 2 were filled with bone-like mass but the defects of experimental group 1 disclosed markedly thinner than the original bone. 2. Microscopically, the defect of experimental group 1, 2 was filled with bony trabeculae without infection and adverse reaction. But multinucleated giant cell infiltration around $COLLACOTE^{(R)}$ was seen till 6th week. 3. Resorption of $COLLACOTE^{(R)}$ started from 3rd week and it was completely resorped on the 12th week.

  • PDF

치주조직유도재생술 시행시 Gore-tex 차폐막에 부착되는 치주세균에 대한 미노클린첨부제의 향균력에 대한 미생물학적 연구 (Microbiological study of the antibacterial effects of locally delivered $Minocycline^R$ on the plaque accumulation on $Gore-tex^R$ membrane during the guided tissue regeneration therapy)

  • 최점일;주애라
    • Journal of Periodontal and Implant Science
    • /
    • 제26권2호
    • /
    • pp.356-364
    • /
    • 1996
  • The present study was done to evaluate the antibacterial effects of $Minoclin^R$ which was localally delivered on the $Gore-tex^R$ barrier membrane in the guided tissue regeneration(GTR) therapy for treatment of human furcal defects. Beneath the membranes. the antibiotics were applied for 1 week and then changed with new one. The $Minoclin^R$ was removed out one week later. 6 weeks after the GTR therapy. No systemic antibiotics were administered except for oral mouthrinses with chlorhexidines. 2 weeks and 6 weeks following the membrane therapy, the bacterial samples were examined for periodontopathic microorganisms. The results indicated that the locally delivered $Minoclin^R$ successfully inhibited the growth of periodontopathic organisms. This results might be further applied in the subgingival plaque control regimen in the GTR procedure, especialy in patients who is contraindicated for oral administration of systemic antibiotics

  • PDF

GoreTex$^{\circledR}$ 인조혈관을 이용한 해리성 하행 흉부대동맥류 성형술 - 수술치험 2례 - (Aortoplasty with Using Gore-Tex Conduit in Dissecting Aneurysms of Descending Thoracic Aorta - Two Cases Report -)

  • 정진용
    • Journal of Chest Surgery
    • /
    • 제22권5호
    • /
    • pp.816-822
    • /
    • 1989
  • Aneurysms of the descending thoracic aorta can be caused by various etiologies. So, its abrupt rupture leads life-threatening state, it must be operated as soon as possible. Surgical treatment of the descending thoracic aortic aneurysm requires temporary cross-clamping of major artery. The obligatory occlusion of the descending thoracic aorta during management causes proximal arterial hypertension and distal arterial hypotension. The former may leads to left ventricular failure, or cerebrovascular accident, whereas the latter may leads to spinal cord ischemia or renal injury. Some have recommended insertion of temporary shunt around the occluded descending aorta to prevent above problems. Still others would favor expeditious operation employing simple aortic occlusion during the repair of the descending aorta. Recently we had experienced two cases of dissecting aneurysms of descending thoracic aorta which performed aortoplasty with Gore-Tex conduit under simple aortic occlusion. The one was 34-year-old female patient with traumatic dissecting aortic aneurysm [5 em X 5 cm] on the descending thoracic aorta distal to the origin of the left subclavian artery and the other was 58-year-old female patient with atherosclerotic dissecting descending thoracic aortic aneurysm [6 cmX7 cm] and diffuse abdominal aortic aneurysms [3X5 cm]. Both patients performed standard left posterolateral thoracotomy. After the aneurysmal sac was mobilized, occluding vascular clamps were placed on the transverse aorta proximal to the origin of the left subclavian artery, and on the distal descending aorta without adjuvant bypass procedures for 31 and 32 minutes, respectively, and the aneurysmal sac was repaired with 18 mm ringed Gore-Tex conduit graft. Both patients postoperative courses were uneventful.

  • PDF

치과용 연석고가 골조직재생에 미치는 영향에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE EFFECT OF CALCIUM SULFATE ON BONE REGENERATION)

  • 최장우
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제20권3호
    • /
    • pp.217-227
    • /
    • 1998
  • Calcium sulfate(plaster of Paris) has been used in dental and orthopedic surgery for about 100 years. It is well known that the plaster is bioresorbable, biocompatible, defect conformable and moldable. The purpose of this study is to evaluate two effects of calcium sulfate on bone regeneration, that is, the effects of graft materials and barrier for bone regeneration. Cortical bone defects were formed for recipient site on the femurs of 19 Sprague-Dawley rats. The autogenous particulated bone and calcium sulfate were grafted to the defects. Calcium sulfate paste, $Gore-Tex^R$ membrane(W.L. GORE & ASSOCIATES LTD., U.S.A.) and rubber sheet were used for the shielding materials. The results were as follows : 1. Calcium sulfate that had been grafted in the cortical bone defect was almost resorbed before bone remodeling, resultantly had little effect on bone regeneration. 2. Resoption process of calcium sulfate grafted on the bone grafting area tends to be accelerated, as being divided into numerous small particles progressively. Under the situation where the calcium sulfate was protected, with the coverage of fascia, $Gore-Tex^R$ membrane or rubber sheet, new bone formation was confirmed with presence of calcium sulfate particles over 6 weeks after grafting. 3. In the case of calcium sulfate covered with membrane, distinct bone formation was observed on the marrow space of femur adjacent to the plaster mass. 4. Rubber shielded plaster group revealed new bone trabeculae under the rubber sheet, but it showed ischemic degeneration of superficial cortical bone.

  • PDF

Dual Plane Augmentation Genioplasty Using Gore-Tex Chin Implants

  • Kim, Byung Jun;Lim, Jong Woo;Park, Ji Hoon;Lee, Yoon Ho
    • 대한두개안면성형외과학회지
    • /
    • 제15권2호
    • /
    • pp.82-88
    • /
    • 2014
  • Background: The chin shape and position is important in determining the general shape of the face, and augmentation genioplasty is performed alone or in combination with other aesthetic procedures. However, augmentation genioplasty using osteotomy is an invasive and complex procedure with the potential to damage mentalis muscle and mental nerve, to affect chin growth, and prolonged recovery. Our aim was to present our experience with a modified augmentation genioplasty procedure for hypoplastic chins using a Gore-Tex implant. Methods: Two vertical slit incisions were made at the canine level to create a supra-periosteal pocket between the incisions, preserving the periosteum and mentalis muscle. Minimal sub-periosteal dissection was performed lateral to the incisions along the mandibular border. The both wings of implant were inserted under the periosteum to achieve a stable dual plane implantation. Results: In total, 47 patients underwent dual plane chin augmentation using a Gore- Tex implant between January 2008 and May 2013. The mean age at operation was 25.77 years (range, 15-55 years). There were 3 cases of infection; one patient was treated with antibiotics, the others underwent implant removal. Additionally, two patients complained of postoperative parasthesia that spontaneously improved without any additional treatment. Most patients were satisfied with the postoperative outcomes, and no chin growth problems were observed among the younger patients. Conclusion: Dual plane Gore-Tex chin augmentation is a minimally-invasive operation that is simple and safe. All implants yielded satisfactory results with no significant complications such as mental nerve injury, lower lip incompetence, or chin growth limitation.

만성 신부전증 환자에서의 동정맥루조성술 (Clinical Analysis of Arteriovenous Fistula Formation for CRF Patiients)

  • 김응중;이영;박진석
    • Journal of Chest Surgery
    • /
    • 제27권8호
    • /
    • pp.669-676
    • /
    • 1994
  • Because the number of patients who require maintenance hemodialysis is increasing in number recently, angioaccess has become important to many vascular surgeons participating in the management of such patients.The authors created 269 arteriovenous fistulas[AVF] for angioaccess in 229 patients with chronic renal failure[CRF] at the Department of Thoracic and Cardiovascular Surgery in Chungnam National University Hospital during the period from August 1990 to March 1993. We analyzed the results of 260 operations for 220 patients except 9 patients who were lost during the follow up period. We performed snuffbox AVF in 171 cases, classic radiocephalic AVF in 46 cases, direct AVF at other site in 5 cases, forearm Gore-Tex AVF in 29 cases, and upper arm Gore-Tex AVF in 9 cases. We experienced 13 cases of operative failures, 11 cases of early complications, and 60 cases of late complications including obstructions during follow-up period. The 1 year, 2 year and 3 year patency rates of snuffbox AVF[Group 1], classic radiocephalic AVF[Group 2], and Gore-Tex AVF[Group 3] are like followings; 89, 84, 76% in group 1, 84, 75, 68% in group 2, and 79, 66, 55% in group 3. It showed a statistically significant difference between group 1, 2 and group 3.

  • PDF

수술가운의 방수성과 방균성에 관한 연구 (The Liquid and Viral Barrier Properties of Reusable and Disposable Surgical Gowns)

  • 송민규
    • 한국의류학회지
    • /
    • 제17권1호
    • /
    • pp.37-47
    • /
    • 1993
  • 최근에 치명적인 바이러스, 특히 에이즈를 이르키는 Human Immunodificiency Virus (HIV), 또는 간에 심각한 병을 이르키는 Hepatitis B Virus (HBV)와 같은 무서운 바이러스가 환자의 피나 분비물을 통하여 의사에게 전염되는 사례가 늘어감에 따라 이제는 환자의 피나 분비물의 침투를 막기 위해 방수성과 방균성을 가진 수술복 착용이 절대적으로 필요하게 되었다. 따라서 본 연구의 목적은 1. 수술가운을 만드는 5가지 대표적인 직물의 방수성과 방균성을 측정하고 2. 세탁시 표백제의 사용유무가 그 직물의 방수성과 방균성에 미치는 영향을 알아보고 3. 반복세탁이 그 직물의 방수성과 방균성에 미치는 영향을 알아 보는데 있다. 이 실험을 위해 3가지 재사용 수술가운과 (Gore-tex$^R$, membrane reinforced; Compel$^{TM}$, fabric reinforced; Acep$^{TM}$, non-reinforced) 두 가지 일회용 가운 (Evolution$^R$ gown, fabric reinforced; Evolution$^R$ Specialty, film reinforced)이 사용되었다. 표백제를 사용한 세탁이 직물의 방수성과 방균성에 미치는 영향을 알아보기 위해 재사용 가운을 세탁, 건조, 살균을 하였다. 세탁과 살균의 빈도수는 1, 20, 40, 50, 60, 70, 80번 이였다. 방수성 측정방법으로 1. Impact Penetration test (AATCC 42-1985), 2. Elbow Lean test, 3. Synthetic Blood Resistance test (ASTM F 23. 40. 01)가 사용되었고 방균성 측정방법으로 Viral Resistance test (ASTM F 23. 40. 02)가 사용되었다. 실험 결과는 다음과 같다. 1. Gore-Tex$^R$ 가운과 Evolution$^R$ Specialty 가운은 방수성과 방균성의 성질을 가졌다. 그러나 표백제를 사용하여 70번 세탁한 Gore-Tex$^R$ 가운은 membrane의 구조가 파괴되어서 방균성을 상실했다. 2. Evolution$^R$ 가운, Acep$^{TM}$ 가운과 Compel$^{TM}$ 가운은 오직 Impact Penetration test만 통과했다. 즉 이 직물들은 큰 압력의 가함이 없는 splash resistance만 가지고있다. 그러나 Acep$^{TM}$ 가운과 Compel$^{TM}$ 가운은 20번과 60번 세탁 후 각각 그들의 splash resistance 마져도 상실했다.

  • PDF

Tetracycline 처리된 조직유도재생술용 차폐막의 약제유리양상 및 구조적 변화 (Desorption Kinetics and Structural Changes of Tetracycline Treated Barrier Membranes for Guided Tissue Regeneration)

  • 이성미;정현주
    • Journal of Periodontal and Implant Science
    • /
    • 제27권1호
    • /
    • pp.1-17
    • /
    • 1997
  • Tetracycline is known to be effective in eliminating periodontopathogens and have collagenolytic activity. This study was performed to observe the desorption kinetics and structural changes of tetracycline-treated barrier membranes for guided tissue regeneration. Four kinds of barrier membranes were tested : $Tefgen^{(R)}$(American Custom Medical, USA) and $Gore-Tex^{(R)}$(W.L. Gore & Associates Inc., USA) as nonresorbable membranes ; Resolut(polyglycolide & polylactide copolymer, W.L. Gore & Associates Inc., USA) and $Biomend^{(R)}$(collagen, Collatec Co., USA) as resorbable membranes. The membranes were cut into discs(diameter : 4mm) and were immersed in 5% tridodecylmethylammonium chloride(TIMAC) ethanol and air-dried. The membrane discs were absorbed with $100{\mu}g/ml tetracycline solution(pH8) for one minute and dried. For desorption kinetics, TC treated discs were immersed in phosphate buffered saline solution (PBS, pH 7.4). PBS was exchanged daily and TC concentration was measured by absorbance at 276nm on UV spectrophotometer. To measure remaining antibacterial activity, discs of 1 day to 4 weeks after desorption were placed on Mueller Hinton agar containing Bacillus cereus and incubated aerobically in $37^{\circ}C$ for twelve hours and the inhibition diameters were measured. To observe the structural change of membranes after TIMAC treatment or immersion in PBS, the membrane discs were examined under SEM. The results were as follows : 1. Total amounts of TC absorbed into membrane discs($0.7536mm^2$) were $2000{\mu}g$, $1800{\mu}g$, $2625{\mu}g$ and $2499{\mu}g$ for $Tefgen^{(R)}$, $Gore-Tex^{(R)}$, $Biomend^{(R)}$ and $Resolut^{(R)}$. 2. The concentration of TC released from barrier membrane discs was maintained over $4{\mu}g/ml$ until the fifth day in nonresorbable membranes and $Resolut^{(R)}$, but until the fourth day in $Biomend^{(R)}$, Until the ninth day in nonresorbable membranes and until the seventh day in resorbable membranes, the TC concentration was maintained over $1{mu}g/ml$. 3. The four membrane discs in the first day showed similar size of inhibition zone. One to four weeks later, the inhibition zone was much smaller in resorbable membrane discs than nonresorbable membrane discs. 4. Any structural change due to treatment of TIMAC was not observed on the nonresorbable membranes. $Resolut^{(R)}$ did not show any structural change except fibrillar loosening during immersion period, but Biomend showed destruction of membrane structure from the first week of immersion. This study indicates that tetracycline treated barrier membranes lead to the sustained release of tetracycline for over 7 days. This slow release pattern of tetracycline may contribute to the favorable clinical outcome of guided tissue regeneration.

  • PDF

의인성 쇄골하 동맥류 수술 치험 1례 (Iatrogenic Subclavian Artery Aneurysm: Report of a Case)

  • 오중환;박승일;원준호
    • Journal of Chest Surgery
    • /
    • 제32권8호
    • /
    • pp.753-756
    • /
    • 1999
  • 쇄골하 동맥류는 희귀한 질환이며 파열의 위험성 때문에 외과적 수술이 필요하다. 43세 남자 환자가 쇄골 하 정맥 도관삽관술을 시행받고 우측 상지의 지각 저하와 동통을 주소로 내원하였다. 혈관 조영술 시행 결 과 쇄골하 정맥 도관삽관술후에 생긴 의인성 쇄골하 동맥류 진단하에 수술을 시행하였다. 6$\times$7 cm 정도의 동맥류 제거 후 6 mm Gore Tex 인조혈관으로 문합을 시행하였다. 술 후 환자는 특별한 합병증 없이 퇴원하 였으며 술 후 3개월 현재 외래를 통해 추적 관찰 중이다.

  • PDF