• Title/Summary/Keyword: Goniometry

Search Result 18, Processing Time 0.02 seconds

The Effects of Thoracic Spine Thrust Manipulation on Shoulder Pain, Range of Motion and Muscle Activity in 30′s Adults with Rounded Shoulder Posture (흉추 도수교정이 둥근어깨자세를 가진 30대 성인남녀의 통증, 관절가동범위, 근활성도에 미치는 영향)

  • Lee, Jae-nam;Yang, Seong-hwa;Gong, Won-tae
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.17-25
    • /
    • 2016
  • Purpose: This study was aimed to determine the effects of thoracic spine thrust manipulation on muscle activities of the scapular upward rotators and middle deltoid, active range of motion (AROM), shoulder pain, and rounded shoulder posture in young adults with rounded shoulder. Methods: The subjects were 30 young adults (14 males, 16 females) with rounded shoulder. Thirty subjects were randomly assigned to an experimental (manipulation) and control (placebo) groups of fifteen subjects respectively. The manipulation group received the manipulation (high velocity, low amplitude), which was performed by a physical therapist with the subject in the supine position and with the arms crossed over the chest and hands passed over the shoulders. For the sham group, the same procedure was performed, with the exception that the high-velocity thrust was not applied. Measurements were taken before and after the intervention. Muscle activity of upper and lower trapezius, serratus anterior, middle deltoid was measured using surface electromyography. Visual analog scale (VAS) was used for shoulder pain. Goniometry was used for shoulder abduction active range of motion (AROM). Straight edge was used for supine rounded shoulder posture (RSP) distance. Results: The muscle activity of the upper trapezius, lower trapezius and middle deltoid muscle increased significantly after the intervention (p<.05). However, no significant difference was observed in serratus anterior muscle (p>.05). The VAS was significantly decreased and AROM significantly increased after the intervention (p<.05). The distance of RSP were not significant (p>.05). The control group showed no differences before and after the intervention (p>.05). Conclusion: The results of this study suggest that thoracic spine thrust manipulation can be an effective component of treatment plan to improve pain and function.

  • PDF

The Effect of Taping on the Range of Motion and Proprioception at the Ankle Joint (테이핑이 발목의 관절가동범위와 고유수용성감각에 미치는 영향)

  • Kim, Chang-In;Kwon, Oh-Yun;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.8 no.3
    • /
    • pp.43-52
    • /
    • 2001
  • This study was designed to determine the effect of ankle taping and short period of walking on the treadmill on the range of motion (ROM) and proprioception at the ankle joint. Twenty healthy male subjects (mean age=24.2 yr) participated in this study. Goniometry and videotape replaying method were used to measure the ankle ROM. Passive sagittal and frontal plane motions were measured. The difference in degree between the stimulus point and the reproduced point was defined as an angular error. The measurements were performed at four different phases: pre-taping (PRT), post-taping immediately (POT), post-5 minute walking with taping (P5M), and post-10 minute walking with taping (P10M). The ankle of dominant limb was taped by a certified athletic trainer using a closed basket weave technique. Participants walked on the treadmill at 2.5 mph. The results showed that the mean of the sagittal plane motion at PRT, POT, P5M, and P10M was 53.0, 30.5, 36.2, and 40.2 degrees, respectively. The frontal plane motion at PRT, POT, P5M, and P10M was 33.6, 13.9, 15.7, and 18.6 degrees, respectively. The angular error at PRT, POT, P5M, and P10M was 5.5, 1.6, 1.8, and 1.9 degrees, respectively. After 10 minutes of walking, the sagittal plane motion and frontal plane motion was increased by 9.7 and 4.7 degrees compared with POT, respectively. The proprioception was significantly improved after the application of ankle taping. Both the restriction of frontal plane motion and proprioception improvement at the ankle joint may contribute to ankle stability during walking.

  • PDF

A Study of Measurement Methods for Subtalar Joint Motion (목말밑관절 가동범위 측정방법에 관한 연구)

  • Kim, Gi-Won;Hong, Wan-Sung
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.4
    • /
    • pp.57-64
    • /
    • 2010
  • Purpose: This study aimed to determine whether there are differences in subtalar joint range of motion (ROM) when using different measurement methods, and to determine inter- and intra-rater reliability of goniometry as used in clinical setting. Methods: Subjects were thirty-one healthy males and females (sixty-two ankles) living in Korea. Three raters with different clinical experiences measured inversion and eversion range of motion of the subtalar joint two times. Measurements were done with subjects prone (open kinetic chain) and standing (closed kinetic chain). Rater and measurement methods were based on analyzing differences in range of motion. Intra-class correlation coefficients (ICCs) were calculated to determine intra-rater and inter-rater reliability. Results: Mean subtalar jont range of motion for inversion ranged from $9.31^{\circ}$ to $11.94^{\circ}$ for eversion, it ranged from $6.73^{\circ}$ to $9.20^{\circ}$. The differences in ROM between raters and between measurement methods were significant (p<0.01). The ICCs for interrater reliability ranged from $0.02^{\circ}$ to $0.20^{\circ}$ for inversion and from $0.23^{\circ}$ to $0.39^{\circ}$ for eversion. Intrarater reliability ranged from $0.32^{\circ}$ to $0.78^{\circ}$ for inversion and from $0.45^{\circ}$ to $0.73^{\circ}$ for eversion. Conclusion: Subtalar joint inversion and eversion ROM show differences for measurement methods low reliability between different raters, and low to high intra-rater reliability within sessions.

Immobilization of Lactobionic Acid on Polyurethane Films and Their Interaction with Hepatocytes

  • Meng Wan;Jung Kyung-Hye;Kang Inn-Kyu;Kwon Oh Hyeong;Akaike Toshihiro
    • Macromolecular Research
    • /
    • v.13 no.3
    • /
    • pp.257-264
    • /
    • 2005
  • Polyurethanes containing z-Iysine segments in the main chain (PULL) were synthesized from 4,4'-diphe-nylmethyl diisocyanate, poly(tetramethylene glycol), and z-Iysine oligomer as a chain extender. The PULL film was treated first with a $10\%$ HBr-acetic acid solution and subsequently with a saturated sodium bicarbonate aqueous solution to produce a primary amine group on the surface (PULL-N). Lactobionic acid (LA)-immobilized PULL (PULL-L) was prepared by the coupling reaction of the PULL surface amine groups and the LA carboxylic acid groups. The surface-modified PULLs were then characterized by attenuated total reflection-Fourier transform infra-red spectroscopy, electron spectroscopy for chemical analysis, atomic force microscopy, and contact angle goniometry. In the hepatocytes adhesion experiment, the cells poorly adhered to the PULL surface, although they adhered moderately well to the PULL-N surface. On the other hand, the cells adhered well to the PULL-L surface, suggesting the good affinity of the surface $\beta$-galactose moieties for hepatocytes. When hepatocytes were cultured in the presence of epidermal growth factor for 48 h, the cells rapidly aggregated on the PULL-L surface, whereas they aggregated only slowly on the other surfaces. The PULL prepared in this study has the potential to be used as a coating material for the enhancement of hepatocyte adhesion.

Association between dynamic balance and ankle muscle characteristics (동적 균형과 발목 근육 특성 사이의 관계)

  • Jung, Sung-hoon;Jeon, In-cheol;Ha, Sungmin
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.11
    • /
    • pp.217-223
    • /
    • 2019
  • The relationship between balance and ankle muscle characteristics (strength and flexibility) may be important to identify those at an increased risk of falling and to develop fall-prevention training programs. The association between ankle muscle characteristics (strength and flexibility) and balance has not previously been studied. The purpose of this study assessed the relationship between ankle muscle characteristics and balance. Sixteen healthy participants volunteered to participate in the study. Dynamic balance measured using Y-balance kit. Ankle muscle characteristics (strength and flexibility) measured using hand-held dynamometer and goniometry. The results indicated a positive correlation between ankle invertor muscle strength and Y-balance test performance. Clinicians should consider ankle muscle strength during therapeutic interventions to improve dynamic balance.

Specific Binding of Streptavidin onto the Nonbiofouling Titanium/Titanium Oxide Surface through Surface-Initiated, Atom Transfer Radical Polymerization and Bioconjugation of Biotin

  • Kang, Sung-Min;Lee, Bong-Soo;Kim, Wan-Joong;Choi, In-Sung S.;Kil, Mun-Jae;Jung, Hyuk-Jun;Oh, Eu-Gene
    • Macromolecular Research
    • /
    • v.17 no.3
    • /
    • pp.174-180
    • /
    • 2009
  • Chemical modification of titanium/titanium oxide (Ti/$TiO_2$) substrates has recently gained a great deal of attention because of the applications of Ti/$TiO_2$-based materials to biomedical areas. The reported modification methods generally involve passive coating of Ti/$TiO_2$ substrates with protein-resistant materials, and poly(ethylene glycol) (PEG) has proven advantageous for bestowing a nonbiofouling property on the surface of Ti/$TiO_2$. However, the wider applications of Ti/$TiO_2$ based materials to biomedical areas will require the introduction of biologically active moieties onto Ti/$TiO_2$, in addition to nonbiofouling property. In this work, we therefore utilized surface-initiated polymerization to coat the Ti/$TiO_2$ substrates with polymers presenting the nonbiofouling PEG moiety and subsequently conjugated biologically active compounds to the PEG-presenting, polymeric films. Specifically, a Ti/$TiO_2$ surface was chemically modified to present an initiator for atom transfer radical polymerization, and poly(ethylene glycol) methacrylate (pEGMA) was polymerized from the surface. After activation of hydroxyl groups of poly(pEGMA) (pPEGMA) with N,N'-disuccinimidyl carbonate, biotin, a model compound, was conjugated to the pPEGMA films. The reactions were confirmed by infrared spectroscopy, X-ray photoelectron spectroscopy, contact angle goniometry, and ellipsometry. The biospecific binding of target proteins was also utilized to generate micropatterns of proteins on the Ti/$TiO_2$ surface.

Effects of Scapular Taping on Muscle Activity, Pain, Range of Motion and Proprioception in Subacute Stroke Patients (아급성 편마비환자의 어깨관절 Scapular Taping적용이 근 활성도와 통증, 관절가동범위 및 고유수용성감각에 미치는 영향)

  • Lee, Jae-Nam;Lim, Chae-Gil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5689-5697
    • /
    • 2013
  • The purpose of this study was to determine the effects of scapular taping on muscle activities of the scapular rotators and anterior deltoid, ROM, shoulder pain, proprioception in subacute stroke patients. Twenty-eight patients were randomly assigned to an experimental and control groups of fourteen patients respectively. Muscle activity of upper and lower trapezius, serratus anterior, anterior deltoid was measured using surface electromyography. Visual analog scale was used for shoulder pain. Electro-Goniometry was used for shoulder elevation ROM. Assessment board was used for shoulder elevation proprioception. The muscle activity of the lower trapezius and serratus anterior increased significantly after scapular tape application (p<0.05). The AROM and PROM in the shoulder elevation significantly increased after scapular tape application (p<0.05). The VAS in the shoulder no significantly decreased after scapular tape application (p>0.05). The proprioception in the shoulder no significantly increased after scapular tape application (p>0.05). The results of this study suggest that scapular taping can be used an additional therapy for increasing muscle activity of lower trapezius and serratus anterior and ROM during shoulder elevation in subacute stroke patients.

Reliability Analysis of Finger Joint Range of Motion Measurements in Wearable Soft Sensor Gloves (웨어러블 소프트 센서 장갑의 손가락 관절 관절가동범위 측정에 대한 신뢰도 분석)

  • Eun-Kyung Kim;Jin-Hong Kim;Yu-Ri Kim;Ye-Ji Hong;Gang-Pyo Lee;Eun-Hye Jeon;Joon-bum Bae;Su-in Kim;Sang-Yi Lee
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose: The purpose of this study was to compare universal goniometry (UG), which is commonly used in clinical practice to measure the range of motion (ROM) of finger joints with a wearable soft sensor glove, and to analyze the reliability to determine its usefulness. Methods: Ten healthy adults (6 males, 4 females) participated in this study. The metacarpophalangeal joint (MCP), interphalangeal joint (IP), and proximal interphalangeal joint (PIP) of both hands were measured using UG and Mollisen HAND soft sensor gloves during active flexion, according to the American Society for Hand Therapists' measurement criteria. Measurements were taken in triplicate and averaged. The mean and standard deviation of the two methods were calculated, and the 95% limits of agreement (LOA) of the measurements were calculated using the intraclass correlation coefficient (ICC) and Bland-Altman plot to examine the reliability and discrepancies between the measurements. Results: The results of the mean values of the flexion angles for the active range of motion (AROM) of the finger joints showed large angular differences in the finger joints, except for the MCP of the thumb. In the inter-rater reliability analysis according to the measurement method, the ICC (2, 1) value showed a low level close to 0, and the mean difference by the Bland-Altman plot showed a value greater than 0, showing a pattern of discrepancy. The 95% LOA had a wide range of differences. Conclusion: This study is a preliminary study investigating the usefulness of the soft sensor glove, and the reliability analysis showed a low level of reliability and inconsistency. However, if future studies can overcome the limitations of this study and the technical problems of the soft sensor glove in the development stage, it is suggested that the measurement instrument can show more accurate measurement and higher reliability when measuring ROM with UG.