• 제목/요약/키워드: Goniometry

검색결과 18건 처리시간 0.024초

흉추 도수교정이 둥근어깨자세를 가진 30대 성인남녀의 통증, 관절가동범위, 근활성도에 미치는 영향 (The Effects of Thoracic Spine Thrust Manipulation on Shoulder Pain, Range of Motion and Muscle Activity in 30′s Adults with Rounded Shoulder Posture)

  • 이재남;양성화;공원태
    • 대한정형도수물리치료학회지
    • /
    • 제22권1호
    • /
    • pp.17-25
    • /
    • 2016
  • Purpose: This study was aimed to determine the effects of thoracic spine thrust manipulation on muscle activities of the scapular upward rotators and middle deltoid, active range of motion (AROM), shoulder pain, and rounded shoulder posture in young adults with rounded shoulder. Methods: The subjects were 30 young adults (14 males, 16 females) with rounded shoulder. Thirty subjects were randomly assigned to an experimental (manipulation) and control (placebo) groups of fifteen subjects respectively. The manipulation group received the manipulation (high velocity, low amplitude), which was performed by a physical therapist with the subject in the supine position and with the arms crossed over the chest and hands passed over the shoulders. For the sham group, the same procedure was performed, with the exception that the high-velocity thrust was not applied. Measurements were taken before and after the intervention. Muscle activity of upper and lower trapezius, serratus anterior, middle deltoid was measured using surface electromyography. Visual analog scale (VAS) was used for shoulder pain. Goniometry was used for shoulder abduction active range of motion (AROM). Straight edge was used for supine rounded shoulder posture (RSP) distance. Results: The muscle activity of the upper trapezius, lower trapezius and middle deltoid muscle increased significantly after the intervention (p<.05). However, no significant difference was observed in serratus anterior muscle (p>.05). The VAS was significantly decreased and AROM significantly increased after the intervention (p<.05). The distance of RSP were not significant (p>.05). The control group showed no differences before and after the intervention (p>.05). Conclusion: The results of this study suggest that thoracic spine thrust manipulation can be an effective component of treatment plan to improve pain and function.

  • PDF

테이핑이 발목의 관절가동범위와 고유수용성감각에 미치는 영향 (The Effect of Taping on the Range of Motion and Proprioception at the Ankle Joint)

  • 김창인;권오윤;이충휘
    • 한국전문물리치료학회지
    • /
    • 제8권3호
    • /
    • pp.43-52
    • /
    • 2001
  • This study was designed to determine the effect of ankle taping and short period of walking on the treadmill on the range of motion (ROM) and proprioception at the ankle joint. Twenty healthy male subjects (mean age=24.2 yr) participated in this study. Goniometry and videotape replaying method were used to measure the ankle ROM. Passive sagittal and frontal plane motions were measured. The difference in degree between the stimulus point and the reproduced point was defined as an angular error. The measurements were performed at four different phases: pre-taping (PRT), post-taping immediately (POT), post-5 minute walking with taping (P5M), and post-10 minute walking with taping (P10M). The ankle of dominant limb was taped by a certified athletic trainer using a closed basket weave technique. Participants walked on the treadmill at 2.5 mph. The results showed that the mean of the sagittal plane motion at PRT, POT, P5M, and P10M was 53.0, 30.5, 36.2, and 40.2 degrees, respectively. The frontal plane motion at PRT, POT, P5M, and P10M was 33.6, 13.9, 15.7, and 18.6 degrees, respectively. The angular error at PRT, POT, P5M, and P10M was 5.5, 1.6, 1.8, and 1.9 degrees, respectively. After 10 minutes of walking, the sagittal plane motion and frontal plane motion was increased by 9.7 and 4.7 degrees compared with POT, respectively. The proprioception was significantly improved after the application of ankle taping. Both the restriction of frontal plane motion and proprioception improvement at the ankle joint may contribute to ankle stability during walking.

  • PDF

목말밑관절 가동범위 측정방법에 관한 연구 (A Study of Measurement Methods for Subtalar Joint Motion)

  • 김기원;홍완성
    • The Journal of Korean Physical Therapy
    • /
    • 제22권4호
    • /
    • pp.57-64
    • /
    • 2010
  • Purpose: This study aimed to determine whether there are differences in subtalar joint range of motion (ROM) when using different measurement methods, and to determine inter- and intra-rater reliability of goniometry as used in clinical setting. Methods: Subjects were thirty-one healthy males and females (sixty-two ankles) living in Korea. Three raters with different clinical experiences measured inversion and eversion range of motion of the subtalar joint two times. Measurements were done with subjects prone (open kinetic chain) and standing (closed kinetic chain). Rater and measurement methods were based on analyzing differences in range of motion. Intra-class correlation coefficients (ICCs) were calculated to determine intra-rater and inter-rater reliability. Results: Mean subtalar jont range of motion for inversion ranged from $9.31^{\circ}$ to $11.94^{\circ}$ for eversion, it ranged from $6.73^{\circ}$ to $9.20^{\circ}$. The differences in ROM between raters and between measurement methods were significant (p<0.01). The ICCs for interrater reliability ranged from $0.02^{\circ}$ to $0.20^{\circ}$ for inversion and from $0.23^{\circ}$ to $0.39^{\circ}$ for eversion. Intrarater reliability ranged from $0.32^{\circ}$ to $0.78^{\circ}$ for inversion and from $0.45^{\circ}$ to $0.73^{\circ}$ for eversion. Conclusion: Subtalar joint inversion and eversion ROM show differences for measurement methods low reliability between different raters, and low to high intra-rater reliability within sessions.

Immobilization of Lactobionic Acid on Polyurethane Films and Their Interaction with Hepatocytes

  • Meng Wan;Jung Kyung-Hye;Kang Inn-Kyu;Kwon Oh Hyeong;Akaike Toshihiro
    • Macromolecular Research
    • /
    • 제13권3호
    • /
    • pp.257-264
    • /
    • 2005
  • Polyurethanes containing z-Iysine segments in the main chain (PULL) were synthesized from 4,4'-diphe-nylmethyl diisocyanate, poly(tetramethylene glycol), and z-Iysine oligomer as a chain extender. The PULL film was treated first with a $10\%$ HBr-acetic acid solution and subsequently with a saturated sodium bicarbonate aqueous solution to produce a primary amine group on the surface (PULL-N). Lactobionic acid (LA)-immobilized PULL (PULL-L) was prepared by the coupling reaction of the PULL surface amine groups and the LA carboxylic acid groups. The surface-modified PULLs were then characterized by attenuated total reflection-Fourier transform infra-red spectroscopy, electron spectroscopy for chemical analysis, atomic force microscopy, and contact angle goniometry. In the hepatocytes adhesion experiment, the cells poorly adhered to the PULL surface, although they adhered moderately well to the PULL-N surface. On the other hand, the cells adhered well to the PULL-L surface, suggesting the good affinity of the surface $\beta$-galactose moieties for hepatocytes. When hepatocytes were cultured in the presence of epidermal growth factor for 48 h, the cells rapidly aggregated on the PULL-L surface, whereas they aggregated only slowly on the other surfaces. The PULL prepared in this study has the potential to be used as a coating material for the enhancement of hepatocyte adhesion.

동적 균형과 발목 근육 특성 사이의 관계 (Association between dynamic balance and ankle muscle characteristics)

  • 정성훈;전인철;하성민
    • 한국융합학회논문지
    • /
    • 제10권11호
    • /
    • pp.217-223
    • /
    • 2019
  • 균형과 발목 근육 특성 (근력과 유연성) 사이의 관계는 낙상 위험의 증가에 대한 규명과 낙상방지 훈련프로그램을 발전시키기 위해서 중요할 것이다. 발목 근육 특성(근력과 유연성)과 균형사이의 관계는 이전에 연구되지 않았다. 이 연구의 목적은 발목근육특성과 균형사이의 관계를 평가하는 것이다. 16명의 건강한 참가자들이 본 연구에 자원하였다. 동적 균형은 와이-발란스 (Y-balance) 키트를 이용하여 측정하였다. 발목 근육 특성 (근력과 유연성)은 악력계와 고니어미터를 사용하여 측정하였다. 발목내번근력과 와이-발란스 (Y-balance) 측정 수행능력 사이에 양의 상관관계를 나타냈다. 임상가들은 동적균형의 발전을 위해서 치료적 중재를 하는 동안 발목 근력을 고려해야 한다.

Specific Binding of Streptavidin onto the Nonbiofouling Titanium/Titanium Oxide Surface through Surface-Initiated, Atom Transfer Radical Polymerization and Bioconjugation of Biotin

  • Kang, Sung-Min;Lee, Bong-Soo;Kim, Wan-Joong;Choi, In-Sung S.;Kil, Mun-Jae;Jung, Hyuk-Jun;Oh, Eu-Gene
    • Macromolecular Research
    • /
    • 제17권3호
    • /
    • pp.174-180
    • /
    • 2009
  • Chemical modification of titanium/titanium oxide (Ti/$TiO_2$) substrates has recently gained a great deal of attention because of the applications of Ti/$TiO_2$-based materials to biomedical areas. The reported modification methods generally involve passive coating of Ti/$TiO_2$ substrates with protein-resistant materials, and poly(ethylene glycol) (PEG) has proven advantageous for bestowing a nonbiofouling property on the surface of Ti/$TiO_2$. However, the wider applications of Ti/$TiO_2$ based materials to biomedical areas will require the introduction of biologically active moieties onto Ti/$TiO_2$, in addition to nonbiofouling property. In this work, we therefore utilized surface-initiated polymerization to coat the Ti/$TiO_2$ substrates with polymers presenting the nonbiofouling PEG moiety and subsequently conjugated biologically active compounds to the PEG-presenting, polymeric films. Specifically, a Ti/$TiO_2$ surface was chemically modified to present an initiator for atom transfer radical polymerization, and poly(ethylene glycol) methacrylate (pEGMA) was polymerized from the surface. After activation of hydroxyl groups of poly(pEGMA) (pPEGMA) with N,N'-disuccinimidyl carbonate, biotin, a model compound, was conjugated to the pPEGMA films. The reactions were confirmed by infrared spectroscopy, X-ray photoelectron spectroscopy, contact angle goniometry, and ellipsometry. The biospecific binding of target proteins was also utilized to generate micropatterns of proteins on the Ti/$TiO_2$ surface.

아급성 편마비환자의 어깨관절 Scapular Taping적용이 근 활성도와 통증, 관절가동범위 및 고유수용성감각에 미치는 영향 (Effects of Scapular Taping on Muscle Activity, Pain, Range of Motion and Proprioception in Subacute Stroke Patients)

  • 이재남;임재길
    • 한국산학기술학회논문지
    • /
    • 제14권11호
    • /
    • pp.5689-5697
    • /
    • 2013
  • 본 연구는 뇌졸중으로 인한 아급성 편마비 환자의 견관절 거상 시 scapular taping 적용이 견갑골 상방 회전근과 전 삼각근의 근 활성도와 통증, 관절가동범위, 그리고 고유수용성감각에 미치는 영향을 알아보기 위하여 실시하였다. 28명을 대상으로 실험군과 대조군으로 나눠 테이핑 전과 후의 상승모근, 하승모근, 전거근 그리고 전 삼각근의 근 활성도를 측정하였다. 그리고 견관절 관절가동범위와 통증, 고유수용성 감각을 측정하였다. 실험결과 근 활성도는 하승모근과 전거근에서 scapular taping 적용 시 유의하게 증가하였으며(p<0.05), 관절가동범위는 유의한 차이가 있었다(p<0.05). 그러나 통증과 고유수용성 감각은 유의한 차이가 없었다(p>0.05). 본 연구 결과 견관절을 거상하는 동안 아급성편마비 환자들에게 적용한 scapular taping은 견갑골 상방회전근의 근 활성도를 증가시키고 관절가동범위를 증가시키는데 부가적인 치료 방법으로 활용될 수 있을 것이다.

웨어러블 소프트 센서 장갑의 손가락 관절 관절가동범위 측정에 대한 신뢰도 분석 (Reliability Analysis of Finger Joint Range of Motion Measurements in Wearable Soft Sensor Gloves)

  • 김은경;김진홍;김유리;홍예지;이강표;전은혜;배준범;김수인;이상이
    • PNF and Movement
    • /
    • 제21권2호
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose: The purpose of this study was to compare universal goniometry (UG), which is commonly used in clinical practice to measure the range of motion (ROM) of finger joints with a wearable soft sensor glove, and to analyze the reliability to determine its usefulness. Methods: Ten healthy adults (6 males, 4 females) participated in this study. The metacarpophalangeal joint (MCP), interphalangeal joint (IP), and proximal interphalangeal joint (PIP) of both hands were measured using UG and Mollisen HAND soft sensor gloves during active flexion, according to the American Society for Hand Therapists' measurement criteria. Measurements were taken in triplicate and averaged. The mean and standard deviation of the two methods were calculated, and the 95% limits of agreement (LOA) of the measurements were calculated using the intraclass correlation coefficient (ICC) and Bland-Altman plot to examine the reliability and discrepancies between the measurements. Results: The results of the mean values of the flexion angles for the active range of motion (AROM) of the finger joints showed large angular differences in the finger joints, except for the MCP of the thumb. In the inter-rater reliability analysis according to the measurement method, the ICC (2, 1) value showed a low level close to 0, and the mean difference by the Bland-Altman plot showed a value greater than 0, showing a pattern of discrepancy. The 95% LOA had a wide range of differences. Conclusion: This study is a preliminary study investigating the usefulness of the soft sensor glove, and the reliability analysis showed a low level of reliability and inconsistency. However, if future studies can overcome the limitations of this study and the technical problems of the soft sensor glove in the development stage, it is suggested that the measurement instrument can show more accurate measurement and higher reliability when measuring ROM with UG.