• 제목/요약/키워드: Gold coping

검색결과 16건 처리시간 0.023초

임플랜트 지대주와 주조 금합금과의 접합 및 부식에 관한 연구 (A STUDY OF INTERFACE AND CORROSION BEHAVIOR BETWEEN IMPLANT ABUTMENT AND CASTING GOLD ALLOY)

  • 손미경;마장선;정재헌
    • 대한치과보철학회지
    • /
    • 제37권5호
    • /
    • pp.672-686
    • /
    • 1999
  • The purpose of this study was to compare the casting problem and corrosion behavior in two types of HL Hexed abutments of the Steri-Oss system ; gold/plastic coping and gold coping. The anodic Polarization behavior, the galvanic corrosion between abutments and Type III gold alloys, before and after casting were analyzed, and the crevice corrosion of casting samples was analyzed with the CPPT test and the SEM. The results are as follows : 1. Anodic polarization behavior of samples ; Before casting, gold/plastic coping and gold coping was shown to have a similar corrosion pat-terns. Type III casting gold alloy was shown to have a lower corrosion potential and passivation film. Corrosion potential of the case of gold/plastic coping after casting was higher than that of gold coping, but the region of passivation film for gold/plastic coping was smaller than that of gold coping. 2. Galvanic corrosion behavior of samples ; Contact current density between casting gold alloys and gold/plastic before casting was higher than that between gold coping and casting gold alloy Galvanic corrosion of samples after casting was shown to have similar contact current density 3. Crevice corrosion behavior of samples ; Crevice corrosion resistance of casting sample using gold coping was lower than that of cast-ing sample using gold/plastic coping, and a severe corrosion pattern was observed at the abutment-casting gold alloy interface by the SEM.

  • PDF

A qualitative analysis of bonding between electroformed surface and veneering ceramics

  • Kwon, Ho-Beom;Yim, Soon-Ho
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.328-335
    • /
    • 2000
  • Statement of the problem. Recently an innovative method of fabricating indirect restorations by gold electroforming has been developed. But the bond quality and strength of the gold coping to the porcelain is uncertain. Purpose of study. The purpose of this study is to analyze and evaluate the electroformed gold surface for mechanical bonding between the gold and the ceramic veneering. Methods/material. Electroformed disks were made using electroforming technique. And the surface of the electroformed coping was analyzed after sandblasting, heat-treatment, bonding agent application, opaque porcelain firing with scanning electron microscopy and energy dispersive x-ray analysis. Results. In the analysis with SEM, Sandblasting made the sharp edges and undercuts on the electroformed surface, and after bonding agent application, net-like structure were created on the electroformed surface. In the energy dispersive x-ray analysis it is confirmed that electroformed surface contains some impurities. Conclusion. With the use of sandblasting and bonding agent, electroformed surface seems to be enough to bond with veneering porcelain.

  • PDF

심미도재관의 파절 강도 비교 연구 (A comparative study on the fracture strength of esthetic porcelain crowns)

  • 김은하;이명곤
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.79-85
    • /
    • 2007
  • In this study, We tried to find out the fracture strength of zirconia coping all ceramic crown and collarless porcelain fused gold alloy crown as the compared group. Each of the collarless porcelain fused gold crown and zirconia all ceramic crown has been produced specimen 10 each. And after pasting them on the steel jig, it had load given at porcelain incisal edge by 130$^{\circ}$ and measured fracture strength by Universal Testing Machine and then We have results from that. 1. The average value of fracture strength suggested 950.49 N at collarless porcelain fused gold alloy crown, 656.81 N at zirconia coping all ceramic crown. 2. Fractured pattern showed that the whole of labial part was exposed in collarless porcelain fused gold crown, but porcelain of margin part did not show fracture in advance. In the practice, the concern that collarless might cause fracture strength to be weaken does not matter, we concluded zirconia all ceramic crown made fracture that only a part of labial porcelain was fractured. The combination of zirconia all ceramic crown and turned out to be excellent.

  • PDF

Effect of abutment shade, ceramic thickness, and coping type on the final shade of zirconia all-ceramic restorations: in vitro study of color masking ability

  • Oh, Seon-Hee;Kim, Seok-Gyu
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.368-374
    • /
    • 2015
  • PURPOSE. The aim of the study was to evaluate the effect of abutment shade, ceramic thickness, and coping type on the final shade of zirconia all-ceramic restorations. MATERIALS AND METHODS. Three different types of disk-shaped zirconia coping specimens (Lava, Cercon, Zirkonzahn: ${\phi}10mm{\times}0.4mm$) were fabricated and veneered with IPS e.max Press Ceram (shade A2), for total thicknesses of 1 and 1.5 mm. A total of sixty zirconia restoration specimens were divided into six groups based on their coping types and thicknesses. The abutment specimens (${\phi}10mm{\times}7mm$) were prepared with gold alloy, base metal (nickel-chromium) alloy, and four different shades (A1, A2, A3, A4) of composite resins. The average $L^*$, $a^*$, $b^*$ values of the zirconia specimens on the six abutment specimens were measured with a dental colorimeter, and the statistical significance in the effects of three variables was analyzed by using repeated measures analysis of variance (${\alpha}$=.05).The average shade difference (${\Delta}E$) values of the zirconia specimens between the A2 composite resin abutment and other abutments were also evaluated. RESULTS. The effects of zirconia specimen thickness (P<.001), abutment shade (P<.001), and type of zirconia copings (P<.003) on the final shade of the zirconia restorations were significant. The average ${\Delta}E$ value of Lava specimens (1 mm) between the A2 composite resin and gold alloy abutments was higher (close to the acceptability threshold of 5.5 ${\Delta}E$) than th ose between the A2 composite resin and other abutments. CONCLUSION. This in-vitro study demonstrated that abutment shade, ceramic thickness, and coping type affected the resulting shade of zirconia restorations.

도재전장관용 Coping과 수종 Core간의 시멘트 결합력에 관한 비교 연구 (COMPARATIVE STUDY ON THE BOND STRENGTH OF CEMENTS BETWEEN PFM COPING AND VARIOUS CORES)

  • 백성기;장완식
    • 대한치과보철학회지
    • /
    • 제20권1호
    • /
    • pp.25-32
    • /
    • 1982
  • An in vitro study was conducted to compare the bond strength of cements between Verabond coping and various cores. Fifty-four idential cores simulating maxillary central incisor prepared for PFM crowns were made. Eighteen samples were made with 20K cast gold, eighteen with Verabond, and eighteen with Adaptic. Samples were randomly divided into three groups, each consisting of six 20K cast gold, six verabond, and six Adaptic samples. The first group was cemented with zinc phosphate cement, the second group with poly-carboxylate cement, and the third group with glass ionomer cement. Constant finger pressure was applied for cementation. The sample were then stored at $37^{\circ}C$ in distilled water bath for 24 hours. The tensile strength test was performed on an Instron Universal test machine with crosshead speed of 0.05cm/min and the results compared statistically. Results of the study showed that: 1. A significant difference of bond strength was observed with different types of dental cements and core materials. 2. With gold core, zinc phosphate cement was stronger than both the polycarboxylate cement and glass ionomer cement, which did not differ in bond strength. 3. With base-metal core, zinc phosphate cement showed the highest bond strength and was followed by polycarboxylate cement and glass ionomer cement. 4. With composite resin core, zinc phosphate cement showed the highest bond strength and was followed by glass ionomer cement and polycarboxylate cement. 5. The base-metal core (Verabond core) privided the highest retention of all core materials.

  • PDF

전기도금도재관과 금속도재관의 파절강도 (Fracture Strength of Porcelain Fused to Gold Crown & Gold Electroformed Crown)

  • 박원주;임주환;조인호;임헌송
    • 구강회복응용과학지
    • /
    • 제18권2호
    • /
    • pp.101-111
    • /
    • 2002
  • The purpose of this study was to evaluate the fracture strength of porcelain fused to gold crown and gold electroformed crown according to incisal and incisal under 3mm. In this study, 28 gold electroformed crown and 28 porcelain fused to gold crown were fabricated. Fracture strength testing was carried out using an Instron 8871(Instron Corporation, U.S.A) at a cross head speed of 5mm/min. All of the measurements were statistically analyzed by Independent t-testing, and k-s testing. Statistical significance was set in advance at the probability level of less than 0.05. All measurements were analized with Windows $SPSS^{(R)}$ Version 10.0 software for the personal computer. The results of this study were as follows; 1. Comparison by location (1) A compared fracture strength of incisal and incisal under 3 mm, there was statistical significant difference between gold electro -formed crown and porcelain fused to gold crown (p<0.05). 2. Comparison by loading (1) When compared fracture strength of incisal, there was no significant difference between gold electroformed crown ($619.90{\pm}53.54N$)and porcelain fused to gold crown($674.68{\pm}87.42N$). (2) When compared fracture strength of incisal under 3 mm, there was significant difference between gold electroformed crown($688.29{\pm}14.88N$) and porcelain fused to gold crown($1931.81{\pm}29.64N$) (p<0.05). 3. Mode of fracture When compared of fracture mode, gold electroformed crown showed mode of fracture and fracture line reaching coping region and porcelain fused to gold crown showed only in porcelain region.

민간경호${\cdot}$경비원의 개인적 특성에 따른 직무 스트레스의 반향관계 (The Relationship between Safe guard Accomplishment Personality and Stress Coping Behavior)

  • 공배완;김창호
    • 시큐리티연구
    • /
    • 제10호
    • /
    • pp.15-34
    • /
    • 2005
  • 스트레스는 현대인의 생활과정 중에서 피할 수 없는 일부분이다 .그러나 스트레스를 어떻게 대처하는가 하는 것도 업무의 효율성 측면에 있어서는 매우 중요한 요인이 되고 있다. 다시 말해, 스트레스는 대처행동에 따라 그 효과가 달라진다는 것으로, 동일한 스트레스원에 당면하더라도 개인적인 성격특성에 따라 어떤 사람은 강렬한 스트레스를 경험하기도 하고 또 다른 사람은 미약하거나 경험하지 않기도 한다. 이러한 관점에서 볼 때 개인적인 성격특성은 스트레스 대처행동에 영향을 줄 수 있는 중요한 요인임을 알 수 있다. 따라서 본 연구의 목적은 성격특성과 스트레스 대처행동과의 관계를 규명하고 아울러 성격특성과 스트레스 대처효과 즉, 적응과의 관계를 알아보고자 하는 것이다. 보다 효과적으로 적응할 수 있는 성격특성이 무엇인지를 규명하는 동시에 각 성격특성의 소유자들이 어떤 양식으로 스트레스원에 대처하는가를 밝혀줌으로써, 경호업무 수행자들의 행동을 이해하고 그들의 적응을 지도해 나가는데 필요한 자료를 제공하는데 의의를 두고자 한다.

  • PDF

THE EFFECT OF GOLD ELECTROFORMING PROCEDURE ON GOLD-SILVER-PALLADIUM ALLOY

  • Hwang, Bo-Yeon;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.303-309
    • /
    • 2007
  • Statement of problem. The effect of gold electroforming on gold alloy was not studied. Purpose. This in vitro study investigate the effect of gold electroforming on gold-silver-palladium alloy. Material and methods. Three pieces of gold strips had undergone the electroforming procedures on one side and then half of the side again electroformed. The set mode for this study was program 1 ($200{\mu}m$). And the processing time was 15min (1/20 time to form $200{\mu}m$ coping). The confocal laser scanning microscope (PASCAL 5, Carl Zeiss, Bernried, Germany) was used to measure the thickness of the pure gold layer electroformed on the gold strips. Half of the gold strip was coated two times with electroformed gold, and the other half one time. The data from the cone focal laser system was processed to get the vertical profile of the strips and the difference of the vertical height between the double coated and single coated layer was regarded as the thickness of the gold coating. The layer thickness value to built 3D image of the cone-focal laser was set $0.5{\mu}m$. Next to the measurement of the thickness of the coating, the Vicker's hardness test was done. It was performed on the double coated surface, single coated surface and non-coated surface (back side) three times each. Results. The mean thickness value gained from gold electroforming technique was measured to be $22{\mu}m$ for sample 1, $23{\mu}m$ for sample 2, $21{\mu}m$ for sample 3. In the same condition of time, power and the amount of electrolyte, the data showed no difference between samples. According to the results of variance analysis, the differences among the variations in number of coating were statistically insignificant (p>0.05), meaning that the two times of gold electroforming coating did not change the hardness of gold-silver-palladium alloy. Conclusion. The test of thickness of gold coating proved the coherency of the gold electroforming procedure, in other words, when the power, the exposed surface area, processing time and the amount of electrolytes were set same, the same thickness of gold would be coated on. The hardness test showed that the electroformed gold coating did not change the hardness of the gold-silver-palladium alloy when it is coated not more than $45{\mu}m$.

Gold Electroforming System을 이용한 하악 임플란트 지지 텔레스코프 피개의치 (Mandibular Implant-Supported Telescopic Overdenture using Gold Electroforming System : A Case Report)

  • 최지하;김승균;유병일;안승근;박주미;송광엽;박찬운
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.193-201
    • /
    • 2008
  • 하악 완전 무치악 환자의 보철수복에 있어 임플란트 식립 후 피개의치의 제작은 첫 번째 치료 옵션으로 고려되어질 수 있다. 임플란트 지지 텔레스코프 피개의치를 제작하는 경우 인공치 및 유지 장치의 배열을 위한 악간 공간이 필요하다. 임플란트 상부 보철물의 passive한 fit은 보철물의 기계적 실패를 막는 중요한 요소이다. Gold electroforming system을 이용하여 제작한 telescopic attachment는 우수한 마진 적합도 및 passive한 fit을 보이며 얇은 코핑 두께로 인하여 좁은 악간 공간에서도 사용이 가능한 장점이 있다. 본 증례에서는 4개의 임플란트 식립 후 Gold electroforming system을 이용하여 telescopic overdenture를 제작하여 기능 및 심미적으로 좋은 결과를 나타내었다.

전기방전가공법을 이용한 임플랜트 보철물의 적합도 연구 (A STUDY ON THE FIT OF IMPLANT-RETAINED PROSTHESES USING ELECTRIC DISCHARGE MACHINING)

  • 한의택;김영수;김창회;양재호
    • 대한치과보철학회지
    • /
    • 제39권1호
    • /
    • pp.1-13
    • /
    • 2001
  • An absolutely passive fit at the interface with the superstructure and the abutment cylinders is need for implant longevity. In this study, a method of cast framework correction using spark erosion technology was evaluated. Electric discharge machining(EDM) is a process that uses electrical discharges, or sparks, to machine metal, The surface being machined is bombared with high-intensity electrical energy pulses that gradually melt away the stock until the desired configuration is obtained. Master model was fabricated by using metal block impression analogue, which fired 5 Branemark squared impression coping in an arc shaped metal block. Then framework using 4mm standard gold cylinder and type IV gold alloy was fabricated. In order to measure the fit of the framework we used both contact and noncontact coordinate measurement machine and data was processed by computer program. After superimposition of gold framework and master model numeric image data the distances between gold cylinder bearing surfaces and abutment replica bearing surfaces, and the angle deviations between gold cylinder and abutment replica centroid points were calculated. The results were as follows 1 The total mean distance (p<0.01) and standard deviation (p<0.001) between the gold cylinders and abutment bearing surfaces were significantly decreased after EDM 2. The total mean of maximum distances was significantly decreased after EDM (p<0.05). 3. After EDM, the mean angle deviation between centroid points was decreased.

  • PDF