The purpose of this study was to compare the casting problem and corrosion behavior in two types of HL Hexed abutments of the Steri-Oss system ; gold/plastic coping and gold coping. The anodic Polarization behavior, the galvanic corrosion between abutments and Type III gold alloys, before and after casting were analyzed, and the crevice corrosion of casting samples was analyzed with the CPPT test and the SEM. The results are as follows : 1. Anodic polarization behavior of samples ; Before casting, gold/plastic coping and gold coping was shown to have a similar corrosion pat-terns. Type III casting gold alloy was shown to have a lower corrosion potential and passivation film. Corrosion potential of the case of gold/plastic coping after casting was higher than that of gold coping, but the region of passivation film for gold/plastic coping was smaller than that of gold coping. 2. Galvanic corrosion behavior of samples ; Contact current density between casting gold alloys and gold/plastic before casting was higher than that between gold coping and casting gold alloy Galvanic corrosion of samples after casting was shown to have similar contact current density 3. Crevice corrosion behavior of samples ; Crevice corrosion resistance of casting sample using gold coping was lower than that of cast-ing sample using gold/plastic coping, and a severe corrosion pattern was observed at the abutment-casting gold alloy interface by the SEM.
Statement of the problem. Recently an innovative method of fabricating indirect restorations by gold electroforming has been developed. But the bond quality and strength of the gold coping to the porcelain is uncertain. Purpose of study. The purpose of this study is to analyze and evaluate the electroformed gold surface for mechanical bonding between the gold and the ceramic veneering. Methods/material. Electroformed disks were made using electroforming technique. And the surface of the electroformed coping was analyzed after sandblasting, heat-treatment, bonding agent application, opaque porcelain firing with scanning electron microscopy and energy dispersive x-ray analysis. Results. In the analysis with SEM, Sandblasting made the sharp edges and undercuts on the electroformed surface, and after bonding agent application, net-like structure were created on the electroformed surface. In the energy dispersive x-ray analysis it is confirmed that electroformed surface contains some impurities. Conclusion. With the use of sandblasting and bonding agent, electroformed surface seems to be enough to bond with veneering porcelain.
In this study, We tried to find out the fracture strength of zirconia coping all ceramic crown and collarless porcelain fused gold alloy crown as the compared group. Each of the collarless porcelain fused gold crown and zirconia all ceramic crown has been produced specimen 10 each. And after pasting them on the steel jig, it had load given at porcelain incisal edge by 130$^{\circ}$ and measured fracture strength by Universal Testing Machine and then We have results from that. 1. The average value of fracture strength suggested 950.49 N at collarless porcelain fused gold alloy crown, 656.81 N at zirconia coping all ceramic crown. 2. Fractured pattern showed that the whole of labial part was exposed in collarless porcelain fused gold crown, but porcelain of margin part did not show fracture in advance. In the practice, the concern that collarless might cause fracture strength to be weaken does not matter, we concluded zirconia all ceramic crown made fracture that only a part of labial porcelain was fractured. The combination of zirconia all ceramic crown and turned out to be excellent.
PURPOSE. The aim of the study was to evaluate the effect of abutment shade, ceramic thickness, and coping type on the final shade of zirconia all-ceramic restorations. MATERIALS AND METHODS. Three different types of disk-shaped zirconia coping specimens (Lava, Cercon, Zirkonzahn: ${\phi}10mm{\times}0.4mm$) were fabricated and veneered with IPS e.max Press Ceram (shade A2), for total thicknesses of 1 and 1.5 mm. A total of sixty zirconia restoration specimens were divided into six groups based on their coping types and thicknesses. The abutment specimens (${\phi}10mm{\times}7mm$) were prepared with gold alloy, base metal (nickel-chromium) alloy, and four different shades (A1, A2, A3, A4) of composite resins. The average $L^*$, $a^*$, $b^*$ values of the zirconia specimens on the six abutment specimens were measured with a dental colorimeter, and the statistical significance in the effects of three variables was analyzed by using repeated measures analysis of variance (${\alpha}$=.05).The average shade difference (${\Delta}E$) values of the zirconia specimens between the A2 composite resin abutment and other abutments were also evaluated. RESULTS. The effects of zirconia specimen thickness (P<.001), abutment shade (P<.001), and type of zirconia copings (P<.003) on the final shade of the zirconia restorations were significant. The average ${\Delta}E$ value of Lava specimens (1 mm) between the A2 composite resin and gold alloy abutments was higher (close to the acceptability threshold of 5.5 ${\Delta}E$) than th ose between the A2 composite resin and other abutments. CONCLUSION. This in-vitro study demonstrated that abutment shade, ceramic thickness, and coping type affected the resulting shade of zirconia restorations.
An in vitro study was conducted to compare the bond strength of cements between Verabond coping and various cores. Fifty-four idential cores simulating maxillary central incisor prepared for PFM crowns were made. Eighteen samples were made with 20K cast gold, eighteen with Verabond, and eighteen with Adaptic. Samples were randomly divided into three groups, each consisting of six 20K cast gold, six verabond, and six Adaptic samples. The first group was cemented with zinc phosphate cement, the second group with poly-carboxylate cement, and the third group with glass ionomer cement. Constant finger pressure was applied for cementation. The sample were then stored at $37^{\circ}C$ in distilled water bath for 24 hours. The tensile strength test was performed on an Instron Universal test machine with crosshead speed of 0.05cm/min and the results compared statistically. Results of the study showed that: 1. A significant difference of bond strength was observed with different types of dental cements and core materials. 2. With gold core, zinc phosphate cement was stronger than both the polycarboxylate cement and glass ionomer cement, which did not differ in bond strength. 3. With base-metal core, zinc phosphate cement showed the highest bond strength and was followed by polycarboxylate cement and glass ionomer cement. 4. With composite resin core, zinc phosphate cement showed the highest bond strength and was followed by glass ionomer cement and polycarboxylate cement. 5. The base-metal core (Verabond core) privided the highest retention of all core materials.
Park, Won-Ju;Lim, Ju-Hwan;Cho, In-Ho;Lim, Heon-Song
Journal of Dental Rehabilitation and Applied Science
/
v.18
no.2
/
pp.101-111
/
2002
The purpose of this study was to evaluate the fracture strength of porcelain fused to gold crown and gold electroformed crown according to incisal and incisal under 3mm. In this study, 28 gold electroformed crown and 28 porcelain fused to gold crown were fabricated. Fracture strength testing was carried out using an Instron 8871(Instron Corporation, U.S.A) at a cross head speed of 5mm/min. All of the measurements were statistically analyzed by Independent t-testing, and k-s testing. Statistical significance was set in advance at the probability level of less than 0.05. All measurements were analized with Windows $SPSS^{(R)}$ Version 10.0 software for the personal computer. The results of this study were as follows; 1. Comparison by location (1) A compared fracture strength of incisal and incisal under 3 mm, there was statistical significant difference between gold electro -formed crown and porcelain fused to gold crown (p<0.05). 2. Comparison by loading (1) When compared fracture strength of incisal, there was no significant difference between gold electroformed crown ($619.90{\pm}53.54N$)and porcelain fused to gold crown($674.68{\pm}87.42N$). (2) When compared fracture strength of incisal under 3 mm, there was significant difference between gold electroformed crown($688.29{\pm}14.88N$) and porcelain fused to gold crown($1931.81{\pm}29.64N$) (p<0.05). 3. Mode of fracture When compared of fracture mode, gold electroformed crown showed mode of fracture and fracture line reaching coping region and porcelain fused to gold crown showed only in porcelain region.
1. There was significant relationship between personality traits and coping behavior. (1) Type A Group used more problem-focused and emotion-focused coping style than Type B Group (2) Non-sociable group used more emotion-focused coping style especially 'escape-avoidance' behavior than sociable group (3) Emotionally unstable group used more emotion-focused coping style especially 'distancing' and 'escape-avoidance behavior than stable group. 2. There was no significant relationship between personality traits and stress coping effect except emotional stability. 3. There was same inter-correlations among personality, coping style, and coping effect, (1) Type A was significantly correlated with sociability but not with emotional stability. (2) Problem-focused coping style was positively correlated with emotion-focused coping style. (3) Coping effect was not significantly correlated with coping style and personality traits accept emotional stability. 4. There was significant relationship between cognitive appraisal and coping style. (1) When they appraised the event 'could change or did something about it,' that used more problem-focused coping style than appraised 'had to accept.' (2) When they appraised the event ' could control before it occures.' they used more problem-focused and emotion-focused coping style than appraised it 'could not control'. (3) When they appraised the event 'had to gold back.' they used more problem-focused and emotion-focused coping style than appraised it 'had not to hold back.' (4) When they appraised the event 'happened by me.' they used more problem-focused coping style than appraised it 'happened by others.' (5) When they appraised the event 'needed to know more, 'they did not significantly use more coping behavior than appraised it 'needed not to know more.' 5. There was no significant difference except two cases in cognitive appraisal to the problem according to the personality. The two cases were as follows: (1) Sociability group appraised the event 'had to accept.' while non-sociability group appraised it 'could change or did some thing about.' (2) Emotionally stable group appraised the event 'happened by others.' while emotionally unstable group appraised it "happened by me".
Statement of problem. The effect of gold electroforming on gold alloy was not studied. Purpose. This in vitro study investigate the effect of gold electroforming on gold-silver-palladium alloy. Material and methods. Three pieces of gold strips had undergone the electroforming procedures on one side and then half of the side again electroformed. The set mode for this study was program 1 ($200{\mu}m$). And the processing time was 15min (1/20 time to form $200{\mu}m$ coping). The confocal laser scanning microscope (PASCAL 5, Carl Zeiss, Bernried, Germany) was used to measure the thickness of the pure gold layer electroformed on the gold strips. Half of the gold strip was coated two times with electroformed gold, and the other half one time. The data from the cone focal laser system was processed to get the vertical profile of the strips and the difference of the vertical height between the double coated and single coated layer was regarded as the thickness of the gold coating. The layer thickness value to built 3D image of the cone-focal laser was set $0.5{\mu}m$. Next to the measurement of the thickness of the coating, the Vicker's hardness test was done. It was performed on the double coated surface, single coated surface and non-coated surface (back side) three times each. Results. The mean thickness value gained from gold electroforming technique was measured to be $22{\mu}m$ for sample 1, $23{\mu}m$ for sample 2, $21{\mu}m$ for sample 3. In the same condition of time, power and the amount of electrolyte, the data showed no difference between samples. According to the results of variance analysis, the differences among the variations in number of coating were statistically insignificant (p>0.05), meaning that the two times of gold electroforming coating did not change the hardness of gold-silver-palladium alloy. Conclusion. The test of thickness of gold coating proved the coherency of the gold electroforming procedure, in other words, when the power, the exposed surface area, processing time and the amount of electrolytes were set same, the same thickness of gold would be coated on. The hardness test showed that the electroformed gold coating did not change the hardness of the gold-silver-palladium alloy when it is coated not more than $45{\mu}m$.
Journal of Dental Rehabilitation and Applied Science
/
v.24
no.2
/
pp.193-201
/
2008
In edentulous mandible, implant supported overdenture was considered as a first treatment option. In case of a implant supported telescopic overdenture, sufficient inter-arch space needs for arrangement of artificial teeth and attachment. Passive fit of the implant prosthesis is important factor for preventing mechanical failure. Gold Electroforming System is particularly useful to achieve a passive fit of telescopic attachment and results in precision marginal fit and the small thickness of the coping provides optimal space for narrow inter-arch space. This article presents that application of Gold Electroforming System can provide excellent esthetics and function on four-implant supported telescopic overdenture.
Han Eu-Taek;Kim Yung-Soo;Kim Chang-Whe;Yang Jae-Ho
The Journal of Korean Academy of Prosthodontics
/
v.39
no.1
/
pp.1-13
/
2001
An absolutely passive fit at the interface with the superstructure and the abutment cylinders is need for implant longevity. In this study, a method of cast framework correction using spark erosion technology was evaluated. Electric discharge machining(EDM) is a process that uses electrical discharges, or sparks, to machine metal, The surface being machined is bombared with high-intensity electrical energy pulses that gradually melt away the stock until the desired configuration is obtained. Master model was fabricated by using metal block impression analogue, which fired 5 Branemark squared impression coping in an arc shaped metal block. Then framework using 4mm standard gold cylinder and type IV gold alloy was fabricated. In order to measure the fit of the framework we used both contact and noncontact coordinate measurement machine and data was processed by computer program. After superimposition of gold framework and master model numeric image data the distances between gold cylinder bearing surfaces and abutment replica bearing surfaces, and the angle deviations between gold cylinder and abutment replica centroid points were calculated. The results were as follows 1 The total mean distance (p<0.01) and standard deviation (p<0.001) between the gold cylinders and abutment bearing surfaces were significantly decreased after EDM 2. The total mean of maximum distances was significantly decreased after EDM (p<0.05). 3. After EDM, the mean angle deviation between centroid points was decreased.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.