• Title/Summary/Keyword: Goal distributions

Search Result 72, Processing Time 0.026 seconds

IV ECM Threshold Cointegration Tests and Nonlinear Monetary Policy in Korea (분계점 공적분 검정법을 사용한 한국의 비선형 테일러 통화정책 검증)

  • Enders, Walter;Lee, Junsoo;Strazicich, Mark C.
    • KDI Journal of Economic Policy
    • /
    • v.29 no.2
    • /
    • pp.135-157
    • /
    • 2007
  • The goal of this paper is to examine the validity of nonlinear Taylor rules in Korea. To perform our tests, we utilize new IV ECM threshold cointegration tests that are invariant to nuisance parameters. The new tests have a standard chi-square distribution and the same critical values can be used throughout. This is in contrast to OLS ECM threshold cointegration tests, which depend on nuisance parameters and have nonstandard distributions. After finding significant support for nonlinear cointegration, we find that the Bank of Korea raises the call rate of interest only when inflation is above a threshold rate. We additionally find that the Bank of Korea increases the call rate of interest to possibly counter domestic currency deprecation only when the rate of currency deprecation exceeds a threshold.

  • PDF

Monthly Variation of n-alkanes concentration in PM2.5 of the Anmyeon Island (안면도 대기 중 PM2.5 내 n-alkanes의 월별 농도 분포 특성)

  • Kim, Ki Ae;Lee, Jong Sik;Kim, Eun Sil;Jung, Chang Hoon;Kim, Yong Pyo;Lee, Ji Yi
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.166-176
    • /
    • 2018
  • The n-alkanes which are stable compounds in the atmosphere are emitted by anthropogenic sources and biological sources. The goal of this study is to understand characteristics of n-alkane distributions in $PM_{2.5}$ of the Anmyeon Island which is one of background site in Korea. The concentration of n-alkanes in $PM_{2.5}$ was measured at Anmyeon Island for one year from June 2015 to May 2016. The average concentration of total n-alkanes (${\sum}$ n-alkanes) from C20 to C34 was $14.02{\pm}10.26ng\;m^{-3}$ and ranged from 1.77 to $47.65ng\;m^{-3}$. Various diagnostic parameters were used to identify the source. As a result, it is considered that Anmyeon Island had a large influence of biological sources during non-heating period, while the influence of anthropogenic emission during the heating period was significant. Principle Component Analysis (PCA) was performed and yielded three components that accounted for 93.6% of the total variance in n-alkanes. Factor 1, which accounted for 42.3% of the total variance, indicated anthropogenic source including fossil fuel and biomass combustion, while, Factor 3 was interpreted as the biological sources such as plant wax.

Estimation of Hardfacing Material and Thickness of STD61 Hot-Working Tool Steels Through Three-Dimensional Heat Transfer and Thermal Stress Analyses (3 차원 열전달/열응력 해석을 통한 STD61 열간 금형강의 하드페이싱 재료 및 두께 예측)

  • Park, Na-Ra;Ahn, Dong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.4
    • /
    • pp.427-436
    • /
    • 2014
  • The goal of this paper is to estimate proper hardfacing material and thickness of STD61 hot-working tool steel through three-dimensional heat transfer and thermal stress analyses. Stellite6, Stellite21 and 19-9DL superalloys are chosen as alternative hardfacing materials. The influence of hardfacing materials and thicknesses on temperature, thermal stress and thermal strain distributions of the hardfaced part are investigated using the results of the analyses. From the results of the investigation, it has been noted that a hardfacing material with a high conductivity and a thinner hardfaced layer are desired to create an effective hardfacing layer in terms of heat transfer characteristics. In addition, it has been revealed that the deviation of effective stress and principal strain in the vicinity of the joined region are minimized when the Stellite21 hardfaced layer with the thickness of 2 mm is created on the STD61. Based on the above results, a proper hardfacing material and thickness for STD61 tool steel have been estimated.

Radiotherapy Treatment Planning in Head and Neck Cancer by CT-Reconstruction (CT 재구성에 의한 두경부 종양의 방사선 치료 계획)

  • Ryu, Sam-Uel;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.141-148
    • /
    • 1987
  • The ultimate goal of radiotherapy is to result in complete local control of tumor while sparing the surrounding normal tissues as much as possible. Since the development of CT in 1970s, patient's anatomical normal tissues and the site and extent of infiltration of tumor were identified almost accurately. In addition, the isodose distribution of delivered radiation to target tumor was shown in each cross-section. In the treatment planning of head and neck cancers, CT-reconstruction provided almost 3-dimensinonal inter-relationship between tumor and normal tissues. The utilization of imaging system of the CT scanner made it possible to illustrate in superposition the patient structure image, the radiation beams, and the isodose distributions. Thus it was possible to deliver radiation enough to control the local disease, and to avoid unnecessary administration of radiation to normal tissue such as spinal cord. CT-reconstructed image in axial, sagittal, and coronal planes suggested 3-dimensional radiotherapy treatment planning be possible and practical instead of conventional 2-dimensional planning at coronal plane.

  • PDF

Analysis of the Uncertainty of Compressive Forces Acting on the Patella by Using Multi-Body Modeling and Muscle Mechanics (다물체 모델링과 근의 특성을 이용한 무릎뼈에 가해지는 압력의 불확실성 추정 연구)

  • NamGoong, Hong;Yoo, Hong-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.785-790
    • /
    • 2011
  • The goal of this study is to estimate the force acting on the knee joint in the human body by using the Hilltype muscle model based on a musculoskeletal model of the human lower extremity in the sagittal plane. For estimating the force applied, the human leg is modeled using multi-body modeling. This leg model comprises biarticular muscles acting on two joints of the upper and lower limbs, and the muscles include some of the major muscles such as the hamstring. In order to analyze the uncertainty of the applied forces acting on the knee joint, statistical distributions of human body, leg part, parameters are required and to obtain the parameter's statistical characteristic of the part sample survey method is employed. Finally, by using the sensitivity information of the parameters, the force acting on the knee joint can be estimated.

The Crack Behavior in the Planar Solid Oxide Fuel Cell under the Fabricating and Operating Temperature (제조 및 작동온도에서 평판형 고체연료전지에 발생한 균열 거동)

  • Park, Cheol Jun;Kwon, Oh Heon;Kang, Ji Woong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.34-41
    • /
    • 2014
  • The goal of this study is to investigate some crack behaviors which affect the crack propagation angle at the planar solid oxide fuel cell with cracks under the fabricating and operating temperature and analyze the stresses by 3 steps processing on the solid oxide fuel cell. Currently, there are lots of researches of the performance improvement for fuel cells, and also for the more powerful efficiency. However, the planar solid oxide fuel cell has demerits which the electrode materials have much brittle properties and the thermal condition during the operating process. It brings some problems which have lower reliability owing to the deformation and cracks from the thermal expansion differences between the electrolyte, cathode and anode electrodes. Especially the crack in the corner of the electrodes gives rise to the fracture and deterioration of the fuel cells. Thus it is important to evaluate the behavior of the cracks in the solid oxide fuel cell for the performance and safety operation. From the results, we showed the stress distributions from the cathode to the anode and the effects of the edge crack in the electrolyte and the slant crack in the anode. Futhermore the crack propagation angle was expected according to the crack length and slant angle and the variation of the stress intensity factors for the each fracture mode was shown.

Enhancing Robustness of Information Hiding Through Low-Density Parity-Check Codes

  • Yi, Yu;Lee, Moon-Ho;Kim, Ji-Hyun;Hwang, Gi-Yean
    • Journal of Broadcast Engineering
    • /
    • v.8 no.4
    • /
    • pp.437-451
    • /
    • 2003
  • With the rapid growth of internet technologies and wide availability of multimedia computing facilities, the enforcement of multimedia copyright protection becomes an important issue. Digital watermarking is viewed as an effective way to deter content users from illegal distributions. In recent years, digital watermarking has been intensively studied to achieve this goal. However, when the watermarked media is transmitted over the channels modeled as the additive white Gaussian noise (AWGN) channel, the watermark information is often interfered by the channel noise and produces a large number of errors. So many error-correcting codes have been applied in the digital watermarking system to protect the embedded message from the disturbance of the noise, such as BCH codes, Reef-Solomon (RS) codes and Turbo codes. Recently, low-density parity-check (LDPC) codes were demonstrated as good error correcting codes achieving near Shannon limit performance and outperforming turbo codes nth low decoding complexity. In this paper, in order to mitigate the channel conditions and improve the quality of watermark, we proposed the application of LDPC codes on implementing a fairly robust digital image watermarking system. The implemented watermarking system operates in the spectrum domain where a subset of the discrete wavelet transform (DWT) coefficients is modified by the watermark without using original image during watermark extraction. The quality of watermark is evaluated by taking Into account the trade-off between the chip-rate and the rate of LDPC codes. Many simulation results are presented in this paper, these results indicate that the quality of the watermark is improved greatly and the proposed system based on LDPC codes is very robust to attacks.

Comparison of 2D and 3D Brachytherapy Planning for Cervical Cancer (자궁경부암 근접방사선치료 시 2차원, 3차원 치료계획 비교평가)

  • Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.303-309
    • /
    • 2017
  • To evaluate the usefulness of 3-dimensional brachytherapy(BT) planning technique based on CT in cervical cancer. Patients with cervical cancer underwent 2-D BT treatment planning and then CT scan with HDR intracavitary applicators in place with same positions. Dose was prescribed to Point A with 5Gy per fraction on 2-D BT planning. For 3-D BT planning, and dose was prescribed to the High risk CTV for BT (HR CTV) with 5Gy. The 3-D BT planning goal was to cover at least 90% of the HR CTV with target 5Gy isodose surface while limiting the dose to $2cm^3$ of bladder to less than 7.5 Gy, and $2cm^3$ of rectum to less than 5Gy. In one patient of 10 patients, $D_{2cm3}$ of rectal dose was over 5Gy and 6patients at $D_{2cm3}$ of bladder dose on 2-D BT planning. There was a tendency to underestimate ICRU bladder dose than ICRU rectal dose. CT based 3-D BT planning for cervical cancer will enable evaluation of dose distributions for tumor and critical organs at risk. So, rectal and bladder morbidity as well as geographic miss will be reduced in case of the bulky disease or uterine malposition.

Thermal and Flow Analysis of a Driving Controller for Active Destruction Protections (능동 파괴 방호 구동제어기의 열 유동 해석)

  • Ryu, Bong-Jo;Oh, Bu-Jin;Kim, Youngshik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.235-242
    • /
    • 2017
  • A driving controller for active destruction protections can be applied to machinery, aerospace and military fields. In particular, this controller can be used to track and attack enemy flying objects through the active control. It is important to ensure reliability of the driving controller since its operation should be kept with precision to the target point. The temperature of the environment where the driving controller is used is about -32 C ~ 50 C (241~323 ). Heat generated in the driving controller should be maintained below a certain threshold (85 C (358 )) to ensure reliability; therefore, the study and analysis of the heat flow characteristics in the driving controller are required. In this research, commercial software Solid-Works Flow Simulation was used for the numerical simulation assuming a low Reynolds number turbulence model and an incompressible viscous flow. The goal of this paper is to design the driving controller safely by analyzing the characteristics of the heat flow inside of the controller composed of chips or boards. Our analysis shows temperature distributions for boards and chips below a certain threshold.

Monte Carlo Calculation on the Dose Modulation Using Dynamic Magnetic Fields for 10 MV X-rays (움직이는 자기장을 이용한 10 MV X-선의 선량변조에 관한 몬테칼로 계산)

  • Kim, Ki Hwan;Oh, Young Kee;Shin, Kyo Chul;Kim, Jhin Kee;Jeong, Dong Hyeok;Kim, Jeung Kee;Cho, Moon June;Kim, Sun Young
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.221-225
    • /
    • 2007
  • Monte Carlo calculations were performed to demonstrate the dose modulation with dynamic magnetic fields in phantom. The goal of this study is to obtain the uniform dose distributions at a depth region as a target on the central axis of photon beam under moving transverse magnetic field. We have calculated the depth dose curves for two cases of moving magnetic field along a depth line, constant speed and optimal speed. We introduced step-by-step shift and time factor of the position of the electromagnet as an approximations of continuous moving. The optimal time factors as a function of magnetic field position were calculated by least square methods using depth dose data for static magnetic field. We have verified that the flat depth dose is produced by varying the speed of magnetic field as a function of position as a results of Monte Carlo calculations. For 3 T magnetic field, the dose enhancement was 10.1% in comparison to without magnetic field at the center of the target.

  • PDF