• Title/Summary/Keyword: Glucose sensor

Search Result 145, Processing Time 0.024 seconds

A Study on the Detection Characteristics in Glucose and Fabrication of Bi-Enzyme Electrode using Electrochemical Method (전기화학적 방법을 이용한 다중 효소 전극 제작 및 글루코스 검출 특성에 관한 연구)

  • Han, Kyoung Ho;Shin, In Seong;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.23 no.3
    • /
    • pp.66-72
    • /
    • 2020
  • In this study, the development of biosensors capable of bi-enzyme reactions by including Horseradish peroxidase and glucose oxidase was carried out for detection of glucose. The sensors were manufactured using electro deposition method to reduce production time, and screen printed electrodes (SPE) were used to produce economical sensors. To check the bienzyme effect, the sensor was compared and analyzed with single enzyme biosensor. The characteristics of the sensor were evaluated using scanning electron microscopy(SEM), cyclic voltammetry(CV), electrochemical impedance spectroscopy(EIS), chronoamperometry(CA), and flow injection analysis(FIA). Analysis results from SEM, CV and EIS confirmed that the enzymes are well fixed to the electrode surface. In addition, it was confirmed that bi-enzyme biosensors manufactured from the CA method improved signal performance by 200% compared to single enzyme biosensors. From this results, we were able to explain that HRP and GOD react catalyzed to each other. And the results of FIA showed that the intensity of each current signal was constant when the same concentration of glucose was injected four times. In addition, by analyzing the intensity of current signals for glucose concentrations, the biosensors manufactured in this study showed excellent trends in signal sensitivity, reproducibility and stability.

Fiber optic 산소센서를 이용한 생물공정의 모니터링

  • Lee, Jong-Il;Comte, Andreas;Hung, Lam Tuan;Kim, Jun-Hong
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.569-571
    • /
    • 2000
  • A fiber optic oxygen sensor has been employed to monitor the concentrations of dissolved oxygen in a bioreactor. The characteristics of fiber optic oxygen sensor was investigated, e.g. the dependency of agitation rate on the oxygen measurement and also the dependence of temperature on the performance of fiber optic oxygen sensor etc. We have also applied to monitor the concentrations of dissoved oxygen in real cultivation processes by using the fiber optic oxygens sensor. The fiber optic oxygen sensor can be applied to measure the concentration of metabolites by immobilizing some enzymes, e.g. glucose oxidase and also employed for the environmental technology.

  • PDF

An Improvement of Recovery Characteristics of ISFET Glucose Sensor by Employing Oxygen Electrolysis (산소분자의 전기분해법을 도입한 ISFET 포도당센서의 회복특성 개선)

  • Park, Keun-Yong;Choi, Sang-Bok;Lee, Young-Chul;Lee, Min-Ho;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.203-207
    • /
    • 2000
  • The sensitivity of ISFET glucose sensor is improved by employing amperometric actuation method. However, this method takes long time to recover the primary output voltage after measurement because of slow migration of the hydrogen ion between internal and external sensing membranes. Consequently, such a recovery-time delaying problem is one of obstacles to a practical use. In this paper, a new method is proposed to control the concentration of hydrogen ion in internal membrane, which applies a reduction potential to the working electrode for supplying hydroxide ion. Experimental results show that the recovery-time was reduced within 2 minute against decades minute of conventional method.

  • PDF

Electrochemical Characteristics of Pencil Graphite Electrode Through Surface Modification and its Application of Non-enzymatic Glucose Sensor (표면 개질된 샤프심 전극의 전기화학적 특성 고찰 및 비효소적 글루코스 센서 활용)

  • Min-Jung Song
    • Korean Chemical Engineering Research
    • /
    • v.62 no.2
    • /
    • pp.147-152
    • /
    • 2024
  • Most medical sensors are disposable products. In order to reduce inspection and diagnosis costs, it is more important to develop the inexpensive electrode materials. We fabricated the CuO NPs/PANI/E-PGE as an electrode material for disposable electrochemical sensors and applied it to a non-enzymatic glucose sensor. For surface activation of PGE, pretreatment was performed using chemical and electrochemical methods, respectively. Electrochemical properties according to the pretreatment method were analyzed through chronoamperometry (CA), cyclic voltammetry (CV) and electrochemical impedance (EIS). From these analytical results, the electrochemically pretreated PGE (E-PGE) was finally adopted. The non-enzymatic glucose sensor based on CuO NPs/PANI/E-PGE shows sensitivity of 239.18 mA/mM×cm2 (in a linear range of 0.282~2.112 mM) and 36.99 mA/mM×cm2 (3.75423~50 mM), detection limit of 17.6 μM and good selectivity. Based on the results of this study, it was confirmed that the modified PGE is a high-performance electrode material. Therefore, these electrodes can be applied to a variety of disposable sensors.

Evaluation of Pretreatment Effect and Non-enzymatic Glucose Sensing Performance of Carbon Fibers Tow Electrode (탄소섬유 토우의 전처리 효과와 비효소적 포도당 센싱 성능 평가)

  • Min-Jung Song
    • Korean Chemical Engineering Research
    • /
    • v.62 no.1
    • /
    • pp.13-18
    • /
    • 2024
  • To develop flexible electrode materials for wearable devices, we investigated the electrochemical characteristics of carbon fibers tow according to pretreatment. And an electrochemical non-enzymatic sensor was fabricated using glucose as a target. The carbon fibers tow was pretreated through desizing and activation processes, and activation was performed in two ways: chemical oxidation and electrochemical oxidation. Surface morphology of carbon fibers tow samples was observed by SEM and their electrochemical characteristics and sensing performance were investigated by cyclic voltammetry, electrochemical impedance spectroscopy and chronoamperometry. Carbon fibers tow samples showed improved electrochemical properties such as reduced Ret, ΔEp, and increased Ip through pretreatment. And similar electrochemical properties were obtained with both activation methods. We selected electrochemically activated carbon fibers tow as the final electrode material for application of electrochemical sensor. The non-enzymatic glucose sensor based on this electrode has an enhanced sensitivity of 0.744 A/mM (in a linear range of 0.09899~3.75423 mM) and 0.330 mA/mM (3.75423~50 mM), respectively. Through this study, the possibility of using carbon fibers tow was confirmed as an electrode material. It is expected to be used as basic research for development of high-performance flexible electrode materials.

Preparation and Characteristics of a Single-layer PVA Laminated CTA/PCL Membrane for Oxygen Biosensor Electrode (산소센서용 CTA/PCL 효소고정화막과 반투막을 단일화한 PVA적층막의 제조 및 특성)

  • Seo, Jong-Won;Kim, Tae-Jin;Jeong, Yong-Seob;Yoon, Jeong-Weon
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.247-252
    • /
    • 1999
  • The oxygen electrode of a biosensor needs enzyme immobilized membrane and a dialysis membrane to measure the oxygen concentration that remains after an enzyme reacts with its substrate. Accodingly, a single-layer PVA laminated CTA/PCL membrane was developed as an oxygen biosensor electrode. The enzymes were immobilized on a cellulose triacetate/polycarprolactone membrane using the 1,1'-carbonyl diimidazole(CDI) method, and then laminated with polyvinyl alcohol, aldehyde and acid. The alcohol oxidase and PVA laminated CTA/PCL membrane was tested with various concentration of enzyme substrates using a Yellow Springs Instrument(YSI) oxygen sensor. Under 5-10mmol substrates produced $0.37{\sim}0.83{\mu}A$(r=0.995) currents, and ater 8 weeks the glucose oxidase activity remained at about 56%, while the other activities remained very low. A SEM indicated a smooth surface and tightly attached PVA on the enzyme-immobilized CTA/PCL membranes.

  • PDF

Measurement of Glucose Concentration Using a Bio-Sensor$(\mu{FIAS)}$ (바이오 센서$(\mu{FIAS)}$를 이용한 Glucose 농도 측정)

  • ;Joseph Irudayaraj
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.02a
    • /
    • pp.209-214
    • /
    • 2003
  • 바이오 센서는 생물학적 인식 반응(Biological recognition reaction)이나 생물 촉매 공정(Bio-catalytic process)을 측정 가능한 전기적 신호로 변환시켜주는 적절한 변환기(Transducer)와 같은 생물학적 인식요소로 이루어진 감지 장치를 의미한다. 1962년 효소를 이용한 Glucose 전극봉의 개발이후 이 분야에 대한 수많은 연구와 기기의 개발이 진행되어왔다. 분석도구로써 바이오 센서는 효소, 항체, 수용체, 세포, 조직 등과 같은 생물학적 인식 요소들에 광범위하게 적용 가능하다는 장점이 있는 반면, 위에 열거한 생물학적 인식 요소들의 불안정성으로 인해 신뢰성이 유지되지 못하는 단점을 동시에 지니고 있다. (중략)

  • PDF

Microbial BOD Sensor Using Hansenula anomala

  • Ihn Gwon-Shik;Park Kyung-Ho;Pek Un-Hua;Sohn Moo-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.2
    • /
    • pp.145-148
    • /
    • 1992
  • A microbial sensor for BOD (Biochemical Oxygen Demand) measurement has been developed by immobilizing Hansenula anomala in a polyacrylamide gel. The optimum pH and temperature for BOD measurement using this sensor were pH 7.0 and $30^{\circ}C$, respectively. The response time was 30 min. A linear relationship was observed between the potential and the concentration below 44 ppm BOD. The potential was reproducible within ${\pm}9%$ of the relative error when a sample solution containing 20 mg/l of glucose and 20 mg/l of glutamic acid was employed. The effect of various compounds on BOD estimation was also examined. The potential output of the sensor was almost constant for 30 days. The relative error in BOD estimation was within ${\pm}10%$.

Implementation of Bio-Sensor with Coupled Plasmon-Waveguide Resonance Profile (결합된 플라즈몬-도파관 공진 구조로 구성된 바이오센서의 구현)

  • Kwang-Chun Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.1
    • /
    • pp.109-114
    • /
    • 2024
  • The bio-sensing properties of TE and TM guided modes in the coupled plasmon-waveguide resonance (PWR) configuration are investigated. The modal transmission-line theory (MTLT) is used for numerical analysis. The proposed PWR bio-sensor is composed of multi-layered configuration with N pairs of MgF2-Si3N4 layers to enhance the sensitivity of a conventional Ag-based surface plasmon resonance bio-sensor. The angular sensitivity of bio-sensor is numerically analyzed for a wide range of biological solutions (refractive index 1.33~1.37). Furthermore, the availability of sensor to detect cancer cells and blood plasma concentration is evaluated. Finally, the results indicate that the proposed bio-sensor is capable efficiently to detect various kinds of cancer cells and different glucose concentrations in urine.

A Strip Sensor Based on PbO2/Carbon Paste Electrode to Determine Sweetener Contents in Fruits (이산화납/탄소 반죽 전극을 이용한 과당 농도 측정 스트립센서)

  • Lee, Jae Seon;Cho, Joo Young;Heo, Min;Lim, Woo-Jin;Lee, Sang Eun;Nam, Hakhyun;Cha, Geun Sig;Shin, Jae Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.2
    • /
    • pp.130-137
    • /
    • 2014
  • A strip sensor based on $PbO_2$/carbon paste electrode was prepared by a screen-printing method, and employed to electrochemically determine the concentration of fruit sweeteners(i.e. glucose, sucrose, and fructose). The $PbO_2$/carbon paste electrode could monitor electrocatalytic oxidation of organic compounds such as carbohydrates, and measure the levels of natural sweeteners without enzyme. Severe interference from ascorbic acid was effectively reduced by modifying the electrode surface with a Nafion membrane. The response level of the Nafion/$PbO_2$/carbon paste electrode increased in the order of fructose, sucrose, and glucose, which corresponds to the order of sweetness perceived by humans.