• Title/Summary/Keyword: Glucose detection

Search Result 177, Processing Time 0.028 seconds

Recent Advances in Nanozyme Research for Disease Diagnostics (질병진단을 위한 나노자임 연구의 최근 동향)

  • Shin, Ho Yun;Yoon, Tae Young;Kim, Moon Il
    • KSBB Journal
    • /
    • v.30 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • Nanomaterial-based artificial enzymes (Nanozymes) have attracted recent attention because of their unique advantageous characteristics such as excellent robustness and stability, low-cost production by facile scale-up, and longterm preservation capability that are critically required as an alternative to natural enzymes. These nanozymes exhibit natural enzyme-like activity, and they have been applied to diverse kinds of detection methods for disease-associated biomolecules such as DNAs, proteins, cells, and small molecules including glucose. To highlight the progress in the field of disease diagnostics using nanozyme, this review discusses many nanozyme-based detection methods categorized by the types of target biomolecules. Finally, we address the current challenges and perspectives for the widespread utilization of nanozyme-based disease diagnostics.

Enhanced Performance of Immunoassays with Affinity-Purified Analyte-Enzyme Conjugates as Signal Generators

  • 백세환
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.5
    • /
    • pp.515-519
    • /
    • 1997
  • In a competitive enzyme immunoassay, the performance was tested with different analyte-enzyme conjugates (signal generators) in their binding constants to antibody. Analyte (progesterone)-enzyme (glucose oxidase; GO) conjugates were chemically synthesized and purified by using a gel column with an immobilized antibody to progesterone. In an elution range from the column, four peaks were detected by measuring total enzyme activities. Results from further analysis indicated that the first peak contained mainly unreacted GO while the next three peaks conjugated GO with progesterone. These three conjugate preparations were compared in dose-response curves along with the unpurified mixture. The purified conjugates showed higher detection capabilities than did the mixture. Especially, the preparation in the second peak next to the free GO peak improved the detection limit five times. This performance was comparable to that of a progesterone-horseradish peroxidase conjugate that has been identified to have one progesterone ligand.

Graphene and Carbon Quantum Dots-based Biosensors for Use with Biomaterials

  • Lee, Cheolho;Hong, Sungyeap
    • Journal of information and communication convergence engineering
    • /
    • v.17 no.1
    • /
    • pp.49-59
    • /
    • 2019
  • Biosensors, which are analysis devices used to convert biological reactions into electric signals, are made up of a receptor component and a signal transduction part. Graphene quantum dots (GQDs) and carbon quantum dots (CQDs) are new types of carbon nanoparticles that have drawn a significant amount of attention in nanoparticle research. The unique features exhibited by GQDs and CQDs are their excellent fluorescence, biocompatibility, and low cytotoxicity. As a result of these features, carbon nanomaterials have been extensively studied in bioengineering, including biosensing and bioimaging. It is extremely important to find biomaterials that participate in biological processes. Biomaterials have been studied in the development of fluorescence-based detection methods. This review provides an overview of recent advances and new trends in the area of biosensors based on GQDs and CQDs as biosensor platforms for the detection of biomaterials using fluorescence. The sensing methods are classified based on the types of biomaterials, including nucleic acids, vitamins, amino acids, and glucose.

Studies on the Mucilage of the Root of Abelmoschus manihot, MEDIC -[Part II] Detection of Sugars in the Mucilage- (황촉규근(黃蜀葵根) 점액(粘液)에 관(關)한 연구(硏究) -[제2보(第二報)] 점액내(粘液內) 당류(糖類)의 검색(檢索)-)

  • On, Doo-Heayn;Im, Zei-Bin;Sohn, Joo-Hwan
    • Applied Biological Chemistry
    • /
    • v.19 no.1
    • /
    • pp.41-50
    • /
    • 1976
  • When the root of Abelmoschus manihot, MEDIC is stored in the water, the mucilage is extracted. The mucilage has contained some of free reducing sugars. We have investigated the change of free reducing sugars by the Bertrand method and also free reducing sugars are detected by paper chromatography and thin layer chromatography. The mucilage is isolated from the root of Abelmoschus manihot, MEDIC and its chemical components are detected. The mucilage and hydrolyzed products are examined by paper chromatography, thin layer chromatography and tested carbohydrates under the usual way. The results are as follow: 1. The mucilage has contained five kinds of monosaccharides which are rhamnose, xylose, arabinose, glucose, galactose and other three kinds of uronic acids. 2. In the mucilage, glucose is the most changeable sugar and the next are arabinase and galactose. 3. Uronic acids, pylose and rhamnose are remained comparatively longer than glucose, galactose and arabinose in the mucilage. 4. The hydrolyzed products of mucilage consisted of rhamnose, xylose, arabinose, glucose, gelactose, ribose, some uronic acids and other unknown compounds. 5. The essence of mucilage isolated from the root of Abelmoschus manihot, MEDIC is complex saccharide, glucose and ribose are newly certified. 6. We can guess that the components of the mucilage are rhamnose, xylose, arabinose, glucose, ribose, uronic acids and other unknown compounds.

  • PDF

Imaging of Gastric Cancer Metabolism Using 18 F-FDG PET/CT

  • Yun, Mijin
    • Journal of Gastric Cancer
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Aerobic glycolysis has been the most important hypothesis in cancer metabolism. It seems to be related to increased bioenergetic and biosynthetic needs in rapidly proliferating cancer cells. To this end, F-18 fluorodeoxyglucose (FDG), a glucose analog, became widely popular for the detection of malignancies combined with positron emission tomography/computed tomography (PET/CT). Although the potential roles of FDG PET/CT in primary tumor detection are not fully established, it seems to have a limited sensitivity in detecting early gastric cancer and mainly signet ring or non-solid types of advanced gastric cancer. In evaluating lymph node metastases, the location of lymph nodes and the degree of FDG uptake in primary tumors appear to be important factors affecting the diagnostic accuracy of PET/CT. In spite of the limited sensitivity, the high specificity of PET/CT for lymph node metastases may play an important role in changing the extent of lymphadenectomy or reducing futile laparotomies. For peritoneal metastases, PET/CT seems to have a poorer sensitivity but a better specificity than CT. The roles of PET/CT in the evaluation of other distant metastases are yet to be known. Studies including primary tumors with low FDG uptake or peritoneal recurrence seem suffer from poorer diagnostic performance for the detection of recurrent gastric cancer. There are only a few reports using FDG PET/CT to predict response to neoadjuvant or adjuvant chemotherapy. A complete metabolic response seems to be predictive of more favorable prognosis.

Enzyme-Free Glucose Sensing with Polyaniline-Decorated Flexible CNT Fiber Electrode (Polyaniline을 이용한 CNT fiber 유연 전극 기반의 비효소적 글루코스 검출)

  • Song, Min-Jung
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.1-6
    • /
    • 2022
  • As the demand for wearable devices increases, many studies have been studied on the development of flexible electrode materials recently. In particular, the development of high-performance flexible electrode materials is very important for wearable sensors for healthcare because it is necessary to continuously monitor and accurately detect body information such as body temperature, heart rate, blood glucose, and oxygen concentration in real time. In this study, we fabricated the nonenzymatic glucose sensor based on polyaniline/carbon nanotube fiber (PANI/CNT fiber) electrode. PANI layer was synthesized on the flexible CNT fiber electrode through electrochemical polymerization process in order to improve the performance of a flexible CNT fiber based electrode material. Surface morphology of the PANI/CNT fiber electrode was observed by scanning electron microscopy. And its electrochemical characteristics were investigated by chronoamperometry, cyclic voltammetry, electrochemical impedance spectroscopy. Compared to bare CNT fiber electrode, this PANI/CNT fiber electrode exhibited small electron transfer resistance, low peak separation potential and large surface area, resulting in enhanced sensing properties for glucose such as wide linear range (0.024~0.39 and 1.56~50 mM), high sensitivity (52.91 and 2.24 ㎂/mM·cm2), low detection limit (2 μM) and good selectivity. Therefore, it is expected that it will be possible to develop high performance CNT fiber based flexible electrode materials using various nanomaterials.

Analysis of Marker Substances in Samul-tang by HPLC-MS/MS (HPLC-MS/MS에 의한 사물탕의 지표성분 분석)

  • Yu, Young-Beob;Kim, Mi-Jung;Huang, Dae-Sun;Ha, Hye-Kyeong;Ma, Jin-Yeul;Shin, Hyeun-Kyoo
    • The Korea Journal of Herbology
    • /
    • v.22 no.2
    • /
    • pp.97-102
    • /
    • 2007
  • Objectives : This study presents a high performance liquid chromatography - electrospray ionization-mass spectrometer (HPLC-MS/MS) methods for the quantitative and qualitative analysis of various active components in Samul-tang, which is composed of four crude herbs. Methods : HPLC-ESI-MS/MS for the determinations of paeoniflorin and 5-HMF (5-hydroxymethyl 2-furaldehyde) in the Samul-tang, the separation method was performed on an COSMOS1L 5C18-AR-Il (2.0 X 150 mm I.D.) column by gradient elution with 0.1% acetic acid and 5% CH3CN in water (A)-0.1% acetic acid and 5% H20 in CH3CN (B) as the mobile phase at a flow-rate of 300 ${\mu}L/min$ with detection at quadrupole mass spectrometer. The all marker substances were always detected as the base peaks in the positive ion mode. Results : The paeoniflorin of Paeoniae Radix in Samul-tang showed a strong base peak [M+H2O]+ in the positive detection mode to give the following as; paeoniflorin (498.109 [M+H2O]+, 479.8 [M]+, 301 [M-glucose]+, 179.3 [glucose]+). Based on the HPLC retnetion time and MS of standard compounds confirmed the identity of active compounds in Rehmanniae Radix Preparata as follows; 5-HMF (127.0[M+H]+, 109.3 [M-OH]+) in the positive ion mode. Conclusion : According to the above results, HPLC-ESI-MS method permits assignment of tentative structures such as paeoniflorin and 5-HMF in the Samul-tang.

  • PDF

Development of Urine Strip for Detection of Leukocytes in Urine using Peroxidase (과산화효소를 이용한 백혈구 측정용 뇨 검사지 제조에 관한 연구)

  • 송은영;이홍수;김희정;김종완;최인성;변시명;정태화
    • Biomedical Science Letters
    • /
    • v.2 no.2
    • /
    • pp.199-209
    • /
    • 1996
  • A new test strip to detect leukocytes using the myeloperoxidase in urine was developed. The reagent strip contains tetramethylbenzine, glucose and glucose oxidase. The detection limit was between 10 cells per 1$\mu$l urine(5 cells/hpf), showing greenish yellow color in the range of 10-25 cells/$\mu$l, green color in the range of 75-250 cells/$\mu$l, greenish blue color in the range of 500 cells/$\mu$l. The result can be obtained within two minute. The performance of the new method was evaluated by comparing the results of microscopic examination and other commercial products. Good correlations were shown between the values obtained by our urine strip and those by other commercial products with 172 urine samples. The results were proven that new methods were useful as primary screening reagents to detect leukocytes in urine.

  • PDF

Analysis of Metabolic Syndrome Risk Factors among the Menopausal Women in Her Fifties (50대 폐경 여성의 대사증후군 위험인자 분석)

  • Shim, Hye-Sun;Kim, Hee-Seung;Kim, Joo-Hyun
    • Journal of Korean Biological Nursing Science
    • /
    • v.12 no.1
    • /
    • pp.58-62
    • /
    • 2010
  • Purpose: The purpose of this study was to assess the difference of metabolic syndrome (MS) risk factors according to the MS diagnosis in the age of fifties women. Methods: Forty-two subjects (non metabolic syndrome 30, metabolic syndrome 12) were recruited from the health promotion center of a tertiary care hospital in an urban city. MS was defined by third report of the national cholesterol education program (NCEP) expert panel on detection, evaluation, and treatment of high blood cholesterol in adults (Adult Treatment Panel III) (ATP III), and abdominal obesity was determined by Asia-Pacific criteria in waist circumference. Results: The prevalence of MS by definition of NCEP-ATP III and Asia-Pacific criteria in waist circumference was 28.6% in the age of fifties women. The educational level and the median HDL-cholesterol were significantly lower in the MS patient group than in the Non-MS group. The median of weight, triglyceride, and fasting glucose were significantly higher in the MS patient group than in the Non-MS group. Conclusion: These results indicate that the nursing care should be focused on weight, triglyceride, HDL-cholesterol, and fasting glucose of the MS patients in the fifties women.

Current Developments of Biomedical Mobile Devices for Ubiquitous Healthcare (u-Healthcare를 위한 바이오 단말기의 개발 현황)

  • Lee, Tae-Soo;Hong, Joo-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.3
    • /
    • pp.185-190
    • /
    • 2009
  • Biomedical mobile devices for ubiquitous healthcare consist of biomedical sensors and communication terminal. They have two types of configuration. One is the sensor-network type device using wired or wireless communication with intelligent sensors to acquire biomedical data. The other is the sensor embedded type device, where the data can be acquired directly by itself. There are many examples of sensor network type, such as, fall detection sensor, blood glucose sensor, and ECG sensors networked with commercial PDA phone and commercial phone terminal for ubiquitous healthcare. On the other hand, sensor embedded type mounts blood glucose sensor, accelerometer, and etc. on commercial phone. However, to enable true ubiquitous healthcare, motion sensing is essential, because users go around anywhere and their signals should be measured and monitored, when they are affected by the motion. Therefore, in this paper, two biomedical mobile devices with motion monitoring function were addressed. One is sensor-network type with motion monitoring function, which uses Zigbee communication to measure the ECG, PPG and acceleration. The other is sensor-embedded type with motion monitoring function, which also can measure the data and uses the built-in cellular phone network modem for remote connection. These devices are expected to be useful for ubiquitous healthcare in coming aged society in Korea.