• Title/Summary/Keyword: Glow discharge spectrometry

Search Result 33, Processing Time 0.019 seconds

Analysis of Cast Iron by Glow Discharge Emission Spectrometry (글로우 방전/방출분광분석법에 의한 주철시료의 분석)

  • Cho, K.H.;Woo, J.C.;Han, M.S.
    • Analytical Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.297-305
    • /
    • 1993
  • Generally, it is difficult to analyze cast iron samples with spark discharge emission spectrometry since the content of carbon in these samples is high as a few percent. The cast iron samples were analyzed with the developed glow discharge emission spectrometer composed of glow discharge emission source and polychromator. The discharge condition of glow discharge lamp(GDL) has been optimized by variation of Ar gas pressure, discharge voltage and discharge time. Under the optimum conditions obtained in this work, relationships between the measured emission intensities and concentration of two types of cast iron standard samples(BAS, LECO) were investigated. Most of elements(Mn, Si, P, S etc.) showed the good linearity in one calibration curve. And the carbon showed slightly the systematic difference according to the type of standard samples.

  • PDF

Quantitative Analysis of Zn-Fe Electroplated Steel Sheet by Glow Discharge Spectrometry (Glow Discharge 방출분광법에 의한 Zn-Fe 전기도금강판의 정량분석)

  • So, Jai-Chun;Chung, Sung-Wook;Lee, Do-Hyung
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.73-77
    • /
    • 1992
  • The quantitative analysis experiment of Zn-Fe electroplated steel was carried out by means of glow discharge spectrometry. The experimental results of chemical composition and coating weight of the Zn-Fe layer were compared with those obtained by the wet chemical analysis method. It has been found that those results obtained by two different methods agreed well with each other.

  • PDF

A Study on Air Emission Spectra Observed by Using Electrothermal-Hollow Cathode Glow Discharge Spectrometry (Et-HCGDS) (Electrothermal-Hollow Cathode Glow Discharge Spectrometry(Et-HCGDS)를 이용하여 살펴본 Air Emission에 관한 연구)

  • Lee, Sang Chun;Shin, Jung-Sook;Kang, Mi-Ra
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.5
    • /
    • pp.399-407
    • /
    • 1995
  • Electrothermal-Hollow Cathode Glow Discharge Spectrometry (Et-HCGDS) has been constructed in our laboratory for in-situ monitoring of traceble amounts of rare earth elements and actinides. Et-HCGDS is the portable glow discharge system that can perform the trace analysis of elements. The main structural design of Et-HCGDS was based upon the electrothermal heating and glow discharge techniques. More details on Et-HCGDS are available elsewhere. In this study, air was used as a flow gas for the glow discharge system. As a result, the emission spectra of air were collected and the assignment of air emission lines was performed with helps of pure nitrogen and oxygen emission spectra and previously published results. We found that the emission lines of air plasma were mainly due to nitrogen molecules. This paper includes the complete assignments of the air emission lines observed by using Et-HCGDS. Also, this study will be an useful reference for spectrochemical anaysis including air analysis.

  • PDF

Development of Schiff Base Column and Glow Discharge Detector for HPLC : Preliminary Study I (HPLC용 Schiff Base 컬럼과 Glow Discharge 검출기의 개발에 관한 기초연구 I)

  • Kang, Mi-Ra;Kim, Eun-Soo;Shin, Jung-Sook;Park, Hyun-Kook;Yang, Jung-Sung;Lee, Sang C.
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.265-272
    • /
    • 1995
  • Schiff base ligand columns and glow discharge detector have been developed for the trace analysis of metal ions desolved in water. Various types of hydrazide Schiff base ligands have been used and, additionally, they were examined as a filling material of a HPLC column. The hydrazide Schiff base ligands used were N, N'-oxalybis(salicylaldehydrazone) (OBSH), N, N'-malonylbis(salicylaldehydrazone) (MBSH), and N, N'-succinylbis(salicylaldehydrazone) (SBSH). A mixture of Schiff base ligand and poly(styrene divinylbenzene) was examined and it showed a smooth flow of solution. The OBSH-polymer column demonstrated different effluent factors for different metal ions. Metal ions in eluates were detected by Hollow Cathode Glow Discharge-Atomic Emission Spectrometry(HCGD-AES). HCGD-AES showed good sensitivity and selectivity. This is only the preliminary results of new OBSH-polymer column and glow discharge detector.

  • PDF

Development of Analytical Techniques for Human Serum and Urine by Using Glow Discharge (글로우 방전을 이용한 혈청과 뇨의 분석기술 개발)

  • Lee, Sang Chun;Choi, Kyung-Soo;Son, Eun-Ho;Sim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.167-173
    • /
    • 1998
  • An electrothermal vaporization-hollow cathode glow discharge-atomic emission spectrometer(ETV-HCGD-AES) has been developed for detecting heavy metals in human serum and urine samples. Fisrt of all, we designed a glow discharge cell for atomic emission spectrometry and its analytical performance was studied with the standard reference materials(SRMs) purchased from the NIST. Practically, the ETV-HCGD-AES demonstrated better instrumental sensitivity and selectivity for detecting Hg and Pb in the SRMs, serum and urine, than ICP-OES since the ETV-HCGD-AES was not required the complicate sample digestion procedure, which improved sample transportation efficiency.

  • PDF

Characterization and Emission/Absorption Study of a Grimm-type Glow discharge source in the application of high frequency Glow Discharge (고주파 글로우 방전을 이용한 GRIMM형 방전원의 특성 및 방출/흡광분석법 연구)

  • Suh, Jung-Gee;Woo, Jin-Chun
    • Analytical Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.155-164
    • /
    • 1994
  • A conventional Grimm-type glow discharge source was constructed and applied to radio-frequency(13.56MHz) discharge for metal and ceramic analysis. We investigated the emission spectrum for aluminium and aluminium oxide and the influence of discharge operating paramaters including argon pressure, rf-power and DC-bias voltages at the sample-side electrode. Scanning Electron Microscope(SEM) also was used to investigate the effect of rf-sputtering on the microstructure formation of the aluminium oxide. Linear analytical calibration curves were constructed for Manganese and zinc element in samples of low alloy steel(BAS 401-405) and brass(NIST 1108-1117).

  • PDF

Comparison Study of Sensitivity Factors of Elements in Glow Discharge- & Inductively Coupled Plasma- Mass Spectrometry

  • Kim, Young-Sang;Plotnikov, M.;Hoffmann, Volker
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.12
    • /
    • pp.1991-1995
    • /
    • 2005
  • Sensitivity factors of elements by a glow discharge mass spectrometry (GD-MS) were intensively investigated and compared with a laser ablation inductively coupled plasma-mass spectrometry (ICP-MS). In case of copper matrix, the sensitivity factor by GD-MS generally decreases with the increase of the mass number of element. The details are a little different between each data measured by Faraday and multiplier detectors. The factor by a multiplier detector drastically decreases with the mass increase in the region of low mass as in Faraday detector’s case, but slowly in the high mass region. On the contrast, the sensitivity factor of solution standard by a conventional ICP-MS slowly increases with the increase of elemental mass number even though there are some exceptions such as gold and also the sensitivity factor by a laser ablation ICP MS generally increases with mass number of element in the specimen of glass type. In case of steel matrix, any definite trends could not be shown in the relationship between the GD-MS’s sensitivity factor and elemental mass.

Analysis of multi-layered Surface with Glow Discharge-Mass Spectrometry (글로우방전 질량분석법을 이용한 다층박막의 표면 분석)

  • Pak, Yong-Nam;Lee, Gae-Ho;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.357-361
    • /
    • 1997
  • A Griemm type Glow Discharge cell is attached to a commercial quadrapole based ICP-MS and used for the analysis of surface analysis. By employing 2.0mm diameter, mode and proper experimental conditions, several layers of few ${\mu}m$ thickness are analysed within 30 minutes. Multi-layers of Cu-Ni, Fe-Ni are analyzed with the resolution of 10nm by GDMS. Proper experimental conditions make a flat bottom crater shape and good resolution for multi-layer depth profile study.

  • PDF

Direct Anlysis of Impurities in Solides with Glow Discharge Mass Spectrometry

  • Ki Beom Lee;Dae Won Moon;Kwang Woo Lee
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.6
    • /
    • pp.524-529
    • /
    • 1989
  • A glow discharge mass spectrometric(GDMS) analytical method was developed for direct analysis of impurities in solids. Ions extracted from a glow discharge ion source with a sample as a cathode were analyzed by a quadrupole mass filter. Ion extractions were carried out through differentially-pumped orifices biased to positive and negative potentials. Operating parameters of the glow discharge source such as discharge current, orifice-to-cathode distance, energy analyzer setting and bias voltages have been optimized. The developed GDMS was applied to the analysis of KSS copper-base alloy standards certified by Korea Standards Research Institute(KSRI). In the analysis, the reproducibility and the detection limits were estimated to be about 2.5% RSD, and in the low ppm range, respectively.