• Title/Summary/Keyword: Globe temperature

Search Result 119, Processing Time 0.03 seconds

Comparison of Several Heat Stress Indices for the 2016 Heat Wave in Daegu (대구의 2016년 폭염시기 열 스트레스 지표의 비교)

  • Kim, Ji-Hye;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.26 no.12
    • /
    • pp.1399-1405
    • /
    • 2017
  • We compared the spatial distribution of several heat stress indices (the Wet-Bulb Globe Temperature(WBGT) index, Environmental Stress Index (ESI), and Modified Discomfort Index(MDI)) for the heat wave of June 6~August 26, 2016, in Daegu. We calculated the heat stress indices using data from the high density urban climate observation network in Daegu. The observation system was established in February. 2013. We used data from a total of 38 air temperature observation points (23 thermometers and 18 automatic weather stations). The values of the heat stress indices indicated that the danger level was very high from 0900-2000h in downtown Daegu. The daily maximum value of the WBGT was greater than or equal to $35^{\circ}C$. The differences in the heat stress indices from downtown and rural areas were higher in the daytime than at nighttime. The maximum difference was about 4 before and after 1400h, and the time variations of the heat stress indices corresponded well. Thus, we were able to confirm that the ESI and MDI can be substituted with the WBGT index.

A Study on Causes and Measures Against Occurrence of Circulating Current in catenary (전차선로 순환전류 발생원인과 대책에 관한 연구)

  • Han, Hag-Su;Min, Kyung-Yun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.816-823
    • /
    • 2007
  • Electric car tract plays the role of supply high electric power to the electric car from the substation by using Pantograph of the electric car. It is always exposed to the external atmosphere, which results in quite substantial fluctuations in current and voltage during operation of electric car. This generates possibility of occurrence of accident at all times. Since range of wiring metallic globe installed on the catenary cannot achieve complete electrical contact, accidents are occurring due to circulating current caused by arc caused by incomplete contact due to occurrence of hairline fracture of Pantograph due to pressure or vibration of wiring. Furthermore, rapid increase in the operational current due to increase in the operational frequency of the electric car is causing erosion and short circuit of the metallic globe at the contact points. This study on arc is generated as current transmitted out of the substation courses through power line or wiring metallic globe other than the main circuit as the current is being collected at the electric car through feeder and feeder divergence device. Accordingly, since heat generated by the arc becomes the cause for generation of circulating current due to melting of metal or softening of metal due to increase in temperature accompanying increase in contact resistance, this research shall describe causes and measures against occurrence of circulation current.

  • PDF

Evaluation of the Disk-to-Body Friction Load by the Side Flow in Motor-Operated Globe Valves (모터구동 글로브밸브의 Side Flow에 의한 디스크-몸체 마찰부하 평가)

  • Jeoung, Rae-Hyuck;Park, Sung-Keun;Lee, Do-Hwan;Song, Seok-Yoon;Kang, Shin-Cheul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.549-554
    • /
    • 2003
  • EPRI PPM (Performance Prediction Methodology), a method used for the prediction of required thrust of valves, can not be applied to unbalanced-disk globe valves operated in the fluid when the fluid temperature is above $150^{\circ}F$ because the thrust increase caused by the friction between the valve disk and body is not considered in the PPM. In order to apply PPM to the valves, EPRI suggested new friction prediction method to be added in the code. This paper analyzes the applicability of the prediction method comparing the disk-to-body friction load predicted from the method with the measured friction load from the field tests. The maximum values from the prediction method and those obtained from the test were 268lbs and about 1500lbs, respectively. It is included that the prediction method should be improved for the realistic prediction of disk-to-body friction load.

  • PDF

Effect of Vernalizing Temperature on Growth and Yield of Globe Artichoke (아티초크 저온처리가 생육 및 수량에 미치는 영향)

  • Kim, Chun Hwan;Seong, Ki Cheol;Ahn, Yul Kyun;Kim, Seong Cheol;Song, Eun Young;Lim, Chan Kyu;Son, Daniel
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.209-213
    • /
    • 2013
  • This study was conducted to produce heads of artichoke in July in Korea. The artichoke was planted in the Autumn and it could be reaped heads of artichokes in late of May in Korea. It can inform us that the artichoke need under some low temperature during the Winter to open flowers. In order to harvest heads of artichoke in the Summer two kinds of cultivar 'Green Globe' and 'Imperial Star' those were grown for 4 weeks in green house of $17^{\circ}C$ which were treated at 3, 6, 9 and $12^{\circ}C$ chamber for 4 weeks and then planted the 8th April. Plant distance was $150{\times}50$ cm. After 3 months most of artichoke of 'Imperial Star (IS)' made heads. Especially, the artichokes 'IS' were treated at $6^{\circ}C$ made heads 63% of plants but those at $12^{\circ}C$ made heads 33% and the artichokes (no treatment at low temperature) grown in greenhouse at $17^{\circ}C$ for 8 weeks made heads 5% of plants. 'Green Globe (GG)' made heads 28% of plants at $9^{\circ}C$ and 10% at $12^{\circ}C$, and 'GG' grown in greenhouse at $17^{\circ}C$ for 8 weeks never had made any head. The weights of head were 97 g and 86 g in 'IS' and 'GG' respectively. The yield of heads were 215 and 108 kg/10a in 'IS' and 'GG' respectively.

Analysis of the Irradiated Solar Heat Effect on Indoor Thermal Environment of the Top Floor Units of Apartment Houses in the Summer - On Condition that All Openings of the Units are Opened - (공동주택의 하절기 자연환기 시 지붕면 일사수열이 최상층 실내온열환경에 미치는 영향 분석)

  • Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • In the summer, the irradiated solar heat gain through the roof has an effect on the thermal environment of the top floor units of apartment houses. This paper investigated the differences of the indoor air temperature, globe temperature and thermal comfort index between the top floor unit and the middle floor unit by measuring them at the sample units on the condition that all the openings of the units are opened. The purpose of this paper is to provide quantitative data about the irradiated solar heat gain during the summertime through the roof of an apartment house and these data to be the source to reevaluate the appropriate roof insulation efficiency. From this study, we obtained three brief results as follows. Indoor air temperature difference between the two sample units shifts a day. Indoor air temperature at the top floor unit is $0{\sim}1.8^{\circ}C$ higher than that of the middle floor unit from 12:00 p.m. to 12:00 a.m. and $0{\sim}2.8^{\circ}C$ lower from 12:00 a.m. to 12:00 p.m. The evaluation of the indoor thermal comfort index and the globe temperature shows similar results as the indoor air temperature measuring. Results of this experiment verified the actual existence of indoor air temperature difference between the top floor unit and the middle one and this difference comes from the heat storage of the roof.

Interannual Variation of the TOMS Total Ozone and Reflectivity over the Globe (전지구에 대한 TOMS 오존전량과 반사율의 경년 변화)

  • Yoo, Jung-Moon;Jeon, Won-Sun
    • Journal of the Korean earth science society
    • /
    • v.21 no.6
    • /
    • pp.703-718
    • /
    • 2000
  • In order to investigate interannual variation of total ozone and reflectivity over the globe, Nimbus-7/TOMS data were used on the monthly mean and its anomaly for the period of 1979-92. This study also examined MSU channel 4(Ch4; lower-stratosphere) brightness temperature data and two model reanalyses of NCEP and GEOS to compare the ozone variation with atmospheric thermal condition. In addition, the MSU channel 1(Ch1 ; lower-troposphere) brightness temperature was used to compare with the reflectivity. The ozone showed strong annual cycle with downward trend(-6.3${\pm}$0.6 DU/decade) over the globe, and more distinct response to volcanic eruption than El Ni${\tilde{n}$o. The relationship between total ozone and MSU Ch4 observation, and between the ozone and model reanalyses of lower stratosphere temperature showed positive correlation(0.2-0.7) during the period of 1980-92. Reflectivity increased interannually by 0.2${\pm}$0.06%/decade over the globe during the above period and reflected El Ni${\tilde{n}$o(1982-83, 1991-92) well. Its variability in annual cycle was remarkably smaller in tropics than in higher latitudes. This is inferred due to cloud suppression and tropical upwelling regions. Reflectivity correlated negatively(-0.9) to the Ch1 temperature over the globe, but positively(0.2) over tropical ocean. The positive value over the ocean results from the effect of microwave emissivity which increases the Ch1 temperature with enhanced hydrometeor activity. Significant correlations between total ozone and the Ch4 temperature, and between reflectivity and the Ch1 Suggest that the TOMS data may use valuably to better understand the feedback mechanism of climate change.

  • PDF

Development of Basking Neodymium Lamp Improving Reflector Globe and Rhenium Filament (레늄 필라멘트와 반사 글로브를 개선한 Basking Neodymium Lamp의 개발)

  • Eo, Ik-Soo;Yang, Hae-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.477-482
    • /
    • 2007
  • This paper examines and analyzes improvement of structure of bulb, increase of luminous efficiency through application of reflector globe through aluminum coating and development of 60[W] basking neodymium lamp through optimum insertion ratio of krypton gas and nitrogen gas. The results of this development shows that the life of the lamp was 7,200 hours, and the luminous flux was 620[1m]. This brings in superior color temperature and superior color rendering index, which allows us to use that lamp for agricultural or general purpose.

  • PDF

Optimization of Several Environmental Factors to Human Performance by Using Taguchi Method

  • Ismail, A.R.;Haniff, M.H.M.;Yusof, M.Y.M.;Rahman, M.N.A.;Ghani, J.A.
    • Industrial Engineering and Management Systems
    • /
    • v.9 no.2
    • /
    • pp.157-164
    • /
    • 2010
  • The objective of this study is to determine the dominance effects of environmental factors such as Illuminance, humidity and Wet Bulb Globe Temperature (WBGT) on the operators' productivity at Malaysian electronic industry. A case study was carried out at an electronic components assembly factory. The environmental factors examined were the Illuminance (lux), humidity and WBGT of the surrounding workstation area. Two sets of representative data including the illuminance, humidity and WBGT level and production rate were collected during the study. The production rate data were collected through observations and survey questionnaires while the illuminance level was measured using photometer model RS 180-7133, the humidity and WBGT level were measured by using Quest Temp apparatus and humidity. Taguchi Method was utilized to find the sequence of dominant factors that contributed to the productivity of operator at that specified production workstation. The study reveals that the dominant factor contributed to the productivity was WBGT, followed by illuminance and humidity.

Assessment of Semen Quality among Workers Exposed to Heat Stress: A Cross-Sectional Study in a Steel Industry

  • Hamerezaee, Masoud;Dehghan, Somayeh F.;Golbabaei, Farideh;Fathi, Asad;Barzegar, Loghman;Heidarnejad, Naseh
    • Safety and Health at Work
    • /
    • v.9 no.2
    • /
    • pp.232-235
    • /
    • 2018
  • Background: This study was conducted to investigate the heat stress and semen quality among male workers in a steel industry in Iran and investigate the relationship between heat stress indices and semen parameters. Methods: The study was conducted on workers exposed (n = 30) and unexposed (n = 14) to heat in a steel industry. After obtaining a brief biography of the selected employees, scrotal temperature, oral temperature, and environmental parameters were measured, and their semen samples were analyzed according to the procedure recommended by the World Health Organization. The heat stress indices, including wet-bulb globe temperature (WBGT) and predicted heat strain (PHS), in their workplace were calculated according to environmental parameters (ISO 7243:1989 and 7933:2004, respectively). Results: Time-weighted averages of WBGT and PHS ($35.76^{\circ}C$ and 491.56 $w/m^2{\frac{w}{m^2}}$, respectively) for the exposed group were higher than threshold limit values. The mean difference of environmental, physiological, and semen parameters (exception: pH of semen), and also WBGT and PHS indices were statistically significant (p < 0.05) between the two groups. Mean semen parameters were in the normozoospermic range. WBGT and PHS indices showed significantly "negative" correlation with physiological parameters (scrotal and oral temperature) and most semen parameters (semen volume, sperm morphology, sperm motility, sperm count; p < 0.05); moreover, the correlation of WBGT with these parameters was stronger than PHS. Conclusion: Semen parameters of the studied workers exposed to heat were in the borderline level of normozoospermic range, and their semen parameters were significantly lower than controls. For better assessment of occupational environment concerning physiological and semen parameters in steel industries, WBGT can be a more useful index.