• 제목/요약/키워드: Glassy carbon electrode (GCE)

검색결과 31건 처리시간 0.022초

Determination of Hg22+ Ions Using a Modified Glassy Carbon Electrode with 2,2':6':2''-Terpyridine

  • Kong, Young-Tae;Bae, Yun-Jung;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권2호
    • /
    • pp.346-350
    • /
    • 2002
  • A glassy carbon electrode (GCE) modified with 2,2':6':2”-terpyridine (2,2':6':2”-TPR) using a spin coating method was applied for the highly selective and sensitive analysis of a trace amount of $Hg_2^{2+}$ ions. Various experimental parameters, which influenced the response of the 2,2':6':2”-TPR modified electrode to $Hg_2^{2+}$ ions, were optimized. The linear sweep and differential pulse voltammograms for the 2,2':6':2”-TPR modified electrode deposited with Hg show a well-defined anodic peak at +0.65 V (vs. Ag|AgCl). After a 25 min preconcentration time in an $Hg_2^{2+}$ ion solution (0.1 M acetate buffer, pH 5.0), differential pulse voltammetry(DPV) with 2,2':6':2”-TPR modified electrode shows a linear response between $1.0\;{\times}\;10^{-6}M\;and\;2.0\;{\times}\;10^{-7}M$. The least-square treatment of these data produce an equation of I[${\mu}A$] = 0.031 + 0.005C with r = 0.980(n = 5). The detection limit of this electrode with linear sweep voltammetry and differential pulse anodic voltammetry were $2.0\;{\times}\;10^{-6}M\;and\;8.0\;{\times}\;10^{-8}M$, respectively. The presence of Pb, Fe, Cd, Ti, Ni, Co, Mg, Al, Mn, and Zn did not interfere in the analysis of the $Hg_2^{2+}$ ion. The 2,2':6':2”-TPR modified GCE has been successfully applied in determination trace amounts of Hg in a human urine sample.

Low Potential Amperometric Determination of Ascorbic Acid at a Single-Wall Carbon Nanotubes-Dihexadecyl Hydrogen Phosphate Composite Film Modified Electrode

  • Fei, Junjie;Wu, Kangbing;Yi, Lanhua;Li, Junan
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권9호
    • /
    • pp.1403-1409
    • /
    • 2005
  • A sensitive and selective electrochemical method was developed for the amperometric determination of ascorbic acid (AA) at a glassy carbon electrode (GCE) modified with single-wall carbon nanotubesdihexadecyl hydrogen phosphate (SWNT-DHP) composite film. The SWNT-DHP composite film modified GCE was characterized with SEM. The SWNT-DHP composite film modified GCE exhibited excellent electrocatalytic behaviors toward the oxidation of AA. Compared with the bare GCE, the oxidation current of AA increased greatly and the oxidation peak potential of AA shifted negatively to about -0.018 V (vs. SCE) at the SWNT-DHP composite film modified GCE. The experimental parameters, which influence the oxidation current of AA, were optimized. Under the optimal conditions, the amperometric measurements were performed at a applied potential of -0.015 V and a linear response of AA was obtained in the range from 4 ${\times}$ $10^{-7}$ to 1 ${\times}$ $10^{-4}$ mol $L^{-1}$ and with a limit of detect (LOD) of 1.5 ${\times}$ $10^{-7}$ mol $L^{-1}$. The interferences study showed that the SWNT-DHP composite film modified GCE exhibited good sensitivity and excellent selectivity in the presence of high concentration uric acid and dopamine. The proposed procedure was successfully applied to detect AA in human urine samples with satisfactory results.

The Modified Electrode by PEDOP with MWCNTs-Palladium Nanoparticles for the Determination of hydroquinone and Catechol

  • Naranchimeg, Orogzodmaa;Kim, Seul-Ki;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2771-2775
    • /
    • 2011
  • Poly-ethylenedioxypyrrole (PEDOP) coated thiolated multiwall carbon nanotubes palladium nanoparticles (MWCNTs-Pd) modified glassy carbon electrode (GCE) [PEDOP/MWCNTs-Pd/GCE] for the determination of hydroquinone (HQ) and it’s isomer catechol (CA) were synthesized and compared with bare GCE and thiolated multiwall carbon nanotubes (MWCNTs-SH/GCE). The modification could be made by simple processes on a GCE with MWCNTs-Pd covered by PEDOP in a 0.05 M tetrabutylammonium perchlorate (TBAP)/MeCN solution system. A well-defined peak potential evaluation of the oxidation of hydroquinone to quinone at 0.05 V (vs. Ag/AgCl), and electrochemical reduction back to hydroquinone were found by cyclic voltammetry (CV) in phosphate buffered saline (PBS) at pH 7.4. Peak current values increased linearly with increasing hydroquinone contents. The peak separation between the anodic and cathodic peaks at the PEDOP/MWCNTs-Pd/GCE was ${\Delta}Ep$ = 40 mV for HQ and ${\Delta}Ep$ = 70 mV for CA, resulting in a higher electron transfer rate. Moreover, good reproducibility, excellent storage stability, a wide linear range (0.1 ${\mu}M$ - 5 mM for HQ and 0.01 ${\mu}M$ - 6 mM for CA), and low detection limits ($2.9{\times}10^{-8}$ M for HQ and $2.6{\times}10^{-8}$ M for CA; S/N = 3) were determined using differential pulse voltammetry (DPV) and amperometric responses; this makes it a promising candidate as a sensor for determination of HQ and CA.

Nafion-DTPA-Glycerol이 수식된 유리탄소전극을 사용한 미분펄스 전압전류법에 의한 구리(II)이온의 측정 (Differential Pulse Voltammetric Determination of Copper(II) Using Glassy Carbon Electrodes Modified with Nafion-DTPA-Glycerol)

  • 박찬주;박은희;정근호
    • 한국환경보건학회지
    • /
    • 제30권2호
    • /
    • pp.115-122
    • /
    • 2004
  • A glassy carbon electrode(GCE) modified with nafion-DTPA (diethylene triamine-pentaacetic acid)-glycerol is used for the highly selective and sensitive determination of a trace amount of Cu(II). Various experimental parameters, which influenced the response of nafion-DTPA-glycerol modified electrode to Cu(II), are optimized. The Copper(II) is accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface is characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry(DPV). The electrochemical response is evaluated with respect to concentration of modifier, pH and preconcentration time, quiet time, copper(II) concentration, and other variables. A linear range is obtained in the concentration range 1.0${\times}$10$^{-8}$ M-1.0${\times}$10$^{-6}$ MCu(II) with 7 min preconcentration time. The detection limit(3s) is as low as 2.36${\times}$10$^{-8}$ M (1.50 ppb).

Electrochemical determination of chloramphenicol using a glassy carbon electrode modified with dendrite-like Fe3O4 nanoparticles

  • Giribabu, Krishnan;Jang, Sung-Chan;Haldorai, Yuvaraj;Rethinasabapathy, Muruganantham;Oh, Seo Yeong;Rengaraj, Arunkumar;Han, Young-Kyu;Cho, Wan-Seob;Roh, Changhyun;Huh, Yun Suk
    • Carbon letters
    • /
    • 제23권
    • /
    • pp.38-47
    • /
    • 2017
  • In this study, magnetite ($Fe_3O_4$) nanoparticles were electrochemically synthesized in an aqueous electrolyte at a given potential of -1.3 V for 180 s. Scanning electron microscopy revealed that dendrite-like $Fe_3O_4$ nanoparticles with a mean size of < 80 nm were electrodeposited on a glassy carbon electrode (GCE). The $Fe_3O_4/GCE$ was utilized for sensing chloramphenicol (CAP) by cyclic voltammetry and square wave voltammetry. A reduction peak of CAP at the $Fe_3O_4/GCE$ was observed at 0.62 V, whereas the uncoated GCE exhibited a very small response compared to that of the $Fe_3O_4/GCE$. The electrocatalytic ability of $Fe_3O_4$ was mainly attributed to the formation of Fe(VI) during the anodic scan, and its reduction to Fe(III) on the cathodic scan facilitated the sensing of CAP. The effects of pH and scan rate were measured to determine the optimum conditions at which the $Fe_3O_4/GCE$ exhibited the highest sensitivity with a lower detection limit. The reduction current for CAP was proportional to its concentration under optimized conditions in a range of $0.09-47{\mu}M$ with a correlation coefficient of 0.9919 and a limit of detection of $0.09{\mu}M$ (S/N=3). Moreover, the fabricated sensor exhibited anti-interference ability towards 4-nitrophenol, thiamphenicol, and 4-nitrobenzamide. The developed electrochemical sensor is a cost effective, reliable, and straightforward approach for the electrochemical determination of CAP in real time applications.

Ion-Imprinted Polymers Modified Sensor for Electrochemical Detection of Cu2+

  • An, Zhuolin;Liu, Weifeng;Liang, Qi;Yan, Guang;Qin, Lei;Chen, Lin;Wang, Meiling;Yang, Yongzhen;Liu, Xuguang
    • Nano
    • /
    • 제13권12호
    • /
    • pp.1850140.1-1850140.9
    • /
    • 2018
  • An electrochemical sensor ($Cu^{2+}$-IIPs/GCE) was developed for detection of $Cu^{2+}$ in water. $Cu^{2+}$-IIPs/GCE was prepared by dispersing $Cu^{2+}$ imprinted polymers ($Cu^{2+}$-IIPs) on a preprocessed glassy carbon electrode. $Cu^{2+}$-IIPs were synthesized on the surface of modified carbon spheres by ion imprinting technology. The electrochemical performance of $Cu^{2+}$-IIPs/GCE was evaluated by differential pulse voltammetry method. The response of $Cu^{2+}$-IIPs/GCE to $Cu^{2+}$ was linear in $1.0{\times}10^{-5}mol/L$ to $1.0{\times}10^{-3}mol/L$. The detection limit was $5.99{\times}10^{-6}mol/L$ (S=N = 3). The current response value of $Cu^{2+}$-IIPs/GCE was 2.14 times that of the nonimprinted electrode. These results suggest that $Cu^{2+}$-IIPs/GCE can detect the concentration of $Cu^{2+}$ in water, providing a new way for heavy metal ions adsorption and testing.

Amperometric Immunosensor for Myeloperoxidase in Human Serum Based on a Multi-wall Carbon Nanotubes-Ionic Liquid-Cerium Dioxide Film-modified Electrode

  • Lu, Lingsong;Liu, Bei;Liu, Chenggui;Xie, Guoming
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권11호
    • /
    • pp.3259-3264
    • /
    • 2010
  • A label-free amperometric immunosensor has been proposed for the detection of myeloperoxidase (MPO) in human serum. To fabricate such an immunosensor, a composite film consisting of N,N-dimethylformamide (DMF), multiwall carbon nanotubes (MWCNTs) and 1-ethyl-3-methyl imidazolium tetrafluoroborate ($EMIMBF_4$) suspension was initially formed on a glassy carbon electrode (GCE). Then cerium dioxide ($CeO_2$) dispersed by chitosan was coated on the GCE. After that, MPO antibodies (anti-MPO) were attached onto the nano$CeO_2$ surface. With a noncompetitive immunoassay format, the antibody-antigen complex formed between the immobilized anti-MPO and MPO in sample solution. The immunosensor was characterized by cyclic voltammetry, transmission electron microscopy (TEM) and scanning electron microscopy (SEM). The factors influencing the performance of the immunosensor were studied in detail. Under optimal conditions, the current change before and after the immunoreaction was proportional to MPO concentration in the range of 5 to $300\;ng\;mL^{-1}$ with a detection limit of $0.2\;ng\;mL^{-1}$.

Carbon Nanotube 전극과 효소반응기로 구성된 Amperometric Biosensor를 이용한 Biogenic Amines 검출 (Determination of Biogenic Amines using an Amperometric Biosensor with a Carbon Nanotube Electrode and Enzyme Reactor)

  • 김종원;전연희;김미라
    • 동아시아식생활학회지
    • /
    • 제20권5호
    • /
    • pp.735-742
    • /
    • 2010
  • 식품 중 잠재적 위험 물질로 작용할 수 있는 BAs의 신속 검출을 위하여 전기전도성이 우수하다고 알려진 MWCNTs의 개질, 작업 전극의 제작, 효소반응기 제작을 통해 바이오센서 시스템을 구성하고 hydrogen peroxide와 주요 BAs 물질에 대한 감응도를 측정하였다. MWCTS의 성질을 향상시키기 위해 아민기를 도입하였고, 이를 FT-IR 스펙트럼을 통해 확인하였다. 아민기를 도입한 MWCNTs를 GCE에 고착시키고 PB 막을 입힌 후 cyclic voltammetry 반응을 비교한 결과, PB/MWCNT-$NH_2$/GCE 전극이 GCE에 비해 산화 전류는 8배 이상, 전체 전류는 25배 이상의 높은 전류 흐름을 보였으며, 미세한 전류 흐름의 측정도 용이해진 것으로 나타났다. 또한, carrier buffer의 pH를 달리하여 제작된 전극의 감응 전류를 비교한 결과, pH 7.0에서 전류의 감응도가 가장 높게 측정되었다. 과산화수소를 주입하여 전극의 성능의 검증한 결과, $0.5 {\mu}M{\sim}100 {\mu}M$ 범위에서 선형관계를 보였으며, 검출 한계는 $0.5{\mu}M$로 측정되었다. Histamine 표준 용액 주입 시 $1{\mu}M{\sim}100{\mu}M$ 범위에서 선형 관계를 나타내었고, tyramine은 histamine에 비해 약 95%, 2-phenylethylamine과 tryptamine은 histamine에 비해 각각 75%, 70% 수준의 감응도를 이용하여 구성된 바이오센서 시스템이 낮은 검출 한계와 높은 수준의 반응 감도를 나타내어 BAs를 측정하는데 좋은 장치임이 확인되었다.

L-DOPA Synthesis Using Tyrosinase-immobilized on Electrode Surfaces

  • Rahman, Siti Fauziyah;Gobikhrisnan, Siramulu;Gozan, Misri;Jong, Gwi Taek;Park, Don-Hee
    • Korean Chemical Engineering Research
    • /
    • 제54권6호
    • /
    • pp.817-821
    • /
    • 2016
  • Levodopa or L-3,4-dihydroxyphenylalanine (L-DOPA) is the direct precursor of the neurotransmitter dopamine. L-DOPA is a well-known neuroprotective agent for the treatment of Parkinson's disease symptoms. L-DOPA was synthesized using the enzyme, tyrosinase, as a biocatalyst for the conversion of L-tyrosine to L-DOPA and an electrochemical method for reducing L-DOPAquinone, the product resulting from enzymatic synthesis, to L-DOPA. In this study, three electrode systems were used: A glassy carbon electrode (GCE) as working electrode, a platinum, and a Ag/AgCl electrode as auxiliary and reference electrodes, respectively. GCE has been modified using electropolymerization of pyrrole to facilitate the electron transfer process and immobilize tyrosinase. Optimum conditions for the electropolymerization modified electrode were a temperature of $30^{\circ}C$ and a pH of 7 producing L-DOPA concentration 0.315 mM. After 40 days, the relative activity of an enzyme for electropolymerization remained 38.6%, respectively.

Electrochemical Investigation of Tryptophan at a Poly(p-aminobenzene sulfonic acid) Film Modified Glassy Carbon Electrode

  • Ya, Yu;Luo, Dengbai;Zhan, Guoqin;Li, Chunya
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권5호
    • /
    • pp.928-932
    • /
    • 2008
  • A glassy carbon electrode (GCE) modified with poly(p-aminobenzene sulfonic acid) [Poly(p-ABSA)] film is fabricated by voltammetric technique in phosphate buffer solution (pH 8.0) containing $5.0\;{\times}\;10^{-3}\;mol\;L^{-1}$p- ABSA. Electrochemical behaviors of tryptophan at the Poly(p-ABSA) film electrode are investigated with voltammetry. The results indicate that the electrochemical response of tryptophan is improved significantly in the presence of poly(p-ABSA) film. Compared with the bare glassy carbon electrode, the Poly(p-ABSA) film electrode remarkably enhances the irreversible oxidation peak current of tryptophan. Some parameters such as voltammetric sweeping segments for the electrochemical polymerization, pH, accumulation potential and accumulation time are optimized. Under the optimal conditions, the oxidation peak current is proportional to tryptophan concentration in the range of $1.0\;{\times}\;10^{-7}$ to $1.0\;{\times}\;10^{-6}\;mol\;L^{-1}$, and $2.0\;{\times}\;10^{-6}$ to $1.0\;{\times}\;10^{-5}\;mol\;L^{-1}$ with a detection limit of $7.0\;{\times}\;10^{-8}\;mol\;L^{-1}$. The proposed procedure is successfully applied to the determination of tryptophan in a commercial amino acid oral solution.