• 제목/요약/키워드: Glass tube

검색결과 328건 처리시간 0.024초

Study on the Underwater Acoustic Properties of Polyurethane Elastomer

  • Shin, Hyun Dai;Ahn, Byung Hyun
    • Elastomers and Composites
    • /
    • 제52권4호
    • /
    • pp.326-331
    • /
    • 2017
  • Two kinds of polyurethane elastomers were prepared and their acoustical properties underwater investigated. Their dynamic mechanical properties were measured using a dynamic mechanical analyzer. The sound speed and echo reduction in the 1-50 kHz frequency range were calculated from the data obtained using the analyzer. The sound speed, transmission and attenuation cofficient in 300-800 kHz were measured in a water-filled tank. Impedance tube experiments were performed to determine the reflective coefficient and echo reduction in the 3-8 kHz range. The polyurethane elastomer containing a hollow glass sphere showed a lower reflective coefficient and a higher echo reduction than the polyurethane elastomer without a filler.

선박 유수분리기용 유분검출기의 개발 (Development of Oil Content Meter for Oily Water Separator in Ship)

  • 황정웅;정병건;김창화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.338-344
    • /
    • 2001
  • According to the MARPOL 73/78 of Convention, all ships should have oil filtering equipment and 15 ppm bilge which satisfy Requirements of MARPOL 73/78. This study is concerned with designing and manufacturing a prototype Oil content Meter(OCM) used in machinery area of ship. The prototype OCM is composed of two parts which are oil content sensing module and data processing unit. The oil content sensing module consists of infra-red light source, photo-diode light receivers, and a glass tube for bilge water sample. The data processing unit has a micro-processor as hard core and peripheral devices. The experimental results of prototype OCM and analysis of collected data reveal linear property between transmitted light and scattered light as long as the bilge water has low level content of oil. And this linear property leads to a oil content detecting method which is programmed and loaded into the data processing unit. The performance of the prototype OCM is compared with that of the commercial OCM in the market.

  • PDF

유분검출기 개발을 위한 빌지 배출수의 광특성 분석 (Optical Characteristic Analysis of Bilge Water for Developing an Oil Content Meter)

  • 최상화;황정웅;정병건
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.311-320
    • /
    • 2001
  • Since 1998 for protection of marine pollution, all ships must have oil filtering equipment and 15ppm bilge alarms which satisfy Requirements of MARPOL 73/78. Oily-water separator used in machinery area of ships usually consists of two parts; one is filtering equipment and the other is oil content meter(OCM). This study presents optical characteristics of bilge were acquired form oil content sensing module. The oil content sensing module consists of IR-LED light source, photo-diode light receivers, and a glass tube for bilge water sample. The experiment with the bilge water demonstrates various valuable optical properties. These optical properties suggest notes and guides to make the low-cost, easy operation and good performance commercial type OCM that satisfy the requirements of MARPOL 73/78.

  • PDF

광섬유 진동센서를 이용한 탄소섬유강화 복합재료의 손상 및 파손검출 (Damage and Failure Detection of CFRP Using Optical Fiber Vibration Sensor)

  • 양유창;한경섭
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.254-257
    • /
    • 2001
  • An intensity-based optical fiber vibration sensor is applied to detect and evaluate damages and fiber failure of composites. The optical fiber vibration sensor is constructed by placing two cleaved fiber end, one of which is cantilevered in a hollow glass tube. The movement of the cantilevered section lags behind the rest of the sensor in response to an applied vibration and the amount of light coupled between the two fibers is thereby modulated. Vibration characteristics of the optical fiber vibration sensor are investigated. Surface mounted optical fiber vibration sensor is used in tensile and indentation test. Experimental results show that the optical fiber sensor can detect damages and fiber failure of composites correctly.

  • PDF

고토크 복합재 프로펠러 샤프트 개발에 관한 연구 (A Study on the Development of High Torque Composite Propeller Shaft)

  • 박지상;황경정;김태욱;윤형석
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.22-26
    • /
    • 2002
  • The goal of this study is to replace the current forward 2-piece propeller shaft of 8 ton large truck made of steel with 1-piece composite propeller shaft. A low cost Glass/Epoxy composite propeller shafts were successfully developed, which satisfy requirements such as the capacity of static torque transfer, fatigue strength and bending natural frequency. Devising secure joining method of a composite tube and metal yoke was the most critical issue in successful development of a high torque composite propeller shaft. In this study, joining method using thermal interference fit was adopted for composite to metal joint. Optimum conditions of heating temperature and interference level of thermal interference fit were determined from thermal stress analysis using 3D finite element method. Static torsion test, fatigue test, RPM and balance test were performed to verify the design.

  • PDF

유한요소법에 의한 평면 TV 새도우마스크의 마이크로포닉 현상 해석 (Analysis of Microphonic Phenomenon for Shadow Mask in Flat TV by FEM)

  • 김정;박수길;강범수
    • 한국정밀공학회지
    • /
    • 제19권11호
    • /
    • pp.89-95
    • /
    • 2002
  • A shadow mask inside the Braun tube of a TV is sustained by springs attached to the glass panel, its vibration cause the picture image to discolor, which is called the microphonic phenomenon. It is found that it results from resonance when the natural frequency of the shadow mask coincides with that of built-in speaker sound. This paper describes experimental and analytical investigations by using FEM on the vibration problem of the shadow mask assembly. The simulation scheme may be efficiently used to develop a new design for a large-screen flat TV.

관통성 흉부손상 176례에 대한 임상적 고찰 (Penetrating Injuries of the Chest- Analysis of 176 Cases -)

  • 허용;유회성
    • Journal of Chest Surgery
    • /
    • 제15권1호
    • /
    • pp.3-12
    • /
    • 1982
  • Although most patients with penetrating injuries can be managed successfully with early tube thoracotomy, blood volume replacement & close observation, the remainder can be saved only by an aggressive operative intervention. From January 1959, to August 1980, 176 cases with penetrating injuries had been treated at the Department of Cardiothoracic Surgery, National Medical Center. The ratio of male to female patient of penetrating chest wounds was 4.3:1 in male predominance and age from 10 to 40 occupied 76.7% of the total cases. Stab wounds was the most common penetrating injuries and followed by gunshot & glass wounds. To prevent early complications of penetrating chest injuries, thoracentesis were done in 29 cases [16%], and closed thoractomy in 40 cases [22.7%]. Open thoractomy, however, had to be done in 37 cases [21%] because of massive bleeding, hemopericardium, foreign body.

  • PDF

진단 영역의 X-선 에너지에서 각종 건축재료의 감약율 측정실험 (A Experimental Study on Attenuation Rate of Construction Materials in the Diagnostic X-ray Energy)

  • 김정민;정희원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권2호
    • /
    • pp.11-18
    • /
    • 1998
  • Single phase, narrow beam X-ray attenuation data were obtained using various construction materials concrete, white block, red block, 3 hole block, gypsum board, artificial marble, cement, plate glass, wood, and lead. Tube voltages of 60, 80, 100, 120 kVp were employed and the resulting curves were compared to transmission data found in this report. The shielding methodology and the derivation of equations used for determination of barrier requirements were presented in NCRP 49. We could calculate the X-ray exposed dose after attenuation and thickness of protection barrier in the clinic facilities accordingly. For the purpose of maximizing the benefit/cost ratio to diagnostic shielding, various construction materials must be installed carefully and attnuation rate considered thoroughly.

  • PDF

스프레이법으로 제작된 투명 MWCNT 박막 (Transparent MWCNT Thin Films Fabricated by using the Spray Method)

  • 장경욱
    • 한국전기전자재료학회논문지
    • /
    • 제23권4호
    • /
    • pp.338-342
    • /
    • 2010
  • Carbon nanotubes (CNTs) have excellent electrical, chemical stability, mechanical and thermal properties. The MWCNT films were investigated as a transparent electrode for the solar cell, OLED, and field-emission display. MWCNT films were fabricated by air spray method, whose process is quite low-costed, using the multi-walled CNTs solution on glass substrates. Moreover, the most stable film was fabricated when the spraying time was 60 sec. The film that was sprayed with the MWCNT dispersion for 60 sec, has 300nm thick. And its electric resistivity, transmittance rate, mobility and carrier concentration are $6{\times}10^{-2}{\Omega}{\cdot}cm$, 50% at ${\lambda}=550mm$, $4.3{\times}10^{-2}cm^2/V{\cdot}s$ and $2.1{\times}10^{21}cm^{-3}$, respectively. Also, absorption energy of MWCNT films show from 3.9 eV to 4.6 eV. Furthermore, we can use MWCNT films fabricated by the spray method for the transparent electrode.

Fabrication and Drive Test of a Peristaltic Thermopnumatic PDMS Micropump

  • Jeong Ok Chan;Park Sin Wook;Yang Sang Sik
    • Journal of Mechanical Science and Technology
    • /
    • 제19권2호
    • /
    • pp.649-654
    • /
    • 2005
  • This paper presents fabrication and drive test of a peristaltic PDMS micropump actuated by the thermopneumatic force. The micropump consists of the three peristaltic-type actuator chambers with microheaters on the glass substrate and a microchannel connecting the chambers and the inlet/outlet port. The micropump is fabricated by the spin-coating process, the two-step curing process, the JSR (negative PR) molding process, and etc. The diameter and the thickness of the actuator diaphragm are 2.5 mm and $30{\mu}m$, respectively. The meniscus motion in the capillary tube is observed with a video camera and the flow rate of the micro pump is calculated through the frame analysis of the recorded video data. The maximum flow rate of the micropump is about $0.36\;{\mu}L/sec$ at 2 Hz for the zero hydraulic pressure difference when the 3-phase input voltage is 20 V.