• Title/Summary/Keyword: Glass panels

Search Result 173, Processing Time 0.024 seconds

Stoichiometry dependency of the firing and sustain voltage properties of MgO thin films for AC plasma display panels (교류형 플라즈마 디스플레이용 MgO 박막의 조성변화에 따른 방전전압특성의 영향)

  • 손충용;조진희;김락환;김정열;박종완
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.1
    • /
    • pp.24-29
    • /
    • 2000
  • MgO thin films were deposited on soda lime glass substrates by rf magnetron sputtering using a MgO target at various oxygen flow ratios in order to probe the relationship between MgO film properties and discharge characteristics. MgO films have a tendency to form microstructures with a preferred growth orientation of (200) with increasing oxygen flo ration up to 0.1 $O_2$/(Ar+$O_2$). MgO film obtained at 0.1[$O_2$/(Ar+$O_2$)] was found to be fully stoichiometric. The stoichiometric MgO film was observed to have relatively very clean surface and grains of large size and contain almost no hydroxyl group. The AC PDP with fully stoichiometric MgO film showed lower firing and sustain voltages than those with magnesium-rich or oxygen-rich MgO films, being largely attributed to the larger grain size and the minimized hydroxyl group.

  • PDF

Study on application of recycled insulation-panel with fire-safety performance (화재성능이 확보된 재생 폐자원 단열재의 활용 연구)

  • Park, Kye-Won;Jeong, Jae-Gun;Kim, Hak-Yong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.167-170
    • /
    • 2010
  • This study is aiming at analyzing correlation between flashover's time and maximum smoke production rate's time on sandwich panel specimens. For this analysis, KS F ISO 137481-1 has been performed for 23 kinds of sandwich panels which mainly consist of EPS, PIR, PUR, Glass wool and so on. KS F ISO 13784-1 represents real scale reaction-to-fire test and focuses on measuring flashover phenomenon rather than other tests as like ISO 5660-1 and SBI.

  • PDF

A Study on Fire Hazards in Multiple Compartments with Lightweight Partition Walls (경량칸막이 벽체를 통한 다중구획공간에서의 화재위험성에 관한 연구)

  • Park, Sang-Min;Choi, Su-Gil;Jin, Se-Young;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.14-21
    • /
    • 2020
  • This paper presents the study of a fire risk to the backside of two miniatures of ISO 9705 2/5 using a lightweight partition for indoor space division and reproduction of the ISO 9705 test. An SGP partition, stud partition, glass wool panel, urethane foam panel, sandwich panel, and glass partition were selected as the test specimens, which are frequently used in construction. According to the ISO 9705 test standard, stabilization was achieved using a measuring device that recorded data before the ignition of a burner and continued recording for 120 s thereafter. After ignition was achieved, the power was increased to 300 kW for 600 s and then reduced to 100 kW for 600 s. The specimens were subsequently observed for 180 s, and the fire risk to the backside and the fire pattern of the wall unit were analyzed. Owing to the amount of heat generated by the ignition source, the maximum temperature of the backside was observed to be 67.7 ℃ for the SGP partition, 55.1 ℃ for the stud partition, 52.4 ℃ for the glass wool panel, 727.4 ℃ for the sandwich panel, 561 ℃ for the urethane foam panel, and 630.5 ℃ for the glass partition. In the cases of the sandwich and urethane foam panels, the explosion of flammable gas occurred by virtue of fusion of the interior materials. The reinforced glass was fractured owing to the temperature difference between the heat- and nonheat-responsive parts. Ultimately, the fire risk to the nearby section room was deemed to be high.

Properties and Structures of Bi2O3-B2O3-ZnO Glasses for Application in Plasma Display Panels Rib (PDP Rib용 Bi2O3-B2O3-ZnO계 유리의 물성과 구조)

  • Jin, Young-Hun;Jeon, Young-Wook;Lee, Byung-Chul;Ryu, Bong-Ki
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.2
    • /
    • pp.184-189
    • /
    • 2002
  • This study, compared with data of PbO-base glass system is a part of new glass composition design with Bi-base composition for PDP Rib. As $Bi_2O_3-B_2O_3-ZnO$ glass composition including Bi, which have similar density value and work facility to PbO, properties of softening point, thermal expansion coefficient, chemical durability, dielectric constant, and structural changing by XPS were investigated. $Bi_2O_3-B_2O_3-ZnO$ glass system, added 50∼80 wt% $Bi_2O_3$ widely, were presented 400∼480$^{\circ}C$ softening temperature, $68{\sim}72{\times}10^{-7}/^{\circ}C$ thermal expansion coefficient and 13∼25 dielectric constant. These results were showed similar physical properties with Pb-base glass system of same composition content, application possibility as starting composition of rib material was identified through micro-control of components and physical properties. The bonding energy of $O_{1s}$ as the $Bi_2O_3$ content decreasing was increased and full width at half-maximum (FWHM) was decreased, which is caused by non-bridging oxygen increasing.

High rate deposition of poly-si thin films using new magnetron sputtering source

  • Boo, Jin-Hyo;Park, Heon-Kyu;Nam, Kyung-Hoon;Han, Jeon-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.186-186
    • /
    • 2000
  • After LeComber et al. reported the first amorphous hydrogenated silicon (a-Si: H) TFT, many laboratories started the development of an active matrix LCDs using a-Si:H TFTs formed on glass substrate. With increasing the display area and pixel density of TFT-LCD, however, high mobility TFTs are required for pixel driver of TF-LCD in order to shorten the charging time of the pixel electrodes. The most important of these drawbacks is a-Si's electron mobiliy, which is the speed at which electrons can move through each transistor. The problem of low carier mobility for the a-Si:H TFTs can be overcome by introducing polycrystalline silicon (poly-Si) thin film instead of a-Si:H as a semiconductor layer of TFTs. Therefore, poly-Si has gained increasing interest and has been investigated by many researchers. Recnetly, fabrication of such poly-Si TFT-LCD panels with VGA pixel size and monolithic drivers has been reported, . Especially, fabricating poly-Si TFTs at a temperature mach lower than the strain point of glass is needed in order to have high mobility TFTs on large-size glass substrate, and the monolithic drivers will reduce the cost of TFT-LCDs. The conventional methods to fabricate poly-Si films are low pressure chemical vapor deposition (LPCVD0 as well as solid phase crystallization (SPC), pulsed rapid thermal annealing(PRTA), and eximer laser annealing (ELA). However, these methods have some disadvantages such as high deposition temperature over $600^{\circ}C$, small grain size (<50nm), poor crystallinity, and high grain boundary states. Therefore the low temperature and large area processes using a cheap glass substrate are impossible because of high temperature process. In this study, therefore, we have deposited poly-Si thin films on si(100) and glass substrates at growth temperature of below 40$0^{\circ}C$ using newly developed high rate magnetron sputtering method. To improve the sputtering yield and the growth rate, a high power (10~30 W/cm2) sputtering source with unbalanced magnetron and Si ion extraction grid was designed and constructed based on the results of computer simulation. The maximum deposition rate could be reached to be 0.35$\mu$m/min due to a high ion bombardment. This is 5 times higher than that of conventional sputtering method, and the sputtering yield was also increased up to 80%. The best film was obtained on Si(100) using Si ion extraction grid under 9.0$\times$10-3Torr of working pressure and 11 W/cm2 of the target power density. The electron mobility of the poly-si film grown on Si(100) at 40$0^{\circ}C$ with ion extraction grid shows 96 cm2/V sec. During sputtering, moreover, the characteristics of si source were also analyzed with in situ Langmuir probe method and optical emission spectroscopy.

  • PDF

Sound Insulation Strategy for the Tunnel Noise in a High Speed Train (고속철도차량의 터널 소음을 위한 차음 전략)

  • Kim, Seock-Hyun;Lee, Ho-Jin;Kim, Jung-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.315-322
    • /
    • 2012
  • In a tunnel, interior noise of a high speed train increases by 5dB~7dB. The reason is that the sound intensity of the acoustic field in the tunnel significantly increases by the reflected waves occurred in the closed space. Especially, the incident acoustic power largely increases on the outside of the compartment side panel and large transmission of noise is available through the side panel and the glass window. In this paper, the sound insulation strategy in the tunnel is proposed for the next generation high speed train under development. Specimens of the aluminum extruded panels, layered panels and double glazed window are manufactured and intensity transmission loss is measured according to ASTM E2249-02. Based on the measured data, problems in the sound insulation performance are diagnosed and the sound insulation strategy is reviewed on each panel and layered structures.

Prevention of Human injury and Countermeasure of evacuation about Fire of Nursing Homes by Conversion of existing buildings - Focused on rural areas in Gwangju and Jeonnam - (기존 건축물을 용도변경한 노인의료복지시설의 화재 인명피해 예방과 피난 대책 -광주·전남 농촌지역을 중심으로-)

  • Kim, Hyun-Tae;Kim, Won-Jin
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.27-36
    • /
    • 2018
  • At present, the elderly population in Korea is 14% of the total population and then We has entered an the society of advanced age. Along with this, elderly people with dementia and palsy are also increasing. The demand for elderly nursing homes for elderly people with severe diseases such as dementia and stroke is also increasing, and the existing buildings are being secured by Conversion of existing buildings. However, it is difficult to evacuate and fire due to the out of date of buildings by Conversion of existing buildings. For example, there is a fire in the Indukukwon, Pohang City and Hyosung Geriatric Hospital, Jangseong in Korea, which have changed the use of existing buildings. Many elderly people died in a night fire. It was because of the sandwich panel walls and PVC flooring material produced toxic gas instantly. In this study, we investigated the nursing home that changing the use and established fire prevention of human injury and countermeasure of evacuation. First, the sandwich panels which leading to deaths due to the toxic gas were installed in most nursing home. We recommend the RC, the masonry wall, and the glass fiber panel instead of the sandwich panels, In addition, the PVC flooring is most used in nursing home, the flooring material is considered such as the building stones, the tile, and the yellow soil closing instead of the PVC flooring. Second, we investigated the installation status of fire fighting equipment. As a result, the automatic-emergency open&shut equipment, the smoke ventilator and the evacuation slide were rarely installed. In order to secure the golden time in case of fire and to prevent the asphyxia caused by the toxic gas, the law should be amended to install the equipment.

Evaluation on Total Energy Consumption of Low-Energy House with Structural Insulated Panels (구조단열패널 적용 저에너지주택의 총에너지사용량 평가)

  • Lee, Hyeon-Ju;Nah, Hwan-Seon;Jo, Hye-Jin;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • This project is mainly related to evaluation of total energy consumption of low energy house, the exterior envelope of which was wholly composed of structural insulated panels(SIP). The U-value of applied SIP was in the range of 0.189 to $0.269W/m^2{\cdot}K$ and the U-value of pair glass from 0.78 to $1.298W/m^2{\cdot}K$ was applied for window dependent to its function respectively. For comparison of total energy performance, the energy simulation for pilot house was performed to compare with the control house having insulation criteria of Korean building regulation in 2009. Based on simulation of dynamic energy performance, the pilot house saved 48.3% of annual energy consumption while the control house in 2009 consumed as 85.7GJ/y. In case of heating, the result showed that the energy saving ratio amounted to 76.7%. For $CO_2$ emission, the pilot house diminished approximately 35.4% from $6,208.4kgCO_2$ to $4,009.2kgCO_2$. In payback period to early investment, it was analyzed the pilot house took 7.8 years, when the low energy house built by other insulation method with same thermal perfusion took 11.5 years. From this result, it is considered that the SIP is more effective, economic to Green Home application.

Development of Three D.O.F Alignment Stage for Vacuum Environment (진공용 3자유도 얼라인먼트 스테이지 개발)

  • Han, Sang-Jin;Park, Jong-Ho;Park, Hui-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.138-147
    • /
    • 2001
  • Alignment systems are frequently used under various semiconductor manufacturing environment. Particularly in PDP(Plasma Display Panel) manufacturing process, the alignment system is applied to the combining and sealing processes of the upper and lower glass panels of PDP, where these processes are performed in the vacuum chamber of high vacuum and high temperature. In this paper, the XYΘ-alignment stage is developed to align PDP panels. Because of high vacuum and high temperature environment, the alignment chamber has been designed to isolate the inner part of the alignment chamber from the outer environment of high vacuum and high temperature, in which every part of the alignment stage is inserted. As it is difficult to attach feedback sensors to the alignment stage in the alignment chamber, the alignment stage is implemented with the open loop algorithm, where the parallel link structure has been designed using step-motors and ball-screws for structural simplicity. The kinematic analysis is performed to drive the parallel link structure, based on the experiments of actuation-compensation of the alignment stage. For the error compensation, the hyperpatch model has been used to model the errors. From the experiments, the positional accuracy of the alignment stage can be improved significantly.

  • PDF

A Study on the Structural System and Implementation of Cantilever Actuator System (외팔보 엑츄에이터 시스템 구조 및 구현에 관한 연구)

  • Yoon, Keun-Young;Baek, Soo-Whang
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.4
    • /
    • pp.651-656
    • /
    • 2019
  • This paper is a study on the structure system and implementation of cantilever actuator for decontamination. There are many kinds of exterior materials that attach to the exterior walls of a building. Glass, in particular, can be contaminated in a short period of time due to external exposure. The pollutants like this damage the appearance of a building. It can also cause health problems for users, and dust attached to solar panels creates problems that greatly reduce the power generation of solar panels. In order to remove such contaminants, professional workers usually remove contaminants attached to the outer walls. However, even with stability, accidents are often caused by a number of unexpected variables that occur in the field. Thus, to overcome these shortcomings, the cantilever actuator structure system was proposed. The system was designed through research. Then, we made a cantilever actuator and checked its operability. Finally, the effectiveness of the cantilever actuator was reviewed.